A Comparative Study of Hypersight and Truebeam Cone Beam Computed Tomography Image Quality

Authors: Sorour Hosseini, YuHuei Jessica Huang, Thomas Boyd Martin, Geoffrey S. Nelson, Nicholas Pierre Nelson, Hui Zhao

Affiliation: University of Utah, Department of Radiation Oncology, Huntsman Cancer Institute, University of Utah

Abstract Preview: Purpose: To evaluate image quality—including noise, contrast-to-noise ratio (CNR), uniformity, and low-contrast visibility (LCV)—on the HyperSight and TrueBeam cone-beam computed tomography (CBCT) pla...

A Comparison of the Impact to Mean Doses to Organs at Risk of Small Versus Large Spot Sizes in Pelvic Proton Therapy

Authors: Jamie s Baker, Sam Beddar, Mahsa Dehghanpour, Ariel MT Hoang, Emma Holliday, Rachael M. Martin Paulpeter, Joshua S. Niedzielski, Luis Augusto Perles, Josie S Ruzek, Gabriel O. Sawakuchi

Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, niversity of Texas MD Anderson Cancer Center School of Health Professions, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, University of Texas MD Anderson Cancer Center School of Health Professions

Abstract Preview: Purpose: This study aims to evaluate the dosimetric impact on organs at risk (OAR) of small versus large spot sizes when treating pelvic cancer patients with pencil beam scanning (PBS) proton therapy....

A Quantitative Analysis of Interplay Effects in IMPT for Lung Cancer SBRT: Comparing Two Machine Delivery Sequence Models

Authors: Xiaoda Cong, Xuanfeng Ding, Gang Liu, Peilin Liu, Lewei Zhao

Affiliation: Department of Radiation Oncology, Stanford University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Corewellhealth William Beaumont University Hospital

Abstract Preview: Purpose: This study quantitatively evaluates the interplay effect in intensity-modulated proton therapy (IMPT) for lung cancer stereotactic body radiotherapy (SBRT) using two different machine deliver...

Absorption and Material Property Characteristics of 3D-Printing Filaments Based on Monte-Carlo Simulations and Spectral Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: 3D printing has the potential for producing materials useful for the imaging field. This work aims to identify absorption (attenuation coefficient) and material properties (effective atomic n...

An OAR Margin Recipe Based on Clinical Data and Including Radio-Sensitivity Variation

Authors: Carlo Greco, Joep Stroom, Sandra Vieira

Affiliation: Champalimaud Center for the Unknown

Abstract Preview: Purpose: RTP safety margins are generally based on geometrical uncertainties alone and not directly on clinical outcome. Here we use clinical dose-constraint data to generate dosimetric margins for OA...

Application and Analysis of Advanced 3D Printed Materials As Bolus for Radiation Therapy

Authors: Rami M. Shorti, Gary R. Stinnett

Affiliation: Intermountain Health, Radiation Oncology, Intermountain Health, Advanced Visualization Engineering Department

Abstract Preview: Purpose: In this work we present the workflow, materials analysis, and lessons learned from leveraging advanced 3D printing Polyjet Technology to print conformal bolus for radiation therapy.
Method...

Assessment of Vasculature Mapping Using Infrared Imaging System for Treatment Planning

Authors: Lily Jo Bertemes, Careesa Billante, Ashley Cetnar, Maximilian Stephen Meineke, Runhe Tan

Affiliation: The James Cancer Center, The Ohio State University, The Ohio State University - James Cancer Hospital

Abstract Preview: Purpose: The response of healthy vasculature due to radiation treatments is an underexplored area of radiation oncology. Understanding the impact of radiation on veins could advance treatment optimiza...

Automated Multimodal Image Registration for Prostate Bed Radiation Treatment

Authors: Quan Chen, Xue Feng, Chunhui Han, Gaofeng Huang, Trevor Ketcherside, Yi Lao, Yun Rose Li, An Liu, Bo Liu, Kun Qing, William T. Watkins

Affiliation: Graduate Program in Bioengineering, University of California San Francisco-UC Berkeley, Department of Radiation Oncology, City of Hope National Medical Center, Mayo Clinic Arizona, Carina Medical LLC

Abstract Preview: Purpose: New treatment platforms such as Ethos (Varian Medical Systems) allow the introduction of multi-modal imaging into adaptive radiotherapy workflow to facilitate an up-to-date view of patients’ ...

Best- and Worst-Case Scenario: Uncertainty Bounds Informed By Daily Scanning in Weekly CBCT-Based Accumulated Dose for Head and Neck Cancer

Authors: Peter Balter, Kristy K. Brock, Clifton David Fuller, Tze Yee Lim, James Long, Brigid A. McDonald, Androniki Mitrou, Andrew J. Schaefer, Stina Svensson

Affiliation: The University of Texas MD Anderson Cancer Center, RaySearch Laboratories, Rice University, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences

Abstract Preview: Purpose: CBCT-based accumulated dose can provide up-to-date dose information on responding anatomy. To optimize resources, it is necessary to determine how many scans provide adequate information for ...

Can We Use Smaller Margin for the Planned Target Volume with Adaptive Radiotherapy?

Authors: Mahmoud H Abdelgawad, Shahabeddin mostafanazhad Aslmarand, Lili Chen, Xiaoming Chen, Ahmed A. Eldib, Teh Lin, Chang Ming Charlie Ma, Robert A. Price

Affiliation: Physics department, Faculty of science, Al-Azhar University, Fox Chase Cancer Center

Abstract Preview: Purpose: Many modern radiotherapy clinics are moving to online adaptive radiotherapy. A recent upgrade of the CBCT-based adaptive radiotherapy system introduced ultra-high-speed image acquisition. Thi...

Clinical Validation of a Deep-Learning Segmentation Tool for Head and Neck Cancer Patients and Thoracic and Abdominal Cancer Patients

Authors: Haijian Chen, Katja M. Langen, William Andrew LePain, Claire Tran, Mingyao Zhu

Affiliation: Emory Healthcare, Emory University, Georgia Institute of Technology

Abstract Preview: Purpose: To validate the performance of a commercial deep-learning segmentation (DLS) tool for head and neck cancer (HNC) and thoracic and abdominal cancer (TAC) by comparing it to manual segmentation...

Comparing SPECT Dose Reconstruction Algorithm Accuracy As a Function of Imaging Parameters

Authors: Srinivas Cheenu Kappadath, Brian Michael Kelley, Benjamin P. Lopez

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Imaging systems are subject to errors from finite spatial resolution and voxel size. This work demonstrates their effect on dose algorithm {Monte Carlo (MC), dose-volume kernel (DVK), and ...

Comprehensive Analysis of Plan Modulation in SRS/SBRT Plans: A Single Institution Study of 461 Cases

Authors: Yunfeng Cui, Will Giles, Xinyi Li, Ke Lu, Jennifer C. O'Daniel, Anna E. Rodrigues, Chunhao Wang, Lana Wang, Yibo Xie, Sua Yoo, Jingtong Zhao

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose:
To establish quantitative measurement of plan modulation for SRS/SBRT treated with Volumetric Modulated Arc Therapy (VMAT) on C-arm LINACs.
Methods:
A total of 461 plans were analyze...

Decreasing the Dependence of CT Number on the Position in the Field-of-View Using Photon Counting Detector CT

Authors: Yanle Hu, Shuai Leng, Cynthia H. McCollough, Maryam Sadeghian, Joe Swicklik

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: The dependence of CT number on position in the field-of-view (FOV) imposes challenges in radiotherapy treatment planning. This study aims to decrease this dependence using photon counting det...

Deep Learning-Based Plan Quality Prediction for Gamma Knife Radiosurgery of Brain Metastases

Authors: Chih-Wei Chang, Runyu Jiang, Mark Korpics, Yuan Shao, Aranee Sivananthan, Zhen Tian, Ralph Weichselbaum, Xiaofeng Yang, Aubrey Zhang, Xiaoman Zhang

Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Chicago, Department of Physics, University of Chicago, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University, School of Public Health, University of Illinois Chicago

Abstract Preview: Purpose: Gamma Knife (GK) plan quality can vary significantly among planners, even for cases handled by the same planner. Although plan quality metrics such as coverage, selectivity, and gradient inde...

Denoising Diffusion-Weighted Images of Rectal Cancer Acquired on a 0.35 T Magnetic Resonance Imaging-Guided Linear Accelerator Using Singular Value Decomposition

Authors: Jacqueline M. Andreozzi, Tess Armstrong, Shiva Bhandari, John M Bryant, Jessica M Frakes, David J. Gladstone, Sarah E Hoffe, Kujtim Latifi, Arash Naghavi, Steven Nichols, Ibrahim M. Oraiqat, Russell Palm, Gage H. Redler, Stephen A Rosenberg, Joseph Weygand

Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, Thayer School of Engineering, Dartmouth College, Department of Radiation Oncology, Ohio State University, Moffitt Cancer Center, Department of Radiation Oncology, Moffitt Cancer Center

Abstract Preview: Purpose: The MR-linac provides unique opportunities for integrating advanced imaging into radiotherapy workflows, but the lower sensitivity of systems like the 0.35T model can pose challenges for diff...

Differential Hole-Size Lattice Patterns for Escalating SFRT Dose to Large, Deep-Seated, and Unresectable Masses

Authors: Joshua Misa, Damodar Pokhrel, William St. Clair

Affiliation: University of Kentucky, Department of Radiation Medicine

Abstract Preview: Purpose: Development of a novel spatially fractionated radiotherapy (SFRT) lattice deployment method featuring a large high-dose sphere at the tumor’s center, surrounded by smaller diameter spheres. W...

Dosimetric Accuracy Evaluation of Brainlab Elements 4.0 Treatment Planning System

Authors: Bhuvaneswari Narayanan, Niko Papanikolaou, Daniel L. Saenz

Affiliation: UT Health San Antonio, University of Texas HSC San Antonio

Abstract Preview: Purpose: To evaluate dosimetric accuracy of Brainlab Elements (BLE) 4.0 treatment planning system (TPS) for linac based SRS and Spine SBRT treatment.
Methods: RT Safe cranial and thorax phantoms wi...

Dosimetry of Gamma Knife Stereotactic Radiosurgery Tissue Heterogeneity Corrections for Pituitary Adenomas

Authors: James M. Brindle, Gene A. Cardarelli, Alexis Leuci, Mark J. Rivard

Affiliation: Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: Leskell GammaPlan (LGP) is equipped with the Collapsed Cone Convolution (CCC) and TMR10 calculation algorithms. Use of the CCC algorithm accounts for tissue heterogeneities not considered in ...

Enhancing Dosimetric Conformity in Single-Energy Bragg Peak Flash Therapy Using Aperture-Based Techniqu

Authors: Chin-Cheng Chen, Chingyun Cheng, Longfei Diao, Benjamin Durkee, Minglei Kang, Haibo Lin, LeLe Liu, Yangguang Ma, Xuanqin Mou, YunTong Pei, Charles B. Simone, YuFei Wang, Xueqing Yan, Xingyi Zhao, Wang Zhengda

Affiliation: Peking University, St. Jude Children's Research Hospital, New York Proton Center, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology, The First Affiliated Hospital of Zhengzhou University, School of Software Engineering, Xi’an Jiaotong University, School of information and communications engineering, Faculty of electronic and information engineering, Xi’an Jiaotong University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: This study evaluates the effectiveness of apertures in improving lateral dose falloff in proton pencil beam scanning (PBS) single-energy Bragg peak (SEBP) FLASH radiotherapy (RT). The approac...

Establishing Tumor Size-Dependent Contrast Requirements for Multi-Target Biology-Guided Radiation Therapy (BgRT)

Authors: Muhammad Ramish Ashraf, Girish Bal, Daniel Pham, Murat Surucu

Affiliation: RefleXion Medical, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University

Abstract Preview: Purpose: To determine minimum target size and FDG contrast thresholds for reliable Biology-guided Radiation Therapy (BgRT) delivery using a systematic phantom study.
Methods: A custom 3D-printed ph...

Evaluation of Deformable Image Registration Accuracy Used in MR-Only Ventilation Mapping

Authors: Fei Han, James M. Lamb, Michael Vincent Lauria, Daniel A. Low, Tessa Elizabeth Maurer, Danilo Maziero, Claudia R. Miller, Drew Moghanaki, Louise Naumann, Nicolas Viot

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, Siemens Healthineers, UCLA, University of California Los Angeles

Abstract Preview: Purpose: Patients with lung disease outside radiotherapy are barred from high dose protocols used for motion modeling, but MRI could offer no-dose alternatives. Image-based ventilation is a promising ...

Evaluation of Nodule Volume Accuracy with Deep Learning-Based Reconstructions on Cdznte Photon-Counting and Energy-Integrating CT

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal

Affiliation: Radboud University Medical Center, University of São Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de Física Gleb Wataghin

Abstract Preview: Purpose: This study aimed to evaluate the precision and accuracy of volume measurements for solid nodules (SNs) and ground-glass opacities (GGOs) in lung images acquired using energy-integrating CT (E...

Evaluation of the Extrapolated Output Factors of Varian's Halycon Beam Model for Fields Smaller Than 1 Cm with AAA and Acurosxb

Authors: Arjit K. Baghwala, Devin J. Olek, Parth K. Patel, Ramiro Pino, Adam Yanez

Affiliation: Houston Methodist Hospital, Kaiser Permanente

Abstract Preview: Purpose: The Halcyon beam model in Eclipse is immutable and only includes output factors (OF) for fields down to 1x1 cm2. The TPS must extrapolate OFs for smaller fields used in stereotactic (SRS/SBRT...

Fine-Tuning AI-Based Generative Models for Small-Sample Glioma MRI Generation.

Authors: Xiangli Cui, Chunyan Fu, Man Hu, Wanli Huo, Jingyu Liu, Jianguang Zhang, Yingying Zhang, Shanyang Zhao

Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University, Departments of Radiation Oncology, Zibo Wanjie Cancer Hospital, Key Laboratory of Electromagnetic Wave Information Technology and Metrology of Zhejiang Province, College of Information Engineering, China Jiliang University, Department of Oncology, Xiangya Hospital, Central South University, College of Information Engineering, China Jiliang University, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University, Shandong Academy of Medical Sciences

Abstract Preview: Purpose: To quantify the impact of fine-tuning strategies for pre-trained AI image generation models on glioma MRI image quality and observer performance, and to determine the optimal fine-tuning conf...

Impact of IMRT Beam Scatter and Electronic Noise on Real-Time Kv and Fluoroscopy Image Quality

Authors: Wei Luo, Cameron Thayer-Freeman, Yifeng Zhao

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky

Abstract Preview: Purpose: Real-time Kilovoltage (kV) imaging has emerged as a powerful clinical aid, providing high-precision localization of moving targets during treatment. However, the Megavoltage (MV) treatment be...

Impact of Respiratory Motion and MRI Sequences on Tumour Volume Determination in MR-Guided Radiotherapy

Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wa Kong, Pei-Xiong Li, Pak Hang Nam, Bin Yang, Siu Ki Yu, Chi To Yung

Affiliation: Medical Physics Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose:
The Elekta Unity system facilitates daily adaptive radiotherapy using MRI-based treatment planning. However, MR images are prone to motion artefacts caused by respiratory motion, potential...

Improving the Robustness of AI-Based Detection and Segmentation for Brain Metastasis By Optimizing Loss Function and Multi-Dataset Training

Authors: Omar Awad, Alfredo Enrique Echeverria, Issam M. El Naqa, Daniel Allan Hamstra, Yiding Han, Ryan Lafratta, Abdallah Sherif Radwan Mohamed, Piyush Pathak, Zaid Ali Siddiqui, Baozhou Sun, Vincent Ugarte

Affiliation: H. Lee Moffitt Cancer Center, Harris Health, Baylor College of Medicine

Abstract Preview: Purpose:
Accurate detection and segmentation of brain metastases are critical for diagnosis, treatment planning, and follow-up imaging but are challenging due to labor-intensive manual assessments ...

Investigation of Flash Proton Irradiation Induced DNA Double Strand Breaks Under Different Free Radical Scavenger Environments

Authors: Hansong Bai, Peter Jermain, Xun Jia, Heng Li, Devin Miles, Daniel Sforza, Michael H. Shang, Daniel Robert Strauss, Keith Unger, Lingshu Yin

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, MedStar Georgetown University Hospital, Johns Hopkins University, Department of Radiation Medicine, MedStar Georgetown University Hospital

Abstract Preview: Purpose: To investigate DNA Double Strand Break (DSB) induced by FLASH proton irradiation in a repair-free plasmid DNA model under different free radical scavenging conditions in plateau and Bragg pea...

Learning from Failures – Case Studies into Failing Patient Specific Quality Assurance Plans

Authors: Christopher S. Melhus, Elizabeth Meyer, Cassandra Stambaugh

Affiliation: Tufts Medical Center

Abstract Preview: Purpose: To investigate the clinical treatment planning parameters that impact patient-specific quality assurance (PSQA) passing rates for hippocampal avoidance whole brain (HAWB) treatment plans.
...

Positional Accuracy and Clinical Recommendations for HDR Brachytherapy Ring Applicators: A Commissioning and Evaluation Study

Authors: Peter G. Maxim, Michael P. Reilly, Mengying Shi, Maryam Shirmohammad, Darren M. Zuro

Affiliation: University of California Irvine

Abstract Preview: Purpose: This study aims to assess the positional accuracy of HDR brachytherapy ring applicators, quantify the extent of positional deviation, and provide clinical recommendations for GYN HDR brachyth...

Qualitative Assessment of Low-Dose 4D Cone-Beam CT Protocols for Daily Lung SBRT Patient Alignment

Authors: Yussuf A. Abdelal, Junguo Bian, Michael Delafuente, Sebastien A. Gros, Hyejoo Kang, Luke Layman, M Mahesh, John C. Roeske

Affiliation: Department of Radiology and Medical Imaging, Stritch School of Medicine, Loyola University Medical Center, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Johns Hopkins Univ

Abstract Preview: Purpose: This study evaluates the feasibility of optimizing 4DCBCT imaging protocols for gated lung SBRT, by reducing dose while maintaining the image quality required for accurate patient alignment.<...

Quantitative Evaluation of Eclipse’s (V18) Ability to Address Dosimetric Leaf Gap Variations

Authors: D. Michael Lovelock, Charlotte Elizabeth Read, Ren-Dih Sheu, Jing Wang, Tingyu Wang

Affiliation: Icahn School of Medicine at Mount Sinai, Jersey Shore University Medical Center

Abstract Preview: Purpose:
Early Eclipse models use rectangular fluence profiles (widened by the dosimetric leaf gap (DLG) to account for the fact that leaf tips are rounded). Eclipse Version 18 (V18) uses enhanced ...

Revealing Unseen Risks: Hands-on Technologist Education to Prevent MRI Incidents Using Ferromagnetic Detecting Wands

Authors: Chris Beasley, Ngara Linda Bird, Flora Ivanova, Erin B. Macdonald, Lauren M. Neldner, Beth Reed, Scott H. Robertson

Affiliation: School of Medicine, Duke University, Duke University, Duke University Health System

Abstract Preview: Purpose: To develop a hands-on, data-driven educational program to improve MRI technologists' understanding and effective use of ferromagnetic detecting (FMD) wands.
Methods: A 30-minute interactiv...

Supercomputing-Enabled CT Virtual Imaging Trials: A Population-Scale Pilot Study

Authors: Ehsan Abadi, Zakaria Aboulbanine, Nicholas D Felice, David Fenwick, Anuj J. Kapadia, Cindy Marie McCabe, Jayasai Ram Rajagopal, Ehsan Samei

Affiliation: Duke University, Oak Ridge National Laboratory, Center for Virtual Imaging Trials, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose:
Virtual imaging trials (VITs) offer a computational alternative to clinical imaging trials leveraging virtual patients, scanners, and interpreters to assess imaging questions. To provide m...

Ultrasonic Detection of Flash-Level Dose Pulses from a Medical Linac

Authors: Fred B. Bateman, Ilaria M. Luna, Ronald E. Tosh

Affiliation: Sidwell Friends School, NIST, Dosimetry Group, Radiation Physics Division, National Institute of Standards and Technology

Abstract Preview: Purpose: To exploit the rapid response time and dose sensitivity of ultrasonic detection methods for resolving pulse structure in FLASH-level beams.

Methods: Two ultrasonic transducers position...

Using a Generative Adversarial Network (GAN) for Source Particle Generation in Monte Carlo Radiation Therapy Simulations

Authors: Jiankui Yuan, Dandan Zheng, Tingliang Zhuang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, University of Rochester, Varian Medical Systems, Advanced Oncology Solutions

Abstract Preview: Purpose: In Monte Carlo (MC) radiation therapy dose calculations, latent variance exists when directly applying phase-space files (PSF) with a finite number of source particles, while the latter is pr...

Utilization of Log File Analysis to Determine Deliverability of VMAT Plans As a Function of Plan Complexity

Authors: Jameson T. Baker, Sean T Grace, Cindy Pham, Michael A. Trager

Affiliation: Northwell

Abstract Preview: Purpose:
In VMAT planning, increasing complexity in MLC motion and modulation may improve dose distributions and OAR sparing while maintaining PTV coverage. However, increasing complexity can creat...

Validation of SRS Mapcheck for Patient-Specific Quality Assurance of Cyberknife

Authors: Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, Tae Ho Kim, Sangmin Lee

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: The CyberKnife system, designed for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT), considers SRS MapCHECK an effective tool for patient-specific QA (PSQA). This wo...