Search Submissions 🔎

Results for "stopping power": 23 found

Absolute Measurement of HDR Ir-192 Air-Kerma Strength Using an Exradin A3 Known-Volume Ionization Chamber

Authors: Larry A. DeWerd, Sean Jollota, Karen Rex Pius Vincent

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Absolute measurements, often used to establish primary standards, offer lower measurement uncertainty. For 192Ir high-dose-rate (HDR) brachytherapy, the interim primary standard for air-kerma...

An Initial Simulation Study Towards the Patient-Specific Estimation of Stopping Power Ratio and Sound Velocity Using Protoacoustics: A Sensitivity Matrix Method

Authors: Ye Chen, Koki Kasamatsu, Taeko Matsuura, Taichi Murakami

Affiliation: Hokkaido University, National Institutes for Quantum Science and Technology (QST)

Abstract Preview: Purpose: In proton therapy, CT-based estimation of the stopping power ratio (SPR) is a significant source of range uncertainty. Protoacoustics have been developed to estimate the range in vivo, but fe...

Can Contrast Scans of Dual-Layer Detector Spectral CT be Directly Used for Proton Dose Calculations?

Authors: Wen C. Hsi, Pouya Sabouri, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
Traditional single-energy CT (SECT) contrast scans cannot be used for proton dose calculations due to significantly higher HU caused by iodine. Dual-layer dual-energy CT (DL-DECT) can dire...

Characterizing the Stability of Upright CT for Proton Therapy

Authors: Brian Burger, Carri K. Glide-Hurst, John W. Hayes, Carson Hoffman, Minglei Kang, Jessica R. Miller, Jordan M. Slagowski, Yuhao Yan

Affiliation: Department of Human Oncology, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Leo Cancer Care

Abstract Preview: Purpose: The combination of upright CT and patient positioner for particle therapy present tremendous potential for high precision IGRT and online adaptive radiation therapy (ART), where reliable CT p...

Comparing the Rsp Accuracy of a Fast Switching Dual-Energy CT to Single-Energy CT Using Proton CT in Animal Tissue.

Authors: Paul Deak, Yang Li, Mark Pankuch, Yanling Qu, Maggie Stauffer, Hazel Wang

Affiliation: Northwestern Medicine Proton Center, GE, Northwestern Medicine

Abstract Preview: Purpose: The objective is to evaluate Relative Stopping Power(RSP) accuracy of ultra-fast switching KV Dual-Energy CT(DECT) in animal tissue and compare it to the RSP converted from Single Energy CT(S...

Data-Driven Forward Projector for Optimization of the Proton Stopping Power Calibration in Treatment Planning Based on Sparse Proton Radiographies

Authors: Hector Andrade-Loarca, Ines Butz, Chiara Gianoli, Prof. Gitta Kutyniok, Jianfei Li, Katia Parodi, Prof. Vincenzo Patera, Angelo Schiavi, Prof. Ozan Öktem

Affiliation: Sapienza University of Rome, Department of Mathematics, Royal Institute of Technology, School of Computation, Information and Technology, Technische Universitaet Muenchen, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Department of Mathematics, Ludwig-Maximilians-Universität (LMU) München, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München

Abstract Preview: Purpose: To explore and demonstrate the feasibility of accurate and fast prediction of the water equivalent thickness (WET) distribution of tissue traversed by a proton imaging pencil beam, aiming at ...

Determination of HU Override for Small Metal Implants in Proton Therapy

Authors: Matthew Stephen Andriotty, Taoran Cui, Harold Y Hu, Ke Nie, Tan Phan, Xiao Wang, Ning J. Yue, Chengzhu Zhang

Affiliation: Rutgers Cancer Institute of New Jersey, Basis Scottsdale

Abstract Preview: Purpose: Metallic implants are often non-isocentric, and their exact volumes/orientations/shapes are difficult to capture and contour accurately on CT images even if that information is known beforeha...

Development of a Proton CT System Based on 2D Scintillation Detection

Authors: Haonian Gong, Yue Gu, Meiqi Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang

Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China

Abstract Preview: Purpose: To develop a proton CT system using scintillator-based 2D dose distribution detection for accurate proton imaging.
Methods: The proposed proton CT system consists of a brass collimator wit...

Development of a Visualization Tool for LET and Proton Spot Mapping for PB Treatment Planning

Authors: Chang Chang, Mohammad Kanber, Stephen Kenneth Northway

Affiliation: East Carolina University, California Protons Cancer Therapy Center, California Proton Cancer Therapy Center

Abstract Preview: Purpose:
Proton therapy treatment planning involves the consideration of unique physical quantities such as Linear Energy Transfer (LET) and spot location maps that do not exist in photon treatment...

Dosimetric Comparison & Error Analysis of Aapm TG51 & WGTG51-e Protocol with Icru-90 Key-Data for High-Energy Clinical Electron Beam

Authors: Amar K. Basavatia, Sandeepan Ganguly, Lee C. Goddard, Wolfgang A. Tomé

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: To investigate the dosimetric impact of WGTG51-e Report 385, recently updated CoP for clinical electron beams. This study uses a chamber specific effective point of measurement (EPOM) shift t...

Energy Dependency of Biological Effects from Radiation Scattering Around Medical Implants in Particle Therapy

Authors: John Ford, Yu Fujiwara, Isao Murata, Zavier Ndum Ndum

Affiliation: Osaka University, Texas A&M University

Abstract Preview: Purpose: This study investigates how particle energy affects radiation quality and biological effectiveness with the inclusion of medical implants. Our research group used microdosimetric analysis to ...

Feasibility of Commercial Independent-Dose-Calculation for Pencil-Beam-Scanning Proton Therapy

Authors: Wen C. Hsi, Kayla Schneider

Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences

Abstract Preview: Purpose:
Measurement-based patient-specific quality-assurance (PSQA) conducted with a 2D dosimeter to verify delivered dose of each field over 3 measurement-depths is time-consuming with limited se...

Feasibility of a Normoxic N-Vinylpyrrolidone-Based Polymer Gel (VIPET) Dosimeter for Three-Dimensional Proton Beam Measurements

Authors: Yoshihiko Hoshino, Kenji Hotta, Taeko Matsuura, Ai Nakaoka, Hidenobu Tachibana

Affiliation: Hokkaido University, Department of Radiology, Gunma University Hospital, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East

Abstract Preview: Purpose: Gel dosimeters enable three-dimensional dose measurements, but no reports have evaluated the fundamental performance of VIPER-type gel dosimeters in proton beam measurements. Therefore, we ev...

First in-Vivo Application of a Novel Precision Small Animal Irradiation Platform with Proton IMPT Delivery and Advanced on-Board Image-Guidance

Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf

Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital

Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...

First in-Vivo Proton Radiography Experiments for an Image-Guided Small Animal Irradiation Platform with a TimePix3-Based Detector Setup

Authors: Niels Bassler, Jonathan Bortfeldt, Carlos Granja, Guyue Hu, Margarita Kozak, Julie Lascaud, Kirsten Lauber, Grigory Liubchenko, Jasper Nijkamp, Cristina Oancea, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Brita Singers Sørensen, Matthias Würl

Affiliation: Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital, Advacam

Abstract Preview: Purpose: To apply in-vivo proton radiography (pRad) to aid image registration and treatment plan refinement for a novel precision image-guided small animal proton irradiation platform.

Methods:...

Generation of Patient-Specific Phantom for Head & Neck Proton Therapy Based on Xcat

Authors: Cheng-En Hsieh, Shen-Hao Li, Hsin-Hon Lin, Shu-Wei Wu, An-Ci Yang

Affiliation: Department of Medical Imaging and Radiological Sciences, Chang Gung University, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital Linkou

Abstract Preview: Purpose:
The aim of this study is to develop a framework of generating patient-specific phantom tailored for head and neck proton therapy. From these phantoms, digital reference objects based on th...

On Dosimetric Water Equivalency of 3D Printed Materials

Authors: Emily Helen Hayes, Luke Maloney

Affiliation: University of Florida

Abstract Preview: Purpose: To determine the dosimetric water equivalency of polylactic acid (PLA) and commercial 3D printing resin using electron stopping power as a surrogate, for use in radiochromic film calibration ...

Photon-Counting CT for Estimation of Quantitative Information for Radiation Therapy Treatment Planning: Assessment of Scanning Conditions and Phantom Sizes

Authors: Carina Gassner, Guyue Hu, Thomas Kröncke, Christopher Kurz, Guillaume Landry, Katharina Niepel, Katia Parodi, Franka Risch, Florian Schwarz

Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)

Abstract Preview: Purpose: To evaluate the performance of a clinical photon-counting CT (PCCT) scanner in terms of proton relative stopping power (RSP) estimation using PCCT data and to compare the impact of different ...

Predicting Proton Therapy Dose Delivery Accuracy: A Machine Learning Approach Using Iroc’s Proton Phantom Data

Authors: Lian Duan, Stephen F. Kry, Hunter S. Mehrens, Paige A. Taylor

Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To develop a machine learning model for predicting dose delivery accuracy and identifying its key factors in IROC’s proton phantom program.
Methods: IROC’s proton QA program has six proton...

The CT Calibration for Proton Pencil Beams System

Authors: Xiangli Cui, Wanli Huo, Jie Li, Lingling Liu, Tao Ma, Yuanyuan Wang

Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Ion Medical Center, Hefei Cancer Hospital, Chinese Academy of Sciences, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University

Abstract Preview: Purpose: In practice, treatment planning systems (TPS) of proton therapy require a CT calibration curve, which relates Hounsfield units (HU) to relative stopping power (RSP). Single-energy CT as a sta...

The Fermi Density Effect: Review and Discussion about Applicability on Stopping Powers and Cross Sections

Authors: Michael Dingfelder

Affiliation: East Carolina University

Abstract Preview: Purpose:
To study and accurately evaluate the influence of the Fermi Density effect on stopping powers and cross sections of charged particles in liquid water used in Monte Carlo radiation transpor...

Universal Range Modulators for Flash Proton Therapy: 3D Printing of Stackable Variable Density Units

Authors: Eric S. Diffenderfer, Lei Dong, Alejandro Garcia, Wenbo Gu, Michele M. Kim, Alexander Lin, Kai Mei, Peter B. Noël, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: We present a novel 3D-printed range-modulating devices with spatially modulated density for FLASH particle therapy. By varying density distributions, spread-out Bragg peaks(SOBPs) can be gene...

Validation of Updated CT-to-SPR Calibration Method with Icrp-145 Data for Carbon-Ion Radiotherapy

Authors: Min Cheol Han, Soorim Han, Chan Hyeong Kim, Jin Sung Kim, Seok-Ho Lee, Gahee Son, Yongdo Yun

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Hanyang University, Department of Integrative Medicine, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: The stoichiometric calibration method proposed by Kanematsu et al. (2016) has been widely adopted for CT number to stopping-power ratio (SPR) conversion in carbon-ion radiotherapy. With the r...