Evaluating 177Lu-PSMA-I&t Reconstruction Parameter Influences on Image Quality and Quantification

Authors: Martin Auerbach, Jeremie Calais, Johannes Czernin, Magnus Dahlbom, Zachary Ells, Adrien Holzgreve, Koichiro Kimura, Karam Masri, Catherine (Caffi) Meyer, David Sennung

Affiliation: Department of Nuclear Medicine, UCLA, UCLA, University of California, Los Angeles

Abstract Preview: Purpose: Lutetium-177 PSMA SPECT/CT imaging offers the possibility of qualitative image analysis for tumor response assessment and quantitative image analysis for individualized dosimetry. However, th...

Improving Quantitative Accuracy of Maximum-a-Posteriori Expectation Maximization Reconstruction By Optimizing Gibbs Prior Parameters in SPECT

Authors: Krishnendu Saha

Affiliation: Cleveland Clinic Foundation

Abstract Preview: Purpose: The goal is to improve quantitative accuracy of a Maximum-a-posteriori expectation maximization (MAPEM) reconstruction of SPECT phantom images by optimizing Gibbs prior parameters.
Methods...

Lu-177 Recovery Coefficients Using Tc-99m Surrogate Method: Intra- & Inter-Scanner Comparison

Authors: Ben Piacitelli, Celeste Winters

Affiliation: OHSU, Department of Diagnostic Radiology, Oregon Health & Science University

Abstract Preview: Purpose: To compare recovery coefficients measured with Lu-177 and Tc-99m with the goal of assessing accuracy of the Tc-99m surrogate method and comparing RC reproducibility between scanners of the sa...

Moving Towards Independent Assays of 90y Glass Microsphere Activity: Monte Carlo Simulation with Experimental Data

Authors: Mercy Iyabode Akerele, Yuni K. Dewaraja, Richard Laforest, Justin K. Mikell, Wendy Siman, Allan Thomas, Daniel Thorek

Affiliation: University of Michigan, Washington University School of Medicine in St. Louis, Washington University School of Medicine, University of Colorado Anschutz Medical Campus, School of Medicine, Washington University in St. Louis, Mallinckrodt Institute of Radiology, Washington University School of Medicine

Abstract Preview: Purpose: Post-therapy quantitative 90Y SPECT and PET measurements show ~25% lower activity than vendor-reported values for glass microspheres. We hypothesize this discrepancy is due to bremsstrahlung ...

Multi-Path Deep Learning Model for Predicting Post-Radiotherapy Functional Liver Imaging in Patients with Hepatocellular Carcinoma

Authors: Smith Apisarnthanarax, Stephen R. Bowen, Sunan Cui, Jie Fu, Clemens Grassberger, Yulun He, Yejin Kim, Matthew J. Nyflot, Sharon Pai

Affiliation: Department of Radiation Oncology, University of Washington and Fred Hutchinson Cancer Center, Department of Radiation Oncology, University of Washington, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Department of Physics, University of Washington, University of Washington and Fred Hutchinson Cancer Center

Abstract Preview: Purpose: 99mTc-sulfur colloid SPECT imaging enables quantitative assessment of voxel-wise liver function in patients with hepatocellular carcinoma (HCC). Accurately predicting post-radiotherapy (RT) l...

Multi-Vendor Validation of a Deep Learning-Based Synthetic CT Generation Model for MR-Only Radiotherapy Planning in the Pelvis

Authors: Gregory Bolard, Rabten Datsang, Sarah Ghandour, Timo Kiljunen, Pauliina Paavilainen, Sami Suilamo, Katlin Tiigi

Affiliation: Turku University Hospital, Virginia Commonwealth University, MVision AI, North Estonia Medical Centre, Docrates Cancer Center, Hopital Riviera-Chablais

Abstract Preview: Purpose: To verify the performance of a vendor-neutral deep learning model for synthetic CT generation from T2-weighted and balanced steady-state MR sequences to support both MR-only simulation and MR...

Optimizing Dosimetry in Rpt Clinics: Tackling Initial Hurdles and Ensuring Image Accuracy.

Authors: Siju C. George, Alonso N. Gutierrez, Vivek Mishra, Ranjini P. Tolakanahalli

Affiliation: Miami Cancer Institute, Baptist Health South Florida, Miami Cancer Institute

Abstract Preview: Purpose: This presentation focuses on optimizing dosimetry in RPT clinics by tackling initial setup challenges and ensuring the accuracy of SPECT/CT imaging for dosimetry. It will address the qualific...

Personalized Dosimetric Workflow for 177Lu-PSMA Treatments Considering the Cross-Irradiation from Bone Metastases to Red Bone Marrow

Authors: Nadège Anizan, David Broggio, Désirée Deandreis, Didier Franck, Camilo Garcia, Stéphanie Lamart, Sébastien Leygnac, Alexandre Pignard

Affiliation: Gustave Roussy, Service de Physique Médicale, Institut Bergonié, Service de Physique Médicale, Gustave Roussy, Service de Médecine Nucléaire, Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSE-SANTE/SDOS/LEDI, Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSE-SANTE/SDOS

Abstract Preview: Purpose: This work aimed at developing an innovative workflow for 177Lu-PSMA personalized dosimetry to lesions and organs at risk (OAR) simultaneously, considering the cross-irradiation from bone meta...

Photon Counting CT Method for Accurate Effective Atomic Number and Electron Density Measurement

Authors: Mohammed Alzaabi, Abderaouf Behouch, Nabil Maalej, Aamir Raja, Briya Tariq

Affiliation: Khalifa University

Abstract Preview: Purpose: Spectral Photon Counting CT (SPCCT) has emerged as a transformative technology in CT imaging capable of producing images from distinct energy windows, allowing improved material characterizat...

Quantitative SPECT Imaging of Alpha Emitters, Including Acquisition and Reconstruction Considerations

Authors: Yong Du

Affiliation: Department of Radiology, Johns Hopkins University

Abstract Preview: N/A...

Quantitative SPECT: Commercial Vendor Solutions.

Authors: Jazmin Schwartz

Affiliation: Memorial Sloan Kettering Cancer Center

Abstract Preview: N/A...

Quantitative SPECT: Comparison across Platforms.

Authors: Rachel Barbee

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: N/A...

Using Multi-Peak Reconstructions for Dosimetry of Fast and Quantitative Lutetium-177 SPECT/CT

Authors: Julia Brosch-Lenz, Munir Ghesani, Francesc Massanes, Michael Morris, Babak Saboury, Eliot Siegel, Alexander Hans Vija

Affiliation: Institute of Nuclear Medicine, Siemens Medical Solutions USA Inc., Molecular Imaging

Abstract Preview: Purpose: Quantitative imaging of the radiopharmaceutical distribution is crucial for treatment evaluation and dosimetry. However, as patient numbers for Lutetium-177-(177Lu)-labelled therapies continu...

What Goes into Making SPECT Data Quantitative?

Authors: Stephen A. Graves

Affiliation: University Of Iowa

Abstract Preview: N/A...