Search Submissions 🔎

Results for "state space": 15 found

BEST IN PHYSICS IMAGING: Cross-Contrast Diffusion: A Synergistic Approach for Simultaneous Multi-Contrast MRI Super-Resolution

Authors: Yifei Hao, Wenxuan Li, Xiang Li, Tao Peng, Yulu Wu, Fang-Fang Yin, Yue Yuan, Lei Zhang, Yaogong Zhang

Affiliation: Duke University, School of Future Science and Engineering, Soochow University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: Diffusion-based deep-learning frameworks have been recently used in MRI resolution enhancement, or super-resolution. Multi-contrast MRI share common anatomical structures while holding comple...

Demystifying Magnetic Resonance Imaging: Targeted Educational Initiatives for Medical Physicists in Türkiye and Preclinical Medical Students in the United States

Authors: Samuel A. Einstein, Jesutofunmi Fajemisin, Evren O. Göksel, Görkem O. Güngör, Marthony Robins, Travis C. Salzillo, Charles R. Thomas, Turgay Toksay, Joseph Weygand, Yue Yan

Affiliation: Acibadem MAA University, Department of Radiation Oncology and Applied Science, Dartmouth Health, Dartmouth College, Moffitt Cancer Center, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Penn State College of Medicine, Bursa Ali Osman Sönmez Oncology Hospital

Abstract Preview: Purpose: Magnetic resonance imaging (MRI) is an indispensable clinical tool, offering unparalleled soft tissue contrast critical for diagnosing and managing a wide range of conditions. However, its co...

Efficient Robustness Optimization in Intensity Modulated Proton Therapy for Head and Neck Cancer Via Visual State Space Attention Generative Adversarial Networks (VSSA-GAN)

Authors: Nan Li, Yaoying Liu, Shouping Xu, Gaolong Zhang

Affiliation: Department of Radiation Oncology, School of Physics, Beihang University, School of physics, Beihang University, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: In intensity-modulated proton therapy (IMPT) for head and neck cancer, CBCT registration ensures accurate setup, minimizing dose errors. Unlike IMRT, IMPT plans directly define tumor volumes ...

Evaluating Tumor Shrinkage Using Fractionated Radiotherapy: A Mixed Finite Element Method (FEM) for Free Boundary Problem

Authors: Xianjin Dai, PhD, Xiang Wan, Lei Xing, Qiuyun Xu, Lewei Zhao, Zeyu Zhou

Affiliation: Department of Radiation Oncology, Stanford University, Carl Zeiss X-ray Microscopy, Department of Mathematics and Statistics, Loyola University Chicago, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: The purpose of this study is to examine and quantify tumor shrinkage over time in response to fractionated radiotherapy. We seek to establish a predictive model that can provide a systematic ...

Evaluation of Synaptive MRI Geometric Distortion with Sun Nuclear MR Distortion and Image Fusion Head Phantom

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Jing Feng, Wenzheng Feng, Joseph Hanley, Jeff Stainsby, Tingyu Wang

Affiliation: Synaptive Medical, Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose:
The Synaptive MRI is a 0.5T superconducting head only system (first US install 2023). This is the first study that evaluates the geometric accuracy using a Sun Nuclear MR Distortion and Im...

Growing As Leaders Together – Results from the Medical Physics Leadership Academy Fundamentals of Leadership Cohort Program

Authors: Ashley Cetnar, Emily Y. Hirata, Cassandra Stambaugh

Affiliation: University of California San Francisco, Tufts Medical Center, The Ohio State University - James Cancer Hospital

Abstract Preview: Purpose: To provide results from the first four years of the Medical Physics Leadership Academy (MPLA) Fundamental of Leadership Cohort program
Methods: The MPLA Cohorts program began with the Fund...

High Resolution Head Motion Correction Based on Pilot Tone Signals – a Calibration-Free Method

Authors: Cheng-Chieh Cheng, Jeffrey P Guenette, Yajun Li, Bruno Madore, Lei Qin

Affiliation: Brigham and Women's Hospital, National Sun Yat-sen University, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Pilot tone (PT), a compact RF sensor, has been integrated into clinical practice for motion detection. Prior studies proposed mapping PT signals to head positions using a calibration step tha...

Improving Post-SRS Brain Metastasis Radionecrosis Diagnosis Accuracy Via Deep Feature Space Analysis

Authors: Evan Calabrese, Scott R. Floyd, Kyle J. Lafata, Zachary J. Reitman, Eugene Vaios, Chunhao Wang, Lana Wang, Deshan Yang, Zhenyu Yang, Jingtong Zhao

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Duke Kunshan University

Abstract Preview: Purpose:
This study proposes a novel neural ordinary differential equation (NODE) framework to distinguish post-SRS radionecrosis from recurrence in brain metastases (BMs). By integrating imaging f...

Medical Physics in the Oncoverse

Authors: Chandrasekhar Kota

Affiliation: Christiana Care Hospital

Abstract Preview: Purpose: To reflect on the present and future role of Medical Physics in the Oncoverse.
Methods: Oncoverse is the rapidly evolving and expanding ecosystem of all things related to cancer. The Medic...

Neural Implicit K-Space for Accelerated Patient-Specific Non-Cartesian MRI Reconstruction

Authors: Daniel O Connor, Mary Feng, Hui Lin, Hengjie Liu, Xin Miao, Michael Ohliger, Jess E. Scholey, Ke Sheng, DI Xu, Wensha Yang, Yang Yang

Affiliation: UCSF, University of California, Los Angeles, Department of Radiation Oncology, University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco, Department of Radiation Oncology, University of California at San Francisco, University of San Francisco, Department of Radiology, University of California, San Francisco, University of California San Francisco, Siemens Medical Solutions USA Inc.

Abstract Preview: Purpose: The scanning time for a fully sampled MRI is lengthy. Compressed sensing (CS) has been developed to minimize image artifacts in accelerated scans, but the required iterative reconstruction is...

Patient-Specific Deep Reinforcement Learning Framework for Automatic Replanning in Proton Therapy for Head-and-Neck Cancer

Authors: Malvern Madondo, Mark McDonald, Zhen Tian, Christopher Valdes, Ralph Weichselbaum, Xiaofeng Yang, David Yu, Jun Zhou

Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Chicago, Emory University, Department of Radiology, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Head-and-neck (HN) cancer patients often experience significant anatomical changes during treatment course. Proton therapy, particularly intensity-modulated proton therapy (IMPT), is sensitiv...

Predicting Pathological Complete Response to Neoadjuvant Chemotherapy for Breast Cancer at Early Time Points Using a Two-Stage Dual-Task Deep Learning Strategy

Authors: Bowen Jing, Jing Wang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Medical images acquired at multiple time points during neoadjuvant chemotherapy allow physicians to assess patients’ responses and personalize treatment plans accordingly. Studies from the I-...

Research on Multi-Organ Segmentation Based on Cross-Domain Transfer Learning

Authors: Jiali Gong, Yi Guo, Chi Han, Wanli Huo, Hongdong Liu, Zhao Peng, Yaping Qi, Zhaojuan Zhang

Affiliation: Department of Radiotherapy, cancer center, The First Affiliated Hospital of Fujian Medical University, Department of Oncology, Xiangya Hospital, Central South University, State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, China Jiliang University, Division of lonizing Radiation Metrology, National Institute of Metrology, Key Laboratory of Electromagnetic Wave Information Technology and Metrology of Zhejiang Province, College of Information Engineering, China Jiliang University, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University

Abstract Preview: Purpose: To address overfitting from limited training data in multi-organ segmentation, an efficient transfer learning framework is proposed. It reduces reliance on training samples, enabling a single...

Text-Conditioned Latent Diffusion Model for Synthesis of Contrast-Enhanced CT from Non-Contrast CT

Authors: Yizheng Chen, Michael Gensheimer, Mingjie Li, Lei Xing

Affiliation: Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose: Automatically translating non-contrast to contrast-enhanced computed tomography (CT) images is critical for improving clinical workflow, reducing heathcare cost, minimizing radiation exposure...

Use of Radiopaque Rectal Spacer for IGRT – a Preliminary Analysis of Alignment Accuracy and Interobserver Variability

Authors: Joseph A. Miccio, Nicholas J. Potter, Zain Siddiqui

Affiliation: Penn State Health Milton S. Hershey Medical Center

Abstract Preview: Purpose: Fiducial markers are the gold standard for prostate alignment during CT-based image-guided radiotherapy (IGRT). Radiopaque hydrogel rectal spacers reduce rectal toxicity by displacing the rec...