Search Submissions 🔎

Results for "trial dosimetry": 21 found

Characterization of HCC Tumor Response in 90Y-Radioembolization Clinical Trial RAPY90D Using Prospective Voxel Dosimetry

Authors: E Courtney Henry, Srinivas Cheenu Kappadath, Armeen Mahvash

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Characterization of hepatocellular carcinoma (HCC) tumor responses for single-arm single-center prospective 90Y-radioembolization clinical trial (n=40) that used patient-specific voxel-dos...

Clinical Trial Reporting, Reproducibility, and Standardization: Consistency for Implementation.

Authors: Stella Flampouri, Heng Li, Sarah Quirk, Timothy Ritter, Mihaela Rosu-Bubulac, Toni M. Roth, Michael B. Roumeliotis, Koren Smith, Wade P. Smith

Affiliation: Johns Hopkins University, Virginia Commonwealth University, University of Washington, VCU Health System, UMass Chan Medical School/IROC RI, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Emory University, Brigham and Women's Hospital; Harvard Medical School, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To assess clinical trial reproducibility for translation to standard clinical care in radiation therapy.
Methods: The systematic review adheres to the Preferred Reported Items for Systemat...

Deformable Scintillator Array Dosimetry for In Vivo Volumetric Dose and Dose-Rate Validation of Uhdr Proton Therapy

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Joseph Harms, Anthony E. Mascia, Brian W Pogue, Roman Vasyltsiv, Zhiyan Xiao, Rongxiao Zhang, Yongbin Zhang

Affiliation: Cincinnati Children's Proton Therapy Center, University of Missouri, Dartmouth College, Thayer School of Engineering, Dartmouth College, Washington University in St. Louis, University of Wisconsin - Madison

Abstract Preview: Purpose: With developing FLASH trials requiring diligent delivery monitoring, current proton therapy in-vivo dosimetry (IVD) cannot provide comprehensive verification, including dose and dose-rate vol...

Development of Preclinical Multiscale Dosimetry for Beta-Particle Emitting Radionuclide in Radiopharmaceutical Therapy

Authors: Adedamola Adeniyi, Bryan Bednarz, Malick Bio Idrissou, Reinier Hernandez, Ohyun Kwon, Brian W. Miller, Zachary S Morris, Maya Takashima, Jamey Weichert

Affiliation: Departments of Radiation Oncology and Medical Imaging, University of Arizona, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin–Madison, Department of Radiology, School of Medicine and Public Health, University of Wisconsin–Madison, Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin–Madison

Abstract Preview: Purpose: As radiopharmaceutical therapy (RPT) becomes more prevalent in clinical applications, understanding dose-response relationships in the tumor microenvironment (TME) and normal tissues is essen...

Dosex As a per-Pulse Uhdr and Conventional Electrometer Compatible with Sandard Clinical Probes

Authors: Petr Bruza, David J. Gladstone, Austin Sloop, Rongxiao Zhang

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Health

Abstract Preview: Purpose: UHDR-specific probes are becoming available on the market but often demand high costs and long order times. The reduced sensitivity of these probes often imposes challenges when measuring con...

Early GU Toxicity Prediction in Prostate SBRT Using Delivered Dosimetry Via Long Short-Term Memory Model

Authors: Amar Kishan, Jun Lian, Yunkui Pang, Jonathan Pham, X. Sharon Qi, Michael Steinberg, Luca F Valle, Pew-Thian Yap

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of North Carolina at Chapel Hill

Abstract Preview: Purpose: Stereotactic body radiotherapy (SBRT) is a highly effective treatment for prostate cancer, yet predicting genitourinary (GU) toxicity has primarily relied on planned dosimetry. This study inv...

Evaluating 177Lu-PSMA-I&t Reconstruction Parameter Influences on Image Quality and Quantification

Authors: Martin Auerbach, Jeremie Calais, Johannes Czernin, Magnus Dahlbom, Zachary Ells, Adrien Holzgreve, Koichiro Kimura, Karam Masri, Catherine (Caffi) Meyer, David Sennung

Affiliation: Department of Nuclear Medicine, UCLA, UCLA, University of California, Los Angeles

Abstract Preview: Purpose: Lutetium-177 PSMA SPECT/CT imaging offers the possibility of qualitative image analysis for tumor response assessment and quantitative image analysis for individualized dosimetry. However, th...

Evaluating the Radiological Safety of 64Cu-Macrin in PET/MRI Studies through Radiopharmaceutical Dosimetry

Authors: Alejandro Bertolet, Mislav Bobić, Carlos Huesa-Berral, Aileen O'Shea, Ralph Weissleder

Affiliation: Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: To develop a pipeline for estimating the absorbed dose to various organs from positron emission tomography (PET) combined with magnetic resonance imaging (MRI). We use this pipeline to evalua...

Implementing TG-191 for Robust Calibration of Scintillation Imaging As a Clinical dosimetry Tool

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Lesley A Jarvis, Allison Matous

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose: Scintillation imaging has demonstrated unique advantages to existing clinical in vivo dosimetry (IVD) techniques by enabling full-field visualization, direct comparison to the treatment plan,...

Intra-Organ Blood Vessel Mapping in Mice for Improved Pre-Clinical Radiation Dosimetry

Authors: Daylin Barroso, Chris Beekman, Wesley E. Bolch, Natalia Estefania Carrasco-Rojas, Robert Joseph Dawson, Walter Murfee, Harald Paganetti, Andrew Robert Sforza, Julia D. Withrow

Affiliation: Massachusetts General Hospital - Harvard Medical School, Massachusetts General Hospital, University of Florida

Abstract Preview: Purpose: To develop methods for quantifying the interaction of radiation with blood in the mouse whole body (MOBY) phantom for dosimetric applications. The most important of these are modeling the dis...

MR-Based Functional Liver Imaging and Dosimetry to Predict Albi Change Post-SBRT

Authors: Madhava Aryal, James M. Balter, Yue Cao, Daniel T Chang, Kyle Cuneo, Joseph R. Evans, Theodore Lawrence, John Rice, Randall K. Ten Haken, Lise Wei

Affiliation: University of Michigan, Department of Radiation Oncology University of Michigan

Abstract Preview: Purpose: This study aims to identify predictors of global liver function change measured by albumin-bilirubin (ALBI) score following stereotactic body radiation therapy (SBRT) in hepatocellular carcin...

Optimal Choice of Companion Radiotracer for TAT 225Ac-Mti-201.

Authors: Vinay K Banka, Mikalai Budzevich, William R. Gibbons, Mark L. McLaughlin, Jacob Moriarty, Eduardo G. Moros, David L. Morse, Christopher J. Tichacek, Thad J. Wadas

Affiliation: Modulation Therapeutics Inc, Moffitt Cancer Center, University of Iowa

Abstract Preview: Purpose: A targeted alpha therapy drug, 225Ac-MTI-201, has been developed targeting the Melanocortin 1 Receptor for metastatic uveal melanoma and is currently in FIH clinical trials. Since alpha emiss...

Phase One Randomized Two-Arm Dose Escalation of Flash RT in Veterinary Canine Osteosarcoma: Trial Design & Initial Results

Authors: Wesley S. Culberson, Aleksandra Ilina, Brian W Pogue, Matthew Reed, Connor Strainis, William Scott Thomas, Nathaniel Van Asselt, Albert van der Kogel

Affiliation: University of Wisconsin: Madison, University of Wisconsin: Madison School of Veterinary Medicine, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin–Madison, University of Wisconsin-Madison, University of Wisconsin - Madison

Abstract Preview: Purpose: FLASH radiotherapy reduces skin damage in vivo from ultra-high dose rate (UHDR) irradiation relative to conventional dose rates (CDR), while preserving damage to tumor tissue. The FLASH effec...

Quantification of Global Dosimetry Audit Performance: Assessing the Sensitivity and Specificity of Dosimetry Audits to Establish Reciprocity Among Different International Clinical Trials Credentialing Organizations

Authors: Fre'Etta Brooks, Catharine H Clark, Patricia Diez, Peter B. Greer, Hideaki Hirashima, Rebecca M. Howell, Mohammad Hussein, Stephen F. Kry, Joerg Lehmann, Jessica Lye, Mitsuhiro Nakamura, Christopher L. Nelson, Rushil Patel, Christine Peterson, Julianne M. Pollard-Larkin

Affiliation: Kyoto University, The University of Texas MD Anderson Cancer Center, Radiotherapy Trials Quality Assurance Group, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Medical Physics & Biomedical Engineering, University College London, Metrology for Medical Physics, National Physical Laboratory, Austin Health, University of Washington Medical Center, University of Newcastle

Abstract Preview: Purpose: To assess the consistency of end-to-end dosimetry audits currently used by different international clinical trial QA organizations with the goal of harmonizing audits and reducing audit overl...

Real-Time Output Gating and Fault Handling for an Uhdr Mobetron

Authors: Petr Bruza, David J. Gladstone, Lesley A Jarvis, Austin Sloop, Kevin J. Willy, Rongxiao Zhang

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose:
Active beam monitoring and output-gated dosimetry are essential systems for safe and accurate radiation delivery. UHDR irradiators such as the Mobetron rely on pre-programmed regimes and t...

Retrospective Evaluation of Combined Photon SBRT and Radium-223 SPECT Based Radiopharmaceutical Therapy Tumor Dosimetry in Clinical Trial Patient Cases

Authors: David P. Adam, Allison Cartee, Eric C. Frey, Michael Ghaly, Bin He, Robert Francois Hobbs, Natalie Rose Kania, Ana Kiess, Ian Marsh, Bonnie N. C. President, Steven Rowe, George Sgouros, Phuoc Tran, Hao Wang

Affiliation: Johns Hopkins University, Radiopharmaceutical Imaging and Dosimetry, LLC (Rapid), 2The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins Medical Institute, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Oncology, Johns Hopkins University, School of Medicine, Department of Radiology, University of North Carolina, Chapel Hill

Abstract Preview: Purpose: Advanced treatment paradigms combining SPECT/CT imageable, alpha emitting, radiopharmaceutical therapy (RPT) and stereotactic body radiotherapy (SBRT) can provide the potential of dose escala...

SPECT/CT Multimodal Segmentation of Bone Marrow for Theranostic Dosimetry

Authors: Tommaso Frigerio, Joshua Genender, John M. Hoffman, Catherine (Caffi) Meyer

Affiliation: UCLA, David Geffen School of Medicine at UCLA

Abstract Preview: Purpose: Accurate bone marrow segmentation is required for bone marrow dosimetry to monitor for dangers in PSMA-Lu177 radioligand therapy. We introduce a hybrid (AI/semantic knowledge) segmentation pi...

Technique Factors Optimization and Radiation Dosimetry of an Upright, Short-Scan, Cone-Beam, Dedicated Breast CT System

Authors: Stephen Araujo, Jing-Tzyh Alan Chiang, Cynthia E. Davis, Eri Haneda, Andrew Karellas, Thomas C Larsen, William Ross, Hsin Wu Tseng, Srinivasan Vedantham, Pengwei Wu

Affiliation: Department of Biomedical Engineering, The University of Arizona, GE Aerospace Research, Department of Medical Imaging, The University of Arizona, GE HealthCare Technology & Innovation Center

Abstract Preview: Purpose: To determine the system parameters and technique factors for image acquisition needed so that the mean glandular dose (MGD) of approximately 4.5 mGy is not exceeded for a recently developed, ...

Towards Clinical Translation: Optical Methods Deliver in-Vivo per-Pulse Dosimetry in Electron Flash-RT

Authors: Petr Bruza, Rafael Carballeira, Megan Clark, David J. Gladstone, Austin Sloop, Roman Vasyltsiv, Kevin Jacob Willy

Affiliation: Dartmouth College, Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: Develop an optical dosimetry system to accomplish standard of care on-patient dosimetry and pretreatment quality assurance for ultra-high dose rate (UHDR) electron therapy ahead of human tria...

Voxel-Dose Implications of Single-Compartment Dosimetry for Ablative 90Y-Radioembolization Segmentectomy

Authors: Srinivas Cheenu Kappadath, Benjamin P. Lopez, Armeen Mahvash

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose: 90Y-radioembolization is utilized with curative intent. While single-compartment doses to the perfused volume for the complete pathologic necrosis (CPN) of tumors have been reported, the actu...

“You Can’t Unsee It”: Clinical Scintillation Imaging Enables First Localized Comparison between In Vivo dosimetry Measurements and the Treatment Plan

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Lesley A Jarvis, Allison Matous

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose: In vivo dosimetry (IVD) is underutilized, in part, because measured point doses cannot be accurately localized to the patient or treatment planning system (TPS), complicating the clinical and...