Search Submissions 🔎

Results for "validation application": 47 found

A Clinically Aligned Embedding Model for Glioma Prognostication Via Radiology-Pathology Report Matching

Authors: Steve Braunstein, Yannet Interian, Hui Lin, Bo Liu, Janine Lupo, Olivier Morin, Benedict Neo

Affiliation: Radiation Oncology, University of California San Francisco, Graduate Program in Bioengineering, University of California San Francisco-UC Berkeley, Department of Radiation Oncology, University of California San Francisco, Department of Data Science, University of San Francisco, University of San Francisco

Abstract Preview: Purpose: Large Language Models (LLMs) demonstrate strong general text comprehension but remain limited in oncology due to insufficient contextual alignment. We pilot embedding alignment through radiol...

A Diffusion-Based AI Framework for Continuous Deformable Image Registration and Time-Resolved Dynamic CT Generation

Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Gregory Szalkowski, Qingying Wang, Kangning Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Respiratory motion management is crucial for accurate radiation delivery to moving targets while protecting healthy tissue, relying on time-resolved volumetric imaging and continuous deformab...

A Hybrid Transformer-CNN for Tracking-Free 3D Ultrasound Volume Reconstruction from 2D Freehand Scans

Authors: Wenfeng He, Tian Liu, Pretesh Patel, Richard L.J. Qiu, Keyur Shah, Tonghe Wang, Xiaofeng Yang, Chulong Zhang

Affiliation: Icahn School of Medicine at Mount Sinai, Emory University, Medical Physics Graduate Program, Duke Kunshan University, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: This study introduces a tracking-free approach to reconstruct 3D ultrasound (US) volumes from 2D freehand US scans. By eliminating the reliance on external tracking systems, this method aims ...

A Multimodal CAD System for Breast Cancer Detection: Integrating MRI, DBT, and Mammography for Dense Breast Challenges

Authors: Si-Wa Chan, Yuan-Yu Lee, Zhi-Ying Li, Jia-Wei Liao, Hui-Yu Cathy Tsai

Affiliation: Department of Radiology, Taichung Veterans General Hospital​, Institute of Nuclear Engineering and Science, National Tsing Hua University

Abstract Preview: Purpose: Dense breast tissue reduces the sensitivity of mammography, posing diagnostic challenges, especially for Asian women with high breast density (up to 50%). Current single-modality techniques o...

A Vision-Language Model for T1-Contrast Enhanced MRI Generation for Glioma Patients

Authors: Zachary Buchwald, Zach Eidex, Richard L.J. Qiu, Justin R. Roper, Mojtaba Safari, Hui-Kuo Shu, Xiaofeng Yang, David Yu

Affiliation: Emory University and Winship Cancer Institute, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Gadolinium-based contrast agents (GBCA) are commonly used for patients with gliomas to delineate and characterize the brain tumors using T1-weighted (T1W) MRI. However, there is a rising conc...

AI-Based SBRT Dose Prediction Directly from Diagnostic PET/CT: Applications for Multi-Disciplinary Lung Cancer Care

Authors: Pradeep Bhetwal, Wookjin Choi, Adam Dicker, Rupesh Ghimire, Yingcui Jia, Lauren Nkwonta, Yevgeniy Vinogradskiy, Wentao Wang, Maria Werner-Wasik

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: Multi-disciplinary clinics are becoming standard of care for patients with lung cancer treated with SBRT. To improve clinical decision support in a multi-disciplinary clinic, it would be bene...

Advancing Flash Radiotherapy: Intercomparison of Parameters between Two Institutions to Optimize Clinical Applications.

Authors: Amir Abdollahi, Celine Karle, Michele M. Kim, Constantinos Koumenis, Andrea Mairani, Erato Stylianou Markidou

Affiliation: Heidelberg Ion-Beam Therapy Center - Department of Radiation Oncology, German Cancer Research Centre(DKFZ), University of Pennsylvania, Physics Dep. University of Cyprus

Abstract Preview: Purpose: The aim is to compare FLASH dose-rate RT generated with protons and carbon (HIT) and compare to protons (UPenn) to provide evidence for equipotency of FLASH vs. standard RT to tumor growth co...

Assessment of Viscoelastic Changes in Ex Vivo Liver Tissue Using Pulsed Magnetomotive Ultrasound during Magnetic Hyperthermia

Authors: David Alejandro Collazos Burbano, Antonio Adilton Oliveira Carneiro, Paul L. Carson, Jose Eduardo Freire, Theo Zeferino Pavan, Joao Henrique Uliana, Nicholas Zufelato

Affiliation: University of São Paulo, University of Michigan, University of Sao Paulo

Abstract Preview: Purpose: Develop a theranostic platform that integrates magnetic hyperthermia (MH), ultrasound, and magnetic nanoparticles (MNPs) to improve diagnosis, treatment, and monitoring of hyperthermia proced...

Construction and Application Study of a Deep Learning-Based Iscout-Guided Precision Radiotherapy Positioning Error Prediction Model for Breast Cancer

Authors: Fangfen Dong, Jiaming Li, Xiaobo Li, Weipei Wang, Zhixin Wang, Bing Wu, Benhua Xu, Yong Yang, Yifa Zhao

Affiliation: Department of Radiation Oncology, Fujian Medical University Union Hospital/Fujian Key Laboratory of Intelligent Imaging and Precision Radiotherapy for Tumors/Clinical Research Center for Radiology and Radiotherapy of Fujian Province (Digestive, Hematologi, Zhangpu County Hospital, School of Medical Imaging, Fujian Medical University

Abstract Preview: Purpose: To explore the construction and clinical application value of a deep learning-based positioning error prediction model, providing a reference for optimizing iSCOUT system-guided precision rad...

Cycle-Consistent Multi-Task Automated Segmentation and Synthetic CT Generation Model for Adaptive Proton Therapy

Authors: Derek Tang, Susu Yan

Affiliation: Massachusetts General Hospital

Abstract Preview: Purpose: To evaluate the performance of a multi-task automated-segmentation and synthetic CT generation model (sCT) and investigate its application in an adaptive proton therapy workflow.
Methods: ...

Deep-Learning Convolutional Neural Network-Based Breast Cancer Localization for Mammographic Images: A Study on Simulated and Clinical Images

Authors: Xiaoyu Duan, Xiang Li, Wenbo Wan, Lei Zhang, Yiwen Zhang

Affiliation: Duke University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: Breast screening has been proved to reduce breast cancer mortality by early detection and treatment for patients. Mammography is the most common and widely used technique for breast cancer sc...

Design and Construction of a Geometrical and Head Phantom with Internal Carotid Inserts for Flow Simulation in Image-Derived Input Function with 3T and 7T MR-Brainpet Insert Studies.

Authors: Dirk Grunwald, Hans Herzog, Hidehiro Iida, N. Jon Shah, Usman Khalid, Manfred Lennartz, Philipp Lohmann, Ceren Memis, Tobias Meurer, Claudia Regio Brambilla, Jürgen Scheins, Lutz Tellmann, Christoph W. Lerche, Martin Wiesmann, Karl Ziemons

Affiliation: FH Aachen University of Applied Sciences, Department of Chemistry and Biotechnology, Clinic for Diagnostic and Interventional Neuroradiology, Uniklinik Aachen,, Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH,, Central Institute for Engineering, Electronics and Analytics (ZEA-1), Forschungszentrum, Turku PET Center, Institute of Biomedicine, Faculty of Medicine, University of Turku,

Abstract Preview: Purpose: Quantitative brain studies with positron emission tomography (PET) often require an arterial input function (AIF), which traditionally requires arterial cannulation. However, this is invasive...

Design, Optimization, and Preclinical Validation of a Novel Applicator Integrating Real-Time Dose Monitoring for Ultra-High Dose Rate (FLASH) Electron Radiotherapy

Authors: Javier Chiasson, Dominique Guillet, Arthur Lalonde, Bryan R. Muir, James Renaud, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal, National Research Council

Abstract Preview: Purpose: To develop, optimize and validate a novel applicator for ultra-high dose rate (UHDR) electron radiotherapy incorporating an electrostatically shielded beam current transformer (BCT) for real-...

Developing a Comprehensive Multi-Modal Framework for Population-Scale Liver Volumetry: Insights and Predictive Models

Authors: Mustafa Bashir, Diana Kadi, Kyle J. Lafata, Jacob A. Macdonald, Mark Martin, Yuqi Wang, Marilyn Yamamoto

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Department of Electrical and Computer Engineering, Duke University, Department of Radiology, Duke Unversity

Abstract Preview: Purpose: To develop a high-throughput, automated-data-interrogation pipeline for integrating imaging and clinical information to identify key determinants of liver volume (LV), enabling population-sca...

Development and Validation of an MR-Compatible Anthropomorphic Motion Phantom for Liver Motion Assessment and MR-Linac Gating System Optimization

Authors: Tsuicheng D. Chiu, Weiguo Lu, Aaron Thomlinson, You Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose: To develop and validate an MR-compatible anthropomorphic motion phantom to assess liver motion, real-time dosimetry, and gating system performance under controlled and reproducible respirator...

Development of Treatment Planning System for Carbon Ion Radiotherapy in Yonsei Cancer Center

Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojin Kim, Jin Sung Kim, HO Lee, Sac Lee, Yongdo Yun

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: Carbon ion radiotherapy (CIRT) offers the advantage of a greater relative biological effectiveness (RBE) weighted dose, which must be integrated into the treatment planning system (TPS). This...

Development of a Comprehensive Thoracic Re-Irradiation Database and Investigation of Time-Dependent Dose-Recovery Dynamics for Toxicity Modeling

Authors: Victoria Doss, Tsion Gebre, Rachel B. Ger, Esi A Hagan, Elaina Hales, Russell K Hales, Xun Jia, Heng Li, Dezhi Liu, Todd R. McNutt, Meti Negassa, Anas Obaideen, Tinker Trent, K. Ranh Voong, Cecilia FPM de Sousa

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: As cancer care advances, more patients require re-irradiation, yet evidence-based data is lacking. This study aimed to develop a thoracic re-irradiation database and explore time-dependent re...

Development of a Knowledge-Based Planning Model for Intensity Modulated Proton Therapy in Breast Cancer Treatment

Authors: Parker Anderson, Elizabeth L. Bossart, Jonathan Cyriac, Nesrin Dogan, Robert Kaderka, Yihang Xu

Affiliation: University of Miami, University of Miami, Sylvester Comprehensive Cancer Center, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose:
Knowledge-based planning (KBP) can enhance the treatment planning process in cancer radiotherapy (RT). By training a KBP model with high-quality treatment plans developed by experts, dose-...

Development of a Novel Deformable Pelvis Phantom to Support Upright Applications

Authors: Adam P. Berdusco, Matthew R. Ceelen, Renata Farrell, Carri K. Glide-Hurst, Will Martin, Charles F. Maysack-Landry, Morgan A. McGauley, James Rice, Jordan M. Slagowski, Yuhao Yan

Affiliation: Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Upright radiotherapy (RT) is now available although this novel vertical CT and positioner presents unique challenges for quality assurance and testing methodologies. We have designed and buil...

Development of a Robust 3D-Ultrasound (3DUS) Quality Assurance (QA) Framework for a Real-Time Needle-Tracking System in HDR GYN Brachytherapy

Authors: Diandra Ayala-Peacock, Lindsey Hendricks Bloom, Oana I. Craciunescu, Julie A. Raffi, Megan K. Russ, Ryan Sanford, Rajesh Venkarataman

Affiliation: Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, Duke University Medical Center, Duke University, Eigen Health, Duke Univesity

Abstract Preview: Purpose: To establish a robust QA framework to characterize and ensure accuracy, reliability, and reusability of a transrectal ultrasound (TRUS)-based needle tracking system (NTS) for clinical HDR GYN...

Development of an Eclipse Scripting API-Based Toolbox for Automated Planning in Non-Small Cell Lung Cancer: Feasibility and Validation Study

Authors: Ming Chao, Hao Guo, Tenzin Kunkyab, Yang Lei, Tian Liu, Kenneth Rosenzweig, Robert Samstein, Junyi Xia, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose:
This study aims to develop and validate an Eclipse Scripting Application Programming Interface (ESAPI)-based planning toolbox that incorporates preset human expertise to improve planning e...

Efficient Monte Carlo Proton Dose Calculation Using Denoising Diffusion Probabilistic Models

Authors: Chieh-Ya Chiu, Shen-Hao Li, Hsin-Hon Lin, Shu-Wei Wu

Affiliation: Department of Medical Imaging and Radiological Sciences, Chang Gung University, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital Linkou

Abstract Preview: Purpose: Monte Carlo simulation enables precise calculation of dose distribution in proton therapy through tracing the radiation particles with patient tissues. However, achieving clinical-level preci...

Energy Dependency of Biological Effects from Radiation Scattering Around Medical Implants in Particle Therapy

Authors: John Ford, Yu Fujiwara, Isao Murata, Zavier Ndum Ndum

Affiliation: Osaka University, Texas A&M University

Abstract Preview: Purpose: This study investigates how particle energy affects radiation quality and biological effectiveness with the inclusion of medical implants. Our research group used microdosimetric analysis to ...

Evaluating Three Practical Approaches to Managing Dose Accumulation in Normal Tissues during Radiation Re-Treatments

Authors: Derek A. Fiedler, Nixon Gutierrez, Quyen L. Jones, Zejian Liu, Tatsiana Reynolds

Affiliation: Texas Oncology, Minnesota Oncology, US Oncology

Abstract Preview: Purpose: Optimize patient safety and treatment efficacy during radiation re-treatment planning. Provide a comprehensive comparison of the methods by focusing on their applicability, accuracy, and limi...

Evaluating Tumor Shrinkage Using Fractionated Radiotherapy: A Mixed Finite Element Method (FEM) for Free Boundary Problem

Authors: Xianjin Dai, PhD, Xiang Wan, Lei Xing, Qiuyun Xu, Lewei Zhao, Zeyu Zhou

Affiliation: Department of Radiation Oncology, Stanford University, Carl Zeiss X-ray Microscopy, Department of Mathematics and Statistics, Loyola University Chicago, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: The purpose of this study is to examine and quantify tumor shrinkage over time in response to fractionated radiotherapy. We seek to establish a predictive model that can provide a systematic ...

Evaluating the Performance and Limitations of an Automated Treatment Planning Tool for Intact Breast Radiotherapy across Diverse Patient Populations

Authors: Shatha Al Afifi, Hana Baroudi, Leonard Che Fru, Laurence Edward Court, Suzanne B. Evans, Kent A. Gifford, Adam D. Melancon, Melissa P. Mitchell, Issa Mohamad, Patricia Murina, Manickam Muruganandham, Tucker J. Netherton, Callistus M. Nguyen, Joshua S. Niedzielski, Deborah L. Schofield, Simona Shaitelman, Willie Shaw, Sanjay S. Shete, Adam Shulman, Brendon Smith, Sheeba Thengumpallil, Carlos Daniel Venencia, Conny Vrieling

Affiliation: University of Cape Town, MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, University of the Free State, UT MD Anderson Cancer Center, King Hussein Cancer Center, Instituto Zunino - Fundacion Marie Curie, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Dra., Hirslanden Clinique des Grangettes, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Therapeutic Radiology, Yale University School of Medicine, Yale University, The University of Texas, MD Anderson, Houston TX

Abstract Preview: Purpose:
Automated contouring and planning tools are usually trained on single-institution datasets, seldom tested across diverse patient populations. This introduces a risk of population bias, res...

Evaluation of an Analytical Simulation Technique By Comparing Transmitted Spectra Against GEANT4 through a Hafnium-Loaded Heterogeneous Phantom

Authors: Sabrina Campelo, Sandun Y. Jayarathna, Adam D. Melancon, Paige L. Nitsch, Christopher Ryan Peeler, Julianne M. Pollard-Larkin, Ramaswamy Sadagopan, Xiaochun Wang, George Zhao

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Development of an in-house analytical simulation for streamlining photon counting detector (PCD) system protocols through measuring transmitted photon energy spectra through a Hafnium (Hf)-lo...

First in-Vivo Application of a Novel Precision Small Animal Irradiation Platform with Proton IMPT Delivery and Advanced on-Board Image-Guidance

Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf

Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital

Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...

From Noisy Signals to Accurate Maps: Transforming Look-Locker MRI with an Intelligent T₁ Estimation

Authors: Prabhu C. Acharya, Hassan Bagher-Ebadian, Stephen L. Brown, James R. Ewing, Mohammad M. Ghassemi, Benjamin Movsas, Farzan Siddiqui, Kundan S Thind

Affiliation: Michigan State University, Oakland University, Henry Ford Health

Abstract Preview: Purpose: Accurate T1 quantification using T One by Multiple Read Out Pulse (TOMROP) sequences is essential for physiological assessments in dynamic-contrast-enhanced (DCE) MRI and T1 mapping studies. ...

G4BraggReflection: Pioneering Wave-Particle Simulations for Convergent Radiotherapy and Beyond

Authors: Dirk A Bartkoski, Michael Kleckner, Dongyeon Lee, Reza Reiazi, Mohammad Reza Salehpour

Affiliation: The University of Texas MD Anderson Cancer Center, Convergent-RnR

Abstract Preview: Purpose:
To develop and validate G4BraggReflection, a novel physics process within Geant4, designed to incorporate diffraction properties resulting in Bragg reflection into Monte Carlo simulations....

Hands-on AI Education for Radiology Residents

Authors: Wilfred R Furtado, Gary Y. Ge, James Lee, Jie Zhang

Affiliation: University of Kentucky

Abstract Preview: Purpose: Despite advancements in Artificial Intelligence (AI) and its growing role in clinical practices like radiology, formal AI education remains limited in medical training. This gap contributes t...

High-Fidelity Monte-Carlo Model Development and Validation of a 0.5T Bi-Planar Linac-MR Using Topas: Multileaf Collimator Modeling, Positioning, and Dose Verification in Slab Phantoms

Authors: B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Gawon Han, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip

Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute

Abstract Preview: Purpose: To develop and validate a high-fidelity Monte-Carlo (MC) model of a 0.5T bi-planar Linac-MR in TOPAS, focusing on accurate Multileaf Collimator (MLC) modelling and positioning for open apertu...

Identification of Potential Patients for Resimulation and Adaptive Planning By Machine Learning

Authors: Mark Ashamalla, Renee Farrell, Jinkoo Kim, Kartik Mani, Xin Qian, Samuel Ryu, Yizhou Zhao

Affiliation: Stony Brook Medicine, Stony Brook University Hospital

Abstract Preview: Purpose: Adaptive planning is increasingly used in head and neck radiation therapy due to factors like tumor response or changes in patient anatomy. However, methods such as resimulation or offline re...

Imaging under pressure: validation and application of a mammography breast compression pressure estimation algorithm

Authors: Melissa L. Hill

Affiliation: Volpara Health

Abstract Preview: N/A...

Impact of Serial Passage on Radiation Response and Angiogenic Activity in Head and Neck Cancer Patient-Derived Xenografts

Authors: Liliana Berube, Randall J Kimple, Kwangok P Nickel, Hannah Sondreal

Affiliation: UW Madison

Abstract Preview: Purpose: The fidelity of patient-derived xenografts (PDXs) is crucial for their application in translational research, as it ensures that these models accurately retain the properties of the original ...

Integrating Radiomics and ADC Ratio for Multicenter Prostate Cancer Diagnosis: A Harmonized Machine Learning Approach

Authors: George Agrotis, Marios Myronakis, Dimitrios Samaras, Kyriaki Theodorou, Ioannis Tsougos, Vassilios Tzortzis, Maria Vakalopoulou, Alexandros Vamvakas, Aikaterini Vassiou, Marianna Vlychou

Affiliation: Medical Physics Department, Medical School, University of Thessaly, Department of Radiology, University of Thessaly, Netherland Cancer Institute, Department of Urology, University of Thessaly, CentraleSupelec, University Paris-Saclay

Abstract Preview: Purpose: Prostate cancer (PCa) diagnosis remains challenging due to discrepancies in Gleason Scoring (GS) and risks of overdiagnosis and underdiagnosis. Multiparametric MRI (mpMRI), including Apparent...

Investigating Interstitial Fluid Pressure and Hydraulic Conductivity By Examining the Biophysical Properties of Drug Transport Using Cross Voxel Exchange Model and Dynamic Contrast Enhanced MRI

Authors: Catherine Coolens, Janny Yeyoung Kim, Michael Milosevic, Noha Sinno

Affiliation: Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: In solid tumors, Interstitial fluid pressure (IFP) acts as a barrier to molecular transport to the tumor center and serves as a predictor of cancer patients’ treatment responsiveness. The nov...

Lung-Equivalent Compressible Material As Core Component for a Miniaturized Breathing Phantom Prototype

Authors: Silvia Calusi, Lucia Cavigli, Alberto Dalla Mora, Laura Di Sieno, Giacomo Insero, Riccardo Lisci, Livia Marrazzo, Cosimo Nardi, Stefania Pallotta, Andrea Profili, Fulvio Ratto, Giovanni Romano, Michaela Servi, Immacolata Vanore, Yary Volpe

Affiliation: Italian National Research Council IFAC-CNR, Institute of Applied Physics, Department of Physics, Politecnico di Milano, Department of Agricultural Food and Forestry System, University of Florence, Medical Physics Unit, Azienda Ospedaliero-Universitaria Careggi, Department of Industrial Engineering, University of Florence, Department of Experimental and Clinical Biomedical Sciences “Mario Serio”, University of Florence

Abstract Preview: Purpose: To develop a multi-purpose lung phantom prototype to replicate respiratory dynamics and morphological features observed in clinical radiological (CT and MR) imaging of lung parenchyma.
Met...

Optimizing Design to Enhance the Energy Separation in a Kv Dual-Layer Imager (DLI)

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Multi-layer flat-panel imagers can improve for clinical image-guided radiotherapy applications, including the enhanced visualization of soft tissue and a reduction in image artifacts. Each im...

Patient Specific Protocol Optimization in Cardiac CT: A Practical Approach to Its Validation

Authors: Zhihua Qi

Affiliation: Henry Ford Health

Abstract Preview: Purpose: State of the art cardiac CT has built-in automated, patient specific optimization, taking into account a number of factors including patient size, heart rate and others. It is crucial to deve...

Precision Radiotherapy Dose Prediction Using Foundation Model-Augmented Learning

Authors: Hilary P Bagshaw, Mark K Buyyounouski, Xianjin Dai, PhD, Praveenbalaji Rajendran, Lei Xing, Yong Yang

Affiliation: Department of Radiation Oncology, Stanford University, Massachusetts General Hospital, Harvard Medical School

Abstract Preview: Purpose: Artificial intelligence (AI)-driven methods have transformed dose prediction, streamlining the automation of radiotherapy treatment planning. However, traditional approaches depend exclusivel...

Prediction of Head and Neck Cancer Using Artificial Neural Network through Basic Health Data

Authors: Abdullah Hidayat, Wazir Muhammad

Affiliation: Florida Atlantic University

Abstract Preview: Purpose: This study aims to predict Head and Neck cancer using an artificial neural network (ANN) through readily available basic health data. The goal is to uncover hidden patterns and predictors in ...

Real Time Monte Carlo Dose Calculation for Clinical Cyberknife Radiation Therapy Based on Deep Learning Diffusion Model

Authors: Ruiyan Du, He Huang, Mingzhu Li, Ying Li, Hongyu Lin, Wei Liu, Shihuan Qin, Yiming Ren, Hui Xu, Lian Zhang, Xiao Zhang, Zunhao Zhang

Affiliation: Department of Radiation Oncology, Mayo Clinic, Medical AI Lab, The First Hospital of Hebei Medical University, Hebei Provincial Engineering Research Center for AI-Based Cancer Treatment Decision-Making, The First Hospital of Hebei Medical University, Department of Oncology, The First Hospital of Hebei Medical University

Abstract Preview: Purpose: Monte Carlo (MC) dose calculation is the gold standard in clinical CyberKnife radiation therapy (RT), considering its steep dose gradients and high-freedom non-coplanar beam angles, but extre...

Retrospective Study Using Avi Planner for Head and Neck Cancer Cases: Our Experience at Nsia-Luth Cancer Center, South - West Nigeria

Authors: Adebayo Abe, Samuel Olaolu Adeneye, Eben Aje, Bidemi I. Akinlade, Inioluwa Damilola Ariyo, Lilian Ekpo, Muhammad Habeebu, Adedayo O. Joseph, Charles S. Mayo, Noah Ndianaobong, Ikechi S Ozoemelam, Margaret Dideolu Taiwo, Godwin Uwagba

Affiliation: University of Michigan, University of Ibadan, University of Lagos, Missouri University of Science and Technology, NSIA-LUTH Cancer Center, University of Lagos, NSIA-LUTH Cancer Centre, NSIA-LUTH Cancer Center

Abstract Preview: Purpose:
Head and neck cancers (HNC) present significant challenges in radiotherapy due to complex anatomy and the proximity to critical organs at risk (OARs). These challenges are compounded in na...

Surface Dose Distribution Analysis Using Cherenkov Imaging for Total Skin Electron Therapy (TSET) with Scintillator and Osld Validation

Authors: Baozhu Lu, Hongjing Sun, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: This study aims to validate the feasibility of using Cherenkov imaging for surface dose distribution measurement during Total Skin Electron Therapy (TSET) by developing a perspective-correcte...

Ultra-Sparse-View Cone-Beam CT Reconstruction Based Strictly-Structure-Preserved Deep Neural Network in Image-Guided Radiation Therapy

Authors: Guangjun Li, Ying Song, Huanan Tang, Tianxiong Wu, Qiuyi Ye, Wei Zhang

Affiliation: West China Second Hospital of Sichuan University, United Imaging Healthcare, West China Hospital of Sichuan University

Abstract Preview: Purpose:
To propose a general low-dose reconstruction model for ultra-sparse-view cone-beam CT (CBCT) and evaluate its clinical application in improving image quality and reducing radiation dose fo...

Using a Generative Adversarial Network (GAN) for Source Particle Generation in Monte Carlo Radiation Therapy Simulations

Authors: Jiankui Yuan, Dandan Zheng, Tingliang Zhuang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, University of Rochester, Varian Medical Systems, Advanced Oncology Solutions

Abstract Preview: Purpose: In Monte Carlo (MC) radiation therapy dose calculations, latent variance exists when directly applying phase-space files (PSF) with a finite number of source particles, while the latter is pr...