A Comparative Analysis of Hand Calculations and Macro Monte Carlo Simulations for Electron Beam Dosimetry

Authors: Mohamed Eldib, Adam Mahl, Moyed Miften, Rachel Petragallo, Kelly L. Stuhr

Affiliation: University of Colorado - Anschutz Medical Campus, University of Colorado School of Medicine, University of Colorado Denver, Department of Radiation Oncology, University of Colorado

Abstract Preview: Purpose: To compare electron beam dose calculations performed manually with those computed using the Macro Monte Carlo simulation for standard fields on both phantom and patient setups, with the aim o...

A Comparative Analysis of the Dosimetric, Alignment, and Setup Efficiency in Left Breast Cancer Radiotherapy Treated with Dibh Using ABC and Sgrt

Authors: Aaron Conard, Victoria Croog, Marie Gurka, Lan Lin

Affiliation: Johns Hopkins University

Abstract Preview: Purpose:
This study evaluates the utility of the Active Breathing Coordinator (ABC) and Surface Guided Radiation Therapy (SGRT) techniques in implementing Deep Inspiration Breath Hold (DIBH) for le...

A Dosimetric Analysis between Surgically Targeted (STaRT) Radiation Therapy and External Beam Stereotactic Radiation Therapy for Glioblastoma Resection Cavities

Authors: Jamieson Baker, Emel Calugaru, Yijian Cao, Jenghwa Chang, Jessica Jung, Jian Liu, Cindy Pham, Anurag Sharma, John Starner, Ching-Ling Teng, Michael A. Trager, Gabriella Wernicke

Affiliation: Northwell, Northwell Health, Radiation Medicine, Northwell Health, Hofstra University Medical Physics Program

Abstract Preview: Purpose: Our hospital network has options to treat recurrent glioblastoma (GBM) with surgically targeted Cesium-131 brachytherapy, external beam stereotactic radiotherapy (SRT) with Varian TrueBeam, H...

A Framework for the Standardization of Radiomics Classes in the Presence of Blur and Noise

Authors: Huay Din, Grace Jianan Gang, Grace Hyun Kim, Michael F. McNitt-Gray, Joseph W. Stayman, Yijie Yuan

Affiliation: Johns Hopkins University, John Hopkins University, University of Pennsylvania, David Geffen School of Medicine at UCLA

Abstract Preview: Purpose:
Radiomics rely on quantitative features to discern underlying biological signatures. However, feature dependence on the imaging systems themselves hampers the creation of reproducible and ...

A Novel Linac Onboard Dual-Layer Kv Imager Provides Increased Clinical CBCT Contrast and Metal Artifact Reduction Using Virtual Monoenergetic Images

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Dual-energy imaging offers benefits, including metal artifact reductions (MAR) and improved contrast, that enhance visualization. Currently, dual-energy imaging is largely limited to CT scann...

A Novel Margin-Based Focal Distance Loss for Lesion Segmentation in Medical Imaging

Authors: Weiguo Lu, Hua-Chieh Shao, Guoping Xu, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
Neural network-based lesion segmentation remains a significant challenge due to the low contrast between lesions and surrounding tissues (high ambiguity) and the variability of lesion shap...

A Novel Non-Measured and DVH-Based IMRT QA Framework with Machine Learning for Instant Classification of Susceptible Lung SBRT VMAT Plans

Authors: Chuan He, Anh H. Le, Iris Z. Wang

Affiliation: Roswell Park Comprehensive Cancer Center, Cedars-Sinai

Abstract Preview: Purpose: To develop a non-measured and DVH-based (NMDB) IMRT QA framework integrating machine learning (ML) to classify lung SBRT VMAT plans prone to delivery errors
Methods: 560 Eclipse AcurosXB l...

A Python Package for GPU-Accelerated Photon Dose Calculation for Advanced and Generalizable Auto-Planning Approaches: Validation for Multiple Linear Accelerator Vendors and Institutions

Authors: Jaryd Ricardo Christie, Anthony J. Doemer, William T. Hrinivich, Junghoon Lee, Calin Reamy, Kundan S Thind

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Henry Ford Health

Abstract Preview: Purpose: To develop and validate an open-source Python package for fast, widely compatible, and user-friendly photon dose calculation algorithm through comparisons with clinical treatment planning sys...

A Real-Time 6 Degrees-of-Freedom Image Guided Radiation Therapy Technology Using Internal-External Motion Correlation Modelling

Authors: Jeremy T. Booth, Nicholas Hardcastle, Freeman Jin, Alicja Kaczynska, Paul J. Keall, Chandrima Sengupta

Affiliation: Northern Sydney Cancer Centre, Royal North Shore Hospital, Physical Sciences, Peter MacCallum Cancer Centre, Image X Institute, Faculty of Medicine and Health, University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney

Abstract Preview: Purpose: An ESTRO survey reported that 71% of radiotherapy centers across 41 countries want to implement real-time image guided radiation therapy (IGRT) to improve patient outcomes. To address this gl...

A Setup and Workflow for Fully Automated Electromagnetic Tracking-Based Implant Reconstruction in Intraoperative Prostate HDR Brachytherapy

Authors: Ioannis Androulakis, Miranda E.M.C. Christianen, Jérémy Godart, Mischa Hoogeman, Inger-Karine K. Kolkman-Deurloo, Lorne Luthart, Remi A. Nout, Henrike Westerveld

Affiliation: Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands, Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam

Abstract Preview: Purpose:
Despite the advantages of transrectal ultrasound-based treatment planning for HDR prostate cancer brachytherapy which allows on-line treatment delivery in the intraoperative setting, it is...

Accuracy Assessment of Bragg Peak Imaging Using Protoacoustics at a Clinical Dose

Authors: Michael Caulfield, Ye Chen, Yoshihiro Ishi, Yasutoshi Kuriyama, Taeko Matsuura, Naoki Miyamoto, Taichi Murakami, Tomonori Uesugi, Kohei Yokokawa

Affiliation: Hokkaido University, Kyoto University, University of Alberta

Abstract Preview: Purpose: Protoacoustics has the potential for real-time and direct imaging of the Bragg peak. This study investigated the accuracy of the Bragg peak imaging based on the water phantom experiment at a ...

An International Multi-Institutional Espresso Study of Developing the Specialized-Equipment-Free Remote Audit for Single-Isocenter Multi-Target Stereotactic Radiosurgery

Authors: Juan-Francisco Calvo-Ortega, Andrew Cousins, Ashley Cullen, Andrew Dipulia, Peter B. Greer, Seng Boh Gary Lim, Shih-Chi Lin, D. Michael Lovelock, Conor McGarry, Victoria Robinson, Cameron Stanton, Baozhou Sun, Ching-Ling Teng, Gemma Warner, Benjamin J. Zwan

Affiliation: Northern Ireland Cancer Centre, Baylor College of Medicine, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Christchurch Hospital, Northwell, Central Coast Cancer Centre, Calvary Mater Hospital, Hospital Quironsalud Barcelona, Icahn School of Medicine at Mount Sinai, Chris O'Brien Lifehouse, University of Newcastle

Abstract Preview: Purpose: This multi-institution Electronic Silicon-based Remote Survey of Small-field Output (ESPRESSO) study aims to develop the remote audit process to evaluate the safety of single-isocenter multi-...

An Open-Access Toolkit to Generate Realistic CT and Low-Field MR Images Based on an Xcat Phantom

Authors: Debora de Souza Antonio, Romy Guthier, Konrad Pawel Nesteruk, Erno Sajo, William Paul Segars, Gregory C. Sharp, Atchar Sudhyadhom, Hengyong Yu

Affiliation: Massachusetts General Hospital, Carl E. Ravin Advanced Imaging Laboratories and Center for Virtual Imaging Trials, Duke University Medical Center, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School,, Massachusetts General Hospital and Harvard Medical School, University of Massachusetts Lowell

Abstract Preview: Purpose: To develop an open-access toolkit for rapidly generating simultaneously realistic CT scans and low-field MR images of the abdominal region, based on patient data, while employing an XCAT phan...

Analysis of Orthopedic Metal Artifact Reduction’s (O-MAR’s) Effectiveness on Correcting Typical Anatomical Structure Average Volumetric Hounsfield Unit (AVHU) Values Due to High-Density Metal Artifacts

Authors: John T Barrett, Mehnaz Haque, Chulhaeng Huh, Shands James, Thomas B. Lavin, Anobel Maghsoodpour, Farshad Mostafaei, Austin Sanders

Affiliation: Department of Radiation Oncology, Augusta University, Department of Radiation Oncology, Medical College of Georgia, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health, Department of Radiation Oncology, Doctors Hospital of Augusta, Department of Radiology and Imaging, Augusta University

Abstract Preview: Purpose: This study assesses Philips’ O-MAR effectiveness in adjusting AVHU values of common anatomical materials affected by various high-density metal artifacts at varying distances.

Methods:...

Analyzing Backlight Runtime and Corresponding Performance in Diagnostic Displays

Authors: James Ward, Anzi Zhao

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: This study investigates the correlation between the backlight runtime in diagnostic displays and their corresponding performance, which may aid in making informed decisions regarding the timi...

Assessment of Practice Consistency for Management of Target Exposure Indices in Digital Radiography

Authors: Zachary Carr, Katie W. Hulme, Zaiyang Long, Nathan A. Quails, Ashley Tao

Affiliation: Gundersen Health System, Ohio State University Wexner Medical Center, Mayo Clinic, Ohio State Wexner Medical Center, The Cleveland Clinic

Abstract Preview: Purpose: Meaningful interpretation of deviation index (DI) in clinical practice relies on appropriately set target exposure indices (EIT). EIT values for a given exam-view can be derived from the medi...

Automating Protocol-Specific Chart Checking in Radiotherapy

Authors: Jiajin Fan, Ulrich Langner, Qiongge Li, Jian Liu, Wei Nie, Edwin Quashie

Affiliation: Brown University Health, Hofstra University Medical Physics Program, Inova Hospital, Inova Schar Cancer Institute, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose:
Chart checking in radiotherapy ensures treatment plans meet clinical and safety standards. For patients in clinical trials, protocol-specific requirements add complexity, making manual rev...

Characterizing the Stability of Upright CT for Proton Therapy

Authors: Brian Burger, Carri K. Glide-Hurst, John W. Hayes, Carson Hoffman, Minglei Kang, Jessica R. Miller, Jordan M. Slagowski, Yuhao Yan

Affiliation: Department of Human Oncology, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Leo Cancer Care

Abstract Preview: Purpose: The combination of upright CT and patient positioner for particle therapy present tremendous potential for high precision IGRT and online adaptive radiation therapy (ART), where reliable CT p...

Commissioning and Validation of Monaco Proton Treatment Planning System on a Compact Proton Therapy System

Authors: Shupeng Chen, Xiaoda Cong, Raymond Dalfsen, Rohan Deraniyagala, Xuanfeng Ding, James E. Dolan, Xiaoqiang Li, Jian Liang, Peilin Liu, An Qin, Martin Soukup, Craig Stevens, Xiangkun Xu, Weili Zheng

Affiliation: Corewell Health William Beaumont University Hospital, Corewellhealth William Beaumont University Hospital, William Beaumont University Hospital, Elekta, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Corewellhealth William Beaumont Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital

Abstract Preview: Purpose: To facilitate clinical use of the proton feature of Monaco treatment planning system(TPS), we commissioned and validated it on a compact proton therapy system.
Methods: Pencil Beam Scannin...

Commissioning of a Near Real-Time In Vivo Film Dosimetry System

Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...

Comparative Evaluation of Dosimetric Treatment Plan Quality for Truebeam, and Tomotherapy in Spatially Fractionated Radiation Therapy

Authors: Raghavendiran Boopathy, Mansoor Khan, Srinidhi Rajagopalan

Affiliation: University of Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: This study aims to evaluate and compare the dosimetric outcomes of spatially fractionated radiotherapy (SFRT) grid planning techniques using Varian Eclipse for a Varian Edge C-arm LINAC syste...

Comprehensive Evaluation of High-Performance Cone-Beam Computed Tomography on C-Arm and Ring-Gantry Linacs for Adaptive Radiation Therapy

Authors: Laura I. Cervino, Karen Episcopia, Hsiang-Chi Kuo, Sangkyu Lee, Seng Boh Gary Lim, Shih-Chi Lin, Grace Tang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: This study evaluated the performance of the HyperSight Cone-Beam Computed Tomography (CBCT) system on a TrueBeam C-arm LINAC (TB) and two Ethos ring-gantry LINACs (ES) for adaptive radiation ...

Computational Prototype Single-Channel Vaginal Cylinder with Integrated Filter to Address Dose Uniformity in High-Dose-Rate Brachytherapy for Endometrial Cancer

Authors: Brett Bocian, Patrick James Jensen, Luis Augusto Perles, Christopher J. Tien

Affiliation: Yale University School of Medicine, University of Miami, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose: Guidelines for dose prescriptions in endometrial cancer are based upon depth from the cylinder, traditionally 5 mm or 0 mm (i.e., surface). There are no current single-channel vaginal cylinde...

Decreasing the Dependence of CT Number on the Position in the Field-of-View Using Photon Counting Detector CT

Authors: Yanle Hu, Shuai Leng, Cynthia H. McCollough, Maryam Sadeghian, Joe Swicklik

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: The dependence of CT number on position in the field-of-view (FOV) imposes challenges in radiotherapy treatment planning. This study aims to decrease this dependence using photon counting det...

Deep Autoencoder for Ring Artifact Denoising in Photon-Counting CT

Authors: Magdalena Bazalova-Carter, James Day, Xinchen Deng

Affiliation: University of Victoria

Abstract Preview: Purpose:
Ring artifacts in Photon-Counting Computed Tomography (PCCT) images can degrade image quality. this study aims to suppress ring artifacts with a novel autoencoder-based framework that leve...

Deep Learning Aided Oropharyngeal Cancer Autoplanning

Authors: Mark Bowers, Gabriel Carrizo, Jimmy Caudell, Vladimir Feygelman, Kevin Greco, Christian Hahn, Jihye Koo, Kujtim Latifi, Fredrik Lofman, Jacopo Parvizi, Muqeem Qayyum, Caleb Sawyer

Affiliation: RaySearch Laboratories, Moffitt Cancer Center

Abstract Preview: Purpose: Head and neck (H&N) radiotherapy planning is complex, with multiple competing objectives. We endeavored to improve efficiency of planning by developing a deep learning (DL) model trained to p...

Deep Learning-Based Denoising for Template Matching in Real-Time Tumor Tracking Using Kv Scattered X-Ray Imaging

Authors: Weikang Ai, Xiaoyu Hu, Xun Jia, Kai Yang, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Department of Biomedical Engineering, Johns Hopkins University, Johns Hopkins University

Abstract Preview: Purpose: Real-time tumor tracking is critically important for respiratory motion management for lung cancer radiotherapy. A previously proposed application of a photon counting detector involves measu...

Deep-Learning Convolutional Neural Network-Based Breast Cancer Localization for Mammographic Images: A Study on Simulated and Clinical Images

Authors: Xiaoyu Duan, Xiang Li, Wenbo Wan, Lei Zhang, Yiwen Zhang

Affiliation: Duke University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: Breast screening has been proved to reduce breast cancer mortality by early detection and treatment for patients. Mammography is the most common and widely used technique for breast cancer sc...

Dependency of CT Number on Position in the Field-of-View for Single- and Multi-Energy Images Acquired with Energy-Integrating-Detector and Photon-Counting-Detector CT Scanners

Authors: Yanle Hu, Shuai Leng, Cynthia H. McCollough, Maryam Sadeghian, Joe Swicklik

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: To assess the dependency of CT numbers on position in the field-of-view (FOV) using single-energy (SE) and dual-energy (DE) images and energy-integrating detector (EID) and photon-counting de...

Deployable Twin-Calorimeter System for Absolute Dose Measurements By Clinical Physicists

Authors: Jean Dessureault, Malcolm R. McEwen, Bryan R. Muir, James Renaud

Affiliation: National Research Council

Abstract Preview: Purpose: To develop and commission a mailable calorimeter that enables clinical medical physicists to quickly and efficiently address innovative dosimetry challenges directly at the point of use.
<...

Determine the Isocenter and Its Size for MR Linac Unity Part1: (U V) of Cax

Authors: Ting Chen, Siming Lu, Tanxia Qu, Hesheng Wang

Affiliation: NYU Langone Health

Abstract Preview: Purpose: This study, the first in a two-part series, aims to determine the isocenter position and size for the MR Linac UNITY, focusing on the central axis (CAX) alignment of its Multi-Leaf Collimator...

Developing Metrics for Evaluating Machine Matching across Elekta Linear Accelerators in a Multicenter Clinic

Authors: Ashley Elizabeth Bonner, Michael G. Snyder

Affiliation: Corewell Health William Beaumont University Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital

Abstract Preview: Purpose: Develop and evaluate metrics for assessing beam matching of profiles across Elekta linacs in a multisite clinical setting.
Methods: Four Elekta linear accelerators (three VersaHD and one A...

Development of Patient-Specific Lead Ball Compensator for Total Body Irradiation

Authors: Chang Heon Choi, Minjae Choi, Yoonsuk Huh, Jin Jegal, Jung-in Kim, So-Yeon Park

Affiliation: Department of Radiation Oncology, Veterans Health Service Medical Center, Department of Radiation Oncology, Seoul National University Hospital

Abstract Preview: Purpose: Total Body Irradiation (TBI) aims to achieve a uniform dose distribution across the entire body. However, in conventional TBI setups that use extended source-to-surface distance (SSD) and lea...

Development of a Bayesian Network for a Comprehensive Uncertainty Assessment in Personalized Dosimetry after Targeted Radionuclide Therapy

Authors: NadÚge Anizan, David Broggio, Eric Chojnacki, Estelle Davesne, Didier Franck, Stéphanie Lamart, Alexandre Pignard

Affiliation: Institut Bergonié, Service de Physique Médicale, Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSE-SANTE/SDOS/LEDI, Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSE-SANTE/SDOS, Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSN-RES/SEMIA/LSMA

Abstract Preview: Purpose: To develop an innovative method enabling a comprehensive uncertainty budget associated to personalized absorbed doses for 177Lu-PSMA therapy and providing probability distributions of all dos...

Development of a Robust 3D-Ultrasound (3DUS) Quality Assurance (QA) Framework for a Real-Time Needle-Tracking System in HDR GYN Brachytherapy

Authors: Diandra Ayala-Peacock, Lindsey Hendricks Bloom, Oana I. Craciunescu, Julie A. Raffi, Megan K. Russ, Ryan Sanford, Rajesh Venkarataman

Affiliation: Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, Duke University Medical Center, Duke University, Eigen Health, Duke Univesity

Abstract Preview: Purpose: To establish a robust QA framework to characterize and ensure accuracy, reliability, and reusability of a transrectal ultrasound (TRUS)-based needle tracking system (NTS) for clinical HDR GYN...

Dosimeteric Parameter Evaluation of Digital Polycrystalline Semiconductor Dosimeters for Quality Assurance of High-Dose-Rate Brachytherapy

Authors: Woong Cho, Jin-Beom Chung, Moo-Jae Han, Sang Won Kang, Boram Lee

Affiliation: Department of Radiation Oncology, Seoul National University Boramae Medical Center, Department of Radiation Oncology, Seoul National University Bundang Hospital, Department of Radiation Oncology, Inha University Hospital

Abstract Preview: Purpose: This study aims to establish a digital quality assurance (QA) system for high-dose-rate (HDR) brachytherapy by evaluating self-developed polycrystalline semiconductor dosimeters (PSDs).
Me...

Dosimetric Evaluation of Comprehensive Motion Management in 1.5T MR-Linac for Real-Time Gated Radiotherapy

Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wah Kong, Ka Ki Lau, Pei-Xiong Li, Pak Hang Nam, Mei Yan Tse, Jierong Wang, Bin Yang, Siu Ki Yu, Jing Yuan, Chi To Yung, Shang Peng Felix Yung

Affiliation: Medical Physics Department, Hong Kong Sanatorium and Hospital, Research Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: Intrafraction motion management remains a major challenge in magnetic resonance-guided radiotherapy (MRgRT). The recent clinical release of an active motion management system aims to enhance ...

Emulating Human Perception of Low-Dose CT Image Quality Via Deep Generative Models

Authors: Jongduk Baek, Jooho Lee, Adam S. Wang

Affiliation: Stanford University, Yonsei University

Abstract Preview: Purpose: Optimizing the balance between radiation dose and image quality in computed tomography (CT) is important for minimizing patient X-ray exposure while maintaining diagnostic accuracy. While rad...

Enhanced Predictive Model for Toxicity and 3-Year Survival in HCC Patients Using Learning Health System Infrastructure and AI-Driven Statistical Profiling

Authors: Ameer Elaimy, Theodore Lawrence, Charles S. Mayo, Seyyedeh Azar Oliaei Motlagh, Benjamin S. Rosen

Affiliation: University of Michigan

Abstract Preview: Purpose: To analyze the impact of clinical features on short-term survival, toxicity, and poor outcomes in HCC patients treated with SBRT,using automated data aggregation and enhanced algorithms with ...

Enhancing Daily QC for Photon-Counting CT: Incorporating 40 keV VMI Evaluations with the ACR CT Phantom

Authors: Lakshmi Ananthakrishnan, Xinhui Duan, Liqiang Ren, Gary Xu, Kuan Zhang, Yue Zhang

Affiliation: Department of Radiology, UT Southwestern Medical Center, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose: Daily quality control (QC) programs for diagnostic CT include water CT number (HU), standard deviation (SD), and visual artifact evaluations. At our institution, 70 keV virtual monoenergetic ...

Enhancing Radiation Therapy Precision and Safety: The Role of Cherenkov Imaging in Clinical Practice.

Authors: Adi Robinson, Michael J. Tallhamer

Affiliation: Centura Health, AdventHealth Orlando

Abstract Preview: Purpose: This study aims to evaluate the integration of Cherenkov imaging into radiation therapy practices, focusing on its utility in enhancing treatment precision, patient safety, and clinical decis...

Estimation of Brain Tumor’s Intra-Fraction Movement during Radiosurgery Using Fiducial Markers on the Skin Surface – a Simulation Study

Authors: Damien C. Mathew, Brandon Hai Nguyen, Satwik Pani, Yoichi Watanabe

Affiliation: Minnespolis Radiation Oncology, Department of Radiation Oncology, University of Minnesota Medical School, Washington University

Abstract Preview: Purpose: To formulate a computational algorithm to quantify the tumor movement from the motion data of landmarks on the brain surface. To estimate the magnitude of tumor movement when the head makes a...

Evaluating Dose Variability in Bladder Contouring for MR-Guided Prostate Cancer Radiotherapy

Authors: Emily Helen Hayes, Chihray Liu

Affiliation: University of Florida

Abstract Preview: Purpose: To evaluate dosimetric discrepancies in bladder dose calculations among rigid, deformed, and manual contouring methods in prostate cancer patients and assess dose variations resulting from bl...

Evaluating Uncertainty Estimation Models for Clinical Integration of AI-Generated Radiotherapy Dose Distributions

Authors: Jacob S. Buatti, Kristen A. Duke, Malena Fassnacht, Neil A. Kirby, Parker New, Niko Papanikolaou, Arkajyoti Roy, Yuqing Xia, Michelle de Oliveira

Affiliation: The University of Texas San Antonio, UT Southwestern Medical Center, UT Health San Antonio

Abstract Preview: Purpose:
Quantifying and visualizing uncertainty is critical for building clinical trust in AI-generated dose distributions. This study evaluates Monte Carlo Dropout (MCD), Snapshot Ensemble (SE), ...

Evaluating the Efficacy and Efficiency of Spine Treatment Using Diagnostic CT

Authors: Sunil Mani, Ilakiya Raghavendiran, Vasanthan Sakthivel, Skanda Kabilan Swamy

Affiliation: Edmond Santa Fe High School, Edmnd Deer Creek High, Cancer Specialists of North Florida, Advanced Medical Physics

Abstract Preview: Purpose: Purpose/Objective(s): To evaluate and validate the dose calculation and delivery accuracy for patients planned using diagnostic CT
Methods: A total of forty-two patients with palliative sp...

Evaluation of Fractional Variability in High-Risk Clinical Target Volume (HR-CTV) during High-Dose-Rate Brachytherapy for Cervical Cancer: A Retrospective Analysis for Adaptive Treatment Planning.

Authors: Olubunmi Odunola Aregbe, Clara Ferreira, Margaret Reynolds, David A. Sterling, Jianling Yuan

Affiliation: University of Minnesota, University of Minnesota Physicians, Department of Radiation Oncology, University of Minnesota, Minneapolis

Abstract Preview: Purpose: To analyze volume changes in the high-risk clinical target volume (HR-CTV) during high-dose rate (HDR) brachytherapy for cervical cancer patients. The study aims to evaluate the trend and cor...

Evaluation of Hypersight CBCT Scanning Techniques for Motion Management in Online Adaptive Radiotherapy: A Comparative Study of Slow, Fast, and Averaged Scans

Authors: Fan Liu, Adam C. Riegel, Yi-Fang Wang

Affiliation: Columbia University Irving Medical Center

Abstract Preview: Purpose: HyperSight, Varian Medical Systems' latest CBCT technology, integrates rapid 6-second data acquisition with advanced iterative reconstruction, enabling precise real-time contouring and dose c...

Evaluation of Noise and Dose Efficiency in Clinical Photon-Counting CT Colonography with Tin Prefiltration

Authors: Xinhui Duan, Vivek Nair, Liqiang Ren, KyuHo Song, Vasantha Vasan, Kuan Zhang, Yue Zhang

Affiliation: Department of Radiology, UT Southwestern Medical Center

Abstract Preview: Purpose: Minimizing radiation dose is crucial in CT colonography (CTC) screening and diagnosis. Tin (Sn) prefiltration is readily incorporated into clinical photon-counting CT (PCCT) scanners, yet its...

Evaluation of Phosphorus-32 Source Uniformity Using Python Algorithm and Monte Carlo Simulation

Authors: Ana Laura Burin, Ilca Marli Moitinho Amaral Medeiros, Priscila Santos Rodrigues, Maria Elisa Chuery Martins Rostelato, Sabrina Spigaroli Sgrignoli, Ana Catarina Koka de Souza Silva, Carla Daruich Souza, Cristhian Ferreira Talacimon, Lara El Hajj Teodoro, Carlos Alberto Zeituni

Affiliation: IPEN - USP, IPEN - Instituto de Pesquisas Energéticas e Nucleares

Abstract Preview: Purpose: The uniform distribution of phosphorus-32 (32P) in beta sources is essential to ensure the accuracy of radiotherapy treatments, such as those for paravertebral cancer. This study evaluated th...

Evaluation of Potential Dosimetric Risks from Intra-Fractional Motion in Single-Isocenter Stereotactic Radiosurgery

Authors: Brian D. Casto, Mathew Y Kang, Lichung Ku, Samuel J Wang, Joseph B. Ying, Walker Ray Zimmerman

Affiliation: Salem Health Cancer Center, Salem Health

Abstract Preview: Purpose: Varian HyperArc is an advanced radiotherapy module designed to efficiently deliver high-quality multi-target stereotactic radiosurgery (SRS) treatment plans on Varian linacs. However, the int...

Evaluation of the Isopoint System for Coincidence of Radiation and Physical Isocenter Checks of Linear Accelerators

Authors: Peter Balter, Thomas Alexander Cuthbert, Weiliang Du, Song Gao, Nicholas Zacharopoulos

Affiliation: Aktina Medical Corp, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The purpose of this study is to evaluate the accuracy and reproducibility of a commercial product for verifying the size, location, and coincidence of physical isocenter (P_iso) and radiation...

Evaluation of the Reflexion X1 As a Standalone PET/CT Simulator for Treatment Planning and Treatment Adaptation

Authors: Chunhui Han, An Liu, William T. Watkins, Qiuyun Xu

Affiliation: Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: To evaluate the RefleXion X1 imaging system as a standalone positron emission tomography and computed tomography (PET/CT) simulator for radiotherapy treatment planning and adaptive re-plannin...

Exploiting the Glycerol CH2 Resonances for Estimating Relative Free Fatty Acid to Triglyceride Concentration Ratios

Authors: José Antonio Klautau Toffoli, Anthony G. Tessier, Atiyah Yahya

Affiliation: Department of Oncology, University of Alberta

Abstract Preview: Purpose: To demonstrate that magnetic resonance spectroscopy (MRS) methyl (≈0.9 ppm) to glycerol (≈4.1-4.3 ppm) resonance area ratios correlate with relative concentrations of free fatty acids to trig...

Exploring Quantifiable Features of the Fracture Healing Process

Authors: Jung Gyu Chi, Sungwook Choi, Don-Soo Kim

Affiliation: IAM ORTHOPAEDIC CLINIC, Boston Children's Hospital/Harvard Medical School, Massachusetts College of Pharmacy and Health Science

Abstract Preview: Purpose: To explore quantifiable parameters of the fracture healing process to aid physicians in determining the treatment plan for intramedullary nailing removal.
Methods: In contrast to conventio...

Feasibility of Using a Convolutional Neural Network to Predict Physician Evaluation of Synthetic Medical Images

Authors: Sofia Beer, Menal Bhandari, Alec Block, Nader Darwish, Joseph Dingillo, Sebastien A. Gros, Hyejoo Kang, Andrew Keeler, Rajkumar Kettimuthu, Jason Patrick Luce, Ha Nguyen, John C. Roeske, George K. Thiruvathukal, Austin Yunker

Affiliation: Data Science and Learning Division, Argonne National Laboratory, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago, Department of Computer Science, Loyola University of Chicago

Abstract Preview: Purpose: Artificial intelligence (AI) generated synthetic medical images are seeing increased use in radiology and radiation oncology. Physician observer studies are an ideal way to evaluate the usabi...

Foundation Model Guidance for CBCT-CT Image Registration in Radiotherapy

Authors: Hacene Azizi, Abderaouf Behouch, Nabil Maalej, Aamir Raja, Mohamed Lamine Seghier

Affiliation: Khalifa University Biomedical Engineering & Biotechnology, Laboratory of dosing, analysis and characterization in high resolution, Ferhat Abbas Setif 1 University, Khalifa University Physics Department, Khalifa University

Abstract Preview: Purpose:
To ensure accurate alignment of cone-beam computed tomography (CBCT) and computed tomography (CT) images for image-guided radiotherapy, this study evaluates a foundation model guidance fra...

Gradient-Based Radiomics for Outcome Prediction and Decision-Making in Personalized Ultra-Fractionated Stereotactic Adaptive Radiotherapy (PULSAR): A Preliminary Study

Authors: Michael Dohopolski, Jiaqi Liu, Hao Peng, Robert Timmerman, Zabi Wardak, Haozhao Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
This study introduces a gradient-based radiomics framework to enhance outcome prediction in Personalized Ultra-Fractionated Stereotactic Adaptive Radiotherapy (PULSAR) for brain metastases...

Iguard: A Fully Unsupervised Image-Guidance Anomaly Recognition and Detection Framework in CBCT-Guided Radiotherapy.

Authors: James M. Lamb, Dishane Chand Luximon, Jack Neylon, Rachel Petragallo, Moritz Ritter, Timothy Ritter

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, ETH Zurich, VCU Health System, Department of Radiation Oncology, University of Colorado

Abstract Preview: Purpose: Anomalies in cone beam computed tomography (CBCT) radiotherapy image guidance can signal treatment deviations. Repetitive review of setup image registrations by humans is inefficient, prone t...

Impact analysis of effective dose conversion factors from CT scanner models

Authors: Max Chen, Sean Marquardt, Ben Yang, Kai Yang

Affiliation: Cary Academy, Massachusetts General Hospital, Winchester High School

Abstract Preview: Purpose: To analyze the impact of scanner model variation on the effective dose conversion factor (“k-factor”), which is most commonly used for CT effective dose calculation.

Methods: The stand...

Impact of Jaw Reproducibility and Source Occlusion on Small Field Dosimetry

Authors: Mylinh Dang, Indra J. Das, George X. Ding, Ahtesham Ullah U Khan, Andrew J. White

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Northwestern Medicine, Vanderbilt University Medical Center

Abstract Preview: Purpose: The large variability in field output factor (FOF) observed among various studies is speculated to be due to uncertainty in jaw reproducibility that is linked directly with source occlusion. ...

Impact of a Dedicated Working Group on Standardization of CT-Guided Adaptive Radiation Therapy

Authors: Anthony J. Doemer, Aharon Feldman, Ian Gallagher, Yimei Huang, Brett M. Miller, Benjamin Movsas, Kundan S Thind

Affiliation: Henry Ford Health

Abstract Preview: Purpose: CT-guided adaptive radiation therapy (CTgART) is a technical, resource intensive, procedure that involves many different radiation oncology team members. To ensure consistent, high-quality CT...

Improved Setup Accuracy for Dibh Whole Breast Radiotherapy with Surface-Guided Radiation Therapy

Authors: CheukKai Becket Hui, Goldie M. Klein, Yildirim D. Mutaf, Amir Pourmoghaddas

Affiliation: UC Health, Kaiser Permanente

Abstract Preview: Purpose:
In this study, we investigated the effect of SGRT (Align-RT) implementation on patient setup accuracy for DIBH breast radiotherapy treatments.
Methods:
We extracted vertical post-ima...

Improving Quantitative Accuracy of Maximum-a-Posteriori Expectation Maximization Reconstruction By Optimizing Gibbs Prior Parameters in SPECT

Authors: Krishnendu Saha

Affiliation: Cleveland Clinic Foundation

Abstract Preview: Purpose: The goal is to improve quantitative accuracy of a Maximum-a-posteriori expectation maximization (MAPEM) reconstruction of SPECT phantom images by optimizing Gibbs prior parameters.
Methods...

Initial Three-Year Machine Performance Assessment of a Superficial Radiation Therapy Unit

Authors: Vibha Chaswal, Stephen D. Davis, Alonso N. Gutierrez, Noah S. Kalman, Yongsook C. Lee, William Romaguera, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose: To report machine performance of our superficial radiation therapy unit (SRT-100 Vision, Sensus Healthcare, Boca Raton, FL) for the first three years after commissioning of the unit.
Metho...

Innovative Deep Learning Network for Overall Survival Prediction for NSCLC: Outperforming Pre-Trained Models VGG16 and ResNet50

Authors: Ryan Alden, Tithi Biswas, Kaushik Halder, Felix Maria-Joseph, Michael Mix, Rihan Podder, Tarun Kanti Podder

Affiliation: SUNY Upstate Medical University, IIT-Roorkee, University of Florida

Abstract Preview: Purpose: Early-stage NSCLC patients undergoing SBRT often die due to intercurrent illnesses. However, prediction of overall survival (OS) remains crucial due to the risk of disease recurrence. This st...

Intelligent Black Box Recording for Radiation Therapy: Feasibility Study of Vision-Language Models for Treatment Monitoring.

Authors: Wookjin Choi, James M. Lamb, David Romanofski, David H. Thomas, Yevgeniy Vinogradskiy

Affiliation: Drexel, Department of Radiation Oncology, University of California, Los Angeles, Thomas Jefferson University

Abstract Preview: Purpose: To develop an intelligent Black Box Recorder for radiation therapy (RT) that monitors patient treatments using a vision language model.
Methods: The system captures synchronized screen rec...

Inter-Fractional Target Similarity during Tandem and Ring HDR Brachytherapy

Authors: Olubunmi Odunola Aregbe, Clara Ferreira, Margaret Reynolds, David A. Sterling

Affiliation: University of Minnesota, University of Minnesota Physicians, Department of Radiation Oncology, University of Minnesota, Minneapolis

Abstract Preview: Purpose: Current best practices recommend daily imaging and planning for Tandem and Ring (T&R) HDR patient plans. Accurate target delineation is a critical, yet time consuming step in this process. Th...

Investigating Factors Impacting the Consistency of Signal-to-Noise Ratio in Mammographic Automatic Exposure Control

Authors: James Ward, Anzi Zhao

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: This study investigates the impact of tissue-equivalent attenuator materials, the region of interest (ROI) size, and the orientation of the attenuator positioning on the measured signal-to-no...

Investigating Interstitial Fluid Pressure and Hydraulic Conductivity By Examining the Biophysical Properties of Drug Transport Using Cross Voxel Exchange Model and Dynamic Contrast Enhanced MRI

Authors: Catherine Coolens, Janny Yeyoung Kim, Michael Milosevic, Noha Sinno

Affiliation: Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: In solid tumors, Interstitial fluid pressure (IFP) acts as a barrier to molecular transport to the tumor center and serves as a predictor of cancer patients’ treatment responsiveness. The nov...

Investigation of Fluorescent Probes for Real-Time ROS Detection Under Flash Radiotherapy

Authors: Yuqi Yang, Fang-Fang Yin

Affiliation: Duke Kunshan University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: Reactive oxygen species (ROS) are unstable molecules which play important roles in the cellular process after Flash radiotherapy. The rapid changes in ROS levels during treatment may provide ...

Investigation of Metallic Artefact Reduction Capabilities of Hypersight Enabled Platforms

Authors: Harald Keller, Iymad Mansour, Jeff D. Winter

Affiliation: Princess Margaret Cancer Centre

Abstract Preview: Purpose: The growing number of adaptive therapy applications is motivating image segmentation and direct dose calculation on CBCT. The purpose of this investigation is to evaluate the recently release...

Knowledge-Based Three-Dimensional Dose Prediction for High Dose Rate Prostate Brachytherapy

Authors: Mojtaba Behzadipour, Suman Gautam, Tianjun Ma, Ikchit Singh Sangha, Bongyong Song, William Song, Kumari Sunidhi

Affiliation: UC San Diego, Virginia Commonwealth University

Abstract Preview: Purpose: This study aims to develop a knowledge-based voxel-wise dose prediction system using a convolutional neural network (CNN) for high-dose-rate (HDR) prostate brachytherapy and to evaluate its p...

Lesion Detection in Contrast Enhanced Cone Beam Breast CT with a Photon Counting Detector: A Monte Carlo Study

Authors: Ahad Ollah Ezzati, Xiaoyu Hu, Xun Jia, Youfang Lai, Kai Yang, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University

Abstract Preview: Purpose: Contrast-enhanced breast cone-beam computed tomography (bCBCT) provides high-resolution, 3D imaging of breast tissues with improved differentiation between normal and abnormal tissues. Curren...

Long-Term Stability Assessment of an Imaging Ring System Using One Year of Monthly Quality Assurance Data

Authors: Awens Alphonse, Nebi Demez, Brian P. Laffey, Shyam Pokharel, Suresh Rana, Nishan Shrestha

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: The Imaging Ring is a mobile digital X-ray system capable of producing 2D planar X-rays, fluoroscopy, and 3D Cone-Beam Computed Tomography (CBCT) images. This study aimed to evaluate the long...

Lung-Equivalent Compressible Material As Core Component for a Miniaturized Breathing Phantom Prototype

Authors: Silvia Calusi, Lucia Cavigli, Alberto Dalla Mora, Laura Di Sieno, Giacomo Insero, Riccardo Lisci, Livia Marrazzo, Cosimo Nardi, Stefania Pallotta, Andrea Profili, Fulvio Ratto, Giovanni Romano, Michaela Servi, Immacolata Vanore, Yary Volpe

Affiliation: Italian National Research Council IFAC-CNR, Institute of Applied Physics, Department of Physics, Politecnico di Milano, Department of Agricultural Food and Forestry System, University of Florence, Medical Physics Unit, Azienda Ospedaliero-Universitaria Careggi, Department of Industrial Engineering, University of Florence, Department of Experimental and Clinical Biomedical Sciences “Mario Serio”, University of Florence

Abstract Preview: Purpose: To develop a multi-purpose lung phantom prototype to replicate respiratory dynamics and morphological features observed in clinical radiological (CT and MR) imaging of lung parenchyma.
Met...

Minimizing Positioning Errors in Intracranial SRS: The Role of Verification Imaging after 6-Dof Corrections

Authors: Anthony J. Doemer, Yimei Huang, Benjamin Movsas, Ellen Park, Mira Shah, Salim Siddiqui, Karen C. Snyder, Kundan S Thind, Bo Zhao

Affiliation: Henry Ford Health

Abstract Preview: Purpose: The 6 degrees-of-freedom (6-DoF) robotic couch is considered essential for linac-based stereotactic radiosurgery (SRS), particularly for irregularly shaped targets adjacent to critical organs...

Mitigating Data-Driven Uncertainty in Machine Learning-Based Radiotherapy Outcome Prediction

Authors: Ali Ajdari, Alice Bondi, Thomas R. Bortfeld, Gregory Buti, Xinru Chen, Zhongxing Liao, Antony John Lomax, Ting Xu

Affiliation: The University of Texas MD Anderson Cancer Center, Department Of Radiation Oncology, Massachusetts General Hospital (MGH), Massachusetts General Hospital & Harvard Medical School, Paul Scherrer Institut, ETH Zurich

Abstract Preview: Title: Addressing Imaging and Biomarker-driven Uncertainty in Machine Learning-based Radiotherapy Outcome Prediction
Alice Bondi, Gregory Buti, Antony Lomax, Thomas Bortfeld, Xinru Chen, Ting Xu, Z...

Modeling Alpha-Particle Dose from Diffusing Alpha-Emitters Radiation Therapy in Tissue with Inhomogeneous Diffusion

Authors: Lior Arazi, Gil'ad N. Cohen, Antonio L. Damato, Irene P. Zhang

Affiliation: Unit of Nuclear Engineering, Faculty of Engineering Sciences, Ben-Gurion University of the Negev, NYU Grossman School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Diffusing alpha-emitters Radiation Therapy (“Alpha DaRT”) is a promising new radiation therapy modality for treating bulky tumors. The dose delivered by Alpha-DaRT sources is dependent on the...

Multicentric Characterization of Organ-Based Tube Current Modulation in Thoracic and Abdominopelvic Computed Tomography: A Dosimetric and Image Quality Study

Authors: Corentin Desport, Dominique Iacchetti, Nicolas Kien, Ramiro Moreno, Melodie Munier, Séléna Pondard

Affiliation: Fibermetrix, Alara Expertise, Alara Group

Abstract Preview: Purpose: To evaluate the efficiency of organ-based tube current modulation (OBTCM) in thoracic and abdominopelvic Computed Tomography (CT) for different radiology departments and manufacturers. This s...

Noise Sensitivity of Benchmark Whole-Body CT Segmentation Models: Totalsegmentator and Vista3D Performance on an Independent Dataset

Authors: Samuel L. Brady, Shruti Hegde, Alexander Knapp, Usman Mahmood, Joseph G. Meier, Elanchezhian Somasundaram, Zachary Taylor

Affiliation: Cincinnati Children's Hospital Medical Ctr, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Cincinnati Children's Hospital Medical Center, Cincinnati Childrens Hospital Med Ctr

Abstract Preview: Purpose:
To assess how two benchmark multi-organ CT segmentation models respond to varying image noise levels.
Methods:
This study utilized the pediatric CT dataset from The Cancer Imaging Ar...

Normal Tissue Dosimetry during Intra-Cavitary HDR Brachytherapy

Authors: Palanisamy Karunanithi, Karthikeyan Perumal, Siva Subramanian Vadivel

Affiliation: Dr. Kamakshi Memorial Hospital

Abstract Preview: Purpose:
Recent advancements in high dose-rate (HDR) brachytherapy include the image guidance, new applicators, and dose calculation algorithms. Brachytherapy has steep dose gradient, hence relativ...

Novel AI-Powered Tool to Objectively Evaluate Brain Dose for Multi-Met Stereotactic Radiosurgery Optimization

Authors: Wenchao Cao, Yingxuan Chen, Haisong Liu, Richard A. Popple, Wenyin Shi, Rodney J. Sullivan, Wentao Wang, Lydia J. Wilson, Zhenghao Xiao

Affiliation: Thomas Jefferson University, The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: Objectively evaluating brain sparing as a plan-quality indicator for patients receiving stereotactic radiosurgery (SRS) to multiple metastases (multi-met) is complicated by variability in tar...

Novel Fast Cone-Beam CT for Adaptive Radiotherapy: Assessment of Image Distortion, Auto-Contouring, and Dose Delivery Accuracy in the Presence of Periodic Subject Motion

Authors: David P. Adam, William T. Hrinivich, Taoran Li, Alexander Lu, Michael Salerno, Alejandro Sisniega, Boon-Keng Kevin Teo

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, University of Pennsylvania

Abstract Preview: Purpose: Cone beam CT (CBCT)-guided online adaptive radiotherapy (ART) is of growing interest, with recent improvements in image quality provided through larger detector panels and fast gantry rotatio...

Optimal Choice of Companion Radiotracer for TAT 225Ac-Mti-201.

Authors: Vinay K Banka, Mikalai Budzevich, William R. Gibbons, Mark L. McLaughlin, Jacob Moriarty, Eduardo G. Moros, David L. Morse, Christopher J. Tichacek, Thad J. Wadas

Affiliation: Modulation Therapeutics Inc, Moffitt Cancer Center, University of Iowa

Abstract Preview: Purpose: A targeted alpha therapy drug, 225Ac-MTI-201, has been developed targeting the Melanocortin 1 Receptor for metastatic uveal melanoma and is currently in FIH clinical trials. Since alpha emiss...

PET Imaging and Novel Cardiac Radiomics to Predict Pre-Radiotherapy Cardiac Conditions for Lung Cancer Patients Undergoing Radiotherapy.

Authors: Wookjin Choi, Michael Dichmann, Adam Dicker, Nilanjan Haldar, Yingcui Jia, Nicole L Simone, Eugene Storozynsky, Yevgeniy Vinogradskiy, Maria Werner-Wasik

Affiliation: Thomas Jefferson University, 9Department of Radiation Oncology, Thomas Jefferson University

Abstract Preview: Purpose: Cardiotoxicity remains a significant limitation for lung cancer patients treated with radiotherapy. Pre-radiotherapy cardiac conditions increase the probability of patients developing cardiot...

Parameterized 4D Deformable Registration (p4Dreg) in Abdominal 4DCT Scans

Authors: Edward Robert Criscuolo, Deshan Yang

Affiliation: Duke University, Department of Radiation Oncology, Duke University

Abstract Preview: Purpose:
Deformable registration of 4DCT images has many clinical applications, but current methods are unreliable and can produce dangerous errors. Iterative, parametrized image registration does ...

Performance Evaluation of End-of-Life Epid Panel Utilizing Automated Quality Assurance Test Suite

Authors: Michael Paul Barnes, Lana C. Critchfield, John J. DeMarco, Ellie Durussel, Nilendu Gupta, James Irrer, Peyton Jensen, Grace Gwe-Ya Kim, Cory S. Knill, Seng Boh Gary Lim, Justin K. Mikell, Jean M. Moran, Seyyedeh Azar Oliaei Motlagh, Mario Perez, Michael Pillainayagam, Claire Zhang

Affiliation: University of Michigan, Department of Radiation Oncology, University of Michigan, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Washington University School of Medicine in St. Louis, University of California San Diego, Royal North Shore Hospital, Calvary Mater Hospital Newcastle, Cedars-Sinai Medical Center

Abstract Preview: Purpose: EPIDs are widely used in linac QA due to their efficiency and accuracy. As EPIDs age, performance degradation may occur, potentially compromising reliability of EPID-based automated QA result...

Post-Implant Dosimetry (PID) between 1D and 2D Cs-131 Seed Models for Post-Op Cavities in Recurrent GBM Patients

Authors: Cindy Pham, Anurag Sharma, John Starner, Ching-Ling Teng, Michael A. Trager, Gabriella Wernicke

Affiliation: Northwell, Northwell Health, Radiation Medicine, Northwell Health

Abstract Preview: Purpose: Precisely identifying orientation of implanted seeds on post-implant CTs is challenging. This research addresses the dosimetric uncertainties stemming from uncertainties in identifying seed o...

Predicting CBCT-Based Adaptive Radiation Therapy Session Duration Using Machine Learning

Authors: Leslie Harrell, Sanjay Maraboyina, Romy Megahed, Maida Ranjbar, Xenia Ray, Pouya Sabouri

Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), University of California San Diego

Abstract Preview: Purpose: Real-time adaptive radiation therapy (ART) dynamically modifies patients’ treatment plan during delivery to account for anatomical and physiological variations. Addressing ART planning time v...

Predicting Elective Pelvic Nodal Volumes with Deep Learning: A Tool to Facilitate Peer Review

Authors: Brian M. Anderson, Shiva K. Das, Meagan Foster, Anirudh Karunaker, Lawrence B. Marks, Lukasz Mazur, Michael Repka

Affiliation: UNC Chapel HIll, University of North Carolina at Chapel Hill, UNC School of Medicine, University of North Carolina

Abstract Preview: Purpose: Development of a peer review segmentation check system to identify deviations in physician contours of standard risk pelvic lymph nodes in patients receiving radiation therapy for prostate an...

Prior-Informed Neural Super-Resolution Dosimetry for Radiotherapy QA from Sparse Dosimeter Arrays

Authors: Muhammad Ramish Ashraf, Clinton Gibson, Gregory Szalkowski, Lei Wang, Siqi Wang, Lei Xing

Affiliation: Department of Radiation Oncology, Stanford University, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University

Abstract Preview: Purpose: To develop a neural network-based super-resolution framework for enhancing the resolution of sparse dosimetry measurements in patient-specific radiotherapy QA. Sparse detector arrays, such as...

Quantitative Accuracy in Iodine Measurements and CT Numbers Using Standard and Ultra-High Resolution Photon-Counting CT in Coronary CTA

Authors: Afrouz Ataei, Victor Moy, Mark P. Supanich

Affiliation: Rush University

Abstract Preview: Purpose: To evaluate iodine quantification and CT number accuracy in coronary CT angiography (CTA) using standard and ultra-high resolution (UHR) modes of photon-counting CT (PCCT) across different do...

Quantitative Image Review Metric for Vertebral Body Misalignment

Authors: Luis E. Fong de los Santos, Douglas John Moseley, Satomi Shiraishi, Cenji Yu

Affiliation: Mayo Clinic

Abstract Preview: Purpose: To quantitatively detect errors in vertebral body localization using normalized cross correlation (NCC)

Methods: Volumetric images of a thoracic end-to-end SBRT phantom with a removabl...

Real-Time Output Gating and Fault Handling for an Uhdr Mobetron

Authors: Petr Bruza, David J. Gladstone, Lesley A Jarvis, Austin Sloop, Kevin J. Willy, Rongxiao Zhang

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose:
Active beam monitoring and output-gated dosimetry are essential systems for safe and accurate radiation delivery. UHDR irradiators such as the Mobetron rely on pre-programmed regimes and t...

Routine Quality Monitoring in Abdominal CT Using Global Noise Reference Levels in a 4-Parameter Protocol Summary Plot

Authors: Joke Binst, Hilde TC Bosmans, Niki Fitousi, Bram Miseur, Dimitar Petrov, Kwinten Torfs, Janne Vignero

Affiliation: Qaelum NV, Department of radiology, UZLeuven, Department of imaging and pathology, KULeuven

Abstract Preview: Purpose: Routine quality monitoring in CT abdomen is crucial for ensuring optimal image quality and patient safety, but the simultaneous evaluation of all aspects of importance is challenging. The pur...

Signal-to-Noise Ratio Estimation from Polynomial Fitting of Acr MRI Phantom Images

Authors: Alex Lindgren-Ruby, Jeffrey M. Moirano, Joseph Everett Wishart

Affiliation: University of Washington

Abstract Preview: Purpose:
To evaluate polynomial fitting of signal intensity for signal-to-noise ratio (SNR) estimation from weekly QC ACR MRI phantom images and compare against other SNR estimation methods as well...

Sources of Variability in Evaluating Ultrasound Imaging Performance Using Randomly-Distributed Hypoechoic Sphere Phantom

Authors: Cristel Baiu, Zheng Feng Lu, Dufan Wu, Baihui Yu

Affiliation: University of Wisconsin, Massachusetts General Hospital, University of Chicago

Abstract Preview: Purpose: IEC TS 62791:2022 specified a clinically meaningful and quantitative framework for evaluating diagnostic ultrasound performance by measuring the lesion signal-to-noise ratio (LSNR) using rand...

Spectral CT Assessment of 3D Printing Techniques for Improving the Uniformity and Reproducibility of Models Applied in Medical Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: Filament deposition modeling (FDM) 3D printers may utilize proprietary calibration methods inadequate for medical imaging. Proper techniques are necessary to achieve imaging uniformity standa...

Streamlining Quality Control for Radiographic and Fluoroscopic Systems

Authors: Caroline Cheney, Patricia G Collins, Allen R. Goode, Preston Le, Andrew M. Polemi, Angela Snyder

Affiliation: UVA Health, Atirix Medical Systems

Abstract Preview: Purpose: Optimize ongoing quality control (QC) for radiographic (DR) and fluoroscopic (FL) systems by identifying metrics most sensitive to hardware disruptions among regional noise, pooled noise, sig...

Synthetic Vs. Conventional Planar Imaging: Performance and Clinical Feasibility

Authors: Jennifer Kwak, Chelsea Manica, Justin K. Mikell, Michael Silosky, Wendy Siman

Affiliation: Washington University School of Medicine in St. Louis, University of Colorado Anschutz Medical Campus, School of Medicine, Rocky Vista University

Abstract Preview: Purpose:
This study evaluates synthetic planar imaging (synP) from SPECT projections against conventional planar imaging, focusing on detectability, spatial resolution, and feasibility. SynP allows...

Task-Specific Deep-Neural-Network Architecture Optimization for CBCT Scatter Correction

Authors: Hoyeon Lee

Affiliation: University of Hong Kong

Abstract Preview: Purpose: Deep-learning approaches are widely investigated for Cone-Beam CT (CBCT) scatter correction to improve the quality of the linear-accelerator mounted CBCT. This study aims to optimize the deep...

Technical Feasibility and Accuracy of Dynamic Longitudinal Couch Motion during Beam Delivery

Authors: Chonthicha Bunchuailuea, David Geeler, Martin Sabel, Claas Wessels

Affiliation: Varian Medical Systems

Abstract Preview: Purpose: Elongated treatment sites, such as craniospinal treatments, pose multiple challenges in today’s practices, requiring multiple CBCTs for position verifications per fraction, which might increa...

The Biological TCP/NTCP Modelling on Oropharyngeal Head-and-Neck Cancer for Patients Treated with Proton Beam Therapy

Authors: Wen C. Hsi, Tae Kyu Lee, Biniam Yo Tesfamicael

Affiliation: Allina Health, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Oklahoma Proton Center

Abstract Preview: Purpose: When minimal dose-variations induced by inter-fractional anatomical-changes and positioning-deviation were found for having limited impact on clinic-outcomes of oropharyngeal head-and-neck (H...

The CT Calibration for Proton Pencil Beams System

Authors: Xiangli Cui, Wanli Huo, Jie Li, Lingling Liu, Tao Ma, Yuanyuan Wang

Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Ion Medical Center, Hefei Cancer Hospital, Chinese Academy of Sciences, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University

Abstract Preview: Purpose: In practice, treatment planning systems (TPS) of proton therapy require a CT calibration curve, which relates Hounsfield units (HU) to relative stopping power (RSP). Single-energy CT as a sta...

The GYN Webapp: A Centralized Tool for Enhancing HDR Brachytherapy Treatment Quality and Clinical Outcomes

Authors: Kevin Albuquerque, Ti Bai, Yesenia Gonzalez, Brian A. Hrycushko, Zohaib Iqbal, Paul M. Medin, Shanshan Tang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Cervical cancer remains one of the most common and significant gynecological (GYN) malignancies globally, often presenting at advanced stages where radiation therapy and high-dose-rate (HDR) ...

The Impact of Intempo Imaging on Cyberknife Prostate Plans

Authors: Lei Fu, Eric Gressen, Yingcui Jia, Shari Rudoler, Yevgeniy Vinogradskiy, Qianyi Xu

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: InTempo imaging in the Accuray CyberKnife System improves the ability to track/correct target motion during treatment. However, no studies have provided information on the impact of InTempo I...

Towards Real-Time Marker-Less Prostate Tracking on Standard Radiation Therapy Systems

Authors: Freeman Jin, Paul J. Keall, Alistair MacDonald, Adam Mylonas, Chandrima Sengupta

Affiliation: Image X Institute, Faculty of Medicine and Health, University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney, Image X Institute, School of Health Sciences, University of Sydney

Abstract Preview: Purpose: During radiation therapy, tumours in the prostate may move from the planned treatment position, leading to significant dose deviations above clinical tolerances Surveys have indicated the nee...

Two's Company, Three's a Crowd? a Bayesian Approach to Optimizing the Number of Measurement Readings in Radiation Therapy QA

Authors: Siyong Kim, Ava Paek, Joseph B. Schulz, James J. Sohn, Eric D. Stolen, Ethan D. Stolen

Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Central Florida, Virginia Commonwealth University, Department of Radiation and Cellular Oncology, University of Chicago, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: The American Association of Physicists in Medicine Task Group 142 (AAPM TG-142) guidelines recommend three measurements during monthly quality assurance to keep results within two standard de...

Uncertainties on Synthetic-CT Generation from CBCT: Another Layer of Complexity in Abdominal Adaptive Radiotherapy

Authors: Laura I. Cervino, Wendy B. Harris, Paulo Quintero, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To evaluate the impact of the prediction uncertainty from CBCT-based synthetic CT (sCT) generation in abdominal adaptive radiotherapy.

Methods: CT and CBCT images from 65 abdominal pat...

Using Radiotherapy Dose Accumulation Routine (RADAR) for Deformable Offline Adaptive Head and Neck Dose Accumulation

Authors: Shira Abraham, Eric Aliotta, Michalis Aristophanous, Laura I. Cervino, Yu-Chi Hu, Phillip G. Lichtenwalner, Chuan Zeng, Pengpeng Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
We have developed a tool that uses deformable image registrations to perform deformable dose accumulation. In this work we evaluate use of this tool for adaptive head and neck dose accumul...

Validation of Synthetic CT-Based Online Monitoring for Adaptive Proton Therapy

Authors: Ozgur Ates, Chin-Cheng Chen, Chia-Ho Hua, Matthew J. Krasin, Thomas E. Merchant

Affiliation: St. Jude Children's Research Hospital

Abstract Preview: Purpose: To validate the use of synthetic CTs generated from CBCT images for online monitoring, ensuring accurate and reliable daily plan quality assessments in adaptive proton therapy (APT).
Metho...

Validation of a Novel Dielectric Layer-Based Detector for Linear Accelerator Quality Assurance

Authors: Dong Wook Kim, Jin Sung Kim, Dongho Lee, Sangmin Lee

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Korea, Republic of (South)

Abstract Preview: Purpose:
This study aims to analyze the characteristics of a novel detector based on a dielectric layer (Vieworks Co., Korea), which demonstrates high tolerance to high radiation doses and light tr...