Authors: Mitya M. Barreto, Nichole A. Harris
Affiliation: Department of Radiology, University Hospitals Cleveland Medical Center
Abstract Preview: Purpose: To evaluate dosimeter dependence of measured AGD, and to develop a dosimeter independent method for evaluating the AGD, for CEDM exposures.
Methods: Three solid-state dosimeters (Raysafe-X...
Authors: Arpit M. Chhabra, J Isabelle Choi, Minglei Kang, Haibo Lin, Hang Qi, Charles B. Simone, Shouyi Wei, Irini Yacoub, Francis Yu, Xingyi Zhao, Ajay Zheng
Affiliation: New York Proton Center, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose:
Pencil beam scanning (PBS) proton therapy effectively treats ocular cancer by minimizing exit doses to normal tissues. However, challenges remain in sparing nearby organs-at-risk(OARs). Ul...
Authors: Benjamin W. Maloney, Ashley E. Rubinstein, Colin Schaeffer, Justin Yu
Affiliation: Henry Ford Health
Abstract Preview: Purpose: Radiography AEC systems ensure correctly exposed images for varied kVp and patient thicknesses. The specific kVp and PMMA thicknesses selected for testing AEC tracking may affect passing rate...
Authors: Wesley E. Bolch, Chansoo Choi, Robert Joseph Dawson, Bangho Shin, Yitian Wang
Affiliation: University of Florida
Abstract Preview: Purpose: The skeleton plays a critical role in dosimetry, containing red bone marrow (RBM) and bone endosteum (BE), which are closely linked to radiation-induced leukemia and bone cancer. While severa...
Authors: Hannah Grover, Andrew J. Sampson
Affiliation: Oregon Health & Science University, UT Health San Antonio
Abstract Preview: Purpose: The goal of this work was to quantify the dosimetric impact of iodinated contrast on fibroglandular breast tissue to better inform clinical risk and benefit assessments when determining the m...
Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski, Huanyi Zhou
Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation
Abstract Preview: Purpose: A new CT configuration utilizing a multiple X-ray-source array (MXA) is under development to mitigate cone-beam (CB) artifacts in single-rotation wide coverage imaging. We investigate the sam...
Authors: Kainoa Calistro-Allen, Brendon J. Villegas
Affiliation: University of Alabama Birmingham
Abstract Preview: Purpose:
To compare differences in radiation output and image quality in clinical esophagrams across fluoroscope vendors in use at University of Alabama Birmingham, prompted by reports that a newly...
Authors: Klaus Bacher, Tom Boterberg, Jeff Rutten, Barbara Vanderstraeten, Gwenny Verfaillie, Sarah Waelkens
Affiliation: Ghent University, Ghent University Hospital
Abstract Preview: Purpose: Lymphoma cancer patients frequently receive ionizing radiation during their treatment trajectory, including diagnostic CT, planning CT (pCT), recurrent CBCTs, radiotherapy (out-of-field) dose...
Authors: Janet Ching-Mei Feng, Janet Gutierrez, Aylin Ozus, Patricia Svolos
Affiliation: Bellaire High, McGovern Medical School, University of Texas Health Science Center at Houston, Environmental Health & Safety, University of Texas Health Science Center at Houston, UTHealth McGovern Medical School
Abstract Preview: Purpose: Exposure to radiation may become harmful to the fetus depending on the gestational age and absorbed dose. The Nuclear Regulatory Commission states the radiation exposure to the embryo/fetus o...
Authors: Philip Blumenfeld, Jon Feldman, Yair Hillman, Michael Marash, Aron Popovtzer, Alexander Pryanichnikov, Shimshon Winograd, Marc Wygoda, Vered Zivan
Affiliation: Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), P-Cure Ltd./Inc., Sharett Institute of Oncology, Hadassah Medical Center, Hebrew University of Jerusalem
Abstract Preview: Purpose:
Image-guided adaptive proton therapy (IGAPT) allows tailored dose adjustments to account for anatomical and physiological changes during treatment. Recent efforts have developed a cost-eff...
Authors: Ulrike Dydak, Chia-Tien Hsu, Chang Geun Lee, Cora Mizimakoski, Humberto Monsivais, Jae Hong Park
Affiliation: Purdue University
Abstract Preview: Purpose: Overexposure to manganese (Mn) from inhaling welding fumes can lead to cognitive and motor deficits. We developed a whole-brain Mn-mapping approach to detect subtle but significant increases ...
Authors: Gregory J Bootsma, Tunok Mondol
Affiliation: University Health Network, Princess Margaret Cancer Center
Abstract Preview: Purpose:
To evaluate the impact of prototype fluence field modulation (FFM) cone-beam CT (CBCT) on dose reduction and image quality using Monte Carlo simulations. This study particularly looks at t...
Authors: Caroline Cheney, Nicole M. Lafata, Zaiyang Long, Dustin W. Lynch, Erin B. Macdonald, Andy Madore, Douglas E. Pfeiffer, Colin Schaeffer, Alexander W. Scott
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, UVA Health, Duke University Health System, Mayo Clinic, Henry Ford Health, Boulder Community Health, Varian, Cedars-Sinai Medical Center
Abstract Preview: Purpose: This work evaluates the significance of performing established radiography automatic exposure control (AEC) tests by comparing testing methodology, outcomes, and failure rates across multiple...
Authors: Curtiland Deville, Rachel B. Ger, Heng Li, Todd R. McNutt
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University
Abstract Preview: Purpose: Proton therapy patients receive quality assurance CT scans (QACTs) during treatment to verify dosimetric accuracy and determine adaptive therapy needs as proton treatments are highly sensitiv...
Authors: Frank F. Dong, Megan C. Jacobsen, Ke Li, Xinming Liu, John Rong
Affiliation: UT MD Anderson Cancer Center
Abstract Preview: Purpose: We aimed to understand the physical performance of a CdTe PCD-based detector system within a whole-body PCD-CT scanner, with the goal of optimizing its clinical application. Instead of relyin...
Authors: Marwan Belal AbuHaija, Anis Ahmad, Chase Prescott Anderson, Nesrin Dogan, John C. Ford, Alan Pollack, Junwei Shi, Jorge D Vega, Gabriel Enrique de Hostos
Affiliation: University of Miami, University of Miami Sylvester Comprehensive Cancer Center
Abstract Preview: Purpose: Raman Spectroscopy (RS) is a non-invasive, label free imaging modality that gathers intrinsic molecular vibrational information. Portable RS systems expand affordability and convenience, supp...
Authors: Jeremy S. Bredfeldt, Daniel W. Cail, Maria A. Czerminska, Cindy I. Hancox, David Hu, Benjamin Karasko, Claire Keun Sun Park
Affiliation: Department of Radiation Oncology, Brigham and Women's Hospital, Harvard Medical School, Brigham and Women's Hospital, Brigham and Womenβs Hospital and Dana Farber Cancer Institute, Harvard Medical School
Abstract Preview: Purpose: To develop a robust clinical protocol for in vivo dosimetry in radiotherapy using the myOSLchip Optically Stimulated Luminescent Dosimeter (OSLD) system by performing characterization and eva...
Authors: Brendon J. Villegas
Affiliation: University of Alabama Birmingham
Abstract Preview: Purpose: The Cumulative Air Kerma (CAK) has traditionally been a surrogate metric for patient exposure to ionizing radiation during clinical esophagrams. Recently, UAB technologists observed that a ne...
Authors: Nrusingh C. Biswal, Manas R. Gartia, Maria Iftesum, Sanjit K. Roy, Gyana Ranjan Sahoo, Elnaz Sheikh, Hem D. Shukla, Madhur Srivastava
Affiliation: Department of Chemistry and Chemical Biology, Cornell University, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Mechanical and Industrial Engineering, Louisiana State University
Abstract Preview: Purpose: Prostate cancer incidence and mortality levels in African-American men are the highest among all ethnic groups. This points to the role of biological factors in driving disparate outcomes. He...
Authors: Angela Gearhardt, Stephen F. Kry, Christopher Ryan Peeler, Julianne M. Pollard-Larkin
Affiliation: The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences; The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: A growing number of radiation therapy (RT) patients have cardiovascular implantable electronic devices (CIEDs). Patients with CIEDs must be carefully managed because the devices are susceptib...