Search Submissions 🔎

Results for "total body": 47 found

4π Non-Coplanar Stereotactic Body Radiation Therapy: Dosimetric Evaluation of VMAT Configurations in for Recurrent Head and Neck Tumors

Authors: Sixue Dong, Weigang Hu, Jiazhou Wang, Zhen Zhang

Affiliation: Fudan University Shanghai Cancer Center

Abstract Preview: Purpose: This study aimed to evaluate the dosimetric benefits and treatment efficiency of different beam configurations in 4π non-coplanar VMAT for SBRT in recurrent head and neck tumors

Method...

A Comparison of on-Isocenter Vs Off-Isocenter Planning for Lung SBRT on the Viewray Mridian

Authors: Nebi Demez, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Nishan Shrestha

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: Treatment plans on the ViewRay MRIdian are often planned with the target placed off isocenter due to the proximity of the bore to the patient, allowing for limited shifts. This is especially ...

A Dosimetric Investigation into the Potential of Aperture-Based Techniques to Improve the Clinical Outcomes of Single-Energy Proton Bragg Peak Flash Therapy for Ocular Cancers

Authors: Arpit M. Chhabra, J Isabelle Choi, Minglei Kang, Haibo Lin, Hang Qi, Charles B. Simone, Shouyi Wei, Irini Yacoub, Francis Yu, Xingyi Zhao, Ajay Zheng

Affiliation: New York Proton Center, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose:
Pencil beam scanning (PBS) proton therapy effectively treats ocular cancer by minimizing exit doses to normal tissues. However, challenges remain in sparing nearby organs-at-risk(OARs). Ul...

A Multi-Omics Approach for Predicting Acute Hematologic Toxicity in Patients with Cervical Cancer Undergoing External-Beam Radiotherapy

Authors: Sijuan Huang, Yongbao Li

Affiliation: Sun Yat-sen University Cancer Center; State Key Laboratory of Oncology in South China; Collaborative Innovation Center for Cancer Medicine; Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangzhou, Guangdong, 510060, China, Sun-Yat sen University Cancer Center

Abstract Preview: Purpose: Hematologic toxicity (HT) is one of the most prevalent treatment-related toxicities experienced by locally advanced cervical cancer (LACC) patients receiving radiotherapy (RT). This study aim...

AI-Assisted Algorithm to Generate Patient Postures for Tset Dose Evaluation

Authors: Kostas Danniidis, Agelos Kratimenos, Yufu Wang, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: This study aims to develop software and algorithms utilizing artificial intelligence (AI) to seamlessly create 3D patient postures during Total Skin Electron Therapy (TSET). The resulting mes...

Accuracy Analysis of "Sphere-Mask" Optical Positioning System in Radiotherapy of Breast Cancer

Authors: Xiu tong Lin, Tao Sun

Affiliation: Department of Radiation physics and technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation physics and technology, Shandong Second Provincial General Hospital

Abstract Preview: Purpose: To compare the positioning accuracy and time efficiency of "Sphere-Mask" Optical Positioning System (OPS) and traditional laser light positioning method in breast cancer radiotherapy, and to ...

An Analytical Approach to Monitor Unit Calculation in Extended Distance Total Body Irradiation (TBI)

Authors: Cheewai Cheng, Indra J. Das, Jeffrey Yui Hei Wong, Poonam Yadav

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine

Abstract Preview: Purpose: Radiation treatment machine replacement brings chaos and urgency of timely completion of machine commissioning for every procedure used including TBI that are time consuming. Based on past ex...

Clinical Factors Associated with Urinary Morbidity in Men Undergoing Combination Prostate Radiation Therapy

Authors: James Benton, Andrew Dewar, Benjamin C Lee, Ryan Y Lee

Affiliation: Radiotherapy Clinics of Georgia, Urology of Greater Atlanta

Abstract Preview: Purpose:
The purpose of our investigation was to determine if pre-treatment factors could predict urinary morbidity after combination radiation treatment for localized prostate cancer.
Methods:<...

Clinical Implementation of Volumetric Modulated Arc Therapy (VMAT) for Total Body Irradiation (TBI) with Off-the-Shelf Tools

Authors: Kai-Cheng Chuang, Oana I. Craciunescu, Christopher Kelsey, Joseph Kowalski, Nicole Larrier, Xinyi Li, Sheridan G. Meltsner, Anna E. Rodrigues, Yang Sheng, Qiuwen Wu

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: To clinically implement a Volumetric Modulated Arc Therapy (VMAT) procedure for Total Body Irradiation (TBI) with off-the-shelf tools.
Methods: Patient is treated on linac couch with a hyb...

Commissioning a Comprehensive Workflow for VMAT Total Body Irradiation (TBI) Using Publicly and Commercially Available Resources

Authors: Alan H. Baydush, Sarah Cummings, Jeffrey Michael Fenoli, Christy Hickerson, Lalith Kumaraswamy, Philmo Oh, Sarah B. Wisnoskie

Affiliation: Novant Health Cancer Institute, Novant Health

Abstract Preview: Purpose: To develop, validate, and commission a VMAT Total Body Irradiation (TBI) workflow by integrating publicly available resources, commercial solutions, and in-house testing to enhance treatment ...

Comparison of Dose Metrics to Critical Heart Substructures for Different Planning Techniques, and Scan Techniques for Right Sided Breast Irradiation

Authors: Wesley A. Belcher, Aidan Burke, Matthew Green, Taylor Stamey

Affiliation: ECU Health, East Carolina University Brody School of Medicine

Abstract Preview: Purpose: The purpose of this study was to determine the effect of using deep inhalation breath hold (DIBH) vs. free breathing (FB) and intensity-modulated radiation therapy (IMRT) vs. 3D for right-sid...

Comprehensive Analysis of Plan Modulation in SRS/SBRT Plans: A Single Institution Study of 461 Cases

Authors: Yunfeng Cui, Will Giles, Xinyi Li, Ke Lu, Jennifer C. O'Daniel, Anna E. Rodrigues, Chunhao Wang, Lana Wang, Yibo Xie, Sua Yoo, Jingtong Zhao

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose:
To establish quantitative measurement of plan modulation for SRS/SBRT treated with Volumetric Modulated Arc Therapy (VMAT) on C-arm LINACs.
Methods:
A total of 461 plans were analyze...

Correcting for the Cherenkov-to-Dose Conversion for Tset Patients Using Monte Carlo Simulations

Authors: Baozhu Lu, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: Cherenkov intensity can be quantitatively correlated to surface dose but need certain corrections for accurate dose measurements. This study aims to investigate the impact of incident beam an...

Cumulative Doses in Radiotherapy Treatment of Lymphoma Patients

Authors: Klaus Bacher, Tom Boterberg, Jeff Rutten, Barbara Vanderstraeten, Gwenny Verfaillie, Sarah Waelkens

Affiliation: Ghent University, Ghent University Hospital

Abstract Preview: Purpose: Lymphoma cancer patients frequently receive ionizing radiation during their treatment trajectory, including diagnostic CT, planning CT (pCT), recurrent CBCTs, radiotherapy (out-of-field) dose...

Developing a Comprehensive Multi-Modal Framework for Population-Scale Liver Volumetry: Insights and Predictive Models

Authors: Mustafa Bashir, Diana Kadi, Kyle J. Lafata, Jacob A. Macdonald, Mark Martin, Yuqi Wang, Marilyn Yamamoto

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Department of Electrical and Computer Engineering, Duke University, Department of Radiology, Duke Unversity

Abstract Preview: Purpose: To develop a high-throughput, automated-data-interrogation pipeline for integrating imaging and clinical information to identify key determinants of liver volume (LV), enabling population-sca...

Development of Patient-Specific Lead Ball Compensator for Total Body Irradiation

Authors: Chang Heon Choi, Minjae Choi, Yoonsuk Huh, Jin Jegal, Jung-in Kim, So-Yeon Park

Affiliation: Department of Radiation Oncology, Veterans Health Service Medical Center, Department of Radiation Oncology, Seoul National University Hospital

Abstract Preview: Purpose: Total Body Irradiation (TBI) aims to achieve a uniform dose distribution across the entire body. However, in conventional TBI setups that use extended source-to-surface distance (SSD) and lea...

Development of a Whole-Body Blood Flow Framework Based on the Icrp Blood Phantom

Authors: Jung Han Nam, Wonmo Sung

Affiliation: Department of Biomedical Engineering and Biomedicine & Health Sciences, College of Medicine, The Catholic University of Korea, Department of Biomedical Engineering and Biomedicine & Health Sciences, College of Medicine, The Catholic University of Korea, Seoul, Korea

Abstract Preview: Purpose: This study aims to develop a whole-body blood flow framework based on the ICRP 145 standard vascular phantom to simulate the spatiotemporal trajectories of blood cells in the human vasculatur...

Do We Need Pediatric-Specific Models for Radiotherapy Auto-Contouring? a Comparative Study of Pediatric and Adult-Trained Tools

Authors: Gregory T. Armstrong, James E. Bates, Christine V. Chung, Lei Dong, Ralph Ermoian, Jie Fu, Christine Hill-Kayser, Rebecca M. Howell, Meena S. Khan, Sharareh Koufigar, John T. Lucas, Thomas E. Merchant, Taylor Meyers, Tucker J. Netherton, Constance A. Owens, Arnold C. Paulino, Sogand Sadeghi

Affiliation: Department of Radiation Oncology, University of Washington and Fred Hutchinson Cancer Center, Department of Epidemiology and Cancer Control, St. Jude Children’s Research Hospital, St. Jude Children's Research Hospital, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Department of Radiation Oncology, St. Jude Children’s Research Hospital, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, University of Washington/ Fred Hutchinson Cancer Center, Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University, The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences

Abstract Preview: Purpose: Clinical workflows often rely on auto-segmentation tools trained on adult data, which may exhibit suboptimal performance in pediatric imaging due to inherent anatomical variations and smaller...

Dosimetry Comparison of Surface-Guided and Orthogonal X-Ray Film-Based Setups for Proton Pencil-Beam Scanning in Breast Cancer Treatment

Authors: Darren Kaplan, Chenguang Liu, Mark Pankuch

Affiliation: Northwestern Medicine Proton Center

Abstract Preview: Purpose: This study evaluates the hypothesis that surface-guided radiation therapy for the breast or chest wall using proton PBS provides comparable target coverage and OARs sparing to x-ray-based IGR...

Enhancing Urethral Visualization for Prostate SBRT Using Post-Void T2-Weighted Imaging on a Low-Field 0.35T MR-Linac System

Authors: Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: Accurate delineation of the urethra is critical for optimizing tumor control and minimizing urethral toxicity in prostate stereotactic body radiation therapy (SBRT). The purpose of this study...

Evaluating Normal Tissue Toxicity Following Pulsed Low Dose Rate Radiotherapy

Authors: Shahabeddin mostafanazhad Aslmarand, Lili Chen, Dusica Cvetkovic, Troy A. Dos Santos, Chang Ming Charlie Ma, Dae-Myoung Yang

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose:
Pulsed low-dose-rate radiotherapy (PLDR) has been proposed to reduce normal tissue toxicity while maintaining tumor control comparable to conventional radiotherapy (CRT). This study assess...

Evaluating the Adequacy of Planning Target Volume Margins in Lung Stereotactic Body Radiation Therapy: Assessment of Intrafraction Motion Using a Fiducial Marker

Authors: Rashmi Benda, Qinghao Chen, Shifeng Chen, Giovanni Lasio, Peter Olivieri, Huijun Xu, Junliang Xu, Byong Yong Yi, Baoshe Zhang, Jinghao Zhou

Affiliation: University of Maryland Baltimore Washington Medical Group, Department of Radiation Oncology, University of Maryland School of Medicine, Capital Region Medical Center, University of Maryland Shore Regional Cancer Center

Abstract Preview: Purpose:
We investigated if the patients receiving lung stereotactic body radiation therapy (SBRT) have adequate planning target volume (PTV) margins by evaluating the intrafraction motion using a ...

Evaluating the Radiological Safety of 64Cu-Macrin in PET/MRI Studies through Radiopharmaceutical Dosimetry

Authors: Alejandro Bertolet, Mislav Bobić, Carlos Huesa-Berral, Aileen O'Shea, Ralph Weissleder

Affiliation: Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: To develop a pipeline for estimating the absorbed dose to various organs from positron emission tomography (PET) combined with magnetic resonance imaging (MRI). We use this pipeline to evalua...

Evaluation of Cherenkov Imaging for Dose Verification in Total Skin Electron Therapy

Authors: Petr Bruza, David J. Gladstone, Lesley A Jarvis, Natasha Mulenga, Kevin J. Willy

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center

Abstract Preview: Purpose: The goal of this work was to use Cherenkov emission imaging to verify patient position, accessory block positioning and dose delivery in Total Skin Electron Therapy (TSET).

Methods: A ...

Evaluation of MRI Distortion across a Multi-Site Health System and the Importance of MRI Distortion QA in Stereotactic Radiosurgery (SRS)

Authors: Emel Calugaru, Jenghwa Chang, Sean T Grace, Nicholas Harvey, Jessica Jung, Ching-Ling Teng

Affiliation: Northwell, Hofstra University, Hofstra University Medical Physics Program

Abstract Preview: Purpose: To evaluate the consistency of MRI distortion corrections across Northwell Health system and evaluate the necessity and importance of distortion QA for MRIs used for stereotactic radiosurgery...

Evaluation of Treatment Delivery Efficiency and Workflow Optimization in Prostate Stereotactic Body Radiation Therapy: A Comparative Study of C-Arm and O-Ring Linear Accelerators

Authors: Yijian Cao, Jenghwa Chang, Lyu Huang

Affiliation: Northwell, Hofstra University Medical Physics Program

Abstract Preview: Purpose: This study evaluates the treatment delivery efficiency and workflow of two advanced linear accelerator systems—Varian’s TrueBeam (C-arm) and Halcyon (O-ring)—for prostate Stereotactic Body Ra...

Evaluation of Treatment Planning Feasibility and Dosimetric Quality of the Reflexion™ X1 System for Complex Spinal Targets

Authors: Thomas I. Banks, Bin Cai, Andrew R. Godley, Yang Kyun Park, Hao Peng, Rameshwar Prasad, Chenyang Shen, Shunyu Yan, Haozhao Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose:
The RefleXion® X1 (RefleXion Medical, Inc., Hayward, CA) uniquely integrates KVCT and PET as on-board image guidance for radiotherapy. It has been installed and commissioned for clinical u...

Eye-Tracking Analysis of Radiologist Preferences in PET Imaging: Comparing 5-Ring and 6-Ring Detector Configurations

Authors: Samuel L. Brady, Joseph G. Meier, Elanchezhian Somasundaram, Andrew T Trout

Affiliation: Cincinnati Children's Hospital Medical Ctr, Cincinnati Childrens Hospital Med Ctr

Abstract Preview: Purpose:
To analyze eye-tracker gaze data for insights into radiologists’ areas of focus in an observer study of whole-body PET images.
Methods:
For a comparative study of dose matched PET im...

High-Fidelity Treatment Optimization for Online Adaptive Stereotactic Partial Breast Irradiation: Integrating Dose and Treatment Time Considerations

Authors: Drexell Hunter Boggs, Carlos E. Cardenas, Jingwei Duan, Joseph Harms, Joel A. Pogue, Richard A. Popple, Courtney Bosse Stanley, Dennis N. Stanley, Sean Xavier Sullivan, Natalie N. Viscariello

Affiliation: Washington University in St. Louis, The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: CBCT-guided online adaptive radiation therapy (OART) with Ethos for stereotactic accelerated partial breast irradiation (APBI) can mitigate inter-fraction variation, leading to dosimetric adv...

Impact of Lung Density on Plan Quality and Delivery Parameters in Lung Stereotactic Body Radiation Therapy (SBRT) Plans

Authors: David Chighvinadze, Indra J. Das, Jeremy D. Donaghue, Kevin Stephans, Gregory Videtic, Sugandima Weragoda, Ping Xia

Affiliation: Cleveland Clinic, Cleveland Clinic Sandusky, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Cleveland Clinic Fairview

Abstract Preview: Purpose:: Evaluate the impact of lung density variations on plan quality and delivery parameters in lung SBRT Plans.
Methods: For a hypothetical case with a real patient anatomy, three GTVs with vo...

Investigating the Flash Effect: Uncovering Brain Sparing and Cognitive Preservation across Varying Dose Rates in Whole-Brain Irradiation of in-Vivo Mouse Models

Authors: Denise Dunn, Scott R. Floyd, Tyler V. Kay, Anna Lynnette-Price, Eric L. Martin, Stepan Mikhailov, Taylor Nguyen, Mark Oldham, Victoria J. P. Radosova, Zachary J. Reitman, Ramona Rodriguiz, Andrew Thompson, William Wetsel, Seth Wilcox, Ying Wu

Affiliation: Duke University Mouse Behavior Core, Department of Physics, Duke University, Medical Physics Graduate Program, Duke University, Duke University Medical Physics Program, Duke University, Duke University Mouse Behavioral and Neuroendocrine Analysis Core Facility, Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: FLASH radiation therapy (RT) shows promise for reducing normal tissue damage, though its mechanisms remain unclear. Using an in-vivo model with the High Intensity Gamma-ray Source (HIGS) lina...

Investigation of High Cumulative Doses and Dose Outliers in a Pediatric Hospital

Authors: Niki Fitousi, Stanley Thomas Fricke, Anna Romanyukha

Affiliation: Qaelum NV, Children's National Hospital

Abstract Preview: Purpose:
To identify opportunities for improvement through investigation of outliers in exam dose length product (DLP) and patients receiving high cumulative doses (CED), in the context of our “ped...

Investigation of Treatment Planning System (TPS) Algorithms for Helical Tomotherapy Total Body Irradiation (TBI)

Authors: John T Barrett, Chulhaeng Huh, Farshad Mostafaei, Michelle Rocque, Austin Sanders

Affiliation: Department of Radiation Oncology, Medical College of Georgia, Augusta University, Department of Radiation Oncology, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health

Abstract Preview: Purpose: This study involved the use of Accuray’s TPS (Precision) and RayStation TPS for planning TBI treatments. TBI was delivered using Accuray’s Radixact machine, and dose calculation algorithm, do...

Key Tumor Volume Zones for Advancing the Radiomics-Based Distant Recurrence Prediction

Authors: Ryan Alden, Tithi Biswas, Kaushik Halder, Felix Maria-Joseph, Michael Mix, Rihan Podder, Tarun Kanti Podder

Affiliation: SUNY Upstate Medical University, IIT-Roorkee, University of Florida

Abstract Preview: Purpose: Radiomics feature-based model for predicting distant recurrence can potentially provide critical insight for clinical decision-making and assistance in treatment strategies. This study focuse...

On the Spectral Changes of Magna-Field Photon Beams Used in Total Body Irradiation

Authors: Larry A. DeWerd, Ahtesham Ullah Khan

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Total body irradiation (TBI) technique uses high energy photon beams with extended source-to-surface distances (SSDs) to irradiate the entire patient to prepare them for bone marrow or stem c...

Performance of Photon Counting Detector in a Clinical PCD-CT: A Novel Image-Based Evaluation

Authors: Frank F. Dong, Megan C. Jacobsen, Ke Li, Xinming Liu, John Rong

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose: We aimed to understand the physical performance of a CdTe PCD-based detector system within a whole-body PCD-CT scanner, with the goal of optimizing its clinical application. Instead of relyin...

Protocol for In Vivo Dosimetry Using Myoslchip System: Characterization and Clinical Application

Authors: Jeremy S. Bredfeldt, Daniel W. Cail, Maria A. Czerminska, Cindy I. Hancox, David Hu, Benjamin Karasko, Claire Keun Sun Park

Affiliation: Department of Radiation Oncology, Brigham and Women's Hospital, Harvard Medical School, Brigham and Women's Hospital, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School

Abstract Preview: Purpose: To develop a robust clinical protocol for in vivo dosimetry in radiotherapy using the myOSLchip Optically Stimulated Luminescent Dosimeter (OSLD) system by performing characterization and eva...

Quantitative Image Review Metric for Vertebral Body Misalignment

Authors: Luis E. Fong de los Santos, Douglas John Moseley, Satomi Shiraishi, Cenji Yu

Affiliation: Mayo Clinic

Abstract Preview: Purpose: To quantitatively detect errors in vertebral body localization using normalized cross correlation (NCC)

Methods: Volumetric images of a thoracic end-to-end SBRT phantom with a removabl...

Retrospective Analysis of Shape and Dosage Changes in Structures during Radiotherapy for Head and Neck Cancer Patients Based on Velocity

Authors: Daming LI, Jinsen Xie, Zhe Zhang

Affiliation: Peking University Shenzhen Hospital Radiotherapy Department, School of Nuclear Science and Technology, University of South China

Abstract Preview: Purpose: To analyze the actual doses received during radiotherapy for head and neck cancers (HNC) using Velocity, providing insights for adaptive radiotherapy decision-making.
Methods: Thirty-three...

Spatial Variation and Dosimetry of X-Ray Contamination in Total Skin Electron Beam Therapy

Authors: William G. Breen, Dalton Griner, Scott C Lester, Joseph John Lucido, Beth A. Schueler, Jack C. Thull

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Designing a total skin electron (TSE) beam therapy protocol requires finding the optimal balance between penetration depth, field uniformity, and x-ray contamination (XC). To better understan...

Streamlining Direct-to-Unit Clinical Set-Ups for Radiation Therapy

Authors: Lori Buchholtz, Alison Garda, Chris L. Hallemeier, Kathryn L. Kolsky, Han Liu, Joseph John Lucido, Marisa Schinter, Andrew J. Veres, Sara Walerak

Affiliation: Mayo Clinic

Abstract Preview: Purpose: The C_START initiative aims to streamline and simplify the Direct-to-Unit (DtU) clinical setup and treatment planning process for photon radiation therapy, particularly for emergent cases suc...

Targeted Multi-Criteria Optimization for Rapid Improvement of Organ-at-Risk Dose in the Setting of Prostate Stereotactic Body Radiation Therapy

Authors: Alyssa Gadsby, William J. Godwin, Daniel G. McDonald, Jean L. Peng, Alek K. Rapchak, Sean A Roles, Austin M. Skinner, Stephanie Tan

Affiliation: Medical University of South Carolina

Abstract Preview: Purpose: To utilize multi-criteria optimization (MCO) in a targeted fashion to quickly and easily improve dose to the rectum when treating the prostate with stereotactic body radiation therapy (SBRT)....

The Impact of Intempo Imaging on Cyberknife Prostate Plans

Authors: Lei Fu, Eric Gressen, Yingcui Jia, Shari Rudoler, Yevgeniy Vinogradskiy, Qianyi Xu

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: InTempo imaging in the Accuray CyberKnife System improves the ability to track/correct target motion during treatment. However, no studies have provided information on the impact of InTempo I...

Three-Dimensional Reconstruction of Triggered Images with Dehazing Algorithm for Precise Intrafraction Motion Detection in Spine SBRT

Authors: Hyosung Cho, Dae Yup Han, Duhee Jeon, Jiwon Park, Hyesun Yang

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose: To precisely detect intrafraction patient motion during spine stereotactic body radiotherapy (SBRT) treatment delivery, we propose an optimized technique for three-dimensional reconstruction ...

Total Body Irradiation Using Field-in-Field Treatment Planning Techniques

Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West

Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma

Abstract Preview: Purpose: To simulate total-body-irradiation (TBI) with field-in-field treatment planning techniques and test portal dosimetry for dose verification and quality assurance.
Methods: CT images of full...

Total Body PET Siemens Healthineers

Authors: Brad J. Kemp

Affiliation: Mayo Clinic

Abstract Preview: N/A...

Treatment Planning System Modelling of a New Commercial Rotational Table

Authors: Michael Armstrong, Courtney R. Buckey, Quan Chen, Suzanne J. Chungbin, Mirek Fatyga, Yi Rong, Jun Tan, Xiang Sheng Yan

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: To model a commercial rotational table in treatment planning system (TPS) for accurate dose optimization and calculation.

Methods: A commercial rotational table (CDR Equilibrium®) is r...