Search Submissions 🔎

Results for "tld end": 8 found

A Novel Cost-Effective Customizable 3D-Printed Thoracic Phantom for End-to-End Treatment Verification and Image Quality Assessment

Authors: Reza Farjam, Russell K Hales, Seth Jayawardane, Todd R. McNutt, Mohammad Rezaee, Ehsan Tajikmansoury, K. Ranh Voong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins School of Medicine

Abstract Preview: Purpose: This study presents a novel cost-effective customizable 3D-printed phantom developed for end-to-end treatment verification and image-quality assessment for thoracic applications.
Methods: ...

An Analytical Approach to Monitor Unit Calculation in Extended Distance Total Body Irradiation (TBI)

Authors: Cheewai Cheng, Indra J. Das, Jeffrey Yui Hei Wong, Poonam Yadav

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine

Abstract Preview: Purpose: Radiation treatment machine replacement brings chaos and urgency of timely completion of machine commissioning for every procedure used including TBI that are time consuming. Based on past ex...

Commissioning and Validation of Monaco Proton Treatment Planning System on a Compact Proton Therapy System

Authors: Shupeng Chen, Xiaoda Cong, Raymond Dalfsen, Rohan Deraniyagala, Xuanfeng Ding, James E. Dolan, Xiaoqiang Li, Jian Liang, Peilin Liu, An Qin, Martin Soukup, Craig Stevens, Xiangkun Xu, Weili Zheng

Affiliation: Corewell Health William Beaumont University Hospital, Corewellhealth William Beaumont University Hospital, William Beaumont University Hospital, Elekta, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Corewellhealth William Beaumont Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital

Abstract Preview: Purpose: To facilitate clinical use of the proton feature of Monaco treatment planning system(TPS), we commissioned and validated it on a compact proton therapy system.
Methods: Pencil Beam Scannin...

Decoupling Cardiorespiratory Motion of Cardiac Substructures Via 5D-MRI for Radiotherapy

Authors: Carri K. Glide-Hurst, Thomas M Grist, Kevin M. Johnson, Prashant Nagpal, Tarun Naren, Chase Ruff, Oliver Wieben, Jiwei Zhao

Affiliation: Department of Biostatistics and Medical Informatics, University of Wisconsin - Madison, Department of Radiology, University of Wisconsin-Madison, Department of Medical Physics, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison

Abstract Preview: Purpose: Cardiotoxicity is a devastating side effect for thoracic radiotherapy (RT). Currently, standard RT imaging is insufficient to decouple cardiorespiratory motion, limiting substructure-specific...

Performance Evaluation of End-of-Life Epid Panel Utilizing Automated Quality Assurance Test Suite

Authors: Michael Paul Barnes, Lana C. Critchfield, John J. DeMarco, Ellie Durussel, Nilendu Gupta, James Irrer, Peyton Jensen, Grace Gwe-Ya Kim, Cory S. Knill, Seng Boh Gary Lim, Justin K. Mikell, Jean M. Moran, Seyyedeh Azar Oliaei Motlagh, Mario Perez, Michael Pillainayagam, Claire Zhang

Affiliation: University of Michigan, Department of Radiation Oncology, University of Michigan, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Washington University School of Medicine in St. Louis, University of California San Diego, Royal North Shore Hospital, Calvary Mater Hospital Newcastle, Cedars-Sinai Medical Center

Abstract Preview: Purpose: EPIDs are widely used in linac QA due to their efficiency and accuracy. As EPIDs age, performance degradation may occur, potentially compromising reliability of EPID-based automated QA result...

The Use of a Milled NIST Traceable Tld for End-to-End Validation in Mlc and Cone SRS Programs.

Authors: Ross Bland, Zachary A. Christ, Sophy Mangana, Feba Mathew, Stephanie K. Phoenix, Joseph Salloum, Jason D. Stanford, William Zollinger

Affiliation: Forrest General Cancer Center, Northeast Louisiana Cancer Institute, Florida Atlantic University

Abstract Preview: Purpose: The objective of this paper is twofold: 1) to explore the efficacy of using referenced beam models supplied by the vendor (Brainlab) and 2) the efficacy of NIST traceable TLD for end-to-end v...

The Z Dimension Matters: 3D Noise Power Spectrum of a Clinical Photon Counting Detector CT System

Authors: Frank F. Dong, Megan C. Jacobsen, Ke Li, Xinming Liu, Humberto Monsivais, John Rong

Affiliation: Purdue University, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To investigate the noise characteristics of a clinical photon counting detector CT (PCD-CT) system along axial and through-plane (Z) dimensions using 3D NPS measurements.
Methods: This stu...

What Do We Do with Our Old Pinnacle Data?

Authors: Caiden Atienza, Daniel E. Hyer, Samuel D. Rusu, Blake R. Smith, Joel J. St-Aubin

Affiliation: Iowa Health Care, University of Iowa

Abstract Preview: Purpose: Pinnacle3 TPS (Philips Radiation Oncology Systems, Fitchburg, WI, USA) support is set to end by December 31, 2026. This work presents a validated method to archive Pinnacle data, which may be...