Search Submissions 🔎

Results for "spot map": 27 found

A Dosimetric Investigation into the Potential of Aperture-Based Techniques to Improve the Clinical Outcomes of Single-Energy Proton Bragg Peak Flash Therapy for Ocular Cancers

Authors: Arpit M. Chhabra, J Isabelle Choi, Minglei Kang, Haibo Lin, Hang Qi, Charles B. Simone, Shouyi Wei, Irini Yacoub, Francis Yu, Xingyi Zhao, Ajay Zheng

Affiliation: New York Proton Center, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose:
Pencil beam scanning (PBS) proton therapy effectively treats ocular cancer by minimizing exit doses to normal tissues. However, challenges remain in sparing nearby organs-at-risk(OARs). Ul...

A Dosimetric Study of Small-Field Apertured Spot-Scanning Proton Stereotactic Radiosurgery for Pediatric Brain Tumors

Authors: Chin-Cheng Chen, Chia-Ho Hua, Christopher J. Kutyreff, Thomas E. Merchant

Affiliation: St. Jude Children's Research Hospital

Abstract Preview: Purpose: A dosimetric study was conducted to determine the optimal field parameters for a commercially available small-field applicator (SFA) used in spot-scanning proton stereotactic radiosurgery, pa...

Adaptive Proton Flash Therapy through Iterative Modular Pin Recycling

Authors: Zachary Diamond, Pretesh Patel, Sibo Tian, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose:
We propose a method to optimize adaptive proton FLASH therapy (ADP-FLASH) using modularized pin-ridge filters (pRFs) by recycling module pins from the initial plan, reducing pRF adjustment...

An International Multi-Institutional Espresso Study of Developing the Specialized-Equipment-Free Remote Audit for Single-Isocenter Multi-Target Stereotactic Radiosurgery

Authors: Juan-Francisco Calvo-Ortega, Andrew Cousins, Ashley Cullen, Andrew Dipulia, Peter B. Greer, Seng Boh Gary Lim, Shih-Chi Lin, D. Michael Lovelock, Conor McGarry, Victoria Robinson, Cameron Stanton, Baozhou Sun, Ching-Ling Teng, Gemma Warner, Benjamin J. Zwan

Affiliation: Northern Ireland Cancer Centre, Baylor College of Medicine, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Christchurch Hospital, Northwell, Central Coast Cancer Centre, Calvary Mater Hospital, Hospital Quironsalud Barcelona, Icahn School of Medicine at Mount Sinai, Chris O'Brien Lifehouse, University of Newcastle

Abstract Preview: Purpose: This multi-institution Electronic Silicon-based Remote Survey of Small-field Output (ESPRESSO) study aims to develop the remote audit process to evaluate the safety of single-isocenter multi-...

Automated Quantitative Method for Source Position Calculation in Annual Quality Assurance of High Dose Rate Brachytherapy Gynecological Applicators

Authors: Ivan M. Buzurovic, Matthew W. Jacobson, Marjan Khosravi

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, University of Massachusetts Lowell, Department of Physics, Lowell, MA/Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology

Abstract Preview: Purpose: Annual quality assurance (QA) of high dose rate (HDR) brachytherapy (BT) gynecological (GYN) applicators is critical to ensure accurate and consistent source position and dose delivery. In th...

Box-Prompt Zero-Shot Smart Segmentation in Radiation Oncology Using a SAM-Based Model: Smartsam

Authors: Kristen A. Duke, Samer Jabor, Neil A. Kirby, Parker New, Niko Papanikolaou, Arkajyoti Roy, Yuqing Xia

Affiliation: St. Mary's University, The University of Texas San Antonio, UT Health San Antonio

Abstract Preview: Purpose:
The Segment Anything Model (SAM) is a foundational box-prompt-based model for natural image segmentation. However, its applicability to zero-shot 3D medical image segmentation, particularl...

CNN-Based Reconstruction for 3D Scintillation Dosimetry of Proton Pencil Beams

Authors: Sam Beddar, Jason Michael Holmes, Daniel G. Robertson, James J. Sohn, Ethan D. Stolen

Affiliation: Department of Radiation Oncology, Mayo Clinic, MD Anderson Cancer Center, Department of Radiation & Cellular Oncology, University of Chicago, Department of Radiation and Cellular Oncology, University of Chicago

Abstract Preview: Purpose: Camera-based scintillation dosimetry incorporating large volumes have shown promise for fast and comprehensive evaluation of external beam treatment fields. While some efforts have been made ...

Clinically Ready Simulation Package for Monitoring Gamma Hotspot Emission, and Detection in Patient Anatomy

Authors: Ananta Raj Chalise, Matthias K Gobbert, Zhuoran Jiang, Sina Mossahebi, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma, Jie Zhang

Affiliation: University of Maryland School of Medicine, University of Maryland Baltimore County, University of Maryland, Baltimore County, Stanford University, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc

Abstract Preview: Purpose: Prompt gamma (PG) imaging is a promising modality for proton dose verification. Currently, there is a lack of effective tool to investigate the PG emission during proton therapy and optimize ...

Comparison of Image Quality and Radiation Dose Among Four Vendors of Mobile Digital Radiography Systems

Authors: Nathalie Correa, Janet Ching-Mei Feng, Chun-Han Huang, Jimmy Huynh

Affiliation: UTHealth McGovern Medical School

Abstract Preview: Purpose: To compare the image quality and the dose-area product (DAP) of four mobile digital radiography (DR) systems—Canon (Soltus 500), Shimadzu (MobileDaRt Evolution MX8), Solution for Tomorrow (M1...

Development of a High-Speed Digital Breast Tomosynthesis System with a Two-Dimensional Multiple X-Ray-Source Array

Authors: John M. Boone, Andrew M. Hernandez, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski

Affiliation: Johns Hopkins University, University of California, UT MD Anderson Cancer Center, University of New Mexico Albuquerque, UC Davis Health

Abstract Preview: Purpose: To significantly improve image quality relative to clinically deployed digital breast tomosynthesis (DBT) systems, which use a 1D acquisition geometry (an arc), with a 2D image acquisition ge...

Development of a Visualization Tool for LET and Proton Spot Mapping for PB Treatment Planning

Authors: Chang Chang, Mohammad Kanber, Stephen Kenneth Northway

Affiliation: East Carolina University, California Protons Cancer Therapy Center, California Proton Cancer Therapy Center

Abstract Preview: Purpose:
Proton therapy treatment planning involves the consideration of unique physical quantities such as Linear Energy Transfer (LET) and spot location maps that do not exist in photon treatment...

Diffusion-Weighted MRI: An Early Biomarker for Treatment Response in MR-Guided Treatment of Rectal Cancer

Authors: Huiming Dong, Jonathan Pham, X. Sharon Qi, Ann Raldow

Affiliation: Department of Radiation Oncology, University of California, Los Angeles

Abstract Preview: Purpose: The study aimed to investigate longitudinal apparent diffusion coefficient (ADC) as an early biomarker of treatment response in patients with locally advanced rectal cancer (LARC) undergoing ...

Effects of Plan Optimization Techniques on Relative Biological Effective Dose in a Thin Intracranial Target Volume

Authors: Sean P. Boyer, Shae Gans, Mingcheng Gao, Draik B. Hecksel, Mark Pankuch

Affiliation: Northwestern Medicine Proton Center, Northwestern Medicine Chicago Proton Center

Abstract Preview: Purpose: Protons deposit a large portion of their energy at the end of their range in a region known as the Bragg peak, which may increase the relative biological effective (RBE) dose in this region. ...

Effects of Skin Gap and Applicator Tilt on Dose Coverage for Skin Lesions Treatment with Leipzig Applicator

Authors: Awens Alphonse, Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Nishan Shrestha

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: This study aims to quantify the dose discrepancy associated with improper placement of the Leipzig applicator on the patient's skin.
Methods: Monte Carlo simulations were performed using t...

Efficient Denoising of Low-Statistic Influence Matrices Using a Diffusion Transformer-Based Framework for Adaptive Proton Therapy

Authors: Yuzhen Ding, Hongying Feng, Jason Michael Holmes, Baoxin Li, Wei Liu, Daniel Ma, Lisa McGee, Samir H. Patel, Jean Claude M. Rwigema, Sujay A. Vora

Affiliation: Arizona State University, Department of Radiation Oncology, Mayo Clinic, Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose:
Intensity-modulated proton therapy (IMPT) is a preferred treatment modality for head and neck (H&N) cancer patients, offering precise tumor targeting while sparing surrounding organs at ri...

First in-Vivo Application of a Novel Precision Small Animal Irradiation Platform with Proton IMPT Delivery and Advanced on-Board Image-Guidance

Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf

Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital

Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...

Glandular Dose Map in Voxelized Phantoms across Advanced Breast Imaging Modalities Obtained from Monte Carlo Simulations

Authors: Rodrigo T Massera, Sofia Giaccone Thomaz, Alessandra Tomal, Giovanna Tramontin

Affiliation: Universidade Estadual de Campinas. Instituto de Física Gleb Wataghin, Department of Imaging & Pathology, unit of Medical Physics & Quality Assessment, KU Leuven

Abstract Preview: Purpose: Monte Carlo simulations are increasingly used in breast dosimetry for their precision in estimating difficult-to-measure quantities, such as glandular dose. With ionizing radiation in breast ...

Imaging Based Surveys to Identify Leaks and Gaps in Radioisotope and Fluoroscopic x-Ray Shielding Barriers for Improved Shielding of Hospital Workers.

Authors: Nicholas Borges, Steven Brown, Jerimy C. Polf

Affiliation: H3D, inc, Massachusetts General Hospital, M3D, Inc

Abstract Preview: Purpose: To evaluate the potential of using real-time imaging and dose measurement to find weak spots and leaks in bedside shielding systems during diagnostic or interventional fluoroscopic procedures...

Improvement of Spine Phantom for MR Imaging of the Spine

Authors: Richard Dortch, Thammathida Ketsiri, Zhiqiang Li, Shiv P. Srivastava

Affiliation: Barrow Neurological Institute, Dignity Health Cancer Institute, St. Joseph's Hospital & Medical Center

Abstract Preview: Purpose: Imaging the spinal cord post-surgery is challenging due to metal surgical implants, which induce signal loss and geometric distortions. Together, this hinders the visualization of the spinal ...

Improving Output Stability with Angular Correction Factor on Pencil Beam Scanning Proton System

Authors: Akbar Anvari, Carnell J. Hampton, Melanie R. Piantino, Kai Yang

Affiliation: Levine Cancer Institute, Atrium Health

Abstract Preview: Purpose: To evaluate the effectiveness of angular correction factor for output stability on Mevion S250i Hyper scanning machine, which allows user to apply correction factors for output at selected ga...

Investigation of a Novel Snout-Mounted Compton Camera System for Monitoring Dose Depth

Authors: Ananta Raj Chalise, Matthias K Gobbert, Hajar Moradmand, Sina Mossahebi, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma, Jie Zhang

Affiliation: University of Maryland School of Medicine, University of Maryland Baltimore County, University of Maryland, University of Maryland, Baltimore County, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc

Abstract Preview: Purpose: We are developing a novel Compton Camera (CC) system mounted orthogonally on the treatment nozzle for prompt gamma (PG) imaging-based proton range verification during treatment. This study in...

Isocenter Optimization for Linear Accelerator-Based Radiosurgical Treatment Planning for Multiple Brain Metastases

Authors: J. Daniel Bourland, Christina K Cramer, Justin M. Napolitano, James D. Ververs

Affiliation: Wake Forest University School of Medicine

Abstract Preview: Purpose:
Brain metastases (BM) can be treated with linear accelerator (LINAC)-based stereotactic radiosurgery (SRS). Treatment planning for this modality has evolved over time; treatment plans typi...

Medical Physics in the Oncoverse

Authors: Chandrasekhar Kota

Affiliation: Christiana Care Hospital

Abstract Preview: Purpose: To reflect on the present and future role of Medical Physics in the Oncoverse.
Methods: Oncoverse is the rapidly evolving and expanding ecosystem of all things related to cancer. The Medic...

Optimizing Minimum Monitor Unit Thresholds for Proton Breast Therapy on the Iba Proteusone

Authors: Chia-Lung Chien, Wen C. Hsi, Faraz Kalantari, Pouya Sabouri, Man Yam

Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
Reducing treatment delivery time is critical to improving patient throughput and minimizing the risk of intrafraction motion, which can compromise treatment accuracy. This study identifies...

Plastic Scintillating Detector Assisted Spot Mapping for Patient Specific Quality Assurance in Proton Beam Therapy

Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din

Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University

Abstract Preview: Purpose: This study introduces a novel approach for patient-specific quality assurance in proton beam therapy, utilizing new plastic scintillator detectors with high temporal resolutions to create det...

Spot Map Modification for Planning Optimization on a Spot Scanning Proton System with Adaptive Aperture

Authors: Austen N. Curcuru, Winter Green, Yao Hao, Jiayi Liu, Yuting Peng, Tiezhi Zhang, Xiandong Zhao

Affiliation: Washington University School of Medicine, Department of Radiation Oncology, WashU Medicine, Virginia Commonwealth University, Washington University School of Medicine, Washington University in St. Louis

Abstract Preview: Purpose: We proposed a treatment planning optimization method that utilizes customized spot map modification to achieve less dosimetry uncertainty, monitor unit ratio (MUR) and neutron dose in a spot ...

Streamlining Quad-Shot Radiotherapy: Automated Workflow Enables Same-Day Treatment for Palliative Lung Cancer

Authors: Laura I. Cervino, Sharif Elguindi, Yu-Chi Hu, Licheng Kuo, Xiaoning Liu, Jennifer Ma, Pengpeng Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Radiation Oncology, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
Quad-shot radiotherapy (QSRT) is an emerging paradigm in palliative cancer treatment. This study aimed to streamline the QSRT workflow using automation to improve efficiency while maintain...