Authors: Neil A. Kirby, Parker New, Niko Papanikolaou, Holly Paschal, Karl H. Rasmussen, Daniel L. Saenz
Affiliation: UT Health San Antonio
Abstract Preview: Purpose: To simplify the traditional method of patient-specific skin collimation and improve the precision of electron radiotherapy treatment with a new surface conforming collimation system.
Metho...
Authors: Walaa Abdelfadeel, Reagan Thomas Dugan, Tiffany Kinsey, Cameron Kofler, Zheng Feng Lu, Ingrid S. Reiser, Gregory Stacy, Sara Wallace
Affiliation: University of Chicago Medicine, University of Chicago
Abstract Preview: Purpose: To develop an accurate, vendor-neutral method for estimating geometric magnification at the plane of the hip joint on standing anterior-posterior (AP) radiographs for digital templating of to...
Authors: Arjit K. Baghwala, Sunan Cui, Jessica Fagerstrom, Eric C. Ford, Kristi Rae Gayle Hendrickson, Sharareh Koufigar, Samuel Ming Ho Luk, Bishwambhar Sengupta, Afua A. Yorke
Affiliation: University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Department of Radiation Oncology, University of Vermont Medical Center, University of Washington and Fred Hutchinson Cancer Center, Houston Methodist Hospital
Abstract Preview: Purpose: The global burden of cancer continues to rise, leading to an increased workload in radiation oncology clinics. This surge is not only due to the growing demand for treatment machines and moda...
Authors: Dominique Guillet, Arthur Lalonde, Bryan R. Muir, James Renaud, Karim Zerouali
Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal, National Research Council
Abstract Preview: Purpose:
To evaluate the dose rate dependence, beam quality dependence, and short-term stability of a novel flashDiamond (fD) prototype detector for conventional and ultra-high dose rate (UHDR) bea...
Authors: Alexander Choi, William Ross Green, Christine Hill-Kayser, Gary D. Kao, Michael LaRiviere, Rafe A. McBeth, Steven Philbrook
Affiliation: Department of Radiation Oncology, University of Pennsylvania
Abstract Preview: Purpose: To validate the potential of clinical deployment of an in-house AI-driven auto-segmentation tool for pediatric craniospinal irradiation (CSI) in proton therapy, with goals of reducing manual ...
Authors: Ting Chen, Siming Lu, Tanxia Qu, Hesheng Wang
Affiliation: NYU Langone Health
Abstract Preview: Purpose: This study, the first in a two-part series, aims to determine the isocenter position and size for the MR Linac UNITY, focusing on the central axis (CAX) alignment of its Multi-Leaf Collimator...
Authors: Yaowen Cao, Yunwen Huang, Yidong Yang, Xiaogang Yuan, Ning Zhao, Cheng Zheng
Affiliation: Department of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China
Abstract Preview: Purpose: MRI has better soft tissue contrast than cone beam CT which is commonly used in image guided radiotherapy. This study aims to develop a low-field MRI system for precision small animal radiati...
Authors: Pierre Gardair, Johnathan E Leeman, Claire Keun Sun Park, Atchar Sudhyadhom
Affiliation: Brigham and Womenβs Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Womenβs Hospital and Dana Farber Cancer Institute, Harvard Medical School,, Brigham and Womenβs Hospital and Dana Farber Cancer Institute, Harvard Medical School, Harvard Medical School
Abstract Preview: Purpose: Dose is a poor surrogate for radiobiological damage but no in vivo technology exists to directly measure damage such as DNA strand breaks and free radical generation (FRG). Recent advances in...
Authors: Cambridge L Bui-Nguyen, Alexander S. Nguyen, Liqiang (Lee) Tao
Affiliation: Varian AOS @Epic Care, UC Berkeley
Abstract Preview: Purpose: Dynamic Winston-Lutz (WL) testing provides a comprehensive framework for evaluating the accuracy of isocenter alignment. This study investigates the impact of dynamic beam modulation, such as...
Authors: Blessing Chinelo Akah, Daniel W. Neck, David J. Perrin, Sotirios Stathakis
Affiliation: Mary Bird Perkins Cancer Center
Abstract Preview: Purpose: To assess the reliability of the Aktina Isopoint software in evaluating different components of the linear accelerator for optimized quality assurance and linac performance
Methods: The Ak...
Authors: Noriko Kishi, Takashi Mizowaki, Mitsuhiro Nakamura, Yukine Shimizu
Affiliation: Kyoto University, Kyoto Univercity, Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University
Abstract Preview: Purpose: To predict tumor positions in markerless dynamic tumor tracking (ML-DTT)-VMAT by compensating for the asynchrony between the tumor and the diaphragm.
Methods: Rotational fluoroscopic X-ray...
Authors: Ndey Badjan, Chris Beasley, Issack Boru, Josh Joyner, Erica Owenby, Scott H. Robertson, Nicholas Said
Affiliation: Duke University Health System
Abstract Preview: Purpose:
To design MRI-visible laterality markers to boost patient safety by minimizing errors in laterality and subsequent procedures.
Methods:
The markers were made using commercially avail...
Authors: Liu Hong, Zhong Su
Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)
Abstract Preview: Purpose: During treatment delivery on TrueBeam platform 2.7, Triggered Imaging (TI) enables kV images acquisition at regular intervals and Auto Beam Hold (ABH) provides beam pausing if the target is m...
Authors: Emily Hansen, Alois M. Ndlovu, Niara Rowe, Roland Teboh
Affiliation: Hackensack University Medical Center
Abstract Preview: Purpose: The accuracy of SCINTIX biology-guided radiotherapy (BgRT) on the RefleXion X1 is dependent on the correct alignment of the isocenter between all subsystems, including setup lasers, kV imagin...
Authors: Jorge De La Cerda, Andrew Joseph Fanning, Tianzhe Li, Xiaofei Liang, Grace Murley, Mark Pagel, William Schuler, Renee Tran, Shuo Wang, Su-Min Zhou
Affiliation: University of Wisconsin Madison, University of Nebraska Medical Center, University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Electron paramagnetic resonance imaging (EPRI) can be used to image partial pressure of oxygen (pO2) in tumor models. The goal of this study is to develop an Oxygen Enhanced EPRI protocol to ...
Authors: Kevin M Brom, Josep Chorro Bas, RosaAnna Chorro Bas, Andres Climent Rubio, Jaydev K. Dave, Tobias Kummer, Larissa Shiue, Donald J Tradup
Affiliation: Mayo Clinic, Prehospital Critical Care Training Group
Abstract Preview: Purpose: To design and evaluate the functionality of a vascular flow phantom for contrast-enhanced ultrasound imaging (CEUS).
Methods: A microcontroller-generated signal was amplified by a cust...
Authors: Hao Chen, Kai Ding, Xiaoyu Hu, Xun Jia, Heng Li, Devin Miles
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University
Abstract Preview: Purpose: Accurately delivering radiation dose is critical in intensity-modulated proton therapy (IMPT), where intrafraction motion management plays a pivotal role. Our proton therapy system equipped x...
Authors: Teh Lin, Anna Oneil
Affiliation: Fox Chase Cancer Center
Abstract Preview: Purpose: Four-dimensional computed tomography(4DCT) is often required to assess organ motions for thoracic and abdominal cancer patients. This study proposes a quality assurance (QA) procedure for two...
Authors: Stephen Araujo, Jing-Tzyh Alan Chiang, Cynthia E. Davis, Eri Haneda, Andrew Karellas, Thomas C Larsen, William Ross, Hsin Wu Tseng, Srinivasan Vedantham, Pengwei Wu
Affiliation: Department of Biomedical Engineering, The University of Arizona, GE Aerospace Research, Department of Medical Imaging, The University of Arizona, GE HealthCare Technology & Innovation Center
Abstract Preview: Purpose: To determine the system parameters and technique factors for image acquisition needed so that the mean glandular dose (MGD) of approximately 4.5 mGy is not exceeded for a recently developed, ...
Authors: Freeman Jin, Paul J. Keall, Alistair MacDonald, Adam Mylonas, Chandrima Sengupta
Affiliation: Image X Institute, Faculty of Medicine and Health, University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney, Image X Institute, School of Health Sciences, University of Sydney
Abstract Preview: Purpose: During radiation therapy, tumours in the prostate may move from the planned treatment position, leading to significant dose deviations above clinical tolerances Surveys have indicated the nee...
Authors: Joseph A. Miccio, Nicholas J. Potter, Zain Siddiqui
Affiliation: Penn State Health Milton S. Hershey Medical Center
Abstract Preview: Purpose: Fiducial markers are the gold standard for prostate alignment during CT-based image-guided radiotherapy (IGRT). Radiopaque hydrogel rectal spacers reduce rectal toxicity by displacing the rec...