Authors: Shashanksharad Kale, Gopishankar Natanasabapathi, Daya Nand Kishore Sharma
Affiliation: All India Institute of Medical Sciences (AIIMS), Department of Radiation Oncology, All India Institute of Medical Sciences
Abstract Preview: Purpose:
The study demonstrates a novel 3D printing method to fabricate an ion chamber insert (ICI) for absolute dosimetry purpose in gamma knife radiosurgery (GKRS).
Methods:
Our institute u...
Authors: Suman Gautam, Tianjun Ma, William Song
Affiliation: Virginia Commonwealth University
Abstract Preview: Purpose: We propose an artificial intelligence (AI)-based method to rapidly predict the patient-speciļ¬c quality assurance (PSQA) results for magnetic resonance (MR)-guided online adaptive radiation th...
Authors: Edward D. Brandner, Weihua Fu, M. Saiful Huq, Ronald John Lalonde, Kiran Mehta, Hima Bindu Musunuru, Yongqian Zhang
Affiliation: UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, University of Pittsburgh School of Medicine and UPMC Hillman CancerCenter
Abstract Preview: Purpose: Treatment of diffuse and extensive involvement of the skull by malignancy presents a difficult challenge for radiation therapy. This study reports preliminary experience of a modified volumet...
Authors: Liqin HU, Tao He, Jing JIA, Pengcheng LONG, Wei Meng, Yang Yuan
Affiliation: SuperAccuracy Science & Technology Co. Ltd.
Abstract Preview: Purpose: A multi-criteria optimization method based on reinforcement learning and adaptive boosting(RLAB MCO) has been developed to enhance radiotherapy plan quality by offering reasonable and effecti...
Authors: Charmainne Cruje, Maria Dumol, Nawroz Fatima, Marisa Finlay, Kalaina Johnson, Raman Mohla, Jasleen Uppal
Affiliation: Trillium Health Partners, Carlo Fidani Regional Cancer Centre
Abstract Preview: Purpose: To evaluate the robustness of a breast SBRT protocol in achieving target coverage by utilizing online- and retrospectively-matched CBCT-to-CT images.
Methods: The first pilot patient was s...
Authors: Maria Jose Almada, Bruno Forti, Andres Lima, Carlos Daniel Venencia
Affiliation: Instituto Zunino - Fundacion Marie Curie
Abstract Preview: Purpose:
To automate the planning of radiotherapy treatments for bone metastases using a script in the ECLIPSE planning system version 15.6 with a graphical interface.
Methods:
A script was d...
Authors: Maria Jose Almada, Bruno Forti, Patricia Murina, Carlos Daniel Venencia
Affiliation: Instituto Zunino - Fundacion Marie Curie, Dra.
Abstract Preview: Purpose: The use of VMAT for the breast requires duplication of the patient's CT, several planning structures, and patient-specific dose-volume constraints depending on the patient's anatomy, fraction...
Authors: Kai-Cheng Chuang, Oana I. Craciunescu, Christopher Kelsey, Joseph Kowalski, Nicole Larrier, Xinyi Li, Sheridan G. Meltsner, Anna E. Rodrigues, Yang Sheng, Qiuwen Wu
Affiliation: Duke University, Duke University Medical Center
Abstract Preview: Purpose: To clinically implement a Volumetric Modulated Arc Therapy (VMAT) procedure for Total Body Irradiation (TBI) with off-the-shelf tools.
Methods: Patient is treated on linac couch with a hyb...
Authors: Nrusingh C. Biswal, Sally Cheston, Sung-Woo Lee, Weiguang Yao, Baoshe Zhang
Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine
Abstract Preview: Purpose: The deep inspiration breath-hold (DIBH) technique in left breast radiation reduces doses to critical organs such as the heart, left lung, and left anterior descending artery (LAD). With the a...
Authors: Stephanie Bennett, Sean L. Berry, Caroline M. Colbert, Dustin J. Jacqmin, James A. Kavanaugh, Minsun Kim, Maura L. Kirk, Emily Kruse, Benjamin Li, Mu-Han Lin, Lindsey A. Olsen, Jose Carlos Pichardo, Justin R. Roper, Leah K. Schubert, Chunhao Wang, Sua Yoo
Affiliation: University of Wisconsin, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiation & Cellular Oncology, University of Chicago, Abington - Jefferson Health, Mayo Clinic, University of Washington, University of Colorado Health, University of Colorado Denver, Department of Radiation Oncology, University of Washington and Fred Hutch Cancer Center, Duke University, Pichardo Physics LLC, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: As clinics in lower- and middle-income countries (LMICs) transition to advanced radiotherapy techniques like IMRT and VMAT, gaps in training can result in suboptimal planning. To help support...
Authors: Dr. Sheaka Alobaidli, Anju K V, Dr. Chiranjib Konar, Sreejesh MS, Dr. Vijayaprabhu N, Dr. Deepti Sharma, Dr. Hanuman Prasad Yadav
Affiliation: Amity Institute of Applied Sciences, Kuwait Cancer Control Center, Institute of Liver and Biliary Sciences, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Amity institute of Applied Sciences, Amity University, Institute of Liver and Biliary Sciences(ILBS)
Abstract Preview: Purpose:
The accuracy of dose delivery in stereotactic body radiotherapy (SBRT) is critical for effectively treating hepatocellular carcinoma (HCC). This study aims to develop patient-specific 3D-p...
Authors: Minbin Chen, Gang Liu, Manju Liu, Weiwei Sang, Pulin Sun, Mingyuan Ye, Fang-Fang Yin, Lihua Zhang, Haiming Zhu
Affiliation: Jiahui International Hospital, Radiation Oncology, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University, Duke Kunshan University, The First People's Hospital of Kunshan
Abstract Preview: Purpose: This study aims to conduct a dosimetric comparison between lattice radiotherapy (LRT) and 3D grid treatment planning techniques, focusing on their differences in delivering three-dimensional ...
Authors: Awens Alphonse, Nebi Demez, Noufal Manthala Padannayil, Haley Park, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Nishan Shrestha, Somol Sunny
Affiliation: Florida Atlantic University, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida
Abstract Preview: Purpose: This study evaluates the dosimetric effects of patient positioning errors, including setup inaccuracies and yaw deviations, on dual-isocenter volumetric modulated arc therapy (VMAT) plans for...
Authors: Sumanta Manna, Atul Mishra, Surendra Prasad Mishra, Kailash Kumar Mittal, Anoop Kumar Srivastava, Neha Yadav
Affiliation: Department of Radiation Oncology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Department of radiation Oncology, Apollomedics Super Speciality Hospitals, Department of Radiation Oncology, Uttar Pradesh University of Medical Sciences, Department of Radiation Oncology, Kalyan Singh Super Specialty Cancer Institute
Abstract Preview: Purpose: This study aimed to assess the dosimetric performance of Volumetric Modulated Arc Therapy (VMAT), step-and-shoot Intensity-Modulated Radiation Therapy (ss-IMRT), and dynamic Intensity-Modulat...
Authors: Eva Lee, R. Lee MacDonald, Alasdair Syme, Christopher G. Thomas
Affiliation: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health, Dalhousie University, Nova Scotia Health
Abstract Preview: Purpose:
Dynamic couch rotation in radiotherapy offers dosimetric benefits, however patient comfort remains a concern. This study investigates couch kinematics in trajectory-based radiotherapy plan...
Authors: Sarah Burleson, Antonio L. Damato, Yabo Fu, Laura Happersett, Tianfang Li, Xiang Li, Himanshu Nagar, Pengpeng Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: An iodinated hydrogel perirectal spacer, injected between the prostate and rectum, reduces rectal high-dose exposure during prostate SBRT. We assessed the feasibility of tracking the spacer a...
Authors: Chunhui Han, An Liu, Anthony Magliari, Lesley Rosa
Affiliation: Office of Medical Affairs, Varian, A Siemens Healthineers Company, Department of Radiation Oncology, City of Hope National Medical Center
Abstract Preview: Purpose: To evaluate the performance of a knowledge-based planning (KBP) optimization model for total marrow and lymphoid irradiation (TMLI) on a ring-gantry linac with a dual-layer MLC and to evaluat...
Authors: Miguel Albaladejo, Ana Corbalan, Aitor Ortega, Vicente Puchades, David Ramos, Alfredo Serna-Berna, Jonattan Suarez
Affiliation: Hospital General Universitario Santa Lucia
Abstract Preview: Purpose:
Prostate SBRT treatments are frequently delivered using standard VMAT IGRT technique. The aim of this study is to test the feasibility of Ethos Artificial Intelligence (AI) prostate SBRT b...
Authors: Md. Yousuf Ali, Parvin Akhter Banu, Ehteshamul Hoque, Qazi Mushtaq Hussain, Md Jobairul Islam, Md. Abdul Mannan, Sadia Afrin Sarah, Mostafa Aziz Sumon, Ahammad Al Mamun Sweet, AFM Kamal Uddin
Affiliation: Labaid Cancer Hospital & Superspeciality Centre
Abstract Preview: Purpose: Radiotherapy for left-sided breast cancer can induce cardiac injury. Deep Inspiration Breath Hold (DIBH) is a technique that minimizes cardiac exposure during treatment. This study compares d...
Authors: Bingqi Guo, Ping Xia
Affiliation: Cleveland Clinic
Abstract Preview: Purpose:
Spatially fractionated radiation therapy (SFRT) delivers a āGRIDā or ālatticeā of high and low doses to tumors to increase tumor control, minimize normal tissue damage, and preserve the im...
Authors: Wei Luo, Cameron Thayer-Freeman, Yifeng Zhao
Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky
Abstract Preview: Purpose: Real-time Kilovoltage (kV) imaging has emerged as a powerful clinical aid, providing high-precision localization of moving targets during treatment. However, the Megavoltage (MV) treatment be...
Authors: Maria Jose Almada, Oscar Apaza, Carlos Bohorquez, Ezequiel Cabrera, Rogelio Diaz Moreno, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger
Affiliation: LAP, FaMAF, UNC, Instituto Zunino - Fundacion Marie Curie
Abstract Preview: Purpose:
PSQA employs gamma analysis to verify the planned versus delivered dose. Evaluating the effectiveness of PSQA techniques in identifying errors is crucial. This study aims to incorporate ML...
Authors: Andreea Dimofte, Maksym Sharma, Weibing Yang, Timothy C. Zhu
Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania
Abstract Preview: Purpose:
To assess the effectiveness and dosimetric impact of utilizing a knowledge-based planning model for GI site-specific plans.
Methods:
Six knowledge-based planning models were develope...
Authors: MarĆa FernĆ”ndez, InĆ©s Flores, Nuria Montero, Manuel Ruiz, Francisco San Miguel
Affiliation: Hospital Central de la Defensa 'Gómez Ulla', Hospital Central de la Defensa "Gomez Ulla", CSVE, Hospital Central de la Defensa 'Gómez Ulla', CSVE
Abstract Preview: Purpose:
During external radiotherapy treatments in the prostate, there can be PTV movements between fractions and during each treatment fraction. In a typical prostate treatment in our institution...
Authors: Nobuki Imano, Daisuke Kawahara, Akito S Koganezawa, Yuji Murakami, Ikuno Nishibuchi, Takuya Wada
Affiliation: Department of Information and Electronic Engineering, Faculty of Science and Engineering, Teikyo University, Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University
Abstract Preview: Purpose: Adaptive radiotherapy (ART) compensates for treatment plans based on anatomical changes while not considering biological effects such as interruptions during treatment. This study aims to dev...
Authors: Ryan Clark, Jon Cornelisse, Kenny Guida, Anthony Magliari, Lesley Rosa, Megan Smith, Shane R Stecklein
Affiliation: Office of Medical Affairs, Varian, A Siemens Healthineers Company, Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Post-mastectomy radiation therapy (PMRT) can pose a challenge for planners of all levels of experience. For cases where 3D conformal therapy yields undesirable results (i.e., dose heterogenei...
Authors: Kenny Guida, Hongyu Jiang, Harold Li, Hem Bahadur Moktan Tamang
Affiliation: University of Nebraska Medical Center, Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Varian Eclipse v18.0 introduced Enhanced Leaf Model (ELM) of MLC, which provides better dose calculation accuracy than original DLG-based MLC model. The leaf-gap (LG) parameter for ELM repres...
Authors: Justus Adamson, John Ginn, Yongbok Kim, Ke Lu, Trey Mullikin, Xiwen Shu, Chunhao Wang, Zhenyu Yang, Jingtong Zhao
Affiliation: Duke University, Duke Kunshan University
Abstract Preview: Purpose:
To develop a knowledge-based deep model for synthetic CT (sCT) generation from a single MR volume in frameless radiosurgery (SRS), eliminating the need for CT simulation prior to the SRS d...
Authors: Yao Chen, Lesley A Jarvis, Allison Matous, Rongxiao Zhang
Affiliation: Dartmouth College, University of Missouri, Dartmouth Cancer Center, Dartmouth Health
Abstract Preview: Purpose: Precise patient positioning is critical in accelerated partial breast irradiation (aPBI) to ensure accurate dose delivery to the tumor bed while minimizing exposure to surrounding healthy tis...
Authors: Shifeng Chen, Erica Fisler, Arun Gopal, Mariana Guerrero, Jason Hendershot, Kai Huang, Eric Kusmaul, Adam Schrum, Megan Steinberg, Kai Wang
Affiliation: University of Maryland School of Medicine, Department Radiation Oncology, Kaufman Cancer Center, Upper Chesapeake Medical Center, University of Maryland Medical System Central Maryland Radiation Oncology, Department of Radiation Oncology, University of Maryland Medical Center, Baltimore Washington Medical Center Radiation Oncology, Department of Radiation Oncology, University of Maryland School of Medicine
Abstract Preview: Purpose:
Our goal is to develop and clinically deploy an automated planning tool using multicriteria optimization (MCO) for VMAT in prostate only, whole pelvis radiotherapy treatments.
Methods:<...
Authors: Qijie Huang, Gourav Jhanwar, Saad Nadeem, Vicki Trier Taasti, Mojtaba Tefagh, Seppo Tuomaala, Masoud Zarepisheh
Affiliation: Varian Medical Systems Inc, Department of Clinical Medicine - Danish Center for Particle Therapy, Aarhus University Hospital, Memorial Sloan Kettering Cancer Center, The University of Edinburgh
Abstract Preview: Purpose:
We have developed PortPy (Planning and Optimization for Radiation Therapy in Python), a first-of-its-kind open-source package designed to accelerate research and development in radiotherap...
Authors: Piotr Pater, Nicholas G. Zacharopoulos
Affiliation: McGill University, Medical Physics Unit, Gerald Bronfman Department of Oncology, McGill University
Abstract Preview: Purpose: To develop a method for accurate relative film dosimetry that incorporates non-uniformity
corrections.
Methods: The accuracy of Devicās [1] linearization approach was evaluated using si...
Authors: Danielle Renee Daiger, Nicholas N. Sperling
Affiliation: University of Toledo, University of Toledo Medical Center
Abstract Preview: Purpose:
To retrospectively evaluate the impact of planned delivery time on plan quality metrics for breath-hold VMAT SBRT thoracic cancer patients.
Methods:
Patients treated for SBRT thoraci...
Authors: Courtney R. Buckey, Quan Chen, Suzanne J. Chungbin, Edward L. Clouser, Yi Rong, Jun Tan, Jennifer Yan, Xiang Sheng Yan
Affiliation: Mayo Clinic Arizona, Mayo Clinic
Abstract Preview: Purpose:
To identify planning techniques that consistently result in robust VMAT-TBI plans that allow for larger patient setup errors.
Methods:
Conventional planning method often results in p...
Authors: Yijian Cao, Sean T Grace, Marissa Joyce Vaccarelli
Affiliation: Northwell
Abstract Preview: Purpose:
This study investigates the dosimetric efficacy of significantly limiting gantry angles in prostate radiation therapy to as a promising strategy to maintain plan quality while enhancing ma...
Authors: Eric C. Ford, Yulun He, Minsun Kim, Dustin Melancon, Juergen Meyer, Dong Joo Rhee, Yinghua Tao
Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, MD Anderson Cancer Center, University of Washington
Abstract Preview: Purpose: To develop and evaluate an automated-planning technique capable of generating high-quality treatment plans for hippocampal-sparing-whole-brain radiation therapy.
Methods: An auto-planning ...
Authors: Xiu tong Lin
Affiliation: Department of Radiation physics and technology, Shandong Second Provincial General Hospital
Abstract Preview: Purpose: To compare the dosimetric differences between the photon and proton plans and between the different target according to the placement of the implants for patients undergoing radiotherapy afte...
Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West
Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma
Abstract Preview: Purpose: To simulate total-body-irradiation (TBI) with field-in-field treatment planning techniques and test portal dosimetry for dose verification and quality assurance.
Methods: CT images of full...
Authors: Laura I. Cervino, Linda X. Hong, Jessica Pagan, Angelica A. Perez-Andujar, Maria Thor
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center, Memorial Sloan-Kettering Cancer Center
Abstract Preview: Purpose: Three-dimensional conformal radiotherapy (3DCRT) and Volumetric-Modulated Arc Therapy (VMAT) are used to treat locally advanced breast cancer. The 3DCRT treatment plans use the treatment fiel...