4ฯ€ Non-Coplanar Stereotactic Body Radiation Therapy: Dosimetric Evaluation of VMAT Configurations in for Recurrent Head and Neck Tumors

Authors: Sixue Dong, Weigang Hu, Jiazhou Wang, Zhen Zhang

Affiliation: Fudan University Shanghai Cancer Center

Abstract Preview: Purpose: This study aimed to evaluate the dosimetric benefits and treatment efficiency of different beam configurations in 4ฯ€ non-coplanar VMAT for SBRT in recurrent head and neck tumors

Method...

A Dosimetric Study of Misconnection to Unloaded Needles in Interstitial HDR Brachytherapy

Authors: Shifeng Chen, Mariana Guerrero, Brian A. Hrycushko, Kai Huang, Kai Jiang, Narottam Lamichhane, Paul M. Medin, Elizabeth Nichols

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland Medical Center

Abstract Preview: Purpose: Unloaded needle catheters, if not handled properly, pose a risk for channel misconnection in interstitial high dose rate (iHDR) brachytherapy. This study aims to investigate the dosimetric im...

A Framework for Automated Selection of Dose-Volume Objectives to Improve Radiation-Induced Immune Suppression (RIIS)-Related Overall Survival (OS) Following Chemo-Radiotherapy

Authors: Gabriel Lucas Andrade de Sousa, Einsley-Marie Janowski, Cam Nguyen, Krishni Wijesooriya

Affiliation: Department of Radiation Oncology, University of Virginia, Department of Physics, University of Virginia

Abstract Preview: Purpose: Optimizing radiation therapy (RT) to spare the immune system may improve Overall Survival (OS) in cancer patients. This study develops a computational algorithm to identify optimal dose-volum...

A Method for Forward Planning with the Venezia HDR Applicator

Authors: Timothy J Allen, David A. Sterling

Affiliation: University of Minnesota Physicians, Department of Radiation Oncology, University of Minnesota, Minneapolis

Abstract Preview: Purpose: Treatment planning for the Venezia HDR brachytherapy applicator is often performed using inverse planning tools such as IPSA or HIPO. However, there are planners who are either unfamiliar wit...

A Novel Non-Measured and DVH-Based IMRT QA Framework with Machine Learning for Instant Classification of Susceptible Lung SBRT VMAT Plans

Authors: Chuan He, Anh H. Le, Iris Z. Wang

Affiliation: Roswell Park Comprehensive Cancer Center, Cedars-Sinai

Abstract Preview: Purpose: To develop a non-measured and DVH-based (NMDB) IMRT QA framework integrating machine learning (ML) to classify lung SBRT VMAT plans prone to delivery errors
Methods: 560 Eclipse AcurosXB l...

A Pilot Study to Implement a Definitive Breast SBRT Technique

Authors: Charmainne Cruje, Maria Dumol, Nawroz Fatima, Marisa Finlay, Kalaina Johnson, Raman Mohla, Jasleen Uppal

Affiliation: Trillium Health Partners, Carlo Fidani Regional Cancer Centre

Abstract Preview: Purpose: To evaluate the robustness of a breast SBRT protocol in achieving target coverage by utilizing online- and retrospectively-matched CBCT-to-CT images.
Methods: The first pilot patient was s...

Assessing Low Iodine Concentrations in Liver Lesions with Dual Energy CT: Impact of Beam Choices

Authors: Xinhua Li, Vu Nguyen, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose: Assessing iodine concentration in liver lesions is essential for evaluating contrast enhancement in multi-phase liver CT and for accurate disease diagnosis. This study aims to evaluate the as...

Assessing the Need for Online Adaptive Prostate SBRT Using the MR-Linac

Authors: Awens Alphonse, Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Samuel Richter, Lauren A. Rigsby, Tino Romaguera, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: This study evaluates the necessity and potential benefits of online adaptive stereotactic body radiotherapy (SBRT) for prostate cancer using the ViewRay MR-Linac system. By leveraging real-ti...

BEST IN PHYSICS MULTI-DISCIPLINARY: Evaluation of Spot-Level N-12 PET Imaging for Online Range Verification in Multi-Field Intensity Modulated Proton Therapy

Authors: Zahra Ahmadi Ganjeh, Stefan Both, Peter Dendooven, Jeffrey Free, Brian Zapien Campos

Affiliation: Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Particle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen

Abstract Preview: Purpose: Positron emission tomography (PET) has been investigated for range monitoring in intensity-modulated proton therapy (IMPT), but real-time feedback been limited due to the focus on long-lived ...

Commissioning of a 3D-CRT Planning Software for a Machine with Only Flattening-Filter Free Energy

Authors: Michalis Aristophanous, Steven Blum, Laura I. Cervino, Antonio L. Damato, Karen Episcopia, Chi Huang, Shih-Chi Lin, Michelle K. Savacool

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Varian Ethos (Varian Medical Systems, Palo Alto, CA) is a 6 MV flattening-filter-free (FFF) only machine, posing a challenge in creating homogeneous dose distributions when using manual 3D-CR...

Contingency Planning for Left-Sided Breast Radiation Treatment Using Breath-Hold Technique with Different Delivery Methods

Authors: Nrusingh C. Biswal, Sally Cheston, Sung-Woo Lee, Weiguang Yao, Baoshe Zhang

Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine

Abstract Preview: Purpose: The deep inspiration breath-hold (DIBH) technique in left breast radiation reduces doses to critical organs such as the heart, left lung, and left anterior descending artery (LAD). With the a...

Correlation of Dose Volume Metrics with Skin Systemic Sclerosis 12 Months Post Radiotherapy for Head & Neck Cancer

Authors: Gregory A Azzam, Danielle Cerbon, Laura Huang, Panayiotis Mavroidis, Diana Molinares, Stuart E Samuels, Sotirios Stathakis

Affiliation: Mary Bird Perkins Cancer Center, University of Miami Sylvester Comprehensive Cancer Center, Mount Vernan Rehabilitation Medicine Associates, Department of Radiation Oncology, University of Miami, University of North Carolina

Abstract Preview: Purpose: This study examines the correlation of different dose volume metrics of the skin, sternocleidomastoid (SCM) muscle and subcutaneous tissue (subcut) structures with the skin systemic sclerosis...

Creation of Proton Minibeams in a Pbs Nozzle from Low Emittance Source Beams

Authors: Seung Yeon Kim, Grant A. McAuley, Ju A Park, Jerry D Slater

Affiliation: Loma Linda University

Abstract Preview: Purpose: The production of proton minibeams in standard PBS nozzles is challenging due to the effects of finite source beam divergence and multiple Coulomb scattering. Herein we investigate the use of...

Deep Learning-Based Segmentation Using Cine Epid Images for Real-Time Tumor Monitoring

Authors: Fumiaki Komatsu, Shunsuke Moriya, Ryosuke Nakamura, Takeji Sakae, Toshiyuki Terunuma, Tetsuya Tomita

Affiliation: Graduate School of Comprehensive Human Sciences, University of Tsukuba, Institute of Medicine, University of Tsukuba, Proton Medical Research Center, University of Tsukuba, Department of Radiology, University of Tsukuba Hospital

Abstract Preview: Purpose: To develop a deep learning (DL) model capable of accurately tracking lung tumors independent of beam angle variations.
Methods: A thoracic dynamic phantom simulating lung motion in the sup...

Direct Dose Verification in Liver SBRT Utilizing an Accumulative Daily CBCT Algorithm

Authors: Michael Buckstein, Yang Lei, Tian Liu, Charlotte Elizabeth Read, Jing Wang, Kaida Yang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose: Inter-fraction anatomic variations in liver SBRT can cause significant discrepancies between planned and delivered doses. We developed a CBCT-based accumulative algorithm to directly compare ...

Dosimetric Evaluation of a Helical Tomotherapy to L-Shaped Linac Plan Conversion Workflow

Authors: Megan E. Daly, Ryan D. Hernandez, Abriel J. Horak, Soo Kyoung Kim, Peter C. Park, Dwaine O. Spence, Payton H. Stone, Cari L. Wright

Affiliation: UC Davis Cancer Center

Abstract Preview: Purpose: To evaluate a fallback planning workflow used for cross-modality treatment planning and delivery between helical Tomotherapy and volumetric modulated arc therapy (VMAT) using conventional L-s...

Dosimetric Feasibility of Dominant Intraprostatic Lesion Dose Escalation in HDR Prostate Brachytherapy

Authors: Abby E. Besemer, Carolyn Eckrich, John M. Floberg, Michael J. Lawless, Jessica R. Miller, Joseph B. Schulz, Jordan M. Slagowski, Autumn E. Walter-Denzin

Affiliation: University of Wisconsin-Madison Department of Medical Physics, University of Wisconsin-Madison Department of Human Oncology, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology, Stanford University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: The aim of this treatment planning study was to evaluate the feasibility of escalating dose with HDR prostate brachytherapy to imaging-identified intraprostatic macroscopic lesions while mode...

Dosimetric Impact of Target Coverage with Inter-Fraction Patient Yaw Setup Error in IMRT/VMAT Prostate Cancer Radiotherapy

Authors: Min Su

Affiliation: Mount Sinai School of Medicine

Abstract Preview: Purpose: To evaluate dosimetric impact of patient setup yaw error to target coverage for pelvis/prostate radiation external beam IMRT-VMAT treatment.
Methods: 9 Pelvis/prostate IMRT-VMAT treatment ...

Dosimetric Variations Induced By Inaccurate Collimator Angles in Single-Isocenter SRS Plan for Multi-Lesion Brain Metastases

Authors: Makunda Aryal, Gregory Bartlett, David D. Campos, Ke Colin Huang, Sook Kien Ng, Christopher F. Njeh, Oluwaseyi Oderinde, Edwin Quashie, Ashok Tiwari, Yong Yue

Affiliation: Purdue University, Department of Radiation Oncology, Indiana University, Indiana University, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose:
Linear accelerator-based single-isocenter Stereotactic Radiosurgery (SRS) is widely used for treating brain metastases due to its efficiency, reduced treatment time, and lower imaging dose...

Dosimetry Impact of Overlapping Reconstruction of CT Simulation in Stereotactic Radiosurgery Planning

Authors: Matthew Stephen Andriotty, Chi Ma, Xiao Wang, Keying (Karen) Xu, Suhong Yu, Ning J. Yue, Yin Zhang

Affiliation: Brigham and Women's Hospital, Rutgers Cancer Institute of New Jersey

Abstract Preview: Purpose: To evaluate the effects of overlapping CT reconstruction on dosimetry calculation for LINAC-based SRS patients simulated on CT simulators from three different vendors.
Methods: CT simulati...

Dual-Energy CT Derived Perfusion Blood Volume and 4D-CT Derived Ventilation Changes in Lung Cancer Patients 6-Months Post Radiation Therapy

Authors: Daniel A. Alexander, Jeffrey D. Bradley, Steven J. Feigenberg, Cole Friedes, Casey Hollawell, William Levin, Maksym Sharma, Boon-Keng Kevin Teo, Ying Xiao, Nikhil Yegya-Raman, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology and Applied Sciences, Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: To investigate lung function changes following definitive chemoradiation dose using CT-derived measurements in patients with locally advanced NSCLC at 6-months post-treatment compared to pre-...

End-to-End Pre-Planning Needle Trajectory and Dwell Time Optimization for 3D Printable Cervical and Vaginal Templates

Authors: Deidre Batchelar, Michael Kudla, Stephanie Merkl, Tony Teke

Affiliation: BC Cancer - Kelowna

Abstract Preview: Purpose: Preplanning 3D-printed templates for cervical and vaginal brachytherapy is an iterative process, often taking hours to for an individual patient.
This study demonstrates an end-to-end auto...

FMEA for Optimizing Patient-Specific QA Program in IMRT: Insights from Diverse Practices

Authors: Bing-Hao Chiang, Eric C. Ford, Juergen Meyer, Timothy D. Solberg

Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington

Abstract Preview: Purpose: This study evaluated the potential risk reduction of various pretreatment patient-specific quality assurance (PSQA) programs for Intensity Modulated Radiation Therapy (IMRT) in mitigating fai...

High-Fidelity Treatment Optimization for Online Adaptive Stereotactic Partial Breast Irradiation: Integrating Dose and Treatment Time Considerations

Authors: Drexell Hunter Boggs, Carlos E. Cardenas, Jingwei Duan, Joseph Harms, Joel A. Pogue, Richard A. Popple, Courtney Bosse Stanley, Dennis N. Stanley, Sean Xavier Sullivan, Natalie N. Viscariello

Affiliation: Washington University in St. Louis, The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: CBCT-guided online adaptive radiation therapy (OART) with Ethos for stereotactic accelerated partial breast irradiation (APBI) can mitigate inter-fraction variation, leading to dosimetric adv...

Impac of Respiratory Motion on Dosimetric and Biological Outcomes in Lung Cancer SIB-SBRT: A 4D Dose Calculation Approach

Authors: Xiangli Cui, Lingling Liu

Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Cancer Hospital, Chinese Academy of Sciences

Abstract Preview: Purpose:
Respiratory motion introduces substantial dose uncertainties in lung cancer radiotherapy, particularly affecting dose distribution in Simultaneous Integrated Boost-Stereotactic Body Radiot...

Impact of Mlc and Collimator Errors in Psqa Techniques for VMAT Breast Treatment Plans

Authors: Maria Jose Almada, Oscar Apaza, Carlos Bohorquez, Ezequiel Cabrera, Rogelio Diaz Moreno, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger

Affiliation: LAP, FaMAF, UNC, Instituto Zunino - Fundacion Marie Curie

Abstract Preview: Purpose:
PSQA employs gamma analysis to verify the planned versus delivered dose. Evaluating the effectiveness of PSQA techniques in identifying errors is crucial. This study aims to incorporate ML...

Impact of Patient Setup Errors on the MR Linac-Based SBRT Treatment for Prostate Cancer

Authors: Awens Alphonse, Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: In radiation therapy, patient setup errors have been a primary concern impacting dose delivery accuracy. A robust treatment plan is essential to mitigate these errors. This study aimed to eva...

Initial Comparison of 3D CBCT Performance: New Mobile C-Arm Vs. O-Arm Unit

Authors: Wendy Siman, Wei Zhou

Affiliation: University of Colorado Anschutz Medical Campus, School of Medicine

Abstract Preview: Purpose:
To compare the image quality and radiation dose of 3D cone-beam CT modes of a mobile C-arm and an O-arm unit for intraoperative imaging.
Methods:
A 50-ยตm tungsten wire was imaged at ...

Integrated Catheter Position and Dwell Time Optimization for Focal Dose Escalation in Prostate HDR Brachytherapy

Authors: Bryan Bednarz, John M. Floberg, Joseph B. Schulz, Jordan M. Slagowski

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Radiation Oncology, Stanford University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Catheter placement for high-dose-rate brachytherapy (HDR BT) is clinician dependent and potentially suboptimal for delivering simultaneous integrated boosts to intraprostatic gross tumor volu...

Investigating the Dosimetric Impact of Margin Reduction for Head and Neck Sequential Boost Treatments with Online Adaptive Radiotherapy

Authors: Jimmy Caudell, Eduardo G. Moros, Nour Nasser, Gage H. Redler, George Yang

Affiliation: Moffitt Cancer Center

Abstract Preview: Purpose: Dosimetric evaluation of PTV margin reduction for Head and Neck(H&N) sequential boost plans using the Ethos online adaptive radiotherapy(oART) system to investigate the tradeoff in decreased ...

Knowledge-Based Online Adaptive Proton Stereotactic Ablative Radiotherapy (SABR) for Localized Prostate Cancer Using Gaussian Process Regression

Authors: Hania A. Al-Hallaq, Duncan Henry Bohannon, Chih-Wei Chang, Anees H. Dhabaan, Vishal Dhere, H Scott McGinnis, Pretesh Patel, Sagar Patel, Keyur Shah, Xiaofeng Yang, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Two-fraction proton SABR is an attractive alternative to brachytherapy for localized prostate cancer. However, potential interfractional anatomical changes necessitate online adaptation, espe...

Leveraging Hybrid Quantum Solvers for Eye Plaque Brachytherapy Treatment Planning Optimization

Authors: Xianjin Dai, PhD, Wu Liu, Eric Nguyen, Lei Xing, Lewei Zhao

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose: Recent developments in hybrid quantum solvers, which combine quantum and classical processing, enable greater flexibility to tackle problems outside the limited scope of pure quantum computin...

Lymph Node Dose Is Associated with Immune Suppression and Poor Overall Survival in Locally Advanced Non-Small Cell Lung Cancer (NSCLC)

Authors: Ryan Gentzler, Xin He, James Larner, J.T. Morgan, Cam Nguyen, Wendy Stewart, Krishni Wijesooriya, Grant Williams

Affiliation: Department of Physics, University of Virginia, Department of Radiation Oncology, University of Virginia, Division of Hematology & Oncology, Department of Medicine, University of Virginia

Abstract Preview: Purpose: Some recent studies have shown Overall Survival (OS) of advanced-stage lung cancer patients treated with chemo-radiation therapy (CRT) is correlated with heart dose [1-5], while in other stud...

Matching CT Numbers between a Photon-Counting CT and an Energy-Integrating Detector CT: A Phantom Study

Authors: Afrouz Ataei, Xinhui Duan, Mi-Ae Park, Liqiang Ren

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University

Abstract Preview: Purpose:
Photon-counting CT (PCCT) has become commercially available recently, offering significant potential to enhance patient care. However, it also introduces unique challenges. One such challe...

Monte Carlo Modeling of an Experimental X-Ray Fluorescence Computed Tomography (XFCT) System with a Pixelated CdTe Detector

Authors: Sang Hyun Cho, Sandun Y. Jayarathna, Neerajan Nepal

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: To develop/validate a Monte Carlo (MC) model of an experimental benchtop x-ray fluorescence computed tomography (XFCT) system with a pixelated CdTe detector that can be used for MC simulation...

Moving Away from Measuring Everything - Implementing 3D Recalculation in a Large Networked Radiotherapy Institution to Replace Routine IMRT / VMAT QA

Authors: Eujin Chan, Christopher Colyer, Leon F Dunn, Jonathan Dunning, Michael Grace, Onno Kamst, Alex Livingstone, Thulani Nyathi, Vladimir Sashin, Philip Satory, Hilmar Schachenmayr, Brindha Subramanian, Lindsay J. Tremethick, Luke Webb

Affiliation: GenesisCare

Abstract Preview: Purpose: The purpose of this work is to outline the methodology and results from the implementation of a 3D recalculation software to replace IMRT/VMAT PSQA measurement across a large, networked radio...

PET Guided Radiation Therapy for Large Planning Target Volume Expansions of Small PET-Active Gross Tumor Volumes

Authors: Sarah Dumont, Trevor Ketcherside, An Liu, William T. Watkins, Qiuyun Xu

Affiliation: RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose:
The RefleXion X1 SCINTIX algorithm convolves beam fluence with real-time PET distributions for tracking and plan adaptation, but radiotherapy Planning Target Volumes (PTVs) are often signi...

Photon-Counting CT Versus Dual Energy CT for Liver Fat Volume Fraction Assessment

Authors: Chao Guo, Xinhua Li, Michael F. McNitt-Gray, Di Zhang, Yifang (Jimmy) Zhou

Affiliation: UCLA, David Geffen School of Medicine at UCLA, Cedars-Sinai Medical Center

Abstract Preview: Purpose: The objective was to quantify the liver fat volume fraction (FVF) with virtual monochromatic imaging (VMI) using photon-counting CT (PCCT) and dual energy CT (DECT).
Methods: A custom desi...

Quantitative Forward Modeling of Propagation-Based X-Ray Phase-Contrast Imaging at Clinical Scale

Authors: Giavanna Luisa Jadick, Patrick J La Riviere, Cailey Riggs

Affiliation: University of Chicago

Abstract Preview: Purpose: We explore the accuracy of physics models for propagation-based x-ray phase-contrast imaging (XPCI) with an eye to future clinical implementation, providing a practical assessment of detectio...

Retrospective Postimplant Dosimetry: Comparison of Line and Point Source for 131cs Low Dose Rate Intracranial Implant Brachytherapy

Authors: Tirthraj Adhikari, Timothy J Allen, Abdullah A. Alshreef, Clara Ferreira

Affiliation: Medical School Department of Radiation Oncology University of Minnesota, University of Minnesota, Loma Linda University Medical Center

Abstract Preview: Purpose: GammaTile Brachytherapy with 131Cs is an effective treatment for glioblastomas, offering local control with minimal radiation necrosis. While the line source model is preferred for dose distr...

Robustness Enhancement for VMAT-TBI Planning and Treatment Delivery

Authors: Courtney R. Buckey, Quan Chen, Suzanne J. Chungbin, Edward L. Clouser, Yi Rong, Jun Tan, Jennifer Yan, Xiang Sheng Yan

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose:
To identify planning techniques that consistently result in robust VMAT-TBI plans that allow for larger patient setup errors.
Methods:
Conventional planning method often results in p...

Supercomputing-Enabled CT Virtual Imaging Trials: A Population-Scale Pilot Study

Authors: Ehsan Abadi, Zakaria Aboulbanine, Nicholas D Felice, David Fenwick, Anuj J. Kapadia, Cindy Marie McCabe, Jayasai Ram Rajagopal, Ehsan Samei

Affiliation: Duke University, Oak Ridge National Laboratory, Center for Virtual Imaging Trials, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose:
Virtual imaging trials (VITs) offer a computational alternative to clinical imaging trials leveraging virtual patients, scanners, and interpreters to assess imaging questions. To provide m...

Target Region-Specific Dose-Volume Parameters for Estimate of Brain Toxicity in Single-Isocenter Multiple-Metastases Linac-Based Stereotactic Radiosurgery

Authors: David L. Barbee, Jose R. Teruel Antolin, Jinyu Xue

Affiliation: NYU Langone Health

Abstract Preview: Purpose: This work introduces a method of regional dose evaluation of normal brain tissue using local target-specific evaluation and compares to global dose evaluation for linac-based single-isocenter...

Ultrafast Proton Delivery with Pin Ridge Filters (pRFs): A Novel Approach for Motion Management in Proton Therapy

Authors: Zachary Diamond, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Active breath-hold techniques effectively mitigate respiratory motion but poses challenges for patients who are unable to tolerate the procedure. Conventional planning relies on multiple ener...

Water-Equivalent Thickness Mapping (WET-MAP) โ€“ a Potential Alternative to 4D Robust Optimization for Motion Management in Proton Treatment Planning

Authors: Duncan Henry Bohannon, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, Ahmal Jawad Zafar, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose:
4D robust optimization, incorporating additional images (e.g., maximum inhale/exhale phases), is commonly used to account for target motion in proton treatment planning. However, the incre...