Search Submissions 🔎

Results for "vmat delivered": 30 found

A Comparison of Segment-By-Segment Versus Cumulative Signal Evaluation for Patient-Specific QA Using the Integral Quality Monitor

Authors: John J. DeMarco, Farideh Pak, Olivia Grahm C Valadie

Affiliation: Cedars Sinai, Cedars-Sinai, Cedars-Sinai Medical Center

Abstract Preview: Purpose: To investigate the performance of the Integral Quality Monitor (IQM) device for patient-specific QA, focusing on segment-by-segment signal evaluation compared to cumulative signal evaluation....

A Deep Learning-Based Approach for Rapid Prediction of IMRT/VMAT Patient-Specific Quality Assurance for Online Adaptive Plans Generated with a 0.35T MR-Linac

Authors: Suman Gautam, Tianjun Ma, William Song

Affiliation: Virginia Commonwealth University

Abstract Preview: Purpose: We propose an artificial intelligence (AI)-based method to rapidly predict the patient-specific quality assurance (PSQA) results for magnetic resonance (MR)-guided online adaptive radiation th...

A Method to Check the Consistency and Reproducibility of VMAT Delivery

Authors: Chloe Doen Kim, Patricia E. Lindsay, Bern Norrlinger, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, Queen's University, Princess Margaret Cancer Centre

Abstract Preview: Purpose: To propose a method to check the consistency of VMAT delivery on linear accelerator (LINAC) with a commercial three-dimensional array device. The method is insensitive to the correction facto...

A Novel Non-Measured and DVH-Based IMRT QA Framework with Machine Learning for Instant Classification of Susceptible Lung SBRT VMAT Plans

Authors: Chuan He, Anh H. Le, Iris Z. Wang

Affiliation: Roswell Park Comprehensive Cancer Center, Cedars-Sinai

Abstract Preview: Purpose: To develop a non-measured and DVH-based (NMDB) IMRT QA framework integrating machine learning (ML) to classify lung SBRT VMAT plans prone to delivery errors
Methods: 560 Eclipse AcurosXB l...

A Pilot Study to Implement a Definitive Breast SBRT Technique

Authors: Charmainne Cruje, Maria Dumol, Nawroz Fatima, Marisa Finlay, Kalaina Johnson, Raman Mohla, Jasleen Uppal

Affiliation: Trillium Health Partners, Carlo Fidani Regional Cancer Centre

Abstract Preview: Purpose: To evaluate the robustness of a breast SBRT protocol in achieving target coverage by utilizing online- and retrospectively-matched CBCT-to-CT images.
Methods: The first pilot patient was s...

Assessing Mlc Errors and Their Dosimetric Impact Delivered on Elekta Linear Accelerator from Two TPS Systems

Authors: Richard Lesieur, Olivia Magneson, David E. Solis, Sotirios Stathakis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: This study evaluates the deliverability and precision of multileaf collimator (MLC) positioning in treatment plans generated by two different Treatment Planning Systems (TPS), Monaco and Pinn...

Checking of Sensitivity of Volumetric Modulated Arc Therapy Quality Assurance System with a Cavity Generation Method

Authors: Kaile Li, Esmail Parsai

Affiliation: Alexander T. Augusta Military Medical Center, Alexander T. Augusta Miliary Medical Center

Abstract Preview: Purpose: To evaluate the sensitivity of the portal dosimetry system with the Arc CHECK system at identical Volumetric Modulated Arc Therapy (VMAT) setup
Methods: An Arc CHECK system from Sun Nuclea...

Clinical Implementation of Volumetric Modulated Arc Therapy (VMAT) for Total Body Irradiation (TBI) with Off-the-Shelf Tools

Authors: Kai-Cheng Chuang, Oana I. Craciunescu, Christopher Kelsey, Joseph Kowalski, Nicole Larrier, Xinyi Li, Sheridan G. Meltsner, Anna E. Rodrigues, Yang Sheng, Qiuwen Wu

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: To clinically implement a Volumetric Modulated Arc Therapy (VMAT) procedure for Total Body Irradiation (TBI) with off-the-shelf tools.
Methods: Patient is treated on linac couch with a hyb...

Designing Impactful Radiotherapy Training for Skill Development and Long-Term Growth

Authors: Stephanie Bennett, Sean L. Berry, Caroline M. Colbert, Dustin J. Jacqmin, James A. Kavanaugh, Minsun Kim, Maura L. Kirk, Emily Kruse, Benjamin Li, Mu-Han Lin, Lindsey A. Olsen, Jose Carlos Pichardo, Justin R. Roper, Leah K. Schubert, Chunhao Wang, Sua Yoo

Affiliation: University of Wisconsin, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiation & Cellular Oncology, University of Chicago, Abington - Jefferson Health, Mayo Clinic, University of Washington, University of Colorado Health, University of Colorado Denver, Department of Radiation Oncology, University of Washington and Fred Hutch Cancer Center, Duke University, Pichardo Physics LLC, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: As clinics in lower- and middle-income countries (LMICs) transition to advanced radiotherapy techniques like IMRT and VMAT, gaps in training can result in suboptimal planning. To help support...

Development of a Novel 3D-Printed Heterogeneous Phantom for Liver SBRT Dose Verification in Hepatocellular Carcinoma (HCC) Treatment.

Authors: Dr. Sheaka Alobaidli, Anju K V, Dr. Chiranjib Konar, Sreejesh MS, Dr. Vijayaprabhu N, Dr. Deepti Sharma, Dr. Hanuman Prasad Yadav

Affiliation: Amity Institute of Applied Sciences, Kuwait Cancer Control Center, Institute of Liver and Biliary Sciences, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Amity institute of Applied Sciences, Amity University, Institute of Liver and Biliary Sciences(ILBS)

Abstract Preview: Purpose:
The accuracy of dose delivery in stereotactic body radiotherapy (SBRT) is critical for effectively treating hepatocellular carcinoma (HCC). This study aims to develop patient-specific 3D-p...

Differential Hole-Size Lattice Patterns for Escalating SFRT Dose to Large, Deep-Seated, and Unresectable Masses

Authors: Joshua Misa, Damodar Pokhrel, William St. Clair

Affiliation: University of Kentucky, Department of Radiation Medicine

Abstract Preview: Purpose: Development of a novel spatially fractionated radiotherapy (SFRT) lattice deployment method featuring a large high-dose sphere at the tumor’s center, surrounded by smaller diameter spheres. W...

Dosimetric Evaluation of a Helical Tomotherapy to L-Shaped Linac Plan Conversion Workflow

Authors: Megan E. Daly, Ryan D. Hernandez, Abriel J. Horak, Soo Kyoung Kim, Peter C. Park, Dwaine O. Spence, Payton H. Stone, Cari L. Wright

Affiliation: UC Davis Cancer Center

Abstract Preview: Purpose: To evaluate a fallback planning workflow used for cross-modality treatment planning and delivery between helical Tomotherapy and volumetric modulated arc therapy (VMAT) using conventional L-s...

Dynamic Angular Couch Kinematics in Radiotherapy

Authors: Eva Lee, R. Lee MacDonald, Alasdair Syme, Christopher G. Thomas

Affiliation: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health, Dalhousie University, Nova Scotia Health

Abstract Preview: Purpose:
Dynamic couch rotation in radiotherapy offers dosimetric benefits, however patient comfort remains a concern. This study investigates couch kinematics in trajectory-based radiotherapy plan...

Evaluating the Interchangeability of Two Similar but Not Beam-Matched Varian Truebeam Linear Accelerators in the Delivery of Patient-Specific Quality Assurance

Authors: Elizabeth M. Alves, Alistair K. Templeton, Julius V. Turian

Affiliation: Rush University Medical Center

Abstract Preview: Purpose: To test the performance of two similar, but not beam-matched, linacs in interchangeably delivering IMRT and VMAT patient-specific quality assurance (PSQA) tests.
Methods: Two TrueBeam lina...

Exploring the Compatibility of VMAT and Respiratory Beam Gating on MR-Linac: A Proof-of-Concept Study

Authors: Caiden Atienza, Pim T. S. Borman, Martin F. Fast, Daniel E. Hyer, Bas W. Raaymakers, Jeffrey E. Snyder, Prescilla Uijtewaal, Peter Woodhead

Affiliation: Department of Radiotherapy, University Medical Center Utrecht, Yale New Haven Health, University of Iowa

Abstract Preview: Purpose:
On conventional C-arm linacs, VMAT is the preferred delivery modality due to its superior efficiency and highly conformal dose distributions. MR-linacs offer superior soft-tissue imaging t...

Feasibility Study of Ethos Artificial-Intelligence Online Adaptive Prostate SBRT

Authors: Miguel Albaladejo, Ana Corbalan, Aitor Ortega, Vicente Puchades, David Ramos, Alfredo Serna-Berna, Jonattan Suarez

Affiliation: Hospital General Universitario Santa Lucia

Abstract Preview: Purpose:
Prostate SBRT treatments are frequently delivered using standard VMAT IGRT technique. The aim of this study is to test the feasibility of Ethos Artificial Intelligence (AI) prostate SBRT b...

Free-Breathing VMAT and IMRT Versus Deep Inspiration Breath- Hold 3D-CRT Techniques for Left-Breast Cancer: A Practical Solution for Developing Countries

Authors: Md. Yousuf Ali, Parvin Akhter Banu, Ehteshamul Hoque, Qazi Mushtaq Hussain, Md Jobairul Islam, Md. Abdul Mannan, Sadia Afrin Sarah, Mostafa Aziz Sumon, Ahammad Al Mamun Sweet, AFM Kamal Uddin

Affiliation: Labaid Cancer Hospital & Superspeciality Centre

Abstract Preview: Purpose: Radiotherapy for left-sided breast cancer can induce cardiac injury. Deep Inspiration Breath Hold (DIBH) is a technique that minimizes cardiac exposure during treatment. This study compares d...

Impact of Mlc and Collimator Errors in Psqa Techniques for VMAT Breast Treatment Plans

Authors: Maria Jose Almada, Oscar Apaza, Carlos Bohorquez, Ezequiel Cabrera, Rogelio Diaz Moreno, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger

Affiliation: LAP, FaMAF, UNC, Instituto Zunino - Fundacion Marie Curie

Abstract Preview: Purpose:
PSQA employs gamma analysis to verify the planned versus delivered dose. Evaluating the effectiveness of PSQA techniques in identifying errors is crucial. This study aims to incorporate ML...

Impact of Source-to-Imager Distance on Patient-Specific Quality Assurance Using Epid

Authors: Hajee Reyaz Ali Sahib, Sangeeta Hazarika, Muthukumaran Manavalan, Jaswin Raj, Daya Nand Sharma, Seema Sharma, Subramani Vellaiyan

Affiliation: AIIMS NCI Jhajjar, PTW North America Corporation, All India Institute of Medical Sciences

Abstract Preview: Purpose:
Purpose is to investigate the effect of extended source-to-imager distances (SID) on the resolution of VMAT patient-specific quality assurance (PSQA) in portal dosimetry (PD).
Methods:<...

Influence of Intrafraction Motion on the Dosimetry of Prostate Treatments

Authors: María Fernández, Inés Flores, Nuria Montero, Manuel Ruiz, Francisco San Miguel

Affiliation: Hospital Central de la Defensa 'Gómez Ulla', Hospital Central de la Defensa "Gomez Ulla", CSVE, Hospital Central de la Defensa 'Gómez Ulla', CSVE

Abstract Preview: Purpose:
During external radiotherapy treatments in the prostate, there can be PTV movements between fractions and during each treatment fraction. In a typical prostate treatment in our institution...

Planning and Delivering Homogenous Dose to Craniospinal Irradiation on Linear Accelerator

Authors: Issra Rashed, Jennie Wilder, Jingeng Zhu

Affiliation: Rush Riverside Cancer Institute, Advanced Oncology Solutions (AOS) Varian, a Siemens Healthineers company

Abstract Preview: Purpose: Develop a method to plan and deliver homogeneous dose to Craniospinal(CS) irradiation on Linear Accelerator.
Methods: Three treatment planning volumes (PTV) are created in sequence from su...

Presenting a Novel Treatment Scheme for Debulking Unresectable Large Tumors: Feasibility, Safety and Patient Reported Early Clinical Outcomes of SBRT Immediately Post-Spatially Fractionated Radiotherapy Delivery

Authors: James Knight II, Joshua Misa, Damodar Pokhrel, William St Clair, Eddy S Yang

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Highly-heterogenous sieve-like dose distribution via SFRT to large/bulky tumors (≥6 cm) could enhance tumor cell-death via both direct/indirect cell-kill mechanisms. Adding highly-conformal S...

Quantification of Wet Towel As Bolus on Skin Dose for VMAT Partial Breast Irradiation

Authors: Haiqa Arain, Ping Xia, Zhexuan Zhang

Affiliation: Cleveland Clinic

Abstract Preview: Purpose: To quantify water contents and thickness of wet towel (as a flexible bolus) on curved surface dose for partial breast irradiation.

Methods: Two VMAT partial breast plans (3000 cGy in 5...

Retrospective Comparison of Treatment Plan Quality As a Function of Delivery Time for SBRT Thoracic Tumors

Authors: Danielle Renee Daiger, Nicholas N. Sperling

Affiliation: University of Toledo, University of Toledo Medical Center

Abstract Preview: Purpose:
To retrospectively evaluate the impact of planned delivery time on plan quality metrics for breath-hold VMAT SBRT thoracic cancer patients.
Methods:
Patients treated for SBRT thoraci...

Stereotactic Body Radiosurgery for Refractory Ventricular Tachycardia: Presenting Efficient Clinic Workflow, Dosimetric Analysis and Patients Reported Clinical Results

Authors: Karam Ayoub, Aaron B Hesselson, Ronald C McGarry, Joshua Misa, Damodar Pokhrel

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Cardiology

Abstract Preview: Purpose: Noninvasive stereotactic body radiosurgery (SBRS) is emerging treatment option for advanced heart failure patients with refractory-ventricular tachycardia (rVT) who experienced recurrent impl...

The Feasibility of Ethos-Based Pulsed Reduced Dose-Rate (PRDR) Radiotherapy

Authors: Chia-Lung Chien, Renteng Hou, Wen C. Hsi, Faraz Kalantari, Ganesh Narayanasamy, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
PRDR is an effective re-irradiation treatment for patients who have already reached the tolerance dose to their organs at risk (OARs). While PRDR is implemented on TrueBeam by limiting the...

Treatment Plan Comparisons of Head and Neck Cancers on Varian Ethos/Halcyon and Truebeam Linac

Authors: Yunfeng Cui, Joseph P. Kowalski, Qiuwen Wu, Yibo Xie

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: A Varian Ethos/Halcyon linac was recently commissioned in our clinic and was used to treat head and neck cancer patients. The purpose of this study is to compare treatment plan quality and de...

Utilization of Log File Analysis to Determine Deliverability of VMAT Plans As a Function of Plan Complexity

Authors: Jameson T. Baker, Sean T Grace, Cindy Pham, Michael A. Trager

Affiliation: Northwell

Abstract Preview: Purpose:
In VMAT planning, increasing complexity in MLC motion and modulation may improve dose distributions and OAR sparing while maintaining PTV coverage. However, increasing complexity can creat...

Volumetric-Modulated Arc Therapy (VMAT) Is Associated with Improved Dose Homogeneity, but More Normal Tissue Irradiation Compared to Three-Dimensional Conformal Radiation Therapy (3DCRT) for Breast Cancer

Authors: Laura I. Cervino, Linda X. Hong, Jessica Pagan, Angelica A. Perez-Andujar, Maria Thor

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center, Memorial Sloan-Kettering Cancer Center

Abstract Preview: Purpose: Three-dimensional conformal radiotherapy (3DCRT) and Volumetric-Modulated Arc Therapy (VMAT) are used to treat locally advanced breast cancer. The 3DCRT treatment plans use the treatment fiel...

When Protons Are Unavailable: Study of High Quality Knowledge-Based Planning Models for the Treatment of Unilateral Head and Neck Patients

Authors: Kenny Guida, Daniel Johnson, Wesley Tucker

Affiliation: University of Kansas Medical Center, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) has emerged as a standard of care for unilateral head and neck (HN) cancers due to superior OAR sparing. With the increase of proton centers national...