An Evaluation of an SRS Quality Assurance System for Complex Patient Plans.

Authors: John Bennet, Indrin J. Chetty, Tai H. Dou

Affiliation: Department of Radiation Oncology,Cedars Sinai Medical Center, Department of Radiation Oncology, Cedars Sinai Medical Center, Department of Radiation Oncology,Cedars-Sinai Medical Center

Abstract Preview: Purpose:
To investigate the effect of complexity of stereotactic radiosurgery (SRS) volumetric modulated arc therapy plans on gamma pass rates (GPR) using a novel high-resolution ion chamber array ...

Automated Treatment Planning for Linac-Based Stereotactic Radiosurgery of Intraocular Malignancies Via Hyperarc Knowledge-Based Planning

Authors: Chase Cochran, Shane McCarthy, Damodar Pokhrel, William St Clair

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Manually generating intraocular stereotactic radiosurgery (SRS) plans involves significant challenges, including lengthy planning times and inter-planner variability. Knowledge-based SRS plan...

Clinical Experience with an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang

Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the clinical experience with ZapMU for independent second check of dose calculatio...

Clinical Feasibility of a Deep-Learning-Based Auto Contouring through Qualitative and Dosimetric Assessments

Authors: Sara Endo, Takeshi Fujisawa, Hidehiro Hojo, Masaki Nakamura, Hidenobu Tachibana

Affiliation: Department of Radiation Oncology, National Cancer Center Hospital East, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East

Abstract Preview: Purpose: To assess the clinical feasibility of deep learning (DL)-based automated contouring through qualitative and quantitative assessments.

Methods: Sixty cases were chosen, including 3 OARs...

Determine the Isocenter and Its Size for MR Linac Unity Part1: (U V) of Cax

Authors: Ting Chen, Siming Lu, Tanxia Qu, Hesheng Wang

Affiliation: NYU Langone Health

Abstract Preview: Purpose: This study, the first in a two-part series, aims to determine the isocenter position and size for the MR Linac UNITY, focusing on the central axis (CAX) alignment of its Multi-Leaf Collimator...

Development of a Deep Learning Model for Accurate Brain Dose Prediction in Multi-Target Stereotactic Radiosurgery Plan Evaluation

Authors: Wenchao Cao, Yingxuan Chen, Haisong Liu, Wenyin Shi, Wentao Wang, Lydia J. Wilson, Zhenghao Xiao

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: Multi-target stereotactic radiosurgery (SRS) planning poses challenges due to complex geometries, small target volumes, and steep dose gradients. Achieving a balance between target coverage a...

Dosimetric Evaluation of a Three-Dimensional Cubic Electronic Detector Array for Radiotherapy Linac Quality Assurance

Authors: Enzo Charles Aucca, Roger Challco, Andres M. Gonzales Galvez, Carmen SANDRA Guzman Calcina, Jimmy Hernandez-Bello, Modesto Montoya, Renzo Aaron Ocampo, Erick Paniagua, Miguel Alberto Risco-Castillo, Dante E. Roa, Renzo E. Romero, William Souza Santos, Mirko Salomón Alva Sánchez

Affiliation: Graduate Program in Information Technologies and Health Management, University of Porto AlegreFederal University of Health Sciences of Porto Alegre, Universidad Tecnologica del Peru, Pontificia Universidad Catolica del Peru, Electronic Engineering Department, Leonard Cancer Institute - Radiation Oncology, Universidad Nacional de Ingenieria, Universidad Nacional de Ingenieria, Electronic Engineering Department, Federal University of Sergipe, HRS Oncology International, Universidad Nacional Federico Villareal

Abstract Preview: Purpose: Provide Monte Carlo (MC) and experimental dosimetric assessments of a 3D cubic electronic detector array based on percent depth doses (PDDs), profiles, linearity, and dose rate response of ph...

Effects of Enhanced Leaf Modeling on Single-Isocenter Multi-Target Stereotactic Radiosurgery Dose Accuracy

Authors: Thomas R. Mazur, Kevin Renick, Matthew C. Schmidt, Xiaodong Neo Zhao

Affiliation: Washington University in St. Louis School of Medicine, Washington University School of Medicine

Abstract Preview: Purpose: To compare dose calculation accuracy for single-isocenter multi-target stereotactic radiosurgery plans (SIMT-SRS) in Eclipse V18.0 with enhanced leaf model (ELM) using the anisotropic analyti...

Establishing Comprehensive QA for Single-Isocenter Multiple Targets Stereotactic Radiosurgery

Authors: Angel Gomez, Titania Juang, Grace Gwe-Ya Kim, Boyu Meng

Affiliation: UC San Diego, UCSD, University of California San Diego

Abstract Preview: Purpose: Single-Isocenter Multiple Targets (SIMT) Stereotactic Radiosurgery (SRS) is widely used for its precision and effectiveness. However, standardized quality assurance (QA) protocols for SIMT SR...

Feasibility of Using a Dynamic-Platform with High-Resolution Patient-Specific QA Device for Periodic and Patient-Specific-QA in Respiratory-Gated Radiotherapy Lung SBRT Treatment

Authors: Tae Kyu Lee

Affiliation: Allina Health

Abstract Preview: Purpose: To assess the feasibility of a dynamic-platform integrated with high-resolution patient-specific-quality-assurance (PSQ device for periodic quality assurance (PQA) and PSQA in respiratory-gat...

Initial Three-Year Machine Performance Assessment of a Superficial Radiation Therapy Unit

Authors: Vibha Chaswal, Stephen D. Davis, Alonso N. Gutierrez, Noah S. Kalman, Yongsook C. Lee, William Romaguera, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose: To report machine performance of our superficial radiation therapy unit (SRT-100 Vision, Sensus Healthcare, Boca Raton, FL) for the first three years after commissioning of the unit.
Metho...

Monte Carlo Derived Correction Factors for Ion Chambers Used in the Calibration of Gamma Knife Perfexion Model: Impact of Phantom Materials and Chamber Orientation on Dosimetric Accuracy

Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: Commissioning of a Gamma Knife® (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...

Objective Verification of Mechanical and Radiation Isocenters Independent of Setup

Authors: Jonathan Dowell, Wei Luo, Shane McCarthy, Janelle A. Molloy, Markus Murphy

Affiliation: University of Kentucky, Department of Radiation Medicine, Iridesce Solutions, Inc.

Abstract Preview: Purpose: The novel machine quality assurance (QA) device nüFilm (Iridesce Solutions, Lexington KY) allows for an objective assessment of light and radiation fields independent of setup. Herein, the ab...

On the Development and Commissioning of an in-Vivo Dosimetry Program Using Small Pieces of Gafchromic Film

Authors: Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Gafchromic film is commonly used for quality assurance in SRS/SBRT. However, its application in low-dose measurements, such as monitoring doses on cardiac implantable electronic devices—where...

Proactive Quality Assurance for Adaptive Radiotherapy: Real-Time Mlc Verification with Myqa SRS

Authors: James L. Giltz, Michael J. Merrick

Affiliation: Alyzen Medical Physics, University of Kentucky

Abstract Preview: Purpose: To evaluate the capability of MyQA SRS in performing high-resolution machine QA to verify multileaf collimator (MLC) behavior and integrity for adaptive radiotherapy (ART). This study demonst...

Validation of SRS Mapcheck for Patient-Specific Quality Assurance of Cyberknife

Authors: Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, Tae Ho Kim, Sangmin Lee

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: The CyberKnife system, designed for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT), considers SRS MapCHECK an effective tool for patient-specific QA (PSQA). This wo...

Workflow for Same Day Linac-Based Stereotactic Radiosurgery

Authors: William Amestoy, Carolina Benjamin, Markus Bredel, Rodrigo Delgadillo, Nesrin Dogan, Michael E Ivan, Ricardo J Komotar, Gregory J. Kubicek, Eric Mellon, Ivaylo B. Mihaylov, Maria Irene Monterroso, Raymond A. Schulz, Ashish Shah, Robert M Starke

Affiliation: University of Miami, Department of Radiation Oncology, University of Miami, University of Miami Sylvester Comprehensive Cancer Center, Varian Medical Systems

Abstract Preview: Purpose: Stereotactic Radiosurgery (SRS) is a widely used treatment modality in radiation oncology, utilizing various technologies such as Gamma Knife (GK), Cyber Knife (CK) and Linac-based SRS with H...