Search Submissions 🔎

Results for "volumetric cone": 37 found

A Diffusion-Based AI Framework for Continuous Deformable Image Registration and Time-Resolved Dynamic CT Generation

Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Gregory Szalkowski, Qingying Wang, Kangning Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Respiratory motion management is crucial for accurate radiation delivery to moving targets while protecting healthy tissue, relying on time-resolved volumetric imaging and continuous deformab...

Analysis of Orthopedic Metal Artifact Reduction’s (O-MAR’s) Effectiveness on Correcting Typical Anatomical Structure Average Volumetric Hounsfield Unit (AVHU) Values Due to High-Density Metal Artifacts

Authors: John T Barrett, Mehnaz Haque, Chulhaeng Huh, Shands James, Thomas B. Lavin, Anobel Maghsoodpour, Farshad Mostafaei, Austin Sanders

Affiliation: Department of Radiation Oncology, Augusta University, Department of Radiation Oncology, Medical College of Georgia, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health, Department of Radiation Oncology, Doctors Hospital of Augusta, Department of Radiology and Imaging, Augusta University

Abstract Preview: Purpose: This study assesses Philips’ O-MAR effectiveness in adjusting AVHU values of common anatomical materials affected by various high-density metal artifacts at varying distances.

Methods:...

Assessing Mlc Errors and Their Dosimetric Impact Delivered on Elekta Linear Accelerator from Two TPS Systems

Authors: Richard Lesieur, Olivia Magneson, David E. Solis, Sotirios Stathakis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: This study evaluates the deliverability and precision of multileaf collimator (MLC) positioning in treatment plans generated by two different Treatment Planning Systems (TPS), Monaco and Pinn...

BEST IN PHYSICS IMAGING: Volumetric Sampling Properties of Longitudinal Multiple X-Ray-Source Array Computed Tomography (MXA-CT)

Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski, Huanyi Zhou

Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation

Abstract Preview: Purpose: A new CT configuration utilizing a multiple X-ray-source array (MXA) is under development to mitigate cone-beam (CB) artifacts in single-rotation wide coverage imaging. We investigate the sam...

BEST IN PHYSICS ULTRASOUND: A Calibration Framework for Quantifying Element Misalignment in 2D Matrix Array Transducers Used in 3D Quantitative Ultrasound

Authors: Cristel Baiu, Laura Castaneda Martinez, Ivan M. Rosado-Mendez

Affiliation: University of Wisconsin, Department of Medical Physics, University of Wisconsin-Madison, Departments of Medical Physics and Radiology, University of Wisconsin-Madison

Abstract Preview: Purpose: 2D matrix array transducers (2DMAT) are advancing volumetric ultrasound due to their ability to provide more isotropic 3D resolution, fast volumetric imaging, and highly customizable focusing...

Binary Classification of Lymphedema in 3DCRT Patients Using Machine Learning on 3D Dose Distribution Data

Authors: Jee Suk Chang, Hojin Kim, Jin Sung Kim, Jaehyun Seok

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Integrative Medicine

Abstract Preview: Purpose: This study aims to leverage 3D dose distribution data to develop a machine learning model capable of accurately predicting lymphedema occurrence in patients undergoing 3D conformal radiation ...

CT-on-Rails Longitudinal Image Quality Stability for Intensity Modulated Adaptive Proton Therapy

Authors: Austen N. Curcuru, Arash Darafsheh, Winter Green, Yao Hao, Baozhou Sun, Tiezhi Zhang, Tianyu Zhao, Xiandong Zhao

Affiliation: WashU Medicine, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine, Washington University in St. Louis, University of South Florida, Baylor College of Medicine

Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) requires precise setup imaging due to the sharp dose gradients and rapid distal fall-off seen in proton therapy dose distributions. Additionally, onl...

Characterization of Commercially-Available Dosimeters and Prototype Diamond Detectors for Absolute Flash Dosimetry of Small-Field Pulsed Proton Beams

Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang

Affiliation: 4Physikalisch-Technische Werkstätten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...

Clinical Implementation of Volumetric Modulated Arc Therapy (VMAT) for Total Body Irradiation (TBI) with Off-the-Shelf Tools

Authors: Kai-Cheng Chuang, Oana I. Craciunescu, Christopher Kelsey, Joseph Kowalski, Nicole Larrier, Xinyi Li, Sheridan G. Meltsner, Anna E. Rodrigues, Yang Sheng, Qiuwen Wu

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: To clinically implement a Volumetric Modulated Arc Therapy (VMAT) procedure for Total Body Irradiation (TBI) with off-the-shelf tools.
Methods: Patient is treated on linac couch with a hyb...

Clinical Validation of a Deep-Learning Segmentation Tool for Head and Neck Cancer Patients and Thoracic and Abdominal Cancer Patients

Authors: Haijian Chen, Katja M. Langen, William Andrew LePain, Claire Tran, Mingyao Zhu

Affiliation: Emory Healthcare, Emory University, Georgia Institute of Technology

Abstract Preview: Purpose: To validate the performance of a commercial deep-learning segmentation (DLS) tool for head and neck cancer (HNC) and thoracic and abdominal cancer (TAC) by comparing it to manual segmentation...

Comparison of Cine Cardiac Magnetic Resonance (CMR) Imaging Performance: 0.6 T Versus 1.5 T, Is 0.6 T Fit for Purpose?

Authors: Jacinta E. Browne, Tzu Cheng Chao, Ajit Deveraj, Ece Ercan, Tim Leiner, Alessio Perazzolo, Michal Povazan, Jouke Smink, Camilla Vita, Spencer Waddle, Dinghui Wang

Affiliation: Università Cattolica del Sacro Cuore, Philips Healthcare, Mayo Clinic

Abstract Preview: Purpose:
In recent years, mid-field MRI has shown promise to meet the technical demands of cardiac imaging1. Mid-field strengths offer advantages to CMR due to shorter T1-relaxation times, lower sp...

Comprehensive Analysis of Plan Modulation in SRS/SBRT Plans: A Single Institution Study of 461 Cases

Authors: Yunfeng Cui, Will Giles, Xinyi Li, Ke Lu, Jennifer C. O'Daniel, Anna E. Rodrigues, Chunhao Wang, Lana Wang, Yibo Xie, Sua Yoo, Jingtong Zhao

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose:
To establish quantitative measurement of plan modulation for SRS/SBRT treated with Volumetric Modulated Arc Therapy (VMAT) on C-arm LINACs.
Methods:
A total of 461 plans were analyze...

Comprehensive Commissioning of an O-Ring-Shaped Image-Guided Radiotherapy System with a Gimbal-Mounted Linear Accelerator

Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago

Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University

Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...

Deep Learning-Based Fast CBCT Imaging with Orthogonal X-Ray Projections for Gynecological Cancer Radiotherapy

Authors: Beth Bradshaw Ghavidel, Chih-Wei Chang, Yuan Gao, Priyanka Kapoor, Shaoyan Pan, Junbo Peng, Richard L.J. Qiu, Jill Remick, Justin R. Roper, Zhen Tian, Xiaofeng Yang

Affiliation: Whinship Cancer Institute, Emory University, Emory University, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Current cone-beam computed tomography (CBCT) typically requires no less than 200 degrees of angular projections, which prolongs scanning time and increases radiation exposure. To address thes...

Dose Distribution Analysis for Different Geometries of a Multiple-X-Ray Source Array (MXA) CT Scanner

Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski, Huanyi Zhou

Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation

Abstract Preview: Purpose: A Multiple-X-ray Source Array (MXA) for CT (MXA-CT) is under development to mitigate cone beam artifacts in axial CT scans using wide collimation. The purpose of this study is to assess the i...

Dosimetric Parameters for Lattice Spatially Fractionated Radiotherapy (LRT) : Pros and Cons

Authors: Lining Chen, Zhitao Dai, Shumei Jia, Yajun Jia, Enzhuo Quan

Affiliation: Cancer Hospital Chinese Academy of Medical Sciences, Shenzhen Center, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: This work reviewed 12 patient clinical LRT treatments in physics view including geometric and dosimetric parameters and discussed the pros and cons related to the latter.
Methods: Geometri...

Dual-Domain Neural Network Cone-Beam CT Correction for Online Adaptive Proton Therapy

Authors: Daniel H. Bushe, Arthur Lalonde, Hoyeon Lee, Harald Paganetti, Brian Winey

Affiliation: Universite de Montreal, Massachusetts General Hospital, Massachusetts General Hospital and Harvard Medical School, University of Hong Kong

Abstract Preview: Purpose: Improving the precision and fidelity of daily volumetric imaging is essential for enabling adaptive proton therapy (APT). While cone-beam CT (CBCT) provides daily volumetric imaging, their ut...

Evaluation of Hybrid Dynamic Conformal Arc Planning for SRS and SBRT Treatment

Authors: Pat Esposito, Ashley Klein, Carmine Verna, Ling Zhuang

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: To evaluate dosimetric parameters and treatment delivery efficiency between volumetric modulated arc therapy (VMAT) and hybrid dynamic conformal arc (HDCA) on SRS and SBRT planning through st...

Evaluation of Plan Quality and Optimal Isocenter Arrangement for Total Marrow and Lymphoid Irradiation on a Ring-Gantry Linac with Dual-Layer Mlc Using the Knowledge-Based Planning Technique

Authors: Chunhui Han, An Liu, Anthony Magliari, Lesley Rosa

Affiliation: Office of Medical Affairs, Varian, A Siemens Healthineers Company, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: To evaluate the performance of a knowledge-based planning (KBP) optimization model for total marrow and lymphoid irradiation (TMLI) on a ring-gantry linac with a dual-layer MLC and to evaluat...

Four-Dimensional Computed Tomography Based on 16cm-Long Detectors Vs 4cm-Long Detectors: Dose Validation

Authors: Qianyi Xu, Inhwan Yeo

Affiliation: INOVA Schar Cancer Institute, Thomas Jefferson University

Abstract Preview: Purpose:
Four-dimensional computed tomography(4DCT) is prone to a geometrical error when respiration changes upon patient shift. 4DCT with a longer-length detector(16cm), uninvolving the shift, has...

Four-Dimensional on-Beam Computed Tomography Reconstruction from Projection Image Differences Representing Motion Change

Authors: Kwang-Ho Cheong, Seungryong Cho, Joonil Hwang, Jae Won Jung, Hoyeon Lee, Raymond Hyunwoo Moon, Inhwan Yeo, Jihyung Yoon

Affiliation: East Carolina University, INOVA Schar Cancer Institute, University of Hong Kong, Hanllym University, KAIST, University of Rochester

Abstract Preview: Purpose: Monitoring a target and neighboring organs during beam delivery is crucial for successful radiotherapy (RT). Conventional transit imaging methods lack volumetric reconstruction capabilities, ...

From Supine to Upright: A Geometric Shift in Perspective

Authors: Ben Durkee, Renata Farrell, Carri K. Glide-Hurst, Colin Harari, Alex Singleton Kuo, Chase Ruff, Jordan M. Slagowski, Yuhao Yan

Affiliation: University of Wisconsin, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Advances in upright CT and patient positioning system now enables high quality daily CT imaging and treatment delivery in the upright position, providing benefits including reduced internal m...

Generalized 2D Cine Multi-Modal MRI-Based Dynamic Volumetric Reconstruction Using Motion-Aligned Implicit Neural Network with Spatial Prior Embedding

Authors: Ming Chao, Karyn A Goodman, Yang Lei, Tian Liu, Jing Wang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose: Real-time volumetric MRI is essential for motion management in MRI-guided radiotherapy (MRIgRT), yet acquiring high-quality 3D images remains challenging due to time constraints and motion ar...

Isocenter Optimization for Linear Accelerator-Based Radiosurgical Treatment Planning for Multiple Brain Metastases

Authors: J. Daniel Bourland, Christina K Cramer, Justin M. Napolitano, James D. Ververs

Affiliation: Wake Forest University School of Medicine

Abstract Preview: Purpose:
Brain metastases (BM) can be treated with linear accelerator (LINAC)-based stereotactic radiosurgery (SRS). Treatment planning for this modality has evolved over time; treatment plans typi...

Key Tumor Volume Zones for Advancing the Radiomics-Based Distant Recurrence Prediction

Authors: Ryan Alden, Tithi Biswas, Kaushik Halder, Felix Maria-Joseph, Michael Mix, Rihan Podder, Tarun Kanti Podder

Affiliation: SUNY Upstate Medical University, IIT-Roorkee, University of Florida

Abstract Preview: Purpose: Radiomics feature-based model for predicting distant recurrence can potentially provide critical insight for clinical decision-making and assistance in treatment strategies. This study focuse...

Memory-Efficient Deep Learning for Volumetric Cone-Beam CT Image Reconstruction

Authors: Ziqi Gao, Lei Xing, Siqi Ye, S. Kevin Zhou

Affiliation: Department of Radiation Oncology, Stanford University, University of Science and Technology of China (USTC)

Abstract Preview: Purpose: To address the challenge of high memory usage in volumetric cone-beam CT (CBCT) imaging, we propose a method that combines joint reconstruction and super-resolution for sparsely sampled CBCT ...

Motion Correction-Driven Patient-Specific 2D Cine MRI-Based Dynamic Volumetric Reconstruction for MRI-Guided Radiotherapy Intra-Fractional Motion Monitoring

Authors: Karyn A Goodman, Yang Lei, Tian Liu, D. Michael Lovelock, Charlotte Elizabeth Read, Jing Wang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose: Real-time volumetric MRI is essential for precise motion management in MRI-guided radiotherapy (MRIgRT). While 2D Cine MRI offers high temporal resolution for motion tracking, it inherently l...

Muilt-Instance Learning Model with 2D and 3D Features Representation and Transformer-Based Prediction for FDG PET Tumor Chemoradiation Response of La-NSCLC

Authors: Stephen R. Bowen, Chunyan Duan, Daniel S. Hippe, Qiantuo Liu, Jiajie Wang, Shouyi Wang, Faisal Yaseen, Han Zhou

Affiliation: Tongji University, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Fred Hutchinson Cancer Center, University of Texas at Arlington

Abstract Preview: Purpose: Predicting the effects of the spatial-temporal tumor response to chemoradiation can assist in adjusting radiation dose and support clinical decision-making in radiotherapy. A multi-instance l...

Novel 3D Imaging Systems for Surgical Guidance : Loop-X and Nview S1 in Comparison with O-Arm

Authors: Jia Wang, Vani Yadav

Affiliation: Stanford University

Abstract Preview: Purpose: To evaluate the radiation dose and imaging quality of two novel CBCT X-Ray imaging systems used in spine surgeries.
Methods: CBCT scan of ACR CT and CTDI phantoms was performed to acquire ...

Novel Automatic Detection of Surface Brachytherapy Applicators and Catheters on Vibe MR Images

Authors: Ivan M. Buzurovic, Evangelia Kaza

Affiliation: Department of Radiation Oncology, Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology

Abstract Preview: Purpose: Recent advances allow for depiction of surface brachytherapy flap applicators using MRI, with empty catheters detected by signal intensity reduction. As manual catheter detection is subjectiv...

Optimizing Quality Assurance CT Frequency and Setup Uncertainty in Brain Proton Therapy Patients for Reduced Normal Tissue Dose

Authors: Rachel B. Ger, Heng Li, Anh Tran

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Proton therapy patients undergo quality assurance CT scans (QACTs) during treatment to verify dosimetric accuracy and utilize robustness scenarios for setup and range uncertainties. For intra...

Prostate Dosimetric Comparison between Cyberknife and Radixact Modalities Using Precision and Raystation Planning Systems

Authors: Mireille Conrad, Cédric De Marco, Marie Fargier-Voiron, Maud Jaccard, Oscar Matzinger, Nicolas Joel Lionel Perichon

Affiliation: Clinique De Genolier

Abstract Preview: Purpose: The Accuray Synchrony real-time motion fiducial tracking solution allows for prostate stereotactic treatment on both Cyberknife and Radixact machines. In our radiotherapy department, two solu...

Rapid CBCT Imaging with Ultra-Sparse X-Ray Projections for Head & Neck Cancer Radiotherapy

Authors: Hania A. Al-Hallaq, Chih-Wei Chang, Anees H. Dhabaan, Yuan Gao, Shaoyan Pan, Junbo Peng, Richard L.J. Qiu, Keyur Shah, Sibo Tian, Zhen Tian, Xiaofeng Yang, David Yu, Jun Zhou

Affiliation: Emory University, Whinship Cancer Institute, Emory University, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Traditional cone-beam computed tomography (CBCT) often requires multiple angular projections, increasing radiation exposure and extending scanning times, which may lead to heightened patient ...

Target Region-Specific Dose-Volume Parameters for Estimate of Brain Toxicity in Single-Isocenter Multiple-Metastases Linac-Based Stereotactic Radiosurgery

Authors: David L. Barbee, Jose R. Teruel Antolin, Jinyu Xue

Affiliation: NYU Langone Health

Abstract Preview: Purpose: This work introduces a method of regional dose evaluation of normal brain tissue using local target-specific evaluation and compares to global dose evaluation for linac-based single-isocenter...

The GYN Webapp: A Centralized Tool for Enhancing HDR Brachytherapy Treatment Quality and Clinical Outcomes

Authors: Kevin Albuquerque, Ti Bai, Yesenia Gonzalez, Brian A. Hrycushko, Zohaib Iqbal, Paul M. Medin, Shanshan Tang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Cervical cancer remains one of the most common and significant gynecological (GYN) malignancies globally, often presenting at advanced stages where radiation therapy and high-dose-rate (HDR) ...

Time-Resolved CBCT: A Novel Solution for Motion Management

Authors: Bulent Aydogan, Xiaochuan Pan, Erik Pearson, Zheng Zhang

Affiliation: The University of Chicago

Abstract Preview: Purpose: Motion management remains one of the significant challenges in external beam radiation therapy (RT). We are developing time-resolved cone-beam computed tomography (trCBCT) for imaging during ...

Utilizing Multiple Modalities to Improve Models to Predict Changes in International Prostate Score for Prostate Cancer

Authors: Matthew C Abramowitz, Alan Dal Pra, Rodrigo Delgadillo, Nesrin Dogan, John C. Ford, Kyle R. Padgett, Levent Sensoy, Benjamin Spieler, Matthew T. Studenski, Jace Allen Walker

Affiliation: University of Miami, Department of Radiation Oncology, University of Miami, University of Miami Sylvester Comprehensive Cancer Center, University of Miami School of Medicine

Abstract Preview: Purpose:
Toxicities that affect a patient’s quality-of-life due to prostate cancer (pCa) radiation therapy (RT) are receiving more attention as RT has become increasingly successful in treating pCA...