Authors: Brett Bocian, Nesrin Dogan, John C. Ford, Alan Pollack, Ryder Marshall Schmidt, Junwei Shi, Jorge D Vega
Affiliation: University of Miami, University of Miami Sylvester Comprehensive Cancer Center
Abstract Preview: Purpose: X-ray fluorescence computed tomography (XFCT) is an emerging molecular imaging modality gaining attention in cancer theranostics with high-Z metal nanoparticles (MNPs). While XFCT has been de...
Authors: Fu-Xiong Chang, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Nancy Y Lee, Chih-Hsun Lin, Haibo Lin, Hang Qi, Mahbubur Rahman, Charles B. Simone, Pingfang Tsai, Shouyi Wei, Irini Yacoub, Yunjie Yang, Ajay Zheng, Jun Zhou
Affiliation: New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, Liverage Biomedical Inc., Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University, Institute of Physics, Academia Sinica
Abstract Preview: Purpose: FLASH therapy presents an opportunity to alter the radiotherapy paradigm and significantly enhancing normal organ protection while maintaining the effectiveness of tumor control. The temporal...
Authors: Sorour Hosseini, YuHuei Jessica Huang, Thomas Boyd Martin, Geoffrey S. Nelson, Nicholas Pierre Nelson, Hui Zhao
Affiliation: University of Utah, Department of Radiation Oncology, Huntsman Cancer Institute, University of Utah
Abstract Preview: Purpose: To evaluate image qualityâincluding noise, contrast-to-noise ratio (CNR), uniformity, and low-contrast visibility (LCV)âon the HyperSight and TrueBeam cone-beam computed tomography (CBCT) pla...
Authors: Ahad Ollah Ezzati, Yile Fang, Xiaoyu Hu, Xun Jia, Kai Yang, Yuncheng Zhong
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University
Abstract Preview: Purpose: With breast cancer being one of the most prevalent cancers, regular screening is an effective strategy to mitigate the risk of malignancy. However, conventional energy-integrating detector (E...
Authors: Zilei Fu, Yi Guo, Wanli Huo, Hongdong Liu, Laishui Lyu, Zhao Peng, Yaping Qi, Senting Wang
Affiliation: Department of Radiotherapy, cancer center, The First Affiliated Hospital of Fujian Medical University, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University, Division of lonizing Radiation Metrology, National Institute of Metrology, State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, China Jiliang University, Department of Oncology, Xiangya Hospital, Central South University
Abstract Preview: Purpose: Medical image boundaries are commonly characterized by smooth gray-level transitions, resulting in pixel-level segmentation errors near these blurred boundaries. To address this, we developed...
Authors: Zachary Buchwald, Chih-Wei Chang, Zach Eidex, Richard L.J. Qiu, Mojtaba Safari, Shansong Wang, Xiaofeng Yang, David Yu
Affiliation: Emory University and Winship Cancer Institute, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: MRI offers excellent soft tissue contrast for diagnosis and treatment but suffers from long acquisition times, causing patient discomfort and motion artifacts. To accelerate MRI, supervised d...
Authors: Cem Altunbas, Farhang Bayat
Affiliation: Department of Radiation Oncology, University of Colorado School of Medicine, Taussig Cancer Center, Cleveland Clinic
Abstract Preview: Purpose:
Low dose imaging and scatter rejection hardware in CBCT reduces X-ray fluence incident on the imager, increasing noise, causing photon starvation artifacts in CBCT images. In this work, we...
Authors: Alexandra Christensen, Timothy J. Hall, Ivan M. Rosado-Mendez
Affiliation: University of Wisconsin, Madison, Departments of Medical Physics and Radiology, University of Wisconsin-Madison
Abstract Preview: Purpose: Quantitative ultrasound techniques based on the statistical analysis of speckle are currently being deployed commercially and clinically as sources of biomarkers associated with tissue micros...
Authors: Shaojie Chang, Thomas A. Foley, Hao Gong, Emily Koons, Shuai Leng, Cynthia H. McCollough, Eric E. Williamson
Affiliation: Mayo Clinic
Abstract Preview: Purpose: To enhance coronary CT angiography (cCTA) capabilities on conventional energy integrating detector CT (EID-CT) using artificial intelligence (AI). The AI framework incorporates high-resolutio...
Authors: Zachary M. Diamond, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou
Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: High spatial resolution in pin ridge filter (pRF)-based proton planning may be constrained by the 1mm dose grid resolution in commercial treatment planning systems. This study investigates th...
Authors: Richard Lesieur, Olivia Magneson, David E. Solis, Sotirios Stathakis
Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center
Abstract Preview: Purpose: This study evaluates the deliverability and precision of multileaf collimator (MLC) positioning in treatment plans generated by two different Treatment Planning Systems (TPS), Monaco and Pinn...
Authors: Yuemeng Feng, Hamid Sabet
Affiliation: Massachusetts General Hospital, Harvard Medical School
Abstract Preview: Purpose: We propose a novel brain-dedicated PET system comprising elliptical cylinder with a neck cut-out, supplemented by front and back panels to improve sensitivity and line-of-response sampling. T...
Authors: Alvaro Daniel Cruz Cortes, Robin Enric Lopez Fonseca, Valeria PĂ©rez MartĂnez
Affiliation: National Autonomous University of Mexico (UNAM), Faculty of Sciences, Biomedical Physics Program, National Autonomous University of Mexico (UNAM), Faculty of Sciences, National Autonomous University of Mexico (UNAM), Faculty of Sciences, Physics Program
Abstract Preview: Purpose: Automate and evaluate daily, monthly, and annual QC of IGRT systems, following the AAPM TG-198 protocol, through the development of a graphical user interface that enables efficient analysis ...
Authors: Yifei Hao, Wenxuan Li, Xiang Li, Tao Peng, Yulu Wu, Fang-Fang Yin, Yue Yuan, Lei Zhang, Yaogong Zhang
Affiliation: Duke University, School of Future Science and Engineering, Soochow University, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose: Diffusion-based deep-learning frameworks have been recently used in MRI resolution enhancement, or super-resolution. Multi-contrast MRI share common anatomical structures while holding comple...
Authors: Victor B. Kassey, Maciej M. Kmiec, Periannan Kuppusamy, Sergey V. Petryakov, Conner Ubert
Affiliation: Dartmouth College
Abstract Preview: Purpose: Tumor hypoxiaâa state of reduced oxygen supplyâis well known to affect treatment response, particularly in radiotherapy and chemotherapy. Oxygen-enhanced magnetic resonance imaging (OE-MRI) u...
Authors: Cristel Baiu, Laura Castaneda Martinez, Ivan M. Rosado-Mendez
Affiliation: University of Wisconsin, Department of Medical Physics, University of Wisconsin-Madison, Departments of Medical Physics and Radiology, University of Wisconsin-Madison
Abstract Preview: Purpose: 2D matrix array transducers (2DMAT) are advancing volumetric ultrasound due to their ability to provide more isotropic 3D resolution, fast volumetric imaging, and highly customizable focusing...
Authors: Ted Bartley, Steven Brown, Steven Chinn, Mike Hopkins, Stanley Leong, Jerimy C. Polf, Luke Rothermel, Scott Sawyer, Benjamin L. Viglianti
Affiliation: University of California School of Medicine, University of Michigan, H3D, inc, University Hospitals, M3D, Inc, M3D Imaging, California Pacific Medical Center
Abstract Preview: Purpose: In a collaboration between surgical oncologists and medical physicists, a new intra-operative gamma camera for imagining sentinel lymph nodes (SLN) during radio-guided SLN biopsy procedures h...
Authors: Petr Bruza, Eric R. Fossum, Alexander Geiersbach, David J. Gladstone, Karthik Raj Venkatesan
Affiliation: Dartmouth College, Thayer School of Engineering, Dartmouth College
Abstract Preview: Purpose: Current Cherenkov imaging sensors rely on image intensifiers to generate sufficient signal for photon detection. While image intensifiers (IIs) exhibit good Cherenkov photon signal response, ...
Authors: Kimberly Chan, Anke Henning, Mahrshi Jani, Andrew Wright, Xinyu Zhang
Affiliation: Advanced Imaging Research Center (AIRC), UT Southwestern Medical Center
Abstract Preview: Purpose: To evaluate the performance of multiple deep learning architectures for MRSI reconstruction and determine their effectiveness in maintaining high-resolution metabolite mapping while reducing ...
Authors: Srinivas Cheenu Kappadath, Brian Michael Kelley, Benjamin P. Lopez
Affiliation: UT MD Anderson Cancer Center
Abstract Preview: Purpose:
Imaging systems are subject to errors from finite spatial resolution and voxel size. This work demonstrates their effect on dose algorithm {Monte Carlo (MC), dose-volume kernel (DVK), and ...
Authors: Matthew R. Hoerner, Maryam Naseri, Mena Shenouda
Affiliation: Yale University School of Medicine, Yale University
Abstract Preview: Purpose: To evaluate acquisition parameters of computed tomography (CT) scanner protocols across different machines to provide patients and clinicians consistent care and image quality, respectively.<...
Authors: Nathalie Correa, Janet Ching-Mei Feng, Chun-Han Huang, Jimmy Huynh
Affiliation: UTHealth McGovern Medical School
Abstract Preview: Purpose: To compare the image quality and the dose-area product (DAP) of four mobile digital radiography (DR) systemsâCanon (Soltus 500), Shimadzu (MobileDaRt Evolution MX8), Solution for Tomorrow (M1...
Authors: Krystal M. Kirby, Aliasghar Rohani, Christopher W. Schneider, Sotirios Stathakis
Affiliation: Mary Bird Perkins Cancer Center, Louisiana State University, Baton Rouge, Louisiana
Abstract Preview: Purpose: Accurate treatment delivery in MR-guided radiotherapy (MRgRT) systems requires consistent imaging quality assurance (QA) to assess MR image quality. However, standard QA phantoms have limited...
Authors: Laura I. Cervino, Karen Episcopia, Hsiang-Chi Kuo, Sangkyu Lee, Seng Boh Gary Lim, Shih-Chi Lin, Grace Tang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: This study evaluated the performance of the HyperSight Cone-Beam Computed Tomography (CBCT) system on a TrueBeam C-arm LINAC (TB) and two Ethos ring-gantry LINACs (ES) for adaptive radiation ...
Authors: Emi Ai Eastman, Christina Lee, Xinhua Li, Alexander W. Scott, Yifang (Jimmy) Zhou
Affiliation: Cedars-Sinai Medical Center
Abstract Preview: Purpose: Iterative reconstruction (IR) methods are valuable for reducing dose in modern CT; however, IR methods have the effect of reducing spatial resolution and hence the lesion edge sharpness. Furt...
Authors: Imad M. Ali, Nesreen Alsbou, Baraa Kalani
Affiliation: Oklahoma State University, University of Central Oklahoma, University of Oklahoma Health Sciences Center
Abstract Preview: Purpose: To develop a three-dimensional Winston-Lutz phantom to quantify the isocentricity of the gantry, couch, and on-board imager of the MEVION-S250i proton therapy machine.
Methods: A 3D-scinti...
Authors: Imad M. Ali, Nesreen Alsbou, Sakeeneh Majeed
Affiliation: University of Central Oklahoma, University of Oklahoma Health Sciences Center
Abstract Preview: Purpose: to design and assess a microwave imaging system equipped with multiple antennas for generating high-resolution 3D images of phantom models that simulate abdominal, thoracic, and brain tissues...
Authors: Go Akamatsu, Yuma Iwao, Kurumi Narita, Hideaki Tashima, Taiga Yamaya, Eiji Yoshida
Affiliation: National Institutes for Quantum Science and Technology
Abstract Preview: Purpose: In brain positron emission tomography (PET), higher spatial resolution is better for visualizing detailed structures such as small nuclei and the layered structure of the cerebral cortex. The...
Authors: Dukagjin Blakaj, Zhilin Hu, Stephen Kang, Abberly Lott Limbach, Lanchun Lu, Henry Xiang, Jie Zhang
Affiliation: Pharostek, Department of Pediatrics, The Ohio State University, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Department of Radiology, University of Kentucky, Department of Pathology, The Ohio State University, Department of Radiation Oncology, The Ohio State University, Department of Otolaryngology, The Ohio State University
Abstract Preview: Purpose: Detect surgical margin in vivo using an original barcode-reading type portable OCT imaging system.
Methods: We developed a barcode-reading type portable optical coherence tomography (OCT) ...
Authors: Adedamola Adeniyi, Bryan Bednarz, Malick Bio Idrissou, Reinier Hernandez, Ohyun Kwon, Brian W. Miller, Zachary S Morris, Maya Takashima, Jamey Weichert
Affiliation: Departments of Radiation Oncology and Medical Imaging, University of Arizona, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Medical Physics, School of Medicine and Public Health, University of WisconsinâMadison, Department of Radiology, School of Medicine and Public Health, University of WisconsinâMadison, Department of Human Oncology, School of Medicine and Public Health, University of WisconsinâMadison
Abstract Preview: Purpose: As radiopharmaceutical therapy (RPT) becomes more prevalent in clinical applications, understanding dose-response relationships in the tumor microenvironment (TME) and normal tissues is essen...
Authors: Hyo-Min Cho, Changwoo Lee
Affiliation: Korea Research Institute of Standards and Science
Abstract Preview: Purpose: We develop sphere phantoms to assess spatial resolution of computed tomography (CT) systems and validate its usability using table-top X-ray experiment systems.
Methods: We manufactured sp...
Authors: Soo Hyun Byun, Troy Farncombe, Edcer Jerecho DC Laguda
Affiliation: McMaster University
Abstract Preview: Purpose: We present the adaptation of a Cadmium Zinc Telluride (CdZnTe) detector, initially designed for SPECT-MR applications, to neutron imaging. This study explores a novel technique that utilizes ...
Authors: John M. Boone, Andrew M. Hernandez, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski
Affiliation: Johns Hopkins University, University of California, UT MD Anderson Cancer Center, University of New Mexico Albuquerque, UC Davis Health
Abstract Preview: Purpose: To significantly improve image quality relative to clinically deployed digital breast tomosynthesis (DBT) systems, which use a 1D acquisition geometry (an arc), with a 2D image acquisition ge...
Authors: Beth Reed, Justin B. Solomon
Affiliation: Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System
Abstract Preview: Purpose: The purpose of this study was to compare image quality between CT images of variable slice thickness reconstructed directly at the scanner verses reformatted at a PACS workstation.
Methods...
Authors: Leshan Sun, Liangzhong Xiang, Yifei Xu, Yuchen Yan
Affiliation: University of California, Irvine
Abstract Preview: Purpose: X-ray Acoustic Computed Tomography (XACT) is a transformative innovation in medical imaging, overcoming the limitations of conventional X-ray techniques. It introduces new possibilities in cl...
Authors: Rashmi Bhaskara, Oluwaseyi Oderinde
Affiliation: Purdue University
Abstract Preview: Purpose: This study proposes a novel approach to overcoming CBCT image quality limitations by developing an improved synthetic CT (sCT) generation method based on a CycleGAN architecture using Vision ...
Authors: Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Nishan Shrestha, Somol Sunny
Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida
Abstract Preview: Purpose: Accurate delineation of the urethra is critical for optimizing tumor control and minimizing urethral toxicity in prostate stereotactic body radiation therapy (SBRT). The purpose of this study...
Authors: Nema Bassiri, Kristen A. Duke, Neil A. Kirby, Thomas Wilson Klender, Christien Kluwe, Niko Papanikolaou, Holly Paschal, Karl H. Rasmussen, Daniel L. Saenz, Michelle de Oliveira
Affiliation: Miami Cancer Institute, University of Texas HSC San Antonio, UT Health San Antonio
Abstract Preview: Purpose: Determine the practical usability for three phantoms to be used with the ExacTrac Dynamic thermal imaging system. Thermal-guided imaging can be used for inter and intra motion management, pat...
Authors: Li Tong, Chuyan Wang, Zhengkui Wang, Yingli Yang, Jie Zhang
Affiliation: Shanghai United imaging Healthcare Advanced Technology Research Institute, Shanghai United Imaging Healthcare Co., LTD, Department of Radiology, Ruijin Hospital, Institute for Medical Imaging Technology, Ruijin Hospital
Abstract Preview: Purpose:
Pelvic radiotherapy (RT)-induced bone marrow (BM) damage affects patient prognosis by causing hematologic toxicity. However, consensus on BM-sparing (BMS) RT is still lacking, owing to the...
Authors: Chunhui Han, An Liu, William T. Watkins, Qiuyun Xu
Affiliation: Department of Radiation Oncology, City of Hope National Medical Center
Abstract Preview: Purpose: To evaluate the RefleXion X1 imaging system as a standalone positron emission tomography and computed tomography (PET/CT) simulator for radiotherapy treatment planning and adaptive re-plannin...
Authors: Tae Kyu Lee
Affiliation: Allina Health
Abstract Preview: Purpose: To assess the feasibility of a dynamic-platform integrated with high-resolution patient-specific-quality-assurance (PSQ device for periodic quality assurance (PQA) and PSQA in respiratory-gat...
Authors: Claire Keun Sun Park, Atchar Sudhyadhom, Veena Venkatachalam, Noah Warner
Affiliation: HarvardâMIT Program in Health Sciences and Technology, Massachusetts Institute of Technology, Brigham and Womenâs Hospital and Dana Farber Cancer Institute, Harvard Medical School,, Brigham and Womenâs Hospital and Dana Farber Cancer Institute, Harvard Medical School
Abstract Preview: Purpose: Modern radiotherapy achieves sub-millimeter spatial accuracy but fails to account for patient- and spatially-specific variations in biological response. Free radical generation (FRG), particu...
Authors: Zachary Buchwald, Chih-Wei Chang, Zach Eidex, Hui Mao, Richard L.J. Qiu, Justin R. Roper, Mojtaba Safari, Hui-Kuo Shu, Xiaofeng Yang, David Yu
Affiliation: Emory University and Winship Cancer Institute, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University, Emory University School of Medicine
Abstract Preview: Purpose: MRI-guided radiation therapy (MRgRT) benefits significantly from enhanced soft-tissue contrast and spatial resolution, which aid in accurately delineating tumors and organs at risk. Although ...
Authors: Oluyemi Bright Aboyewa, KyungPyo Hong, Daniel Kim
Affiliation: Department of Radiology, Northwestern University
Abstract Preview: Purpose: While non-Cartesian MRI is desirable for fast imaging with high spatial resolution and robustness to motion, it requires long post-processing times. Preconditioning with an adequate density c...
Authors: Matthew R. Hoerner, Maryam Naseri, Mena Shenouda
Affiliation: Yale University School of Medicine, Yale University
Abstract Preview: Purpose:
Historically film has been the gold standard receptor for measurements of x-ray tube focal spot size. Flat Panel Digital Radiography Detectors (FPDRDs) have lower spatial resolution compar...
Authors: Xun Jia, Heng Li, Wen Li, Devin Miles, Daniel Sforza, Lingshu Yin, Yuncheng Zhong
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University
Abstract Preview: Purpose: FLASH therapy holds great potential to revolutionize radiotherapy by minimizing toxicities of normal tissues. The extraordinarily high dose rate of FLASH proton beam makes precise delivery to...
Authors: Samuel L. Brady, Kevin Chen, Joseph G. Meier
Affiliation: University of Cincinnati, Cincinnati Childrens Hospital Med Ctr
Abstract Preview: Purpose: Conebeam-CT (CBCT) acquisition protocols typically do not distinguish between adults and pediatrics. In collaboration with a fluoroscopically-guided interventional (FGI) manufacturer, new, do...
Authors: Wendy Siman, Wei Zhou
Affiliation: University of Colorado Anschutz Medical Campus, School of Medicine
Abstract Preview: Purpose:
To compare the image quality and radiation dose of 3D cone-beam CT modes of a mobile C-arm and an O-arm unit for intraoperative imaging.
Methods:
A 50-”m tungsten wire was imaged at ...
Authors: Mohammadreza Ay, Nahal Daneshgar, Nima Kasraie, Abbas Monsef, Zeinab Peymani, Hadi Rezaei, Peyman Sheikhzadeh
Affiliation: University of Minnesota Medical School, Radiation Oncology, Department of Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences, Shiraz University of Medical Sciences, Department of Medical Physics, Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, UT Southwestern Medical Center, Imam Khomeini Hospital Complex,Tehran University of Medical Sciences
Abstract Preview: Purpose:
This study aims to design and simulate an innovative pediatric-dedicated SPECT scanner optimized for childrenâs unique anatomical and safety needs by enhancing sensitivity in data acquisit...
Authors: Salim Balik, Nguyen Phuong Dang, Hualin Zhang
Affiliation: Radiation Oncology, Keck School of Medicine of USC
Abstract Preview: Purpose: An accurate and convenient monitoring of radiation dose delivery during treatment is essential for ensuring patient safety and treatment efficacy. This project aims to develop innovative algo...
Authors: Saree Alnaghy, Owen Thomas Dillon, Sean P Hood, Paul J. Keall, Ricky O'Brien, Tess Reynolds
Affiliation: Image X Institute, Faculty of Medicine and Health, The University of Sydney, University of Wollongong, Medical Radiations, School of Health and Biomedical Sciences, RMIT University
Abstract Preview: Purpose: Photon Counting Detectors (PCDs) have been demonstrated to improve resolution, contrast and lesion detectability in fan-beam CT. There is naturally a desire to bring these improvements to Con...
Authors: Molokotima Kekana, Dennis S. Mackin, Stephen W. Peterson, Jerimy C. Polf
Affiliation: Department of Physics, University of Cape Town, M3D, Inc, The University of Texas MD Anderson Cancer Center, Houston
Abstract Preview: Purpose: To study the imaging characteristics of a prototype prompt gamma (PG) imaging system consisting of multiple rotating Compton cameras (CC).
Methods: The prototype CC imaging system is c...
Authors: Matthew R. Hoerner, Allison Shields
Affiliation: Yale University School of Medicine, Yale University
Abstract Preview: Purpose: To investigate the quality and clinical utility of chest x-rays synthesized from CT scans (sCXR).
Methods: Five helical chest CT exams were chosen for evaluation: this cohort represented a...
Authors: Christopher P. Favazza, Andrea Ferrero, Taylor Froelich, Forrest Linch, Scott Thompson
Affiliation: Mayo Clinic
Abstract Preview: Purpose: Photon counting detector (PCD) CT is a promising tool to enhance pre-procedural planning and intra-procedural guidance for prostate artery embolization due to its unsurpassed ultra-high spati...
Authors: Awens Alphonse, Nebi Demez, Brian P. Laffey, Shyam Pokharel, Suresh Rana, Nishan Shrestha
Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida
Abstract Preview: Purpose: The Imaging Ring is a mobile digital X-ray system capable of producing 2D planar X-rays, fluoroscopy, and 3D Cone-Beam Computed Tomography (CBCT) images. This study aimed to evaluate the long...
Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal
Affiliation: Radboud University Medical Center, University of SĂŁo Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de FĂsica Gleb Wataghin
Abstract Preview: Purpose: The study evaluated the accuracy and precision of lung nodule volume measurements, specifically solid nodules (SNs) and ground-glass opacities (GGOs) in different imaging settings.
Methods...
Authors: Ziqi Gao, Lei Xing, Siqi Ye, S. Kevin Zhou
Affiliation: Department of Radiation Oncology, Stanford University, University of Science and Technology of China (USTC)
Abstract Preview: Purpose: To address the challenge of high memory usage in volumetric cone-beam CT (CBCT) imaging, we propose a method that combines joint reconstruction and super-resolution for sparsely sampled CBCT ...
Authors: Karyn A Goodman, Yang Lei, Tian Liu, D. Michael Lovelock, Charlotte Elizabeth Read, Jing Wang, Jiahan Zhang
Affiliation: Icahn School of Medicine at Mount Sinai
Abstract Preview: Purpose: Real-time volumetric MRI is essential for precise motion management in MRI-guided radiotherapy (MRIgRT). While 2D Cine MRI offers high temporal resolution for motion tracking, it inherently l...
Authors: Peymon Ghazi
Affiliation: MALCOVA Inc.
Abstract Preview: Purpose: To develop a near scatterâfree breast CT imaging system that expands coverage of the posterior breast anatomy and enhances contrast resolution for solid masses and microcalcifications, while ...
Authors: Jia Wang, Vani Yadav
Affiliation: Stanford University
Abstract Preview: Purpose: To evaluate the radiation dose and imaging quality of two novel CBCT X-Ray imaging systems used in spine surgeries.
Methods: CBCT scan of ACR CT and CTDI phantoms was performed to acquire ...
Authors: Karyn A Goodman, Yang Lei, Tian Liu, Charlotte Elizabeth Read, Jing Wang, Qian Wang, Jiahan Zhang
Affiliation: Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology, Beth Israel Deaconess Medical Center
Abstract Preview: Purpose: Accurate motion management in MRI-guided radiotherapy (MRIgRT) relies on real-time volumetric MRI to track intra-fractional anatomical changes. Dense k-space sampling, while capable of produc...
Authors: Stephen Araujo, Jing-Tzyh Alan Chiang, Cynthia E. Davis, Eri Haneda, Andrew Karellas, Thomas C Larsen, William Ross, Hsin Wu Tseng, Srinivasan Vedantham, Pengwei Wu
Affiliation: Department of Biomedical Engineering, The University of Arizona, GE Aerospace Research, Department of Medical Imaging, The University of Arizona, GE HealthCare Technology & Innovation Center
Abstract Preview: Purpose: The purpose of this work is to describe the design and development of a newly developed upright-geometry dedicated breast CT system and to quantitatively and qualitatively evaluate its imagin...
Authors: Carina Gassner, Guyue Hu, Thomas Kröncke, Christopher Kurz, Guillaume Landry, Katharina Niepel, Katia Parodi, Franka Risch, Florian Schwarz
Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t (LMU) MĂŒnchen, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t MĂŒnchen (LMU Munich)
Abstract Preview: Purpose: To evaluate the performance of a clinical photon-counting CT (PCCT) scanner in terms of proton relative stopping power (RSP) estimation using PCCT data and to compare the impact of different ...
Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din
Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University
Abstract Preview: Purpose: This study introduces a novel approach for patient-specific quality assurance in proton beam therapy, utilizing new plastic scintillator detectors with high temporal resolutions to create det...
Authors: Muhammad Ramish Ashraf, Clinton Gibson, Gregory Szalkowski, Lei Wang, Siqi Wang, Lei Xing
Affiliation: Department of Radiation Oncology, Stanford University, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University
Abstract Preview: Purpose: To develop a neural network-based super-resolution framework for enhancing the resolution of sparse dosimetry measurements in patient-specific radiotherapy QA. Sparse detector arrays, such as...
Authors: Salahuddin Ahmad, Imad M. Ali, Zaid Alkalani, Nesreen Alsbou
Affiliation: University of Oklahoma, University of Central Oklahoma, University of Oklahoma Health Sciences Center
Abstract Preview: Purpose: To design and evaluate a 3D-detector for proton CT-imaging and radiography, utilizing volumetric plastic scintillator detector exposed to high-energy therapeutic beams from proton therapy sys...
Authors: Petr Bruza, Alexander Geiersbach, David J. Gladstone
Affiliation: Thayer School of Engineering, Dartmouth College
Abstract Preview: Purpose: Cherenkov images are two-dimensional projections of the surface light emissions, and lack spatial information about the radiotherapy beam delivery. We implement the first fusion of Cherenkov ...
Authors: Casey C. Heirman, Kyle J. Lafata, Xiang Li, Breylon Riley, Jack B Stevens, Tammara Watts
Affiliation: Duke University, Department of Radiation Oncology, Duke University
Abstract Preview: Purpose: To leverage quantitative fluorescence imaging and spatial transcriptomics for characterizing the spatial and molecular heterogeneity of the tumor microenvironment (TME) in HPV+ head and neck ...
Authors: Anahita Bakhtiari Moghaddam, Don F. DeJongh, Ethan DeJongh, Jennifer Hardt, Oliver JĂ€kel, Lukas Martin, Alexander Pryanichnikov, Joao Seco, Christina Stengl, Niklas Wahl
Affiliation: Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Division of Biomedical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), ProtonVDA LLC, Department of Physics and Astronomy, Heidelberg University, Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT)
Abstract Preview: Purpose:
To evaluate the feasibility and performance of single-plane position tracking for proton and helium pencil beam radiography using a prototype imaging system, with the goal of providing a c...
Authors: Hadley Anna DeBrosse, Kevin J. Little
Affiliation: The Ohio State University
Abstract Preview: Purpose: This work examines the consistency and pattern of spatial resolution degradation in weekly quality control (QC) testing prior to CT tube failure and replacement and investigates potential cor...
Authors: Kim Creach, Kim Howard, Julius G. Ojwang, Richard A. Shaw, Neelu Soni
Affiliation: Mercy Hospital Springfield
Abstract Preview: Purpose: To present a standardized MRI-CT hybrid workflow for High-Dose-Rate (HDR) Image-Guided Adaptive Brachytherapy (IGBT) in cervical cancer, aligned with AAPM TG-303, as a model to assist with im...
Authors: Jennifer Kwak, Chelsea Manica, Justin K. Mikell, Michael Silosky, Wendy Siman
Affiliation: Washington University School of Medicine in St. Louis, University of Colorado Anschutz Medical Campus, School of Medicine, Rocky Vista University
Abstract Preview: Purpose:
This study evaluates synthetic planar imaging (synP) from SPECT projections against conventional planar imaging, focusing on detectability, spatial resolution, and feasibility. SynP allows...
Authors: Azza Mohamed Ahmed, Nadine Francis, Osama Khan, Nabil Maalej, Aamir Raja, Briya Tariq
Affiliation: Khalifa University
Abstract Preview: Purpose: The study aims to evaluate the task-specific diagnostic performance of spectral photon-counting CT (SPCCT) using application-specific phantoms.
Methods:
Parameters such as linearity res...
Authors: Aditya P. Apte, Joseph O. Deasy, Yusuf Emre Erdi, Anqi Fu, Johannes Hertrich, Andrew Jackson, Usman Mahmood, Jason Ocana, Trahan Sean, Amita Shukla-Dave
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Automated AI-based quantitative CT tools hold immense promise for advancing clinical decision-making, yet their reproducibility and generalizability remain vulnerable to variability in imagin...
Authors: Jing Qian, Brandon Reber, David M. Routman, Satomi Shiraishi
Affiliation: Mayo Clinic
Abstract Preview: Purpose: The dose distribution in proton radiotherapy (PRT) is characterized by sharp gradients, posing a challenge for machine learning-based dose prediction. While denoising with diffusion processes...
Authors: Jie Deng, Yunxiang Li, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Magnetic Resonance Imaging (MRI) has exceptional soft tissue contrast and an essential role in radiotherapy. The introduction of clinical MR-LINACs has enabled adaptive radiotherapy (ART) usi...
Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed
Affiliation: Bay Pines VA Medical Center
Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...