Search Submissions 🔎

Results for "vmat delivery": 48 found

A Comparison of Segment-By-Segment Versus Cumulative Signal Evaluation for Patient-Specific QA Using the Integral Quality Monitor

Authors: John J. DeMarco, Farideh Pak, Olivia Grahm C Valadie

Affiliation: Cedars Sinai, Cedars-Sinai, Cedars-Sinai Medical Center

Abstract Preview: Purpose: To investigate the performance of the Integral Quality Monitor (IQM) device for patient-specific QA, focusing on segment-by-segment signal evaluation compared to cumulative signal evaluation....

A Method to Check the Consistency and Reproducibility of VMAT Delivery

Authors: Chloe Doen Kim, Patricia E. Lindsay, Bern Norrlinger, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, Queen's University, Princess Margaret Cancer Centre

Abstract Preview: Purpose: To propose a method to check the consistency of VMAT delivery on linear accelerator (LINAC) with a commercial three-dimensional array device. The method is insensitive to the correction facto...

A Modified VMAT Technique for the Treatment of Diffuse and Extensive Involvement of the Skull By Various Malignancies

Authors: Edward D. Brandner, Weihua Fu, M. Saiful Huq, Ronald John Lalonde, Kiran Mehta, Hima Bindu Musunuru, Yongqian Zhang

Affiliation: UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, University of Pittsburgh School of Medicine and UPMC Hillman CancerCenter

Abstract Preview: Purpose: Treatment of diffuse and extensive involvement of the skull by malignancy presents a difficult challenge for radiation therapy. This study reports preliminary experience of a modified volumet...

A Multi-Criteria Optimization Method Based on Reinforcement Learning and Adaptive Boosting in Radiation Therapy

Authors: Liqin HU, Tao He, Jing JIA, Pengcheng LONG, Wei Meng, Yang Yuan

Affiliation: SuperAccuracy Science & Technology Co. Ltd.

Abstract Preview: Purpose: A multi-criteria optimization method based on reinforcement learning and adaptive boosting(RLAB MCO) has been developed to enhance radiotherapy plan quality by offering reasonable and effecti...

A Novel Non-Measured and DVH-Based IMRT QA Framework with Machine Learning for Instant Classification of Susceptible Lung SBRT VMAT Plans

Authors: Chuan He, Anh H. Le, Iris Z. Wang

Affiliation: Roswell Park Comprehensive Cancer Center, Cedars-Sinai

Abstract Preview: Purpose: To develop a non-measured and DVH-based (NMDB) IMRT QA framework integrating machine learning (ML) to classify lung SBRT VMAT plans prone to delivery errors
Methods: 560 Eclipse AcurosXB l...

A Pilot Study to Implement a Definitive Breast SBRT Technique

Authors: Charmainne Cruje, Maria Dumol, Nawroz Fatima, Marisa Finlay, Kalaina Johnson, Raman Mohla, Jasleen Uppal

Affiliation: Trillium Health Partners, Carlo Fidani Regional Cancer Centre

Abstract Preview: Purpose: To evaluate the robustness of a breast SBRT protocol in achieving target coverage by utilizing online- and retrospectively-matched CBCT-to-CT images.
Methods: The first pilot patient was s...

Benefits on Respiratory Gating Delivery of Lung SBRT

Authors: Andrew Huang, Jonathan Huang, Andrew S Kennedy, Ellie Grace Kong, Ajay Zheng

Affiliation: New York Proton Center, Centennial Medical Center, Executive Medical Physics Associates, Sarah Cannon Cancer Institute, Belmont University

Abstract Preview: Purpose:
Lung stereotactic body radiotherapy (SBRT) is the standard of care for early-stage lung cancer. Respiratory phase gating can be applied to mitigate motion-induced effects. The purpose of t...

Checking of Sensitivity of Volumetric Modulated Arc Therapy Quality Assurance System with a Cavity Generation Method

Authors: Kaile Li, Esmail Parsai

Affiliation: Alexander T. Augusta Military Medical Center, Alexander T. Augusta Miliary Medical Center

Abstract Preview: Purpose: To evaluate the sensitivity of the portal dosimetry system with the Arc CHECK system at identical Volumetric Modulated Arc Therapy (VMAT) setup
Methods: An Arc CHECK system from Sun Nuclea...

Commissioning a Comprehensive Workflow for VMAT Total Body Irradiation (TBI) Using Publicly and Commercially Available Resources

Authors: Alan H. Baydush, Sarah Cummings, Jeffrey Michael Fenoli, Christy Hickerson, Lalith Kumaraswamy, Philmo Oh, Sarah B. Wisnoskie

Affiliation: Novant Health Cancer Institute, Novant Health

Abstract Preview: Purpose: To develop, validate, and commission a VMAT Total Body Irradiation (TBI) workflow by integrating publicly available resources, commercial solutions, and in-house testing to enhance treatment ...

Contingency Planning for Left-Sided Breast Radiation Treatment Using Breath-Hold Technique with Different Delivery Methods

Authors: Nrusingh C. Biswal, Sally Cheston, Sung-Woo Lee, Weiguang Yao, Baoshe Zhang

Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine

Abstract Preview: Purpose: The deep inspiration breath-hold (DIBH) technique in left breast radiation reduces doses to critical organs such as the heart, left lung, and left anterior descending artery (LAD). With the a...

Creation of Customized Workflows in a New Surface-Guided Radiation Therapy (SGRT) System

Authors: Sorour Hosseini, YuHuei Jessica Huang, Jeremy Kunz, Nicholas Pierre Nelson, Ryan G. Price, Prema Rassiah, Hui Zhao

Affiliation: University of Utah, Department of Radiation Oncology, Huntsman Cancer Institute, University of Utah

Abstract Preview: Purpose: To investigate the feasibility and clinical implications of creating customized workflows in a new SGRT system: LUNA 3D (LAP, Florida).
Methods: Three clinical SGRT workflows were designed...

Development and Clinical Validation of Hyperarc Stereotactic Radiosurgery Method for Intraocular Tumors

Authors: Chase Cochran, Damodar Pokhrel, William St Clair

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Currently, intraocular disease is primarily treated via COMS-plaques brachytherapy. Various stereotactic approaches via photons/proton beam have also been implemented (CyberKnife/GammaKnife/p...

Development of a Novel 3D-Printed Heterogeneous Phantom for Liver SBRT Dose Verification in Hepatocellular Carcinoma (HCC) Treatment.

Authors: Dr. Sheaka Alobaidli, Anju K V, Dr. Chiranjib Konar, Sreejesh MS, Dr. Vijayaprabhu N, Dr. Deepti Sharma, Dr. Hanuman Prasad Yadav

Affiliation: Amity Institute of Applied Sciences, Kuwait Cancer Control Center, Institute of Liver and Biliary Sciences, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Amity institute of Applied Sciences, Amity University, Institute of Liver and Biliary Sciences(ILBS)

Abstract Preview: Purpose:
The accuracy of dose delivery in stereotactic body radiotherapy (SBRT) is critical for effectively treating hepatocellular carcinoma (HCC). This study aims to develop patient-specific 3D-p...

Differential Hole-Size Lattice Patterns for Escalating SFRT Dose to Large, Deep-Seated, and Unresectable Masses

Authors: Joshua Misa, Damodar Pokhrel, William St. Clair

Affiliation: University of Kentucky, Department of Radiation Medicine

Abstract Preview: Purpose: Development of a novel spatially fractionated radiotherapy (SFRT) lattice deployment method featuring a large high-dose sphere at the tumor’s center, surrounded by smaller diameter spheres. W...

Dosimetric Evaluation of Enhanced Dynamic Leaf Gap Modeling in Small-Field Clinical Plans: A Verification Study

Authors: Ian J. Butterwick, Sumudu Katugampola, ChangSeon Kim, Evan G. Meekins, Zhengdong Zhang

Affiliation: Mount Sinai Beth Israel, Gesinger Medical Center, Geisinger Medical Center

Abstract Preview: Purpose: To evaluate the dosimetric impact of enhanced dynamic leaf gap (EDLG) modeling in Eclipse V18.0 on small-field dosimetry within VMAT plans.
Methods: Plans with small fields (1 cm x 1 cm to...

Dosimetric Evaluation of a Helical Tomotherapy to L-Shaped Linac Plan Conversion Workflow

Authors: Megan E. Daly, Ryan D. Hernandez, Abriel J. Horak, Soo Kyoung Kim, Peter C. Park, Dwaine O. Spence, Payton H. Stone, Cari L. Wright

Affiliation: UC Davis Cancer Center

Abstract Preview: Purpose: To evaluate a fallback planning workflow used for cross-modality treatment planning and delivery between helical Tomotherapy and volumetric modulated arc therapy (VMAT) using conventional L-s...

Dosimetric Impact of Target Coverage with Inter-Fraction Patient Yaw Setup Error in IMRT/VMAT Prostate Cancer Radiotherapy

Authors: Min Su

Affiliation: Mount Sinai School of Medicine

Abstract Preview: Purpose: To evaluate dosimetric impact of patient setup yaw error to target coverage for pelvis/prostate radiation external beam IMRT-VMAT treatment.
Methods: 9 Pelvis/prostate IMRT-VMAT treatment ...

Dynamic Angular Couch Kinematics in Radiotherapy

Authors: Eva Lee, R. Lee MacDonald, Alasdair Syme, Christopher G. Thomas

Affiliation: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health, Dalhousie University, Nova Scotia Health

Abstract Preview: Purpose:
Dynamic couch rotation in radiotherapy offers dosimetric benefits, however patient comfort remains a concern. This study investigates couch kinematics in trajectory-based radiotherapy plan...

Dynamic Winston-Lutz Testing for FFF Beams

Authors: Cambridge L Bui-Nguyen, Alexander S. Nguyen, Liqiang (Lee) Tao

Affiliation: Varian AOS @Epic Care, UC Berkeley

Abstract Preview: Purpose: Dynamic Winston-Lutz (WL) testing provides a comprehensive framework for evaluating the accuracy of isocenter alignment. This study investigates the impact of dynamic beam modulation, such as...

Enhancing the Capability of Intrafractional Target Tracking for Prostate SBRT Via Tissue Decomposition Imaging

Authors: Sarah Burleson, Antonio L. Damato, Yabo Fu, Laura Happersett, Tianfang Li, Xiang Li, Himanshu Nagar, Pengpeng Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: An iodinated hydrogel perirectal spacer, injected between the prostate and rectum, reduces rectal high-dose exposure during prostate SBRT. We assessed the feasibility of tracking the spacer a...

Evaluating the Interchangeability of Two Similar but Not Beam-Matched Varian Truebeam Linear Accelerators in the Delivery of Patient-Specific Quality Assurance

Authors: Elizabeth M. Alves, Alistair K. Templeton, Julius V. Turian

Affiliation: Rush University Medical Center

Abstract Preview: Purpose: To test the performance of two similar, but not beam-matched, linacs in interchangeably delivering IMRT and VMAT patient-specific quality assurance (PSQA) tests.
Methods: Two TrueBeam lina...

Evaluation of Hybrid Dynamic Conformal Arc Planning for SRS and SBRT Treatment

Authors: Pat Esposito, Ashley Klein, Carmine Verna, Ling Zhuang

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: To evaluate dosimetric parameters and treatment delivery efficiency between volumetric modulated arc therapy (VMAT) and hybrid dynamic conformal arc (HDCA) on SRS and SBRT planning through st...

Evaluation of Plan Quality and Optimal Isocenter Arrangement for Total Marrow and Lymphoid Irradiation on a Ring-Gantry Linac with Dual-Layer Mlc Using the Knowledge-Based Planning Technique

Authors: Chunhui Han, An Liu, Anthony Magliari, Lesley Rosa

Affiliation: Office of Medical Affairs, Varian, A Siemens Healthineers Company, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: To evaluate the performance of a knowledge-based planning (KBP) optimization model for total marrow and lymphoid irradiation (TMLI) on a ring-gantry linac with a dual-layer MLC and to evaluat...

Exploring the Compatibility of VMAT and Respiratory Beam Gating on MR-Linac: A Proof-of-Concept Study

Authors: Caiden Atienza, Pim T. S. Borman, Martin F. Fast, Daniel E. Hyer, Bas W. Raaymakers, Jeffrey E. Snyder, Prescilla Uijtewaal, Peter Woodhead

Affiliation: Department of Radiotherapy, University Medical Center Utrecht, Yale New Haven Health, University of Iowa

Abstract Preview: Purpose:
On conventional C-arm linacs, VMAT is the preferred delivery modality due to its superior efficiency and highly conformal dose distributions. MR-linacs offer superior soft-tissue imaging t...

Feasibility of Rapidarc Dynamic for Lattice Radiation Therapy of Bulky Liver Tumors

Authors: Christine V. Chung, Laurence Edward Court, Meena S. Khan, Ethan B. Ludmir, Rachael M. Martin Paulpeter, Saurabh Shashikumar Nair, Callistus M. Nguyen, Joshua S. Niedzielski, Luis Augusto Perles

Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Spatially Fractionated Radiation Therapy (SFRT) has re-emerged as an efficacious treatment approach for bulky solid tumors. RapidArc Dynamic (RAD) has unique beam delivery capabilities that m...

Functional MRI Guided Partial Tumor Irradiation to Improve Tumor Control and Spare Tumor Microenvironment

Authors: Bingqi Guo, Ping Xia

Affiliation: Cleveland Clinic

Abstract Preview: Purpose:
Spatially fractionated radiation therapy (SFRT) delivers a “GRID” or “lattice” of high and low doses to tumors to increase tumor control, minimize normal tissue damage, and preserve the im...

High-Fidelity Treatment Optimization for Online Adaptive Stereotactic Partial Breast Irradiation: Integrating Dose and Treatment Time Considerations

Authors: Drexell Hunter Boggs, Carlos E. Cardenas, Jingwei Duan, Joseph Harms, Joel A. Pogue, Richard A. Popple, Courtney Bosse Stanley, Dennis N. Stanley, Sean Xavier Sullivan, Natalie N. Viscariello

Affiliation: Washington University in St. Louis, The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: CBCT-guided online adaptive radiation therapy (OART) with Ethos for stereotactic accelerated partial breast irradiation (APBI) can mitigate inter-fraction variation, leading to dosimetric adv...

Impact of Mlc and Collimator Errors in Psqa Techniques for VMAT Breast Treatment Plans

Authors: Maria Jose Almada, Oscar Apaza, Carlos Bohorquez, Ezequiel Cabrera, Rogelio Diaz Moreno, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger

Affiliation: LAP, FaMAF, UNC, Instituto Zunino - Fundacion Marie Curie

Abstract Preview: Purpose:
PSQA employs gamma analysis to verify the planned versus delivered dose. Evaluating the effectiveness of PSQA techniques in identifying errors is crucial. This study aims to incorporate ML...

Impact of Source-to-Imager Distance on Patient-Specific Quality Assurance Using Epid

Authors: Hajee Reyaz Ali Sahib, Sangeeta Hazarika, Muthukumaran Manavalan, Jaswin Raj, Daya Nand Sharma, Seema Sharma, Subramani Vellaiyan

Affiliation: AIIMS NCI Jhajjar, PTW North America Corporation, All India Institute of Medical Sciences

Abstract Preview: Purpose:
Purpose is to investigate the effect of extended source-to-imager distances (SID) on the resolution of VMAT patient-specific quality assurance (PSQA) in portal dosimetry (PD).
Methods:<...

Investigating the Effect of Beam Flattening Filter on Dose Estimated with Varian’s Original and Enhanced Mlc Models

Authors: Kenny Guida, Hongyu Jiang, Harold Li, Hem Bahadur Moktan Tamang

Affiliation: University of Nebraska Medical Center, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Varian Eclipse v18.0 introduced Enhanced Leaf Model (ELM) of MLC, which provides better dose calculation accuracy than original DLG-based MLC model. The leaf-gap (LG) parameter for ELM repres...

Investigation of Triggered Imaging and Auto Beam Hold Using a Dynamic Thorax Phantom for Intra-Fraction Motion Management

Authors: Liu Hong, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose: During treatment delivery on TrueBeam platform 2.7, Triggered Imaging (TI) enables kV images acquisition at regular intervals and Auto Beam Hold (ABH) provides beam pausing if the target is m...

Knowledge-Based Deep Residual U-Net for Synthetic CT Generation Using a Single MR Volume for Frameless Radiosurgery

Authors: Justus Adamson, John Ginn, Yongbok Kim, Ke Lu, Trey Mullikin, Xiwen Shu, Chunhao Wang, Zhenyu Yang, Jingtong Zhao

Affiliation: Duke University, Duke Kunshan University

Abstract Preview: Purpose:
To develop a knowledge-based deep model for synthetic CT (sCT) generation from a single MR volume in frameless radiosurgery (SRS), eliminating the need for CT simulation prior to the SRS d...

Patient-Specific Bio-Morphological Features in Cherenkov Imaging for Positioning Verification: A Retrospective Analysis in Accelerated Partial Breast Irradiation (aPBI) VMAT Radiotherapy

Authors: Yao Chen, Lesley A Jarvis, Allison Matous, Rongxiao Zhang

Affiliation: Dartmouth College, University of Missouri, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose: Precise patient positioning is critical in accelerated partial breast irradiation (aPBI) to ensure accurate dose delivery to the tumor bed while minimizing exposure to surrounding healthy tis...

Planning and Delivering Homogenous Dose to Craniospinal Irradiation on Linear Accelerator

Authors: Issra Rashed, Jennie Wilder, Jingeng Zhu

Affiliation: Rush Riverside Cancer Institute, Advanced Oncology Solutions (AOS) Varian, a Siemens Healthineers company

Abstract Preview: Purpose: Develop a method to plan and deliver homogeneous dose to Craniospinal(CS) irradiation on Linear Accelerator.
Methods: Three treatment planning volumes (PTV) are created in sequence from su...

Presenting a Novel Treatment Scheme for Debulking Unresectable Large Tumors: Feasibility, Safety and Patient Reported Early Clinical Outcomes of SBRT Immediately Post-Spatially Fractionated Radiotherapy Delivery

Authors: James Knight II, Joshua Misa, Damodar Pokhrel, William St Clair, Eddy S Yang

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Highly-heterogenous sieve-like dose distribution via SFRT to large/bulky tumors (≥6 cm) could enhance tumor cell-death via both direct/indirect cell-kill mechanisms. Adding highly-conformal S...

Real-Time Automatic Treatment Planning System (RT-AutoTPS) for Volumetric Modulated Arc Radiotherapy (VMAT)

Authors: Steve B. Jiang, Austen Matthew Maniscalco, Dan Nguyen, Chenyang Shen, Jiacheng Xie, Shunyu Yan, Ying Zhang, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Although treatment planning systems (TPSs) can handle dose calculation and plan optimization automatically, planning for radiotherapy still requires extensive efforts and expertise from a mul...

Retrospective Comparison of Treatment Plan Quality As a Function of Delivery Time for SBRT Thoracic Tumors

Authors: Danielle Renee Daiger, Nicholas N. Sperling

Affiliation: University of Toledo, University of Toledo Medical Center

Abstract Preview: Purpose:
To retrospectively evaluate the impact of planned delivery time on plan quality metrics for breath-hold VMAT SBRT thoracic cancer patients.
Methods:
Patients treated for SBRT thoraci...

Retrospective Study Using Avi Planner for Head and Neck Cancer Cases: Our Experience at Nsia-Luth Cancer Center, South - West Nigeria

Authors: Adebayo Abe, Samuel Olaolu Adeneye, Eben Aje, Bidemi I. Akinlade, Inioluwa Damilola Ariyo, Lilian Ekpo, Muhammad Habeebu, Adedayo O. Joseph, Charles S. Mayo, Noah Ndianaobong, Ikechi S Ozoemelam, Margaret Dideolu Taiwo, Godwin Uwagba

Affiliation: University of Michigan, University of Ibadan, University of Lagos, Missouri University of Science and Technology, NSIA-LUTH Cancer Center, University of Lagos, NSIA-LUTH Cancer Centre, NSIA-LUTH Cancer Center

Abstract Preview: Purpose:
Head and neck cancers (HNC) present significant challenges in radiotherapy due to complex anatomy and the proximity to critical organs at risk (OARs). These challenges are compounded in na...

Robustness Enhancement for VMAT-TBI Planning and Treatment Delivery

Authors: Courtney R. Buckey, Quan Chen, Suzanne J. Chungbin, Edward L. Clouser, Yi Rong, Jun Tan, Jennifer Yan, Xiang Sheng Yan

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose:
To identify planning techniques that consistently result in robust VMAT-TBI plans that allow for larger patient setup errors.
Methods:
Conventional planning method often results in p...

Stereotactic Body Radiosurgery for Refractory Ventricular Tachycardia: Presenting Efficient Clinic Workflow, Dosimetric Analysis and Patients Reported Clinical Results

Authors: Karam Ayoub, Aaron B Hesselson, Ronald C McGarry, Joshua Misa, Damodar Pokhrel

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Cardiology

Abstract Preview: Purpose: Noninvasive stereotactic body radiosurgery (SBRS) is emerging treatment option for advanced heart failure patients with refractory-ventricular tachycardia (rVT) who experienced recurrent impl...

The Feasibility of Ethos-Based Pulsed Reduced Dose-Rate (PRDR) Radiotherapy

Authors: Chia-Lung Chien, Renteng Hou, Wen C. Hsi, Faraz Kalantari, Ganesh Narayanasamy, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
PRDR is an effective re-irradiation treatment for patients who have already reached the tolerance dose to their organs at risk (OARs). While PRDR is implemented on TrueBeam by limiting the...

Time-Resolved CBCT: A Novel Solution for Motion Management

Authors: Bulent Aydogan, Xiaochuan Pan, Erik Pearson, Zheng Zhang

Affiliation: The University of Chicago

Abstract Preview: Purpose: Motion management remains one of the significant challenges in external beam radiation therapy (RT). We are developing time-resolved cone-beam computed tomography (trCBCT) for imaging during ...

Total Body Irradiation Using Field-in-Field Treatment Planning Techniques

Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West

Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma

Abstract Preview: Purpose: To simulate total-body-irradiation (TBI) with field-in-field treatment planning techniques and test portal dosimetry for dose verification and quality assurance.
Methods: CT images of full...

Treatment Machine Matching for ELM in Eclipse v18.0 By Adjusting Physical Leaf Gap

Authors: Quyen Duong, Si Young Jang, Soyoung Lee, Samuel Ming Ho Luk

Affiliation: Boston University, Department of Radiation Oncology, University of Vermont Medical Center, Boston Medical Center

Abstract Preview: Purpose: To investigate the clinical impact of physical MLC gaps changes with Millennium 120 MLC on Enhanced Leaf Modeling (ELM) and patient plans, and to establish a new MLC model in Eclipse v18.0 on...

Treatment Plan Comparisons of Head and Neck Cancers on Varian Ethos/Halcyon and Truebeam Linac

Authors: Yunfeng Cui, Joseph P. Kowalski, Qiuwen Wu, Yibo Xie

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: A Varian Ethos/Halcyon linac was recently commissioned in our clinic and was used to treat head and neck cancer patients. The purpose of this study is to compare treatment plan quality and de...

Treatment Planning System Modelling of a New Commercial Rotational Table

Authors: Michael Armstrong, Courtney R. Buckey, Quan Chen, Suzanne J. Chungbin, Mirek Fatyga, Yi Rong, Jun Tan, Xiang Sheng Yan

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: To model a commercial rotational table in treatment planning system (TPS) for accurate dose optimization and calculation.

Methods: A commercial rotational table (CDR Equilibrium®) is r...

Utilization of Log File Analysis to Determine Deliverability of VMAT Plans As a Function of Plan Complexity

Authors: Jameson T. Baker, Sean T Grace, Cindy Pham, Michael A. Trager

Affiliation: Northwell

Abstract Preview: Purpose:
In VMAT planning, increasing complexity in MLC motion and modulation may improve dose distributions and OAR sparing while maintaining PTV coverage. However, increasing complexity can creat...

VMAT Machine Parameter Optimization Using Policy Gradient Reinforcement Learning

Authors: Avinash Mudireddy, Nathan Shaffer, Joel J. St-Aubin

Affiliation: University of Iowa

Abstract Preview: Purpose: This work demonstrates preliminary results in training a reinforcement learning (RL) network to perform VMAT machine parameter optimization.
Methods: We implemented a policy gradient RL al...