Search Submissions 🔎

Results for "use printing": 24 found

3D Printed Electron Block Aperture Generation

Authors: David Chighvinadze, Lisa Czaplicki, Jeremy D. Donaghue, Lama K. Muhieddine Mossolly

Affiliation: Cleveland Clinic Sandusky, Cleveland Clinic Strongsville, Cleveland Clinic Fairview

Abstract Preview: Purpose:
Current electron block generation requires manual cutting of stryofoam and placement for pouring of the block which can lead to possible miscutting of blocks, and non-accurate rotations co...

A 3D Printed Ion Chamber Insert Solution for Absolute Dosimetry with Varying Ionisation Chambers in Radiosurgery.

Authors: Shashanksharad Kale, Gopishankar Natanasabapathi, Daya Nand Kishore Sharma

Affiliation: All India Institute of Medical Sciences (AIIMS), Department of Radiation Oncology, All India Institute of Medical Sciences

Abstract Preview: Purpose:
The study demonstrates a novel 3D printing method to fabricate an ion chamber insert (ICI) for absolute dosimetry purpose in gamma knife radiosurgery (GKRS).
Methods:
Our institute u...

A Dosimetric Study of Range-Compensated Proton Arc Therapy

Authors: Alonso N. Gutierrez, Daniel E. Hyer, Blake R. Smith

Affiliation: Miami Cancer Institute, Baptist Health South Florida, Iowa Health Care, University of Iowa

Abstract Preview: Purpose: To perform a feasibility study of optimizing and producing a compact range compensator to deliver single-energy pencil beam scanning (PBS) proton arc therapy treatments. Omitting energy chang...

A Novel 3D Printed Tool to Enable Faster More Accurate Patient Positioning for Electron Radiotherapy

Authors: Christopher J. Mart, Daniel G. McDonald, Inna V. McGowin, Sean A. Roles

Affiliation: Medical University of South Carolina

Abstract Preview: Purpose: To improve the efficiency and accuracy of the positioning process for electron treatments by providing a pointer system for patient alignment to central axis (CAX) of the field at the correct...

Absorption and Material Property Characteristics of 3D-Printing Filaments Based on Monte-Carlo Simulations and Spectral Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: 3D printing has the potential for producing materials useful for the imaging field. This work aims to identify absorption (attenuation coefficient) and material properties (effective atomic n...

Application and Analysis of Advanced 3D Printed Materials As Bolus for Radiation Therapy

Authors: Rami M. Shorti, Gary R. Stinnett

Affiliation: Intermountain Health, Radiation Oncology, Intermountain Health, Advanced Visualization Engineering Department

Abstract Preview: Purpose: In this work we present the workflow, materials analysis, and lessons learned from leveraging advanced 3D printing Polyjet Technology to print conformal bolus for radiation therapy.
Method...

Assessment of the Radiological Features of 3D-Printed Polylactic Acid Composites for Creating Personalized Dosimetric Phantoms

Authors: Ashish Binjola, Raj Kishore Bisht, Natanasabapathi Gopishankar, Pratik Kumar, Daya Nand Kishore Sharma, Sukhvir Kishore Singh, Subramani Vellaiyan

Affiliation: Medical Physics Unit, All India Institute of Medical Sciences, All India Institute of Medical Sciences, Department of Radiological Safety, Institute of Nuclear Medicine and Allied Sciences, Department of Radiation Oncology, All India Institute of Medical Sciences

Abstract Preview: Purpose: Additive manufacturing is increasingly being explored to create dosimetry phantoms. Commercial anthropomorphic phantoms represent an average patient and lack anatomical variations due to obes...

Automated Parametric Custom Collimator Creation for Preclinical Irradiation Studies

Authors: Muhammad Ramish Ashraf, Dixin Chen, Lloyd Emmanuel Kamole Ghomsi, Edward Elliot Graves, Billy W Loo, Stavros Melemenidis, Joseph B. Schulz, Lawrie Skinner

Affiliation: Department of Radiation Oncology, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Precise beam collimation is essential in preclinical radiotherapy studies to ensure accurate dose delivery. Manual design and fabrication of organ-specific collimators usually consist of mult...

COMS Eye Plaque Builds Using 3D Printed Template Stamps and Duralay

Authors: Vishruta A. Dumane, Andrew Lukban, Charlotte Elizabeth Read, Mario Serrano-Sosa, Ren-Dih Sheu, Nadia M. Vassell

Affiliation: Icahn School of Medicine at Mount Sinai, Mount Sinai Beth Israel

Abstract Preview: Purpose:
Defined seed positions are used when following the COMS formalism for eye plaques. Au inserts are typically used as templates for placement of radioactive seeds and then covered in Duralay...

Comparative Analysis of Soft Tissues and 3D Printing Materials Using Euclidean Distance for Linear Attenuation Coefficient

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Elsa Bifano Pimenta

Affiliation: University of São Paulo (USP), Institute of Physics

Abstract Preview: Purpose: This study evaluates the similarity between the linear attenuation coefficients of soft tissues and 3D printing materials in diagnostic imaging range using the Euclidean distance approach.

Design and Construction of a Geometrical and Head Phantom with Internal Carotid Inserts for Flow Simulation in Image-Derived Input Function with 3T and 7T MR-Brainpet Insert Studies.

Authors: Dirk Grunwald, Hans Herzog, Hidehiro Iida, N. Jon Shah, Usman Khalid, Manfred Lennartz, Philipp Lohmann, Ceren Memis, Tobias Meurer, Claudia Regio Brambilla, Jürgen Scheins, Lutz Tellmann, Christoph W. Lerche, Martin Wiesmann, Karl Ziemons

Affiliation: FH Aachen University of Applied Sciences, Department of Chemistry and Biotechnology, Clinic for Diagnostic and Interventional Neuroradiology, Uniklinik Aachen,, Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH,, Central Institute for Engineering, Electronics and Analytics (ZEA-1), Forschungszentrum, Turku PET Center, Institute of Biomedicine, Faculty of Medicine, University of Turku,

Abstract Preview: Purpose: Quantitative brain studies with positron emission tomography (PET) often require an arterial input function (AIF), which traditionally requires arterial cannulation. However, this is invasive...

Design of a Small Animal Proton Flash Irradiation System with High Achievable Dose and Dose Rate Using a Synchrotron Proton Beamline

Authors: Zongsheng Hu, Yuting Li, Radhe Mohan, Emil Schueler, Uwe Titt

Affiliation: The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: In previous work, we developed an irradiation system for pre-clinical ultra-high-dose-rate(FLASH) radiotherapy experiments based on synchrotron proton beamline. However, the beam current limi...

Determination of Optimal Surface Rois for Sgrt-Guided Dibh Treatment of Abdominal Cancer

Authors: Megan E. Daly, Ajay Fernandez, Ryan D. Hernandez, Soo Kyoung Kim, Arta Monjazeb, Minahal Naveed, Peter C. Park, Jotsna Singh, Payton H. Stone

Affiliation: UC Davis Cancer Center

Abstract Preview: Purpose: To identify optimal deep-inspiration breath-hold (DIBH) surface-guided radiotherapy (SGRT) regions of interest (ROIs) for abdominal stereotactic body radiation therapy (SBRT) treatments.
M...

Development and Validation of Patient-Specific 3D-Printed Electron Applicators for Precision Radiotherapy

Authors: Md. Jobairul Islam

Affiliation: Department of Radiation Oncology, Labaid Cancer Hospital and Super Speciality Centre

Abstract Preview: Purpose: Electron radiotherapy is an effective treatment for superficial tumors but requires field-shaping devices like electron applicators, which are labor-intensive to produce. This study aimed to ...

Development of Patient-Specific Lead Ball Compensator for Total Body Irradiation

Authors: Chang Heon Choi, Minjae Choi, Yoonsuk Huh, Jin Jegal, Jung-in Kim, So-Yeon Park

Affiliation: Department of Radiation Oncology, Veterans Health Service Medical Center, Department of Radiation Oncology, Seoul National University Hospital

Abstract Preview: Purpose: Total Body Irradiation (TBI) aims to achieve a uniform dose distribution across the entire body. However, in conventional TBI setups that use extended source-to-surface distance (SSD) and lea...

Development of a Novel 3D-Printed Heterogeneous Phantom for Liver SBRT Dose Verification in Hepatocellular Carcinoma (HCC) Treatment.

Authors: Dr. Sheaka Alobaidli, Anju K V, Dr. Chiranjib Konar, Sreejesh MS, Dr. Vijayaprabhu N, Dr. Deepti Sharma, Dr. Hanuman Prasad Yadav

Affiliation: Amity Institute of Applied Sciences, Kuwait Cancer Control Center, Institute of Liver and Biliary Sciences, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Amity institute of Applied Sciences, Amity University, Institute of Liver and Biliary Sciences(ILBS)

Abstract Preview: Purpose:
The accuracy of dose delivery in stereotactic body radiotherapy (SBRT) is critical for effectively treating hepatocellular carcinoma (HCC). This study aims to develop patient-specific 3D-p...

End-to-End Pre-Planning Needle Trajectory and Dwell Time Optimization for 3D Printable Cervical and Vaginal Templates

Authors: Deidre Batchelar, Michael Kudla, Stephanie Merkl, Tony Teke

Affiliation: BC Cancer - Kelowna

Abstract Preview: Purpose: Preplanning 3D-printed templates for cervical and vaginal brachytherapy is an iterative process, often taking hours to for an individual patient.
This study demonstrates an end-to-end auto...

Feasibility of 3D Printing for Fabricating Anthropomorphic Kidney Phantoms

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Wagner Henrique Marques, Raphael Morata, Victor H.F Oliveira

Affiliation: University of São Paulo (USP), Institute of Physics

Abstract Preview: Purpose: This study investigates the feasibility of 3D printing materials in creating anthropomorphic kidney phantoms that accurately simulate the radiological properties of human tissues, for applica...

First Phantom Testing of Biology-Guided Radiotherapy for Sequential Integrated Boost Radiotherapy

Authors: Girish Bal, David J. Carlson, Huixiao Chen, Zhe (Jay) Chen, Emily A. Draeger, Dae Yup Han, Henry S. Park

Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: This study explores the feasibility, accuracy, and dosimetric performance of hybrid biology-guided radiotherapy (BgRT) combined with image-guided radiotherapy (IGRT) for delivering sequential...

Ir-192 Percentage Depth Ionization of PLA and Ballistic Gelatin Compared to Water

Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Ching-Ling Teng, Nadia M. Vassell

Affiliation: Northwell, Mount Sinai Beth Israel

Abstract Preview: Purpose:
The flexible nature of ballistic gelatin and 3D printed material such as PLA lend themselves to phantom studies in brachytherapy. While these materials can allow for easy simulation of cat...

Low-Cost Image Quality Assurance Phantom Customization Via Additive Manufacturing

Authors: Sarah E. Holler, Daniel Johnson

Affiliation: Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: As the technological availability of modern clinical infrastructure increases in resource-restricted regions of the world, the needs to maintain quality standards of practice need not be hamp...

Novel Use of 3D Printing for Pre-Operative Dose Estimation in the First Case of Gammatile Spine Implantation

Authors: Ali Al Asadi, Amanda Lynn DiCarlo, Anthony J. Doemer, Jessie Y. Huang, Ian Y Lee, Alexandra Moceri, Adam Robin, Lisa Scarpace, Mira Shah, Salim Siddiqui, Kundan S Thind

Affiliation: Henry Ford Innovations, Henry Ford Health

Abstract Preview: Purpose: For a patient who had two previous courses of external beam therapy for rectosigmoid adenocarcinoma and presented with painful, recurrent disease in the sacrum, this study describes the first...

On Dosimetric Water Equivalency of 3D Printed Materials

Authors: Emily Helen Hayes, Luke Maloney

Affiliation: University of Florida

Abstract Preview: Purpose: To determine the dosimetric water equivalency of polylactic acid (PLA) and commercial 3D printing resin using electron stopping power as a surrogate, for use in radiochromic film calibration ...

Spectral CT Assessment of 3D Printing Techniques for Improving the Uniformity and Reproducibility of Models Applied in Medical Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: Filament deposition modeling (FDM) 3D printers may utilize proprietary calibration methods inadequate for medical imaging. Proper techniques are necessary to achieve imaging uniformity standa...