Authors: Ke Colin Huang, Zirui Jiang, Joshua Low, Christopher F. Njeh, Oluwaseyi Oderinde, Yong Yue
Affiliation: Purdue University, Indiana University School of Medicine, Department of Radiation Oncology
Abstract Preview: Purpose: Enhancing the accuracy of tumor response predictions enables the development of tailored therapeutic strategies for patients with breast cancer (BCa). In this study, we developed deep-radiomi...
Authors: Michael Buckstein, Yang Lei, Tian Liu, Charlotte Elizabeth Read, Jing Wang, Kaida Yang, Jiahan Zhang
Affiliation: Icahn School of Medicine at Mount Sinai
Abstract Preview: Purpose: Inter-fraction anatomic variations in liver SBRT can cause significant discrepancies between planned and delivered doses. We developed a CBCT-based accumulative algorithm to directly compare ...
Authors: Yang Lei, Haibo Lin, Tian Liu, Charles B. Simone, Shouyi Wei, Ajay Zheng
Affiliation: Icahn School of Medicine at Mount Sinai, New York Proton Center
Abstract Preview: Purpose: Radiation-induced lung injury (RILI), encompassing pneumonitis and fibrosis, represents a critical dose-limiting factor in lung cancer radiation therapy. Variability in treatment outcomes is ...
Authors: Caiden Atienza, Pim T. S. Borman, Martin F. Fast, Daniel E. Hyer, Bas W. Raaymakers, Jeffrey E. Snyder, Prescilla Uijtewaal, Peter Woodhead
Affiliation: Department of Radiotherapy, University Medical Center Utrecht, Yale New Haven Health, University of Iowa
Abstract Preview: Purpose:
On conventional C-arm linacs, VMAT is the preferred delivery modality due to its superior efficiency and highly conformal dose distributions. MR-linacs offer superior soft-tissue imaging t...
Authors: Alejandro Bertolet, Jose Antonio Lopez-Valverde, Victor V. Onecha, Daniel Puerta
Affiliation: Dana Farber Cancer Institute/Brigham and Women's Hospital, Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, Massachusetts General Hospital and Harvard Medical School
Abstract Preview: Purpose: Besides its superior dose conformity, proton therapy induces greater damage to tissue than conventional radiotherapies. This increased damage is usually quantified through the concept of rela...
Authors: Resat Aydin, Joseph Barbiere, Brett Lewis, Roland Teboh
Affiliation: HUMC, Hackensack University Medical Center
Abstract Preview: Purpose:
Accurately compensating for respiratory-induced tumor motion is critical in BgRT, where precise delineation of volumes ensures effective dose delivery. We propose an integrated approach th...
Authors: Bowen Jing, Jing Wang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Medical images acquired at multiple time points during neoadjuvant chemotherapy allow physicians to assess patients’ responses and personalize treatment plans accordingly. Studies from the I-...
Authors: Teh Lin, Anna Oneil
Affiliation: Fox Chase Cancer Center
Abstract Preview: Purpose: Four-dimensional computed tomography(4DCT) is often required to assess organ motions for thoracic and abdominal cancer patients. This study proposes a quality assurance (QA) procedure for two...
Authors: Yan Dai, Jie Deng, Xun Jia, Wen Li
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Cell microstructure information is critical for radiotherapy response assessment. Diffusion MRI (dMRI) offers great potential in deriving cell parameters. Yet parameters estimated in existing...
Authors: Tatsuya Fujisaki, Hiraku Fuse, Shin Miyakawa, Hiroki Nosaka, Masato Takahashi, Kenji Yasue
Affiliation: Ibaraki Prefectural University of Health Sciences
Abstract Preview: Purpose: This study aimed to evaluate the robustness of Jacobian-based and HUchange-based CT ventilation imaging (CTVI) against respiratory amplitude variations using a custom-designed alveolar phanto...
Authors: Sean L. Berry, Weixing Cai, Laura I. Cervino, Yusuf Emre Erdi, Yabo Fu, Yiming Gao, Daphna Gelblum, Wendy B. Harris, Xiuxiu He, Tianfang Li, Xiang Li, Seng Boh Gary Lim, Jean M. Moran, Mitchell Yu, Hao Zhang
Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Gated CBCT (gCBCT) is commonly employed for respiratory gating lung cancer patients to ensure precise patient setup. However, the scan is time-consuming on C-arm linear accelerators (LINAC) d...
Authors: Laura I. Cervino, Sharif Elguindi, Yu-Chi Hu, Licheng Kuo, Xiaoning Liu, Jennifer Ma, Pengpeng Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Radiation Oncology, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose:
Quad-shot radiotherapy (QSRT) is an emerging paradigm in palliative cancer treatment. This study aimed to streamline the QSRT workflow using automation to improve efficiency while maintain...
Authors: Laura I. Cervino, Wendy B. Harris, Paulo Quintero, Hao Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: To evaluate the impact of the prediction uncertainty from CBCT-based synthetic CT (sCT) generation in abdominal adaptive radiotherapy.
Methods: CT and CBCT images from 65 abdominal pat...