Search Submissions 🔎

Results for "tracking proton": 14 found

Combining Flat-Panel Imaging and Internal BB Markers for Precise HDR Brachytherapy Source Localization

Authors: Yibin Ling, Qihui Lyu, Ke Sheng

Affiliation: University of California Berkeley, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
High Dose Rate (HDR) brachytherapy enables radiation to concentrate on the tumor by sending the high-dose-rate radioactive source directly to the treatment site. On the other hand, the sha...

Deep Learning-Based Denoising for Template Matching in Real-Time Tumor Tracking Using Kv Scattered X-Ray Imaging

Authors: Weikang Ai, Xiaoyu Hu, Xun Jia, Kai Yang, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Department of Biomedical Engineering, Johns Hopkins University, Johns Hopkins University

Abstract Preview: Purpose: Real-time tumor tracking is critically important for respiratory motion management for lung cancer radiotherapy. A previously proposed application of a photon counting detector involves measu...

Deep Learning-Based Eye Monitoring and Tracking System for Ocular Proton Therapy in a Regular Gantry Room

Authors: David H. Abramson, Christopher Barker, Jasmine H. Francis, Meng Wei Ho, Yen-Po Lee, Haibo Lin, Hang Qi, Andy Shim, Charles B. Simone, Weihong Sun, Xiaoxuan Xu, Siyu Yang, Francis Yu, Anna Zhai

Affiliation: College of Machine Intelligence, Nankai University, New York Proton Center, Department of Biomedical Engineering, Johns Hopkins University, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Proton therapy is an effective modality for treating ocular tumors such as uveal melanoma. We developed a novel camera‐based eye‐tracking system to provide real-time noninvasive eye positioni...

Deep Learning-Based Segmentation Using Cine Epid Images for Real-Time Tumor Monitoring

Authors: Fumiaki Komatsu, Shunsuke Moriya, Ryosuke Nakamura, Takeji Sakae, Toshiyuki Terunuma, Tetsuya Tomita

Affiliation: Graduate School of Comprehensive Human Sciences, University of Tsukuba, Institute of Medicine, University of Tsukuba, Proton Medical Research Center, University of Tsukuba, Department of Radiology, University of Tsukuba Hospital

Abstract Preview: Purpose: To develop a deep learning (DL) model capable of accurately tracking lung tumors independent of beam angle variations.
Methods: A thoracic dynamic phantom simulating lung motion in the sup...

Development of a Visualization Tool for LET and Proton Spot Mapping for PB Treatment Planning

Authors: Chang Chang, Mohammad Kanber, Stephen Kenneth Northway

Affiliation: East Carolina University, California Protons Cancer Therapy Center, California Proton Cancer Therapy Center

Abstract Preview: Purpose:
Proton therapy treatment planning involves the consideration of unique physical quantities such as Linear Energy Transfer (LET) and spot location maps that do not exist in photon treatment...

Does the Method Matter? How in Hominum, In Vivo, in silico, and in Phantasma Measures Compare and Contrast Is Assessing the Utility of Photon Counting CT?

Authors: Ehsan Abadi, Njood Alsaihati, Steven T. Bache, Mridul Bhattarai, Cindy Marie McCabe, Francesco Ria, Ehsan Samei

Affiliation: Duke University, Center for Virtual Imaging Trials, Duke University, Duke University Health System, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: To compare and contrast alternative methods including reader (in hominum), phantom (in phantasma), in vivo, and in silico methods deployed to assess the performance of photon counting (PCCT) ...

Efficient Monte Carlo Proton Dose Calculation Using Denoising Diffusion Probabilistic Models

Authors: Chieh-Ya Chiu, Shen-Hao Li, Hsin-Hon Lin, Shu-Wei Wu

Affiliation: Department of Medical Imaging and Radiological Sciences, Chang Gung University, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital Linkou

Abstract Preview: Purpose: Monte Carlo simulation enables precise calculation of dose distribution in proton therapy through tracing the radiation particles with patient tissues. However, achieving clinical-level preci...

Evaluation of an Analytical Simulation Technique By Comparing Transmitted Spectra Against GEANT4 through a Hafnium-Loaded Heterogeneous Phantom

Authors: Sabrina Campelo, Sandun Y. Jayarathna, Adam D. Melancon, Paige L. Nitsch, Christopher Ryan Peeler, Julianne M. Pollard-Larkin, Ramaswamy Sadagopan, Xiaochun Wang, George Zhao

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Development of an in-house analytical simulation for streamlining photon counting detector (PCD) system protocols through measuring transmitted photon energy spectra through a Hafnium (Hf)-lo...

Investigation on Quantifying Chemical Species Post Electron and Proton Irradiation Using the Geant4-DNA 'UHDR' Example

Authors: Konstantinos Chatzipapas, George C. Kagadis, Panagiotis Konstas, Dimitris N. Mihailidis, Dimitris Visvikis

Affiliation: LaTIM, INSERM UMR1101, University of Pennsylvania, LaTIM, INSERM, University of Brest, University of Patras

Abstract Preview: Purpose: This study investigates the temporal evolution of radiolytic species (H3O+, OH•, OH-) in water under electron and proton irradiation using the mesoscopic chemistry model that allows longer te...

Leveraging Photon Counting Detector CT and Advance Reconstructions to Improve the Accuracy of Vessel Tracing in Prostate Artery Embolization

Authors: Christopher P. Favazza, Andrea Ferrero, Taylor Froelich, Forrest Linch, Scott Thompson

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Photon counting detector (PCD) CT is a promising tool to enhance pre-procedural planning and intra-procedural guidance for prostate artery embolization due to its unsurpassed ultra-high spati...

Patient-Specific Orthogonal Projection Based Real-Time Volumetric X-Ray Imaging for Proton Therapy

Authors: Hao Chen, Kai Ding, Xiaoyu Hu, Xun Jia, Heng Li, Devin Miles

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Accurately delivering radiation dose is critical in intensity-modulated proton therapy (IMPT), where intrafraction motion management plays a pivotal role. Our proton therapy system equipped x...

Proton CT-Imaging and Radiography Using 3D-Detector with Plastic Scintillators for on-Board Proton Imaging

Authors: Salahuddin Ahmad, Imad M. Ali, Zaid Alkalani, Nesreen Alsbou

Affiliation: University of Oklahoma, University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: To design and evaluate a 3D-detector for proton CT-imaging and radiography, utilizing volumetric plastic scintillator detector exposed to high-energy therapeutic beams from proton therapy sys...

Single Plane Positioning Tracking Proton and Helium Pencil Beam Radiographs: Phantom Study

Authors: Anahita Bakhtiari Moghaddam, Don F. DeJongh, Ethan DeJongh, Jennifer Hardt, Oliver Jäkel, Lukas Martin, Alexander Pryanichnikov, Joao Seco, Christina Stengl, Niklas Wahl

Affiliation: Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Division of Biomedical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), ProtonVDA LLC, Department of Physics and Astronomy, Heidelberg University, Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT)

Abstract Preview: Purpose:
To evaluate the feasibility and performance of single-plane position tracking for proton and helium pencil beam radiography using a prototype imaging system, with the goal of providing a c...

The Dosimetric and Dose RATE Characteristics for Bragg Peak Proton MINI-Ridge Filter Flash in Comparison to Conventional Proton and Filter Free Flash for Breast and Prostate

Authors: Jenghwa Chang, Chingyun Cheng, J Isabelle Choi, Muhammad Hamza, Minglei Kang, Tyler Kaulfers, Grant Lattery, Haibo Lin, Charles B. Simone, Xingyi Zhao

Affiliation: Peking University, Hofstra University Medical Physics Program, New York Proton Center, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Physics and Astronomy, Hofstra University, Physics Resident at Montefiore Einstein, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: In terms of high dose rate FLASH, the question remains on how to properly deliver treatment and what clinical sites are feasible to deliver such treatment. The novel Bragg peak (BP-FLASH) and...