Search Submissions 🔎

Results for "v40 v50": 95 found

4π Non-Coplanar Stereotactic Body Radiation Therapy: Dosimetric Evaluation of VMAT Configurations in for Recurrent Head and Neck Tumors

Authors: Sixue Dong, Weigang Hu, Jiazhou Wang, Zhen Zhang

Affiliation: Fudan University Shanghai Cancer Center

Abstract Preview: Purpose: This study aimed to evaluate the dosimetric benefits and treatment efficiency of different beam configurations in 4π non-coplanar VMAT for SBRT in recurrent head and neck tumors

Method...

A Dosimetric Study of Misconnection to Unloaded Needles in Interstitial HDR Brachytherapy

Authors: Shifeng Chen, Mariana Guerrero, Brian A. Hrycushko, Kai Huang, Kai Jiang, Narottam Lamichhane, Paul M. Medin, Elizabeth Nichols

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland Medical Center

Abstract Preview: Purpose: Unloaded needle catheters, if not handled properly, pose a risk for channel misconnection in interstitial high dose rate (iHDR) brachytherapy. This study aims to investigate the dosimetric im...

A Dosimetric Study of Small-Field Apertured Spot-Scanning Proton Stereotactic Radiosurgery for Pediatric Brain Tumors

Authors: Chin-Cheng Chen, Chia-Ho Hua, Christopher J. Kutyreff, Thomas E. Merchant

Affiliation: St. Jude Children's Research Hospital

Abstract Preview: Purpose: A dosimetric study was conducted to determine the optimal field parameters for a commercially available small-field applicator (SFA) used in spot-scanning proton stereotactic radiosurgery, pa...

A Framework for Automated Selection of Dose-Volume Objectives to Improve Radiation-Induced Immune Suppression (RIIS)-Related Overall Survival (OS) Following Chemo-Radiotherapy

Authors: Gabriel Lucas Andrade de Sousa, Einsley-Marie Janowski, Cam Nguyen, Krishni Wijesooriya

Affiliation: Department of Radiation Oncology, University of Virginia, Department of Physics, University of Virginia

Abstract Preview: Purpose: Optimizing radiation therapy (RT) to spare the immune system may improve Overall Survival (OS) in cancer patients. This study develops a computational algorithm to identify optimal dose-volum...

A Method for Forward Planning with the Venezia HDR Applicator

Authors: Timothy J Allen, David A. Sterling

Affiliation: University of Minnesota Physicians, Department of Radiation Oncology, University of Minnesota, Minneapolis

Abstract Preview: Purpose: Treatment planning for the Venezia HDR brachytherapy applicator is often performed using inverse planning tools such as IPSA or HIPO. However, there are planners who are either unfamiliar wit...

A Novel Sphere Packing Solution Via Principal Component Analysis for Lattice SFRT Treatment of Large, Bulky, and Unresectable Tumors

Authors: James Robert Castle, Joshua Misa, Damodar Pokhrel, William St. Clair

Affiliation: University of Kentucky, Department of Radiation Medicine

Abstract Preview: Purpose: We propose a novel methodology for lattice deployment in spatially fractionated radiotherapy (SFRT), using principal component analysis (PCA) to improve sphere packing within the tumor. Impro...

A Quantitative Analysis of Hypersight CBCT Image Quality Using a Phantom-Based Approach Under Different Scatter Conditions

Authors: Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Fang Li, Noor Mail, Joseph Shields, Christopher Tyerech

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, University of Pennsylvania, UPMC

Abstract Preview: Purpose: HyperSight is a new platform for image-guided radiation therapy, offering advanced reconstruction algorithms, a large field-of-view, and rapid acquisition times. To validate the performance o...

A Radiomics and Dosomics-Based Approach for Predicting Hematologic Toxicity in Patients with Cervical or Endometrial Cancer

Authors: Yongrui Bai, Xuming Chen, Yong Liu, Xiumei Ma

Affiliation: Department of Radiation Oncology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China, Department of Radiation Oncology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China

Abstract Preview: Purpose: Hematologic toxicity (HT) is a common complication in patients with cervical or endometrial cancer. This study aims to develop a precise predictive model for acute HT in patients with cervica...

Advocating for Survival Prediction Models in Risk Stratification for Cancer Treatment Outcomes

Authors: Meixu Chen, Jing Wang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center

Abstract Preview: Purpose: Cancer treatment outcome prediction plays a pivotal role in guiding therapeutic decisions and optimizing patient care. Traditionally, binary prediction models have been widely used for risk s...

Assessing Low Iodine Concentrations in Liver Lesions with Dual Energy CT: Impact of Beam Choices

Authors: Xinhua Li, Vu Nguyen, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose: Assessing iodine concentration in liver lesions is essential for evaluating contrast enhancement in multi-phase liver CT and for accurate disease diagnosis. This study aims to evaluate the as...

Assessing the Potential of Virtual Grid Portable Radiographic Systems for Radiation Dose Reduction: A Comparative Evaluation of Deviation Index in Abdominal Imaging

Authors: Gary Y. Ge, Azmul Siddique, Jie Zhang

Affiliation: Department of Radiology, University of Kentucky, University of Kentucky

Abstract Preview: Purpose: Virtual grid technology addresses scattered radiation without a physical grid, offering the potential to reduce patient radiation dose while maintaining image quality. However, this potential...

Attention-Based Multiple Instance Learning of Head and Neck Cancer Grading on Digital Pathology Using Vision-Language Foundational Models

Authors: Kyle J. Lafata, Xiang Li, Megan K. Russ, Zion Sheng

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: To adapt Vision-Language Foundational Models (VLFM) to perform HNSCC tumor grading on H&E whole slide images (WSI) via attention-based multiple instance learning (ABMIL).
Methods: We utili...

Automated MR Segmentation for Online Adaptive MR-Linac Therapy Using an in-House Model

Authors: David L. Barbee, David Byun, Matt Long, Jose R. Teruel Antolin, Michael J Zelefsky

Affiliation: NYU Langone Health

Abstract Preview: Purpose:
Online adaptive MR-Linac therapy requires contour adaptation, often adding 20 minutes to treatment time and reducing machine throughput. This study introduces a fully automated MR contour ...

BEST IN PHYSICS IMAGING: Volumetric Sampling Properties of Longitudinal Multiple X-Ray-Source Array Computed Tomography (MXA-CT)

Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski, Huanyi Zhou

Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation

Abstract Preview: Purpose: A new CT configuration utilizing a multiple X-ray-source array (MXA) is under development to mitigate cone-beam (CB) artifacts in single-rotation wide coverage imaging. We investigate the sam...

BEST IN PHYSICS MULTI-DISCIPLINARY: Foundation Model-Empowered Unsupervised 3D Deformable Medical Image Registration

Authors: Xianjin Dai, PhD, Zhuoran Jiang, Lei Ren, Lei Xing, Zhendong Zhang

Affiliation: University of Maryland School of Medicine, Department of Radiation Oncology, Stanford University, Duke University, Stanford University

Abstract Preview: Purpose: Unsupervised deep learning has shown great promise in deformable image registration (DIR). These methods update model weights to optimize image similarity without necessitating ground truth d...

BEST IN PHYSICS RADIOPHARMACEUTICALS, THERANOSTICS AND NUCLEAR MEDICINE: Characterization and Dose Rate Calibration of a Semiconductor-Based Radiation Imaging Survey Meter

Authors: Steven Brown, Mike Hopkins, Jerimy C. Polf, Scott Sawyer, Benjamin L. Viglianti

Affiliation: H3D, inc, University of Michigan, M3D, Inc, M3D Imaging

Abstract Preview: Purpose: We characterized the sensitivity, energy dependence, and calibrated dose rate for a radiation imaging survey meter (RAVIN Cam; M3d inc., Ann Arbor MI) based on cadmium zinc telluride (CZT) cr...

Beam Orientation Optimization in IMRT Using Sparse Mixed Integer Programming and Non-Convex IMRT Fluence Map Optimization

Authors: Yabo Fu, Yang Lei, Yu Lei, Haibo Lin, Ruirui Liu, Tian Liu, Kenneth Rosenzweig, Charles B. Simone, Shouyi Wei, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai, University of Nebraska Medical Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York Proton Center

Abstract Preview: Purpose: Beam orientation optimization (BOO) in intensity-modulated radiation therapy (IMRT) is traditionally a complex, non-convex problem tackled with heuristic methods. This study benchmarks global...

Benchmarking Patient Doses for Barium Fluoroscopy Procedures: A Single-Institution Study

Authors: Wilfred R Furtado, Gary Y. Ge, Jie Zhang

Affiliation: Department of Radiology, University of Kentucky, University of Kentucky

Abstract Preview: Purpose: The United Kingdom and several other countries already have well-established diagnostic reference levels (DRLs) for gastrointestinal fluoroscopic procedures, whereas the United States does no...

Binary Classification of Lymphedema in 3DCRT Patients Using Machine Learning on 3D Dose Distribution Data

Authors: Jee Suk Chang, Hojin Kim, Jin Sung Kim, Jaehyun Seok

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Integrative Medicine

Abstract Preview: Purpose: This study aims to leverage 3D dose distribution data to develop a machine learning model capable of accurately predicting lymphedema occurrence in patients undergoing 3D conformal radiation ...

Characterization of HCC Tumor Response in 90Y-Radioembolization Clinical Trial RAPY90D Using Prospective Voxel Dosimetry

Authors: E Courtney Henry, Srinivas Cheenu Kappadath, Armeen Mahvash

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Characterization of hepatocellular carcinoma (HCC) tumor responses for single-arm single-center prospective 90Y-radioembolization clinical trial (n=40) that used patient-specific voxel-dos...

Comparative Analysis of Soft Tissues and 3D Printing Materials Using Euclidean Distance for Linear Attenuation Coefficient

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Elsa Bifano Pimenta

Affiliation: University of SĂŁo Paulo (USP), Institute of Physics

Abstract Preview: Purpose: This study evaluates the similarity between the linear attenuation coefficients of soft tissues and 3D printing materials in diagnostic imaging range using the Euclidean distance approach.

Contingency Planning for Left-Sided Breast Radiation Treatment Using Breath-Hold Technique with Different Delivery Methods

Authors: Nrusingh C. Biswal, Sally Cheston, Sung-Woo Lee, Weiguang Yao, Baoshe Zhang

Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine

Abstract Preview: Purpose: The deep inspiration breath-hold (DIBH) technique in left breast radiation reduces doses to critical organs such as the heart, left lung, and left anterior descending artery (LAD). With the a...

Correlation of Dose Volume Metrics with Skin Systemic Sclerosis 12 Months Post Radiotherapy for Head & Neck Cancer

Authors: Gregory A Azzam, Danielle Cerbon, Laura Huang, Panayiotis Mavroidis, Diana Molinares, Stuart E Samuels, Sotirios Stathakis

Affiliation: Mary Bird Perkins Cancer Center, University of Miami Sylvester Comprehensive Cancer Center, Mount Vernan Rehabilitation Medicine Associates, Department of Radiation Oncology, University of Miami, University of North Carolina

Abstract Preview: Purpose: This study examines the correlation of different dose volume metrics of the skin, sternocleidomastoid (SCM) muscle and subcutaneous tissue (subcut) structures with the skin systemic sclerosis...

Deep-Learning Based Spectral Artifact Removal with In Vivo 7T Proton MRSI Data

Authors: Anke Henning, Mahrshi Jani, Tianyu Wang, Andrew Wright, Xinyu Zhang

Affiliation: Advanced Imaging Research Center (AIRC), UT Southwestern Medical Center

Abstract Preview: Purpose: Proton MRSI offers critical metabolic insights into diseased brain processes but is prone to artifacts, and current post-processing methods are often insufficient, resulting in low-quality da...

Development and Validation of a Principal Component Analysis Statistical Shape Pediatric/Adolescent Breast Model for Pre-CT Era Breast Dose Reconstruction in Late Effect Studies of Female Childhood Cancer Survivors

Authors: Gregory T. Armstrong, James E. Bates, Kristy K. Brock, Laurence Edward Court, Matt Ehrhardt, Danielle Friedman, Aashish C. Gupta, Donald Hancock, Rebecca M. Howell, Cindy Im, Tera S Jones, Choonsik Lee, Wendy Leisenring, Taylor Meyers, Lindsay Morton, Chaya Moskowitz, Joe Neglia, Vikki Nolan, Caleb O'Connor, Kevin C. Oeffinger, Constance A. Owens, Arnold C. Paulino, Chelsea C. Pinnix, Sander Roberti, Cecile Ronckers, Susan A. Smith, Kumar Srivastava, Lucie Turcotte

Affiliation: Department of Medicine, Duke University School of Medicine, Department of Epidemiology and Cancer Control, St. Jude Children’s Research Hospital, The University of Texas MD Anderson Cancer Center, Department of Oncology, St. Jude Children’s Research Hospital, Department of Pediatrics, Memorial Sloan Kettering Cancer Center, Division of Pediatric Epidemiology and Clinical Research, University of Minnesota, Division of Childhood Cancer Epidemiology, University Medicine at Johannes Gutenberg University Mainz, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Pediatrics, University of Minnesota, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Department of Biostatistics, St. Jude Children’s Research Hospital, Clinical Research Division, Fred Hutchinson Cancer Center, Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Department of Epidemiology and Biostatistics, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University, The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences

Abstract Preview: Purpose: To (1) develop and validate a novel anatomically realistic pediatric/adolescent population-based breast model, (2) incorporate model into an age-scalable female reference phantom, and (3) dem...

Development of a Novel Deformable Pelvis Phantom to Support Upright Applications

Authors: Adam P. Berdusco, Matthew R. Ceelen, Renata Farrell, Carri K. Glide-Hurst, Will Martin, Charles F. Maysack-Landry, Morgan A. McGauley, James Rice, Jordan M. Slagowski, Yuhao Yan

Affiliation: Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Upright radiotherapy (RT) is now available although this novel vertical CT and positioner presents unique challenges for quality assurance and testing methodologies. We have designed and buil...

Differential Hole-Size Lattice Patterns for Escalating SFRT Dose to Large, Deep-Seated, and Unresectable Masses

Authors: Joshua Misa, Damodar Pokhrel, William St. Clair

Affiliation: University of Kentucky, Department of Radiation Medicine

Abstract Preview: Purpose: Development of a novel spatially fractionated radiotherapy (SFRT) lattice deployment method featuring a large high-dose sphere at the tumor’s center, surrounded by smaller diameter spheres. W...

Diffusion-Weighted MRI: An Early Biomarker for Treatment Response in MR-Guided Treatment of Rectal Cancer

Authors: Huiming Dong, Jonathan Pham, X. Sharon Qi, Ann Raldow

Affiliation: Department of Radiation Oncology, University of California, Los Angeles

Abstract Preview: Purpose: The study aimed to investigate longitudinal apparent diffusion coefficient (ADC) as an early biomarker of treatment response in patients with locally advanced rectal cancer (LARC) undergoing ...

Dosimetric Effect of Patient Positioning Errors in Dual-Isocenter VMAT for Bilateral Breast Cancer Treatment: A Quantitative Assessment

Authors: Awens Alphonse, Nebi Demez, Noufal Manthala Padannayil, Haley Park, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Nishan Shrestha, Somol Sunny

Affiliation: Florida Atlantic University, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: This study evaluates the dosimetric effects of patient positioning errors, including setup inaccuracies and yaw deviations, on dual-isocenter volumetric modulated arc therapy (VMAT) plans for...

Dosimetric Evaluation of Radiation Treatment Planning Algorithms in IMRT and VMAT Techniques: Analysis with Central and Peripheral Lung Tumors

Authors: Sumanta Manna, Atul Mishra, Surendra Prasad Mishra, Kailash Kumar Mittal, Anoop Kumar Srivastava, Neha Yadav

Affiliation: Department of Radiation Oncology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Department of radiation Oncology, Apollomedics Super Speciality Hospitals, Department of Radiation Oncology, Uttar Pradesh University of Medical Sciences, Department of Radiation Oncology, Kalyan Singh Super Specialty Cancer Institute

Abstract Preview: Purpose: This study aimed to assess the dosimetric performance of Volumetric Modulated Arc Therapy (VMAT), step-and-shoot Intensity-Modulated Radiation Therapy (ss-IMRT), and dynamic Intensity-Modulat...

Dosimetric Evaluation of a Three-Dimensional Cubic Electronic Detector Array for Radiotherapy Linac Quality Assurance

Authors: Enzo Charles Aucca, Roger Challco, Andres M. Gonzales Galvez, Carmen SANDRA Guzman Calcina, Jimmy Hernandez-Bello, Modesto Montoya, Renzo Aaron Ocampo, Erick Paniagua, Miguel Alberto Risco-Castillo, Dante E. Roa, Renzo E. Romero, William Souza Santos, Mirko SalomĂłn Alva SĂĄnchez

Affiliation: Graduate Program in Information Technologies and Health Management, University of Porto AlegreFederal University of Health Sciences of Porto Alegre, Universidad Tecnologica del Peru, Pontificia Universidad Catolica del Peru, Electronic Engineering Department, Leonard Cancer Institute - Radiation Oncology, Universidad Nacional de Ingenieria, Universidad Nacional de Ingenieria, Electronic Engineering Department, Federal University of Sergipe, HRS Oncology International, Universidad Nacional Federico Villareal

Abstract Preview: Purpose: Provide Monte Carlo (MC) and experimental dosimetric assessments of a 3D cubic electronic detector array based on percent depth doses (PDDs), profiles, linearity, and dose rate response of ph...

Dosimetric Feasibility of Dominant Intraprostatic Lesion Dose Escalation in HDR Prostate Brachytherapy

Authors: Abby E. Besemer, Carolyn Eckrich, John M. Floberg, Michael J. Lawless, Jessica R. Miller, Joseph B. Schulz, Jordan M. Slagowski, Autumn E. Walter-Denzin

Affiliation: University of Wisconsin-Madison Department of Medical Physics, University of Wisconsin-Madison Department of Human Oncology, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology, Stanford University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: The aim of this treatment planning study was to evaluate the feasibility of escalating dose with HDR prostate brachytherapy to imaging-identified intraprostatic macroscopic lesions while mode...

Dosimetric Impact of Catheter Length Changes in HDR Brachytherapy for Accelerated Partial Breast Irradiation

Authors: Dylan Richeson, Dorin A. Todor

Affiliation: Inova Schar Cancer Institute, Virginia Commonwealth University

Abstract Preview: Purpose: High dose-rate (HDR) brachytherapy is prone to errors that can lead to incorrect dose delivery and potential medical events. One common issue is applicator length discrepancies, either due to...

Dosimetry Comparison of Surface-Guided and Orthogonal X-Ray Film-Based Setups for Proton Pencil-Beam Scanning in Breast Cancer Treatment

Authors: Darren Kaplan, Chenguang Liu, Mark Pankuch

Affiliation: Northwestern Medicine Proton Center

Abstract Preview: Purpose: This study evaluates the hypothesis that surface-guided radiation therapy for the breast or chest wall using proton PBS provides comparable target coverage and OARs sparing to x-ray-based IGR...

Dual-Energy CT Derived Perfusion Blood Volume and 4D-CT Derived Ventilation Changes in Lung Cancer Patients 6-Months Post Radiation Therapy

Authors: Daniel A. Alexander, Jeffrey D. Bradley, Steven J. Feigenberg, Cole Friedes, Casey Hollawell, William Levin, Maksym Sharma, Boon-Keng Kevin Teo, Ying Xiao, Nikhil Yegya-Raman, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology and Applied Sciences, Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: To investigate lung function changes following definitive chemoradiation dose using CT-derived measurements in patients with locally advanced NSCLC at 6-months post-treatment compared to pre-...

Eclipse AFI Manual Planning Versus Brainlab Auto-Planning: A Comparison of SRS Plan Quality

Authors: Dharmin D. Desai, Ellis Lee Johnson, Philip J. Kallenberg, Kapil M. Mishra

Affiliation: Spectrum Medical Physics, University of Kentucky, Varian Advanced Oncology Solutions

Abstract Preview: Purpose: The “Ask For It” (AFI) manual optimization strategy has been shown to generate high quality SRS plans within Eclipse. The purpose of this work is to directly compare manually generated Eclips...

Effects of Enhanced Leaf Modeling on Single-Isocenter Multi-Target Stereotactic Radiosurgery Dose Accuracy

Authors: Thomas R. Mazur, Kevin Renick, Matthew C. Schmidt, Xiaodong Neo Zhao

Affiliation: Washington University in St. Louis School of Medicine, Washington University School of Medicine

Abstract Preview: Purpose: To compare dose calculation accuracy for single-isocenter multi-target stereotactic radiosurgery plans (SIMT-SRS) in Eclipse V18.0 with enhanced leaf model (ELM) using the anisotropic analyti...

Enhancing Dosimetric Conformity in Single-Energy Bragg Peak Flash Therapy Using Aperture-Based Techniqu

Authors: Chin-Cheng Chen, Chingyun Cheng, Longfei Diao, Benjamin Durkee, Minglei Kang, Haibo Lin, LeLe Liu, Yangguang Ma, Xuanqin Mou, YunTong Pei, Charles B. Simone, YuFei Wang, Xueqing Yan, Xingyi Zhao, Wang Zhengda

Affiliation: Peking University, St. Jude Children's Research Hospital, New York Proton Center, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology, The First Affiliated Hospital of Zhengzhou University, School of Software Engineering, Xi’an Jiaotong University, School of information and communications engineering, Faculty of electronic and information engineering, Xi’an Jiaotong University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: This study evaluates the effectiveness of apertures in improving lateral dose falloff in proton pencil beam scanning (PBS) single-energy Bragg peak (SEBP) FLASH radiotherapy (RT). The approac...

Evaluating a Novel Solution for GYN Planning: Integrated Dynamic Collimator Rotation and Static Angle Modulated Ports with a New Optimizer

Authors: Ben Archibald-Heeren, Grace Gwe-Ya Kim, Kelly Kisling, Xenia Ray

Affiliation: UC San Diego, Icon Cancer Centres, University of California, San Diego, University of California San Diego

Abstract Preview: Purpose: To evaluate improvements in external beam plans for gynecological cancers from a novel planning solution: RapidArc Dynamic (RAD) (Varian Medical Systems, Palo Alto, CA) which optimizes VMAT w...

Evaluation of Cherenkov Imaging for Dose Verification in Total Skin Electron Therapy

Authors: Petr Bruza, David J. Gladstone, Lesley A Jarvis, Natasha Mulenga, Kevin J. Willy

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center

Abstract Preview: Purpose: The goal of this work was to use Cherenkov emission imaging to verify patient position, accessory block positioning and dose delivery in Total Skin Electron Therapy (TSET).

Methods: A ...

Evaluation of Concomitant Imaging Dose in 4D-CBCT Guided Thoracic Radiotherapy

Authors: Yuchao Hu, Yajun Jia, Zhangmin Li, Yong Sang, Jianan Wu, Man Zhao

Affiliation: Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Guangzhou Concord Cancer Hospital, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: To evaluate the imaging dose of 4D-CBCT in patients treated with thoracic radiotherapy.
Methods: A model of the Elekta XVI imaging system was created in TOPAS software. Percentage depth do...

Evaluation of Hypersight CBCT Scanning Techniques for Motion Management in Online Adaptive Radiotherapy: A Comparative Study of Slow, Fast, and Averaged Scans

Authors: Fan Liu, Adam C. Riegel, Yi-Fang Wang

Affiliation: Columbia University Irving Medical Center

Abstract Preview: Purpose: HyperSight, Varian Medical Systems' latest CBCT technology, integrates rapid 6-second data acquisition with advanced iterative reconstruction, enabling precise real-time contouring and dose c...

Feasibility Study of Ethos Artificial-Intelligence Online Adaptive Prostate SBRT

Authors: Miguel Albaladejo, Ana Corbalan, Aitor Ortega, Vicente Puchades, David Ramos, Alfredo Serna-Berna, Jonattan Suarez

Affiliation: Hospital General Universitario Santa Lucia

Abstract Preview: Purpose:
Prostate SBRT treatments are frequently delivered using standard VMAT IGRT technique. The aim of this study is to test the feasibility of Ethos Artificial Intelligence (AI) prostate SBRT b...

Finding the Best Match of 4D-CT Phases to Delineate Volumes for Bgrt

Authors: Resat Aydin, Joseph Barbiere, Brett Lewis, Roland Teboh

Affiliation: HUMC, Hackensack University Medical Center

Abstract Preview: Purpose:
Accurately compensating for respiratory-induced tumor motion is critical in BgRT, where precise delineation of volumes ensures effective dose delivery. We propose an integrated approach th...

Free-Breathing Spirometer-Gated Proton Pencil Beam Scanning Delivery Maintains Tumor Coverage with Improved Organ-at-Risk Sparing: A Motion Phantom Validation

Authors: Uriel Aura, Qing Chen, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Meng Wei Ho, Sheng Huang, Minglei Kang, Stanislav Lazarev, Nancy Y Lee, Yang Lei, Haibo Lin, Hang Qi, Mahbubur Rahman, Charles B. Simone, Shouyi Wei, Irini Yacoub, Francis Yu, Anna Zhai, Ajay Zheng

Affiliation: DYN'R Medical System, New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Tianjin Medical University Cancer Institute&Hospital, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Managing tumor motion during pencil beam scanning proton therapy remains challenging. This study investigated the feasibility and dosimetric benefits of Free-Breathing Respiratory-Gated Deliv...

Geometric Alignment of MV-CBCT and Dual-Layer Kv-CBCT Projections Using Deep Learning

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Applications of combined kV-MV CBCT include metal artifact correction and material identification. Difficulties arise, however, when the imagers have misaligned geometric perspectives of the ...

Gradient-Based Radiomics for Outcome Prediction and Decision-Making in Personalized Ultra-Fractionated Stereotactic Adaptive Radiotherapy (PULSAR): A Preliminary Study

Authors: Michael Dohopolski, Jiaqi Liu, Hao Peng, Robert Timmerman, Zabi Wardak, Haozhao Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
This study introduces a gradient-based radiomics framework to enhance outcome prediction in Personalized Ultra-Fractionated Stereotactic Adaptive Radiotherapy (PULSAR) for brain metastases...

High-Energy Current Detectors for Proton Dose-Rate Beam Monitoring at Flash Dose-Rates.

Authors: Davide Brivio, Lia Carroll, Juliane Daartz, Jan PO Schuemann, Piotr Zygmanski

Affiliation: Massachusetts General Hospital, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: We employ High-Energy Current (HEC) detectors for real-time monitoring of proton beams at conventional to FLASH dose rates. This would help overcome the need for fast and accurate dosimeters ...

High-Fidelity Treatment Optimization for Online Adaptive Stereotactic Partial Breast Irradiation: Integrating Dose and Treatment Time Considerations

Authors: Drexell Hunter Boggs, Carlos E. Cardenas, Jingwei Duan, Joseph Harms, Joel A. Pogue, Richard A. Popple, Courtney Bosse Stanley, Dennis N. Stanley, Sean Xavier Sullivan, Natalie N. Viscariello

Affiliation: Washington University in St. Louis, The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: CBCT-guided online adaptive radiation therapy (OART) with Ethos for stereotactic accelerated partial breast irradiation (APBI) can mitigate inter-fraction variation, leading to dosimetric adv...

Image Quality Improvement Using a Patient-Specific Post-Trigger Delay Protocol for Coronary CT Angiography

Authors: Cecelia Brewington, Connor Edwards Miles All Leska-Kent, Kyrillos Grace, Katherine Hyde, Sabee Molloi, Shiva Mostafavi, Liqiang Ren, Alireza Shojazadeh, Justin Truong

Affiliation: Department of Radiology, UT Southwestern Medical Center, University of California, Irvine, University of Texas Southwestern

Abstract Preview: Purpose: To retrospectively assess image quality in coronary CT angiography (CCTA) using a patient-specific post-trigger delay (PTD) protocol, developed using half of the injection time plus a dispers...

Implementing a Learning-to-Optimize Machine Learning Framework to Accelerate VMAT Treatment Planning Optimization for Prostate Cancer

Authors: Ara Alexandrian, Sadiki Daniel

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: To develop a learning-to-optimize machine learning model that accelerates optimization in VMAT treatment planning by training on prostate patient data.
Methods: A treatment plan dataset of...

Improving Patient Safety with MRI Visible Laterality Markers

Authors: Ndey Badjan, Chris Beasley, Issack Boru, Josh Joyner, Erica Owenby, Scott H. Robertson, Nicholas Said

Affiliation: Duke University Health System

Abstract Preview: Purpose:
To design MRI-visible laterality markers to boost patient safety by minimizing errors in laterality and subsequent procedures.
Methods:
The markers were made using commercially avail...

Initial Comparison of 3D CBCT Performance: New Mobile C-Arm Vs. O-Arm Unit

Authors: Wendy Siman, Wei Zhou

Affiliation: University of Colorado Anschutz Medical Campus, School of Medicine

Abstract Preview: Purpose:
To compare the image quality and radiation dose of 3D cone-beam CT modes of a mobile C-arm and an O-arm unit for intraoperative imaging.
Methods:
A 50-Âľm tungsten wire was imaged at ...

Innovative Design and Simulation of a Pediatric-Dedicated SPECT: Enhancing Imaging Performance for a Healthier Scans in Children

Authors: Mohammadreza Ay, Nahal Daneshgar, Nima Kasraie, Abbas Monsef, Zeinab Peymani, Hadi Rezaei, Peyman Sheikhzadeh

Affiliation: University of Minnesota Medical School, Radiation Oncology, Department of Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences, Shiraz University of Medical Sciences, Department of Medical Physics, Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, UT Southwestern Medical Center, Imam Khomeini Hospital Complex,Tehran University of Medical Sciences

Abstract Preview: Purpose:
This study aims to design and simulate an innovative pediatric-dedicated SPECT scanner optimized for children’s unique anatomical and safety needs by enhancing sensitivity in data acquisit...

Integrated Catheter Position and Dwell Time Optimization for Focal Dose Escalation in Prostate HDR Brachytherapy

Authors: Bryan Bednarz, John M. Floberg, Joseph B. Schulz, Jordan M. Slagowski

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Radiation Oncology, Stanford University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Catheter placement for high-dose-rate brachytherapy (HDR BT) is clinician dependent and potentially suboptimal for delivering simultaneous integrated boosts to intraprostatic gross tumor volu...

Investigation into the Robustness of Spine Stereotactic Body Radiotherapy Plans to Patient Setup Errors

Authors: Yukio Fujita, Syoma Ide, Fumiki Ito, Kei Ito, Satoshi Kito, Keiko Murofushi, Yujiro Nakajima, Yuhi Suda, Kentaro Taguchi, Naoki Tohyama, Fumiya Tsurumaki, Riku Watanabe

Affiliation: Komazawa University Graduate School, Komazawa University, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital

Abstract Preview: Purpose: Spine stereotactic body radiotherapy (SBRT) demands high precision due to the target's proximity to the spinal cord and steep dose gradients, which complicate treatment planning. Consequently...

Knowledge-Based Online Adaptive Proton Stereotactic Ablative Radiotherapy (SABR) for Localized Prostate Cancer Using Gaussian Process Regression

Authors: Hania A. Al-Hallaq, Duncan Henry Bohannon, Chih-Wei Chang, Anees H. Dhabaan, Vishal Dhere, H Scott McGinnis, Pretesh Patel, Sagar Patel, Keyur Shah, Xiaofeng Yang, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Two-fraction proton SABR is an attractive alternative to brachytherapy for localized prostate cancer. However, potential interfractional anatomical changes necessitate online adaptation, espe...

Lung-Equivalent Compressible Material As Core Component for a Miniaturized Breathing Phantom Prototype

Authors: Silvia Calusi, Lucia Cavigli, Alberto Dalla Mora, Laura Di Sieno, Giacomo Insero, Riccardo Lisci, Livia Marrazzo, Cosimo Nardi, Stefania Pallotta, Andrea Profili, Fulvio Ratto, Giovanni Romano, Michaela Servi, Immacolata Vanore, Yary Volpe

Affiliation: Italian National Research Council IFAC-CNR, Institute of Applied Physics, Department of Physics, Politecnico di Milano, Department of Agricultural Food and Forestry System, University of Florence, Medical Physics Unit, Azienda Ospedaliero-Universitaria Careggi, Department of Industrial Engineering, University of Florence, Department of Experimental and Clinical Biomedical Sciences “Mario Serio”, University of Florence

Abstract Preview: Purpose: To develop a multi-purpose lung phantom prototype to replicate respiratory dynamics and morphological features observed in clinical radiological (CT and MR) imaging of lung parenchyma.
Met...

Lymph Node Dose Is Associated with Immune Suppression and Poor Overall Survival in Locally Advanced Non-Small Cell Lung Cancer (NSCLC)

Authors: Ryan Gentzler, Xin He, James Larner, J.T. Morgan, Cam Nguyen, Wendy Stewart, Krishni Wijesooriya, Grant Williams

Affiliation: Department of Physics, University of Virginia, Department of Radiation Oncology, University of Virginia, Division of Hematology & Oncology, Department of Medicine, University of Virginia

Abstract Preview: Purpose: Some recent studies have shown Overall Survival (OS) of advanced-stage lung cancer patients treated with chemo-radiation therapy (CRT) is correlated with heart dose [1-5], while in other stud...

Machine Learning Knowledge Based Planning Model for Hypo Fractionated Prostate/Prostate Lymph Nodes Treatments

Authors: Nina Burbure, Tawfik G. Giaddui, Shidong Li, Curtis Miyamoto, Jeremy Price, Bin Wang

Affiliation: FCCC at Temple University Hospital

Abstract Preview: Purpose: To evaluate the performance of KBP models for hypo-fractionated prostate and pelvic lymph nodes (LN) VMAT plans.
Methods: A KBP model (TUH KBP) was developed in Eclipse treatment planning ...

Matching CT Numbers between a Photon-Counting CT and an Energy-Integrating Detector CT: A Phantom Study

Authors: Afrouz Ataei, Xinhui Duan, Mi-Ae Park, Liqiang Ren

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University

Abstract Preview: Purpose:
Photon-counting CT (PCCT) has become commercially available recently, offering significant potential to enhance patient care. However, it also introduces unique challenges. One such challe...

Mechanistical Modeling of Radiation Response of Parotid in Head and Neck Cancer Radiotherapy

Authors: Rachel B. Ger, Xun Jia, Youfang Lai, Todd R. McNutt, Xingyi Zhao

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Radiotherapy (RT) plays an essential role for head and neck (HN) cancer treatment but often results in xerostomia due to salivary gland damage. It is important to mechanistically model the ra...

Multi-Sid Optimization for 4 Pi Robotic Radiotherapy

Authors: Qihui Lyu, Dan Ruan, Ke Sheng, Jingjie Yu

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose: The robotic arm radiotherapy platform enables flexible delivery of non-coplanar and non-isocentric radiotherapy with variable Source-to-Isocenter Distances (SIDs). However, the high degrees o...

Multi-Vendor Validation of a Deep Learning-Based Synthetic CT Generation Model for MR-Only Radiotherapy Planning in the Pelvis

Authors: Gregory Bolard, Rabten Datsang, Sarah Ghandour, Timo Kiljunen, Pauliina Paavilainen, Sami Suilamo, Katlin Tiigi

Affiliation: Turku University Hospital, Virginia Commonwealth University, MVision AI, North Estonia Medical Centre, Docrates Cancer Center, Hopital Riviera-Chablais

Abstract Preview: Purpose: To verify the performance of a vendor-neutral deep learning model for synthetic CT generation from T2-weighted and balanced steady-state MR sequences to support both MR-only simulation and MR...

NA-Unetr: A Neighborhood Attention Transformer Network for Enhanced 3D Segmentation of the Left Anterior Descending Artery

Authors: Hassan Bagher-Ebadian, Ahmed I Ghanem, Joshua P. Kim, Chengyin Li, Rafi Ibn Sultan, Kundan S Thind, Dongxiao Zhu

Affiliation: Wayne State University, Department of Radiation Oncology, Henry Ford Health-Cancer, Detroit, MI and Alexandria Department of Clinical Oncology, Faculty of Medicine, Alexandria University, Henry Ford Health

Abstract Preview: Purpose: Accurate segmentation of the Left Anterior Descending (LAD) artery in free-breathing 3D treatment planning CT is crucial for radiotherapy but remains challenging due to its small size, comple...

NTCP Modeling and Dose-Volume Correlations for Rectal Symptoms Following Prostate Cyberknife SBRT.

Authors: Nicholas Joseph Casteloes, Brian T Collins, Sean P Collins, Shiva K. Das, Panayiotis Mavroidis, Michael Repka, Simeng Suy

Affiliation: University of South Florida, University of North Carolina

Abstract Preview: Purpose: To correlate four rectal symptoms with the dose to rectum in patients, who received SBRT with Cyberknife for prostate cancer. Also, to fit those dosimetric and outcome data by using a normal ...

On the Spectral Changes of Magna-Field Photon Beams Used in Total Body Irradiation

Authors: Larry A. DeWerd, Ahtesham Ullah Khan

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Total body irradiation (TBI) technique uses high energy photon beams with extended source-to-surface distances (SSDs) to irradiate the entire patient to prepare them for bone marrow or stem c...

Optimal Lattice Design for Spatially Fractionated Radiotherapy (SFRT) of Brain Metastasis in Gamma Knife (GK)

Authors: Brankica Andelic, Young-Bin Cho, Tara M. Gray, Andrew Robert Hadfield, Hakan Nordstrom

Affiliation: Elekta, Cleveland Clinic

Abstract Preview: Purpose: Spatially Fractionated Radiotherapy (SFRT) requires highly modulated dose distribution inside a tumor volume optimized using sets of planning structure of spheres in a lattice arrangement. To...

Optimizing Prostate Cancer Radiotherapy: Comprehensive Analysis of Automated Planning with Neural Network-Based Dose Prediction

Authors: Seungtaek Choi, Laurence Edward Court, Eun Young Han, Yusung Kim, Hunter S. Mehrens, Tucker J. Netherton, Shiqin Su

Affiliation: The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Automated treatment planning is gaining traction for its enhanced consistency and efficiency. A key challenge, however, lies in the inability of neural network dose predictions directly trans...

Patient-Specific Deep Reinforcement Learning Framework for Automatic Replanning in Proton Therapy for Head-and-Neck Cancer

Authors: Malvern Madondo, Mark McDonald, Zhen Tian, Christopher Valdes, Ralph Weichselbaum, Xiaofeng Yang, David Yu, Jun Zhou

Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Chicago, Emory University, Department of Radiology, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Head-and-neck (HN) cancer patients often experience significant anatomical changes during treatment course. Proton therapy, particularly intensity-modulated proton therapy (IMPT), is sensitiv...

Performance Evaluation of Patient Demographics Model-Based Liver Volumetry

Authors: Yasaman Anbari, Srinivas Cheenu Kappadath, Benjamin P. Lopez, Armeen Mahvash, Ali Yousefi

Affiliation: University of Houston, UT MD Anderson Cancer Center

Abstract Preview: Purpose: Patient-demographics-model-based liver volumetry is well-established for determining the future liver remnant following hepatectomy. We used gold-standard CT liver segmentation to validate th...

Phantom Assessment for Treating Large Tumors with Biology-Guided Radiotherapy (BgRT)

Authors: Jon Burns, Angela J Da Silva, Andrew Groll, Gopinath Kuduvalli, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma, Timothy Pok Chi Yeung

Affiliation: Reflexion Medical Inc,, RefleXion Medical

Abstract Preview: Purpose: Biology-guided radiotherapy uses positron emissions from FDG-avid tumor volumes to provide a of the planned prescribed dose with high accuracy. The purpose of this work is to characterize BgR...

Photon Counting CT Method for Accurate Effective Atomic Number and Electron Density Measurement

Authors: Mohammed Alzaabi, Abderaouf Behouch, Nabil Maalej, Aamir Raja, Briya Tariq

Affiliation: Khalifa University

Abstract Preview: Purpose: Spectral Photon Counting CT (SPCCT) has emerged as a transformative technology in CT imaging capable of producing images from distinct energy windows, allowing improved material characterizat...

Photon-Counting CT Versus Dual Energy CT for Liver Fat Volume Fraction Assessment

Authors: Chao Guo, Xinhua Li, Michael F. McNitt-Gray, Di Zhang, Yifang (Jimmy) Zhou

Affiliation: UCLA, David Geffen School of Medicine at UCLA, Cedars-Sinai Medical Center

Abstract Preview: Purpose: The objective was to quantify the liver fat volume fraction (FVF) with virtual monochromatic imaging (VMI) using photon-counting CT (PCCT) and dual energy CT (DECT).
Methods: A custom desi...

Predicting Brain V60% in Linac-Based Single-Isocenter-Multiple-Targets (SIMT) Stereotactic Radiosurgery Using Machine Learning

Authors: John Ginn, Zhuoyun Huang, Yongbok Kim, Ke Lu, Chunhao Wang, Yibo Xie, Zhenyu Yang, Jingtong Zhao

Affiliation: Duke University, Duke Kunshan University

Abstract Preview: Purpose: This study aims to develop and validate a machine learning model for predicting V60%, a critical dosimetric metric in LINAC-based Single-Isocenter-Multiple-Targets (SIMT) stereotactic radiosu...

Presenting a Novel Treatment Scheme for Debulking Unresectable Large Tumors: Feasibility, Safety and Patient Reported Early Clinical Outcomes of SBRT Immediately Post-Spatially Fractionated Radiotherapy Delivery

Authors: James Knight II, Joshua Misa, Damodar Pokhrel, William St Clair, Eddy S Yang

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Highly-heterogenous sieve-like dose distribution via SFRT to large/bulky tumors (≥6 cm) could enhance tumor cell-death via both direct/indirect cell-kill mechanisms. Adding highly-conformal S...

Proposed Method for Optimization of Lattice Radiation Therapy Using an Advanced Ring Gantry Linac

Authors: Eduardo Florian, Osmar Obdulio Hernandez, Otto Hurtarte, Milton Ixquiac, Erick Orlando Montenegro, Franky Eduardo Reyes, Edgar Aparicio Ruiz, Kevin Vega, Vicky de Falla

Affiliation: Liga Nacional Contra el Cancer, Liga Nacional Contra el Cancer/INCAN, Liga Nacional Contra el Cancer / INCAN, Liga Nacional Contra el Cancer and Universidad de San Carlos de Guatemala, Liga Nacional Contra el CĂĄncer / INCAN

Abstract Preview: Introduccion:
Lattice Radiation Therapy (LRT) is a form of spatially fractionated radiation therapy (SFRT) designed to improve control of large tumors by delivering ablative doses while minimizing ...

Quality Monitoring of Temporal Performance Degradation in Clinical Use of AI Auto-Segmentation

Authors: Ali Ammar, Quan Chen, Jingwei Duan, Yi Rong, Nathan Y. Yu, Libing Zhu

Affiliation: Mayo Clinic Arizona, University of Alabama at Birmingham

Abstract Preview: Purpose: Clinical performance of deep learning-based auto-segmentation (DLAS) can degrade over time due to AI “aging” from unseen data input compared to the initial model training data. This study aim...

Quantitative Forward Modeling of Propagation-Based X-Ray Phase-Contrast Imaging at Clinical Scale

Authors: Giavanna Luisa Jadick, Patrick J La Riviere, Cailey Riggs

Affiliation: University of Chicago

Abstract Preview: Purpose: We explore the accuracy of physics models for propagation-based x-ray phase-contrast imaging (XPCI) with an eye to future clinical implementation, providing a practical assessment of detectio...

Radiation Dosimetry Using Optically Stimulated Luminescence Detection from Luxel with a CCD Camera System

Authors: Mohammad Nazmul Alim, Regina DeWitt

Affiliation: Department of Physics, East Carolina University,, Department of Physics, East Carolina University

Abstract Preview: Purpose: This study quantifies the ability of Luxel (Al₂O₃:C) to measure radiation dose from a Moxtek X-ray source. Key aspects of OSL dosimetry, including OSL curves, dose response, depth dose, and b...

Radiation Shielding Considerations for Ultra-High Dose Rate Electron Flash Radiation Therapy

Authors: Alexandru Badalan, Peter Petric, I. Antoniu Popescu, Andrew Kyle Henderson Robertson

Affiliation: Bc Cancer, BC Cancer - Vancouver, BC Cancer

Abstract Preview: Purpose: Ultra-high dose rate (>40 Gy/s) or “FLASH” radiation therapy (RT) has the potential to improve cancer treatment through reduced radiation side effects. While electron FLASH beams can be produ...

Radiopathomic Characterization of Chemoradiation Resistance in Preclinical Models of Head and Neck Cancer

Authors: Rico Castillo, Katherine Gonzalez, Casey C. Heirman, Kyle J. Lafata, Xiang Li, Yvonne M Mowery, Yvonne M Mowery, Allison Pittman, Ashlyn G. Rickard, Breylon Riley

Affiliation: Duke University, Department of Radiation Oncology, Duke University, University of Pittsburgh

Abstract Preview: Purpose: To evaluate the relationships between quantitative imaging biomarkers and chemoradiation resistance in head and neck squamous cell carcinoma (HNSCC) using preclinical mouse models.

Met...

Ratoguide: Evaluation of AI-Driven Fully Automated Treatment Planning Support System for Lung SBRT

Authors: Keiichi Jingu, Noriyuki Kadoya, Takafumi Komiyama, Takeru Nakajima, Hikaru Nemoto, Hiroshi Onishi, Masahide Saito, Ryota Tozuka

Affiliation: Department of Radiology, University of Yamanashi, Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Department of Advanced Biomedical Imaging, University of Yamanashi

Abstract Preview: Purpose: We evaluated the accuracy of a new AI-based fully automated planning software in stereotactic body radiotherapy (SBRT) for early-stage lung cancer.
Methods: We collected data from 125 pati...

Reducing Distal-Edge Toxicity in Breast Proton Therapy Via LETd and Track-End Optimization

Authors: Matthew Case, Richard Castillo, Sunil Dutta, Edgar Gelover, Katja M. Langen, Alexander Stanforth, Mingyao Zhu

Affiliation: Emory University

Abstract Preview: Purpose: To evaluate the application of LETd and track-end (TE) objective functions during the optimization of breast proton therapy plans to decrease the risk of lung toxicity and rib fractures.
M...

Retrospective Comparison of Treatment Plan Quality As a Function of Delivery Time for SBRT Thoracic Tumors

Authors: Danielle Renee Daiger, Nicholas N. Sperling

Affiliation: University of Toledo, University of Toledo Medical Center

Abstract Preview: Purpose:
To retrospectively evaluate the impact of planned delivery time on plan quality metrics for breath-hold VMAT SBRT thoracic cancer patients.
Methods:
Patients treated for SBRT thoraci...

Retrospective Postimplant Dosimetry: Comparison of Line and Point Source for 131cs Low Dose Rate Intracranial Implant Brachytherapy

Authors: Tirthraj Adhikari, Timothy J Allen, Abdullah A. Alshreef, Clara Ferreira

Affiliation: Medical School Department of Radiation Oncology University of Minnesota, University of Minnesota, Loma Linda University Medical Center

Abstract Preview: Purpose: GammaTile Brachytherapy with 131Cs is an effective treatment for glioblastomas, offering local control with minimal radiation necrosis. While the line source model is preferred for dose distr...

Tackling the Challenge of Multi-Target Metastases Treatment: Evaluation of Ethos Treatment Planning System

Authors: Avery Antes, Bulent Aydogan, Rama Chicfeh, Erik Pearson, Neslihan Sarigul

Affiliation: The University Of Chicago, The University of Chicago

Abstract Preview: Purpose: This study evaluates the performance of the Ethos Treatment Planning System (TPS) in managing oligometastatic cancer patients previously treated using multiple isocenter plans.
Methods: Th...

Task Specific Image Quality Assessment Using Spectral Photon-Counting CT.

Authors: Azza Mohamed Ahmed, Nadine Francis, Osama Khan, Nabil Maalej, Aamir Raja, Briya Tariq

Affiliation: Khalifa University

Abstract Preview: Purpose: The study aims to evaluate the task-specific diagnostic performance of spectral photon-counting CT (SPCCT) using application-specific phantoms.
Methods:
Parameters such as linearity res...

The Impact of Implant Position and Different Radiotherapy Techniques on Dosimetry in Post-Mastectomy Breast Reconstruction for Breast Cancer

Authors: Xiu tong Lin

Affiliation: Department of Radiation physics and technology, Shandong Second Provincial General Hospital

Abstract Preview: Purpose: To compare the dosimetric differences between the photon and proton plans and between the different target according to the placement of the implants for patients undergoing radiotherapy afte...

The Role of 3D Vane MRI in Accurate Phase Matching with 4D-CT for Motion Representation in Liver Cancer Radiotherapy

Authors: Jiayun Chen, Shengqi Chen, Junchao Li, Fei Liu, Jianan Wu

Affiliation: Cancer Hospital Chinese Academy of Medical Sciences, Shenzhen Center, Tongji Medical College, Huazhong University of Science & Technology, School of Electronic Engineering, Beijing University of Posts and Telecommunications, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: To assess if 3D Vane MRI can accurately depict the motion of the target volume and OARs.
Methods: This retrospective study included 54 liver cancer patients who underwent both 3D Vane MRI ...

Uncertainties on Synthetic-CT Generation from CBCT: Another Layer of Complexity in Abdominal Adaptive Radiotherapy

Authors: Laura I. Cervino, Wendy B. Harris, Paulo Quintero, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To evaluate the impact of the prediction uncertainty from CBCT-based synthetic CT (sCT) generation in abdominal adaptive radiotherapy.

Methods: CT and CBCT images from 65 abdominal pat...

Using Machine Learning to Predict Esophagitis Risk in Lung Cancer Radiotherapy Based on Clinical and Dosimetric Factors

Authors: Ibtisam Almajnooni, Siyong Kim, Nathaniel Miller, Elisabeth Weiss, Lulin Yuan

Affiliation: Virginia Commonwealth University

Abstract Preview: Purpose: Radiation-induced esophagitis (RE) is a common concern in lung cancer IMRT. Recent studies have indicated that the risk of radiation side effects varies greatly with patients’ baseline clinic...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...

Voxel-Based Radiobiological Modelling for Evaluating Radiotherapy Treatment Plans in Relation to Radiation-Induced Acute Mucosal Toxicity (including oral and pharyngeal mucositis): A Single-Institutional Study Focused on Head-and-Neck Carcinoma.

Authors: Rama Bhawani, Mary Joan, Ajay Katake, Munish Kumar, Chhape Ram, Megha Sharma, Balbir Singh, Vikram Singh

Affiliation: SLBSGMC & HOSPITAL, MOHANDAI OSWAL HOSPITAL, WOCKHARDT HOSPITAL, Christian Medical College and Hospital,, AMERICAN ONCOLOGY INSTITUTE

Abstract Preview: Purpose: This study aims to evaluate the utility of voxel-based radiobiological modelling in assessing IMRT radiotherapy treatment plans concerning radiation-induced acute mucosal toxicity, specifical...

“You Can’t Unsee It”: Clinical Scintillation Imaging Enables First Localized Comparison between In Vivo dosimetry Measurements and the Treatment Plan

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Lesley A Jarvis, Allison Matous

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose: In vivo dosimetry (IVD) is underutilized, in part, because measured point doses cannot be accurately localized to the patient or treatment planning system (TPS), complicating the clinical and...