Search Submissions 🔎

Results for "stereotactic head": 34 found

4π Non-Coplanar Stereotactic Body Radiation Therapy: Dosimetric Evaluation of VMAT Configurations in for Recurrent Head and Neck Tumors

Authors: Sixue Dong, Weigang Hu, Jiazhou Wang, Zhen Zhang

Affiliation: Fudan University Shanghai Cancer Center

Abstract Preview: Purpose: This study aimed to evaluate the dosimetric benefits and treatment efficiency of different beam configurations in 4π non-coplanar VMAT for SBRT in recurrent head and neck tumors

Method...

A Ground Truth Label-Mediated Method for Improved Bone and Gas Cavity Definition for MRI-Guided Online Adaptive Radiotherapy Workflows Using Synthetic CT Images.

Authors: Benito De Celis Alonso, Braian Adair Maldonado Luna, Gerardo Uriel Perez Rojas, René Eduardo Rodríguez-Pérez, Kamal Singhrao

Affiliation: Department of Radiation Oncology, Brigham and Women's Hospital, Dana Farber Cancer Institute, Harvard Medical School, Faculty of Physics and Mathematics, Benemérita Universidad Autónoma de Puebla

Abstract Preview: Purpose: Artificial Intelligence (AI)-generated synthetic CT (sCT) images can be used to provide electron densities for dose calculation for online adaptive MRI-guided stereotactic body radiotherapy (...

A Motion Analysis of Cardiac Substructures for Guiding Stereotactic Arrhythmia Radiotherapy Motion Management

Authors: Hongyu An, Phillip Cuculich, H Michael Gach, Yao Hao, Trevor McKeown, Clifford Robinson, Yuhao Wang, Deshan Yang

Affiliation: Washington University School of Medicine in St. Louis, Washington University School of Medicine, Duke University, Department of Radiation Oncology, Duke University, Washington University in St. Louis, Department of Radiation Oncology, Washington University School of Medicine in St. Louis

Abstract Preview: Purpose: This study investigated cardiac motion characteristics of ventricular tachycardia patients to support patient-specific motion management for stereotactic arrhythmia radiotherapy (STAR) treatm...

A Patient-Specific Approach to Surface Guided-DIBH SBRT Candidacy Using Surface Deformation Maps

Authors: Savannah Decker, Grace Gwe-Ya Kim, Laura Padilla

Affiliation: UC San Diego, University of California San Diego

Abstract Preview: Purpose: The success of surface-guided deep-inspiration breath-hold (SG-DIBH) treatments depends on accurate identification of suitable candidates. Sub-optimal patient selection can result in prolonge...

A Quantitative Analysis of Interplay Effects in IMPT for Lung Cancer SBRT: Comparing Two Machine Delivery Sequence Models

Authors: Xiaoda Cong, Xuanfeng Ding, Gang Liu, Peilin Liu, Lewei Zhao

Affiliation: Department of Radiation Oncology, Stanford University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Corewellhealth William Beaumont University Hospital

Abstract Preview: Purpose: This study quantitatively evaluates the interplay effect in intensity-modulated proton therapy (IMPT) for lung cancer stereotactic body radiotherapy (SBRT) using two different machine deliver...

Adapting Newer Treatment Planning Strategy for Uveal Melanoma Cases Using Gamma Knife Radiosurgery

Authors: Deepak Agrawal, Subhash Gupta, Shashanksharad Kale, Gopishankar Natanasabapathi, Manoj Phalak, Dhanabalan Rajasekaran, Surendra Kumar Saini, Subramani Vellaiyan

Affiliation: All India Institute of Medical Sciences (AIIMS), All India Institute of Medical Sciences

Abstract Preview: Purpose:
To evaluate planning strategy for uveal melanoma tumor (UM) in gamma knife stereotactic radiosurgery (GKSRS) using Lightning inverse planning software for treatment planning.
Methods:

Assessing the Need for Online Adaptive Prostate SBRT Using the MR-Linac

Authors: Awens Alphonse, Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Samuel Richter, Lauren A. Rigsby, Tino Romaguera, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: This study evaluates the necessity and potential benefits of online adaptive stereotactic body radiotherapy (SBRT) for prostate cancer using the ViewRay MR-Linac system. By leveraging real-ti...

Automated Treatment Planning for Stereotactic Recurrent Head and Neck Cancers Using Knowledge-Based Planning, Multicriteria Optimization, and Dosimetric Scorecards

Authors: Shane McCarthy, Damodar Pokhrel, William St. Clair, Eddy S Yang

Affiliation: University of Kentucky, Department of Radiation Medicine

Abstract Preview: Purpose: Demonstration of automated stereotactic treatment planning for recurrent head and neck (RHN) cancers using knowledge-based planning, multicriteria optimization (MCO), and dosimetric scorecard...

Clinical Outcomes of Gamma Knife Stereotactic Radiosurgery Treatments for Intracranial Arteriovenous Malformations & Fistulas: A Single Institutional Retrospective Study

Authors: Madeleine Arbogast, David Dorndos, Denise E Foltz, Justin Fraser, Damodar Pokhrel, William St Clair

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Neurosurgery, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: For stereotactic radiosurgery (SRS) treatments of intracranial arteriovenous malformations (AVM) and fistulas (AVF), same-day Leksell Gamma Knife (GK) is the preferred modality. Long-term cli...

Consecutive Daily Fractions with Itv Boost Are Safe for Treating Central Non-Small Cell Lung Cancer Using Stereotactic Body Radiation.

Authors: Baher Elgohari, M. Saiful Huq, Ronald John Lalonde, Fang Li, Noor Mail, Jeonghoon Park, Tyler Wilhite

Affiliation: UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, UPMC Hillman Cancer Center, UPMC, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
To compare toxicity between consecutive-daily (QD) with every-other-day (QoD) delivery of lung stereotactic-body-radiation (SBRT) for central non-small-cell lung cancer (NSCLC).
Methods...

Determining the Effect of Motion during Gamma Knife Stereotactic Radiosurgery on Anterior and Posterior Lesions Using an Anthropomorphic Phantom

Authors: Guang-Pei Chen, Nitish Chopra, Juan A. Garcia-Alvarez, Mi Huang, Slade J. Klawikowski, Haidy G. Nasief, George A. Noid, Abdul Parchur, Eric S. Paulson, Christina M. Sarosiek, Christopher Schultz

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: During routine delivery of mask-based Gamma Knife (GK) SRS, motion is tracked via the position of a reflective sticker placed on the patient’s nose relative to two stationary reflectors on th...

Direct-to-Unit Dose Calculations for Stereotactic Radiosurgery on a C-Arm Linac with Modern on-Board Imaging Solutions

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Haley K Perlow, Alex T. Price, Atefeh Rezaei, Prashant Vempati, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: The HyperSight imaging feature on C-arm linacs(HS-CBCT) offers increased CT number accuracy over conventional on-board imaging. The C-arm geometry allows for noncoplanar treatments common to ...

Dosimetric Impact of Calculation Grid Size in ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang

Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZAP-X is the newest cranial stereotactic radiosurgery (SRS) platform. Small-volume structures usually found in the head and neck may be susceptible to dose-volume averaging, which has not bee...

Dosimetry of Gamma Knife Stereotactic Radiosurgery Tissue Heterogeneity Corrections for Pituitary Adenomas

Authors: James M. Brindle, Gene A. Cardarelli, Alexis Leuci, Mark J. Rivard

Affiliation: Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: Leskell GammaPlan (LGP) is equipped with the Collapsed Cone Convolution (CCC) and TMR10 calculation algorithms. Use of the CCC algorithm accounts for tissue heterogeneities not considered in ...

Early Evaluation Study for Stereotactic Adaptive Radiotherapy for Pancreatic Cancer with Ethos 2.0 System

Authors: Kenneth W. Gregg, Beatriz Guevara, Lauren E Henke, Rojano Kashani, Kyle O'Carroll, Gisele Castro Pereira, Christian Erik Petersen, Alex T. Price, Meiying Xing, Reine abou Zeidane

Affiliation: university hospital, University Hospitals Seidman Cancer Center

Abstract Preview: Purpose:
Experimental data have shown the inconsistent monitor unit and target coverage in Ethos 1.1. This can lead to inaccurate dose delivery, compromising patient safety and treatment outcomes. ...

Enhanced Prediction of Iroc Stereotactic Radiosurgery Phantom Audit Results with Treatment Parameters, Complexity Metrics, DVH, and Dosiomics Using Machine Learning

Authors: Lian Duan, Stephen F. Kry, Hunter S. Mehrens, Christine Peterson, Paige A. Taylor

Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To develop predictive models for IROC SRS head phantom audits and to identify important factors influencing institutional performance.
Methods: The IROC SRS head phantom includes two TLDs ...

Establishing Comprehensive QA for Single-Isocenter Multiple Targets Stereotactic Radiosurgery

Authors: Angel Gomez, Titania Juang, Grace Gwe-Ya Kim, Boyu Meng

Affiliation: UC San Diego, UCSD, University of California San Diego

Abstract Preview: Purpose: Single-Isocenter Multiple Targets (SIMT) Stereotactic Radiosurgery (SRS) is widely used for its precision and effectiveness. However, standardized quality assurance (QA) protocols for SIMT SR...

Evaluating PET-Based Metrics to Identify Patients with Liver Metastases for Biology-Guided Radiotherapy

Authors: Girish Bal, Ke Colin Huang, Christopher F. Njeh, Oluwaseyi Oderinde, Yong Yue

Affiliation: Purdue University, RefleXion Medical, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) uses real-time positron emission tomography (PET) signals to precisely direct radiotherapy beamlets. The success of BgRT planning and delivery relies on PET...

Evaluating the Adequacy of Planning Target Volume Margins in Lung Stereotactic Body Radiation Therapy: Assessment of Intrafraction Motion Using a Fiducial Marker

Authors: Rashmi Benda, Qinghao Chen, Shifeng Chen, Giovanni Lasio, Peter Olivieri, Huijun Xu, Junliang Xu, Byong Yong Yi, Baoshe Zhang, Jinghao Zhou

Affiliation: University of Maryland Baltimore Washington Medical Group, Department of Radiation Oncology, University of Maryland School of Medicine, Capital Region Medical Center, University of Maryland Shore Regional Cancer Center

Abstract Preview: Purpose:
We investigated if the patients receiving lung stereotactic body radiation therapy (SBRT) have adequate planning target volume (PTV) margins by evaluating the intrafraction motion using a ...

Evaluation of Synaptive MRI Geometric Distortion with Sun Nuclear MR Distortion and Image Fusion Head Phantom

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Jing Feng, Wenzheng Feng, Joseph Hanley, Jeff Stainsby, Tingyu Wang

Affiliation: Synaptive Medical, Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose:
The Synaptive MRI is a 0.5T superconducting head only system (first US install 2023). This is the first study that evaluates the geometric accuracy using a Sun Nuclear MR Distortion and Im...

Frameless and Maskless Stereotactic Radiosurgery: Evaluating a Novel Robotic Head Motion Compensation Device

Authors: Michelle Alonso-Basanta, Carl Denis, Wenbo Gu, Xinmin Liu, Ahmad Sakaamini, Rodney D. Wiersma

Affiliation: UCLA, University of Pennsylvania, CDR Systems

Abstract Preview: Purpose: Stereotactic radiosurgery (SRS) is a non-invasive technique used to treat functional abnormalities and small brain tumors. Traditional SRS relies on a rigidly fixed metal head ring, causing d...

Isocenter Optimization for Linear Accelerator-Based Radiosurgical Treatment Planning for Multiple Brain Metastases

Authors: J. Daniel Bourland, Christina K Cramer, Justin M. Napolitano, James D. Ververs

Affiliation: Wake Forest University School of Medicine

Abstract Preview: Purpose:
Brain metastases (BM) can be treated with linear accelerator (LINAC)-based stereotactic radiosurgery (SRS). Treatment planning for this modality has evolved over time; treatment plans typi...

Key Tumor Volume Zones for Advancing the Radiomics-Based Distant Recurrence Prediction

Authors: Ryan Alden, Tithi Biswas, Kaushik Halder, Felix Maria-Joseph, Michael Mix, Rihan Podder, Tarun Kanti Podder

Affiliation: SUNY Upstate Medical University, IIT-Roorkee, University of Florida

Abstract Preview: Purpose: Radiomics feature-based model for predicting distant recurrence can potentially provide critical insight for clinical decision-making and assistance in treatment strategies. This study focuse...

MR-Based Functional Liver Imaging and Dosimetry to Predict Albi Change Post-SBRT

Authors: Madhava Aryal, James M. Balter, Yue Cao, Daniel T Chang, Kyle Cuneo, Joseph R. Evans, Theodore Lawrence, John Rice, Randall K. Ten Haken, Lise Wei

Affiliation: University of Michigan, Department of Radiation Oncology University of Michigan

Abstract Preview: Purpose: This study aims to identify predictors of global liver function change measured by albumin-bilirubin (ALBI) score following stereotactic body radiation therapy (SBRT) in hepatocellular carcin...

Multi-Institutional Analysis of CT Dose Index Variability and Radiomics Features

Authors: Caroline Chung, Michael Knopp, Stephen F. Kry, Hunter S. Mehrens, John Rong

Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, University of Cincinnati

Abstract Preview: Purpose: To evaluate the variability of CT dose index (CTDIvol) and radiomics features across a large cohort of radiotherapy simulation CT scans from multiple institutions.
Methods: Three IROC phan...

Off- Axis Winston Lutz on C-Arm Linac Using in-House Phantom

Authors: Colton Baley, Bhuvaneswari Narayanan, Niko Papanikolaou, Daniel L. Saenz

Affiliation: UT Health San Antonio, Texas Oncology, University of Texas HSC San Antonio

Abstract Preview: Purpose: To evaluate the accuracy of off-axis winston lutz (WLT) for linac based stereotactic radiosurgery (SRS) treatments using in-house phantom.

Methods: Traditional WLT that uses cone and s...

Optimizing Lung SBRT Delivery: Role of Multiple Cbcts in Managing Intra-Fraction Motion

Authors: Anthony J. Doemer, Ian Gallagher, Yimei Huang, Jeff A. Riess, Kundan S Thind, Bo Zhao

Affiliation: Henry Ford Health

Abstract Preview: Purpose: Stereotactic body radiation therapy (SBRT) is commonly used for early-stage lung cancer. While pre-treatment CT captures some tumor motion, it may not fully represent intra-fraction motion du...

Retrospective Evaluation of Combined Photon SBRT and Radium-223 SPECT Based Radiopharmaceutical Therapy Tumor Dosimetry in Clinical Trial Patient Cases

Authors: David P. Adam, Allison Cartee, Eric C. Frey, Michael Ghaly, Bin He, Robert Francois Hobbs, Natalie Rose Kania, Ana Kiess, Ian Marsh, Bonnie N. C. President, Steven Rowe, George Sgouros, Phuoc Tran, Hao Wang

Affiliation: Johns Hopkins University, Radiopharmaceutical Imaging and Dosimetry, LLC (Rapid), 2The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins Medical Institute, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Oncology, Johns Hopkins University, School of Medicine, Department of Radiology, University of North Carolina, Chapel Hill

Abstract Preview: Purpose: Advanced treatment paradigms combining SPECT/CT imageable, alpha emitting, radiopharmaceutical therapy (RPT) and stereotactic body radiotherapy (SBRT) can provide the potential of dose escala...

Robust and Radiobiologically Accurate Dose Summation Strategy for Multiple Courses of Stereotactic Re-Irradiation of Metastatic Brain Cancer Patients with Previous WBRT

Authors: Garrett Russell Hamilton, Joshua Misa, Damodar Pokhrel, William St. Clair

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Recurrent brain metastasis is very common, and patients who previously received whole-brain radiotherapy (WBRT) may receive an additional course(s) of stereotactic radiosurgery (SRS) to selec...

Stereotactic Body Radiosurgery for Refractory Ventricular Tachycardia: Presenting Efficient Clinic Workflow, Dosimetric Analysis and Patients Reported Clinical Results

Authors: Karam Ayoub, Aaron B Hesselson, Ronald C McGarry, Joshua Misa, Damodar Pokhrel

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Cardiology

Abstract Preview: Purpose: Noninvasive stereotactic body radiosurgery (SBRS) is emerging treatment option for advanced heart failure patients with refractory-ventricular tachycardia (rVT) who experienced recurrent impl...

Target Region-Specific Dose-Volume Parameters for Estimate of Brain Toxicity in Single-Isocenter Multiple-Metastases Linac-Based Stereotactic Radiosurgery

Authors: David L. Barbee, Jose R. Teruel Antolin, Jinyu Xue

Affiliation: NYU Langone Health

Abstract Preview: Purpose: This work introduces a method of regional dose evaluation of normal brain tissue using local target-specific evaluation and compares to global dose evaluation for linac-based single-isocenter...

The Impact of Intempo Imaging on Cyberknife Prostate Plans

Authors: Lei Fu, Eric Gressen, Yingcui Jia, Shari Rudoler, Yevgeniy Vinogradskiy, Qianyi Xu

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: InTempo imaging in the Accuray CyberKnife System improves the ability to track/correct target motion during treatment. However, no studies have provided information on the impact of InTempo I...

Tumor Dose Escalation for Recurrent Head and Neck SRT Via a Hyperarc-Based Rapidplan Model

Authors: Shane McCarthy, Damodar Pokhrel, William St. Clair, Eddy S Yang

Affiliation: University of Kentucky, Department of Radiation Medicine

Abstract Preview: Purpose: Demonstrating the feasibility of dose escalation for stereotactic recurrent head and neck (RHN) cancers through the deployment of a Hyper-Arc Based RapidPlan (HARP) model through an Eclipse S...

Validation of SRS Mapcheck for Patient-Specific Quality Assurance of Cyberknife

Authors: Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, Tae Ho Kim, Sangmin Lee

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: The CyberKnife system, designed for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT), considers SRS MapCHECK an effective tool for patient-specific QA (PSQA). This wo...