Search Submissions 🔎

Results for "type reference": 17 found

A Refined Model of Reference Mesh-Type Female Breast Model Vasculature and Glandular Structures for Internal Circulating Lymphocyte Dosimetry

Authors: Wesley E. Bolch, Carlos G. Colon-Ortiz, Robert Joseph Dawson, Lazaro Fuentes Alfonso, Shreya P. Pathak, Julia D. Withrow

Affiliation: University of Florida

Abstract Preview: Purpose: To develop tetrahedral mesh-based tissue models within the breasts of the International Commission on Radiological Protection (ICRP) adult female mesh-type reference computational phantom (AF...

An International Survey of High Dose Rate Brachytherapy Dosimetry Practices

Authors: Anna Becker, Tomislav Bokulic, Mauro Carrara, Krzysztof Chelminski, Larry A. DeWerd, Alexis Dimitriadis, Benjamin Kellogg, Malcolm R. McEwen, Zakithi L.M Msimang, Mark J. Rivard, Thorsten Sander, Thorsten Schneider, Jamema Swamidas, Egor Titovich, Paula Toroi, Carlos E. de Almeida, Jacco de Pooter, Liset de la Fuente Rosales, Deborah G. van der Merwe

Affiliation: Radiation and Nuclear Safety Authority, University of Zagreb, National Physical Laboratory, IAEA, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Rio de Janeiro State University, Dosimetry Laboratory, Dosimetry and Medical Radiation Physics Section, Division of Human Health, International Atomic Energy Agency, Physikalisch-Technische Bundesanstalt, National Metrology Institute, University of the Witwatersrand, Dosimetry and Medical Radiation Physics Section, Division of Human Health, International Atomic Energy Agency, National Research Council, Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: The recently published IAEA-TRS-492 international code of practice (CoP) aims at improving traceability, accuracy, and consistency in Brachytherapy Dosimetry. To assess current approaches to ...

Comparison of Computed Tomography Scanner Protocols Using an in-House Automated Method across Machines at a Single Institution

Authors: Matthew R. Hoerner, Maryam Naseri, Mena Shenouda

Affiliation: Yale University School of Medicine, Yale University

Abstract Preview: Purpose: To evaluate acquisition parameters of computed tomography (CT) scanner protocols across different machines to provide patients and clinicians consistent care and image quality, respectively.<...

Computed Tomography Organ Dose Library Derived from Newly Developed Newborn-Infant-Toddler Computational Phantoms

Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Adam Leon Kesner, Cameron B. Kofler, Juan Camilo Ocampo Ramos, Yitian Wang, Stefan Wehmeier

Affiliation: University of Chicago, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson

Abstract Preview: Purpose: To develop a slice-specific computed tomography (CT) organ dose library using Monte Carlo radiation transport simulations on a newly created set of newborn, infant, and toddler computational ...

Diffusion Model-Based Motion Correction in Portable Computed Tomography for Brain: Human Observer Study

Authors: Rajiv Gupta, Rehab Naeem Khalid, Min Lang, Michael H Lev, Quirin Strotzer, Matthew Tivnan, Maryam Vejdani-Jahromi, Dufan Wu, Siyeop Yoon, Chen Zhennong

Affiliation: Massachusetts General Hospital

Abstract Preview: Purpose: Patient motion is a major source of artifacts in portable brain CT due to the slow scanning speed. A diffusion model was developed to reduce these motion artifacts. This work aims to assess t...

Evaluation of the Hyperscint RP-200 Plastic Scintillation Dosimetry System for Reference Dosimetry in Ultra-High Dose Rate Electron Beam Therapy: A Comparative Study

Authors: Julie Colnot, Eric Deutsch, Christelle Huet, Danahé LeBlanc, Pauline Maury, Charlotte Robert, Imane Saïd Mansour, Cathyanne Schott, Francois Therriault-Proulx

Affiliation: INSERM U1030, Gustave Roussy, University Paris-Saclay, LDRI, IRSN, Medscint, THERYQ / INSERM U1030, Gustave Roussy, University Paris-Saclay, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique

Abstract Preview: Purpose: FLASH radiotherapy, using ultra-high dose rates (UHDR, >100 Gy/s), spares healthy tissues while maintaining tumor control compared to conventional radiotherapy (CONV). However, UHDR dosimetry...

Gene Interaction-Encoded Deep Learning Uncovers Microenvironment for Radiation-Induced Pulmonary Fibrosis

Authors: Md Tauhidul Islam, Junyan Liu, Lei Xing

Affiliation: Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose: Radiation-induced lung injury (RILI) is a common complication in patients receiving radiotherapy for lung cancer, with approximately 16%–28% developing pulmonary fibrosis. The exact mechanism...

Icrp Mesh-Type Reference Computational Phantoms Representing Pregnant Women and Fetuses

Authors: Wesley E. Bolch, Chansoo Choi, Chan Hyeong Kim, Suhyeon Kim, Bangho Shin, Yeon Soo Yeom

Affiliation: Hanyang University, University of Florida, 2) Department of Radiation Convergence Engineering, Yonsei University

Abstract Preview: Purpose: Task Group 103 of International Commission on Radiological Protection (ICRP) recently released new-generation adult and pediatric mesh-type reference computational phantoms (MRCPs) via ICRP P...

Investigation of High Cumulative Doses and Dose Outliers in a Pediatric Hospital

Authors: Niki Fitousi, Stanley Thomas Fricke, Anna Romanyukha

Affiliation: Qaelum NV, Children's National Hospital

Abstract Preview: Purpose:
To identify opportunities for improvement through investigation of outliers in exam dose length product (DLP) and patients receiving high cumulative doses (CED), in the context of our “ped...

Multi-Center Diffusion-Weighted MRI Validation for 0.35T MR-Linac: A Repeatability and Reproducibility Study

Authors: Tess Armstrong, Nema Bassiri, Alonso N. Gutierrez, Michael Kasper, Natalia Lutsik, Eric Mellon, Kathryn E. Mittauer, Siamak P. Nejad-Davarani, Shyam Pokharel, Suresh Rana, Hui Wang, Joseph Weygand

Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, Miami Cancer Institute, Baptist Health South Florida, ViewRay, Inc., Miami Cancer Institute, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida, Department of Radiation Oncology, University of Miami

Abstract Preview: Purpose: Radiation treatments on the MR-linac (MRL) enable daily acquisition of anatomical and physiological images for adaptive treatment planning. The apparent diffusion coefficient (ADC) estimated ...

Parameterized Dosimetric Models of the Lumbar Vertebrae for Patient-Informed Active Marrow Dosimetry in Radiopharmaceutical Therapy

Authors: Wesley E. Bolch, Chansoo Choi, Robert Joseph Dawson, Michael Lassmann, Maikol Salas-Ramirez, Bangho Shin, Johannes Tran-Gia, Yitian Wang

Affiliation: Department of Nuclear Medicine, University Hospital Würzburg, University of Florida

Abstract Preview: Purpose: Conduct a parameterized library of mesh-type skeletal models across the lumbar vertebrae. In radiopharmaceutical dosimetry, the hematopoietic active bone marrow is typically a dose-limiting n...

Refresher Training - a Method to Ensure Radioactive Material Program Compliance

Authors: Robert A. Rodgers

Affiliation: Vanderbilt University School of Medicine

Abstract Preview: Purpose: Preparing for radioactive material (RAM) program audits or inspections can be stressful. A five-step method to ensure program compliance is described. This method is adaptable to implementing...

S Values for a Monkey Computational Model for Internally Distributed Radiation Sources

Authors: Jae Won Jung, Daniel Lee

Affiliation: Thomas S. Wootton High School, East Carolina University Brody School of Medicine

Abstract Preview: Purpose: Monkeys have played a key role in enhancing our understanding of the behavior of radioactive materials within living organisms in the field of nuclear medicine. However, detailed dosimetric d...

Standardizing Hybrid Angio-CT Procedure Terminology: Mapping to Acr Common Lexicon for Future Drl Establishmen

Authors: Manuel M. Arreola, Hugh Davis, Daniella Fabri, Emily L. Marshall, BC Schwarz

Affiliation: University of Florida

Abstract Preview: Purpose:
This study aims to map procedure names, descriptions, and CPT codes from a Hybrid Angio-CT room to the American College of Radiology (ACR) Common Lexicon. This mapping will support expedit...

Streamlining Orthovoltage QA: Feasibility of IC Profiler Dosimetry and Workflow Optimization

Authors: Huixiao Chen, Zhe (Jay) Chen, MinYoung Lee, Sameer Taneja

Affiliation: Yale School of Medicine, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: Superficial radiation therapy uses low-energy x-rays to treat various types of cancers, including non-melanoma skin cancers, and dermatological conditions such as keloid scars, mycosis fungoi...

Temporal Drift in Ir-192 Source Strength Measurements: A Braphyqs Multi-Center Analysis

Authors: Åsa K. Carlsson Tedgren, Taran Hellebust, Antonio Herreros, Jacob Johansen, Christian Kirisits, Panagiotis Papagiannis, Mark J. Rivard, Frank-Andre Siebert, Frank Verhaegen, Javier Vijande, Jan Wiersma, Marisol de Brabandere, Ruud van Leeuwen

Affiliation: UKSH, Campus Kiel, Klinik für Strahlentherapie (Radioonkologie), Department of Oncology, The Norwegian Radium Hospital, Oslo University Hospital, Radiation Physics, Department of Medicine and Health (IMH), Linköping University, Radiation Oncology Department, Hospital Clínic-Universitat de Barcelona, IDIBAPS, IFIC-UV, Radiation Oncology, Amsterdam UMC location University of Amsterdam, Department of Radiation Oncology, Radboud University Medical Center, Department of Oncology, Aarhus University Hospital, University Hospital Gasthuisberg, Dept. of Radiation Oncology, Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna, Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: This study, which was carried out by the GEC-ESTRO BRAPHYQS working group, reports the increasing divergence between clinical reference air kerma rate (RAKR) measurements and vendor-provided ...

Variance and Estimation of Patient Specific S-Values for I-131 Administration.

Authors: Jae Won Jung, Choonsik Lee, Jason C. Mace, Sergio Morato Rafet

Affiliation: East Carolina University, Carilion Clinic, National Cancer Institute

Abstract Preview: Purpose: Dosimetry for radionuclides used in nuclear medicine can be accurately calculated if sufficient data is available. However, in most cases crucial information cannot or will not be known a pri...