Search Submissions ๐Ÿ”Ž

Results for "sweeping gap": 6 found

Dosimetric Evaluation of Enhanced Dynamic Leaf Gap Modeling in Small-Field Clinical Plans: A Verification Study

Authors: Ian J. Butterwick, Sumudu Katugampola, ChangSeon Kim, Evan G. Meekins, Zhengdong Zhang

Affiliation: Mount Sinai Beth Israel, Gesinger Medical Center, Geisinger Medical Center

Abstract Preview: Purpose: To evaluate the dosimetric impact of enhanced dynamic leaf gap (EDLG) modeling in Eclipse V18.0 on small-field dosimetry within VMAT plans.
Methods: Plans with small fields (1 cm x 1 cm to...

Evaluation of the Improvements of a New Leaf Model (Enhanced Leaf Model) for the Halcyon

Authors: Evan Barber, Gloria P. Beyer, Callum Hartley, Jordi Saez, Philip Wheeler

Affiliation: Department of Radiation Oncology, Hospital Clinic de Barcelona, Department of Radiotherapy Physics, Velindre University NHS Trust, Medical Physics Services, LLC

Abstract Preview: Purpose: To evaluate the Enhanced Leaf Model (ELM) in Eclipse v18 to the standard leaf model for the Halcyon multileaf collimator (MLC) using a measurement-based method.
Methods: The Halcyonโ€™s doub...

Inter-System and Inter-Layer Dlg Variations in Halcyon/Ethos Mlcs: Implications for Dosimetric Matching and User-Adjustable TPS Models

Authors: Evan Barber, Gloria P. Beyer, Matthew J. Daniels, Callum Hartley, Jordi Saez, Philip Wheeler

Affiliation: TrueNorth Medical Physics, Department of Radiotherapy Physics, Velindre University NHS Trust, Department of Radiation Oncology, Hospital Clinic de Barcelona, Medical Physics Services, LLC

Abstract Preview: Purpose: To quantify inter-system and inter-layer dosimetric leaf gap (DLG) variations in Halcyon/Ethos multileaf collimators (MLCs) using custom sweeping gap tests, and to evaluate implications for c...

Investigating the Effect of Beam Flattening Filter on Dose Estimated with Varianโ€™s Original and Enhanced Mlc Models

Authors: Kenny Guida, Hongyu Jiang, Harold Li, Hem Bahadur Moktan Tamang

Affiliation: University of Nebraska Medical Center, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Varian Eclipse v18.0 introduced Enhanced Leaf Model (ELM) of MLC, which provides better dose calculation accuracy than original DLG-based MLC model. The leaf-gap (LG) parameter for ELM repres...

Quantitative Evaluation of Eclipseโ€™s (V18) Ability to Address Dosimetric Leaf Gap Variations

Authors: D. Michael Lovelock, Charlotte Elizabeth Read, Ren-Dih Sheu, Jing Wang, Tingyu Wang

Affiliation: Icahn School of Medicine at Mount Sinai, Jersey Shore University Medical Center

Abstract Preview: Purpose:
Early Eclipse models use rectangular fluence profiles (widened by the dosimetric leaf gap (DLG) to account for the fact that leaf tips are rounded). Eclipse Version 18 (V18) uses enhanced ...

Treatment Machine Matching for ELM in Eclipse v18.0 By Adjusting Physical Leaf Gap

Authors: Quyen Duong, Si Young Jang, Soyoung Lee, Samuel Ming Ho Luk

Affiliation: Boston University, Department of Radiation Oncology, University of Vermont Medical Center, Boston Medical Center

Abstract Preview: Purpose: To investigate the clinical impact of physical MLC gaps changes with Millennium 120 MLC on Enhanced Leaf Modeling (ELM) and patient plans, and to establish a new MLC model in Eclipse v18.0 on...