Search Submissions 🔎

Results for "three cycles": 13 found

18F-FDG PET/CT-Based Deep Radiomic Models for Enhancing Chemotherapy Response Prediction in Breast Cancer

Authors: Ke Colin Huang, Zirui Jiang, Joshua Low, Christopher F. Njeh, Oluwaseyi Oderinde, Yong Yue

Affiliation: Purdue University, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Enhancing the accuracy of tumor response predictions enables the development of tailored therapeutic strategies for patients with breast cancer (BCa). In this study, we developed deep-radiomi...

Direct Dose Verification in Liver SBRT Utilizing an Accumulative Daily CBCT Algorithm

Authors: Michael Buckstein, Yang Lei, Tian Liu, Charlotte Elizabeth Read, Jing Wang, Kaida Yang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose: Inter-fraction anatomic variations in liver SBRT can cause significant discrepancies between planned and delivered doses. We developed a CBCT-based accumulative algorithm to directly compare ...

Enhancing Proton Treatment and Mitigating Radiation-Induced Lung Injury Using a Novel Cycle Diffusion Approach for Lung Ventilation Estimation

Authors: Yang Lei, Haibo Lin, Tian Liu, Charles B. Simone, Shouyi Wei, Ajay Zheng

Affiliation: Icahn School of Medicine at Mount Sinai, New York Proton Center

Abstract Preview: Purpose: Radiation-induced lung injury (RILI), encompassing pneumonitis and fibrosis, represents a critical dose-limiting factor in lung cancer radiation therapy. Variability in treatment outcomes is ...

Exploring the Compatibility of VMAT and Respiratory Beam Gating on MR-Linac: A Proof-of-Concept Study

Authors: Caiden Atienza, Pim T. S. Borman, Martin F. Fast, Daniel E. Hyer, Bas W. Raaymakers, Jeffrey E. Snyder, Prescilla Uijtewaal, Peter Woodhead

Affiliation: Department of Radiotherapy, University Medical Center Utrecht, Yale New Haven Health, University of Iowa

Abstract Preview: Purpose:
On conventional C-arm linacs, VMAT is the preferred delivery modality due to its superior efficiency and highly conformal dose distributions. MR-linacs offer superior soft-tissue imaging t...

Extending Chronorepair: A Computational Model of the Effects of Radiotherapy in Cells

Authors: Alejandro Bertolet, Jose Antonio Lopez-Valverde, Victor V. Onecha, Daniel Puerta

Affiliation: Dana Farber Cancer Institute/Brigham and Women's Hospital, Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: Besides its superior dose conformity, proton therapy induces greater damage to tissue than conventional radiotherapies. This increased damage is usually quantified through the concept of rela...

Finding the Best Match of 4D-CT Phases to Delineate Volumes for Bgrt

Authors: Resat Aydin, Joseph Barbiere, Brett Lewis, Roland Teboh

Affiliation: HUMC, Hackensack University Medical Center

Abstract Preview: Purpose:
Accurately compensating for respiratory-induced tumor motion is critical in BgRT, where precise delineation of volumes ensures effective dose delivery. We propose an integrated approach th...

Predicting Pathological Complete Response to Neoadjuvant Chemotherapy for Breast Cancer at Early Time Points Using a Two-Stage Dual-Task Deep Learning Strategy

Authors: Bowen Jing, Jing Wang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Medical images acquired at multiple time points during neoadjuvant chemotherapy allow physicians to assess patients’ responses and personalize treatment plans accordingly. Studies from the I-...

Quality Assurance of Four-Dimensional Computed Tomography (4DCT)

Authors: Teh Lin, Anna Oneil

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Four-dimensional computed tomography(4DCT) is often required to assess organ motions for thoracic and abdominal cancer patients. This study proposes a quality assurance (QA) procedure for two...

Robust Estimation of Cell Microstructure Parameters Via Diffusion MRI Cytometry

Authors: Yan Dai, Jie Deng, Xun Jia, Wen Li

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Cell microstructure information is critical for radiotherapy response assessment. Diffusion MRI (dMRI) offers great potential in deriving cell parameters. Yet parameters estimated in existing...

Robustness of Jacobian-Based and HU Change-Based CT Ventilation Imaging to Respiratory Amplitude Variations: A Study Using a Custom Phantom with Respiratory Amplitude Control

Authors: Tatsuya Fujisaki, Hiraku Fuse, Shin Miyakawa, Hiroki Nosaka, Masato Takahashi, Kenji Yasue

Affiliation: Ibaraki Prefectural University of Health Sciences

Abstract Preview: Purpose: This study aimed to evaluate the robustness of Jacobian-based and HUchange-based CT ventilation imaging (CTVI) against respiratory amplitude variations using a custom-designed alveolar phanto...

Scan Efficiency and Imaging Dose Analysis of Next-Generation Nonstop Gated CBCT for Respiratory Gating Lung Radiotherapy

Authors: Sean L. Berry, Weixing Cai, Laura I. Cervino, Yusuf Emre Erdi, Yabo Fu, Yiming Gao, Daphna Gelblum, Wendy B. Harris, Xiuxiu He, Tianfang Li, Xiang Li, Seng Boh Gary Lim, Jean M. Moran, Mitchell Yu, Hao Zhang

Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Gated CBCT (gCBCT) is commonly employed for respiratory gating lung cancer patients to ensure precise patient setup. However, the scan is time-consuming on C-arm linear accelerators (LINAC) d...

Streamlining Quad-Shot Radiotherapy: Automated Workflow Enables Same-Day Treatment for Palliative Lung Cancer

Authors: Laura I. Cervino, Sharif Elguindi, Yu-Chi Hu, Licheng Kuo, Xiaoning Liu, Jennifer Ma, Pengpeng Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Radiation Oncology, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
Quad-shot radiotherapy (QSRT) is an emerging paradigm in palliative cancer treatment. This study aimed to streamline the QSRT workflow using automation to improve efficiency while maintain...

Uncertainties on Synthetic-CT Generation from CBCT: Another Layer of Complexity in Abdominal Adaptive Radiotherapy

Authors: Laura I. Cervino, Wendy B. Harris, Paulo Quintero, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To evaluate the impact of the prediction uncertainty from CBCT-based synthetic CT (sCT) generation in abdominal adaptive radiotherapy.

Methods: CT and CBCT images from 65 abdominal pat...