Authors: Jingyuan Chen, Sheng Li, Tianming Liu, Wei Liu, Zhengliang Liu, Zhong Liu, Daniel Ma, Samir H. Patel, Guangya Wang, Yunze Yang
Affiliation: University of Miami, Mayo Clinic, School of Data Science, University of Virginia, School of Computing, University of Georgia, Department of Radiation Oncology, Mayo Clinic, Institute of Western China Economic Research, Southwestern University of Finance and Economics
Abstract Preview: Purpose:
Traditional patient outcome analyses relied heavily on conventional statistical models that primarily elucidate correlation rather than causal relationships. In this study, we aim to ident...
Authors: Jenghwa Chang, Kuan Huang, Lyu Huang, Jason Lima, Jian Liu, Farzin Motamedi
Affiliation: Northwell, Department of Computer Science and Technology, Kean University, Physics and Astronomy, Hofstra University, Hofstra University Medical Physics Program
Abstract Preview: Title: A Deep Learning Approach to the Prediction of Gamma Passing Rates in VMAT Radiotherapy Plans for Adaptive Treatment.
Purpose: This study aims to develop a deep learning algorithm to predict ...
Authors: Edward D. Brandner, Weihua Fu, M. Saiful Huq, Ronald John Lalonde, Kiran Mehta, Hima Bindu Musunuru, Yongqian Zhang
Affiliation: UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, University of Pittsburgh School of Medicine and UPMC Hillman CancerCenter
Abstract Preview: Purpose: Treatment of diffuse and extensive involvement of the skull by malignancy presents a difficult challenge for radiation therapy. This study reports preliminary experience of a modified volumet...
Authors: Leslie Bell, Kai Ding, Reza Farjam, Russell K Hales, Sarah Han-Oh, Hamed Hooshangnejad, Jina Lee, K. Ranh Voong
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University
Abstract Preview: Purpose: Optimal beam arrangement is crucial in automation and standardization of thorax radiotherapy where substantial tissue heterogeneity and several critical organs at risks (OARs) exist. Here, we...
Authors: John Bennet, Indrin J. Chetty, Tai H. Dou
Affiliation: Department of Radiation Oncology,Cedars Sinai Medical Center, Department of Radiation Oncology, Cedars Sinai Medical Center, Department of Radiation Oncology,Cedars-Sinai Medical Center
Abstract Preview: Purpose:
To investigate the effect of complexity of stereotactic radiosurgery (SRS) volumetric modulated arc therapy plans on gamma pass rates (GPR) using a novel high-resolution ion chamber array ...
Authors: Richard Lesieur, Olivia Magneson, David E. Solis, Sotirios Stathakis
Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center
Abstract Preview: Purpose: This study evaluates the deliverability and precision of multileaf collimator (MLC) positioning in treatment plans generated by two different Treatment Planning Systems (TPS), Monaco and Pinn...
Authors: Andrew Huang, Jonathan Huang, Andrew S Kennedy, Ellie Grace Kong, Ajay Zheng
Affiliation: New York Proton Center, Centennial Medical Center, Executive Medical Physics Associates, Sarah Cannon Cancer Institute, Belmont University
Abstract Preview: Purpose:
Lung stereotactic body radiotherapy (SBRT) is the standard of care for early-stage lung cancer. Respiratory phase gating can be applied to mitigate motion-induced effects. The purpose of t...
Authors: Austen N. Curcuru, Arash Darafsheh, Winter Green, Yao Hao, Baozhou Sun, Tiezhi Zhang, Tianyu Zhao, Xiandong Zhao
Affiliation: WashU Medicine, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine, Washington University in St. Louis, University of South Florida, Baylor College of Medicine
Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) requires precise setup imaging due to the sharp dose gradients and rapid distal fall-off seen in proton therapy dose distributions. Additionally, onl...
Authors: Kaile Li, Esmail Parsai
Affiliation: Alexander T. Augusta Military Medical Center, Alexander T. Augusta Miliary Medical Center
Abstract Preview: Purpose: To evaluate the sensitivity of the portal dosimetry system with the Arc CHECK system at identical Volumetric Modulated Arc Therapy (VMAT) setup
Methods: An Arc CHECK system from Sun Nuclea...
Authors: Kai-Cheng Chuang, Oana I. Craciunescu, Christopher Kelsey, Joseph Kowalski, Nicole Larrier, Xinyi Li, Sheridan G. Meltsner, Anna E. Rodrigues, Yang Sheng, Qiuwen Wu
Affiliation: Duke University, Duke University Medical Center
Abstract Preview: Purpose: To clinically implement a Volumetric Modulated Arc Therapy (VMAT) procedure for Total Body Irradiation (TBI) with off-the-shelf tools.
Methods: Patient is treated on linac couch with a hyb...
Authors: Yunfeng Cui, Will Giles, Xinyi Li, Ke Lu, Jennifer C. O'Daniel, Anna E. Rodrigues, Chunhao Wang, Lana Wang, Yibo Xie, Sua Yoo, Jingtong Zhao
Affiliation: Duke University, Duke University Medical Center
Abstract Preview: Purpose:
To establish quantitative measurement of plan modulation for SRS/SBRT treated with Volumetric Modulated Arc Therapy (VMAT) on C-arm LINACs.
Methods:
A total of 461 plans were analyze...
Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago
Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University
Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...
Authors: Nrusingh C. Biswal, Sally Cheston, Sung-Woo Lee, Weiguang Yao, Baoshe Zhang
Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine
Abstract Preview: Purpose: The deep inspiration breath-hold (DIBH) technique in left breast radiation reduces doses to critical organs such as the heart, left lung, and left anterior descending artery (LAD). With the a...
Authors: Mark Bowers, Gabriel Carrizo, Jimmy Caudell, Vladimir Feygelman, Kevin Greco, Christian Hahn, Jihye Koo, Kujtim Latifi, Fredrik Lofman, Jacopo Parvizi, Muqeem Qayyum, Caleb Sawyer
Affiliation: RaySearch Laboratories, Moffitt Cancer Center
Abstract Preview: Purpose: Head and neck (H&N) radiotherapy planning is complex, with multiple competing objectives. We endeavored to improve efficiency of planning by developing a deep learning (DL) model trained to p...
Authors: Ming Chao, Hao Guo, Tenzin Kunkyab, Yang Lei, Tian Liu, Kenneth Rosenzweig, Robert Samstein, James Tam, Junyi Xia, Jiahan Zhang
Affiliation: Icahn School of Medicine at Mount Sinai
Abstract Preview: Purpose:
The aim of the study is to develop a trade-off prediction model to efficiently guide the treatment planning process for patients with stage III non-small cell lung cancer (NSCLC).
Metho...
Authors: Dr. Sheaka Alobaidli, Anju K V, Dr. Chiranjib Konar, Sreejesh MS, Dr. Vijayaprabhu N, Dr. Deepti Sharma, Dr. Hanuman Prasad Yadav
Affiliation: Amity Institute of Applied Sciences, Kuwait Cancer Control Center, Institute of Liver and Biliary Sciences, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Amity institute of Applied Sciences, Amity University, Institute of Liver and Biliary Sciences(ILBS)
Abstract Preview: Purpose:
The accuracy of dose delivery in stereotactic body radiotherapy (SBRT) is critical for effectively treating hepatocellular carcinoma (HCC). This study aims to develop patient-specific 3D-p...
Authors: Yi Li
Affiliation: Department of Radiation Oncology, the First Affiliated Hospital of Xi'an Jiaotong University
Abstract Preview: Purpose: Advances in radiotherapy technology are crucial for improving cervical cancer (CC) treatment. This study explores a novel X-ray and ฮณ-ray dual-modality radiation (TaiChiB) system, comparing i...
Authors: Awens Alphonse, Nebi Demez, Noufal Manthala Padannayil, Haley Park, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Nishan Shrestha, Somol Sunny
Affiliation: Florida Atlantic University, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida
Abstract Preview: Purpose: This study evaluates the dosimetric effects of patient positioning errors, including setup inaccuracies and yaw deviations, on dual-isocenter volumetric modulated arc therapy (VMAT) plans for...
Authors: Sumanta Manna, Atul Mishra, Surendra Prasad Mishra, Kailash Kumar Mittal, Anoop Kumar Srivastava, Neha Yadav
Affiliation: Department of Radiation Oncology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Department of radiation Oncology, Apollomedics Super Speciality Hospitals, Department of Radiation Oncology, Uttar Pradesh University of Medical Sciences, Department of Radiation Oncology, Kalyan Singh Super Specialty Cancer Institute
Abstract Preview: Purpose: This study aimed to assess the dosimetric performance of Volumetric Modulated Arc Therapy (VMAT), step-and-shoot Intensity-Modulated Radiation Therapy (ss-IMRT), and dynamic Intensity-Modulat...
Authors: Megan E. Daly, Ryan D. Hernandez, Abriel J. Horak, Soo Kyoung Kim, Peter C. Park, Dwaine O. Spence, Payton H. Stone, Cari L. Wright
Affiliation: UC Davis Cancer Center
Abstract Preview: Purpose: To evaluate a fallback planning workflow used for cross-modality treatment planning and delivery between helical Tomotherapy and volumetric modulated arc therapy (VMAT) using conventional L-s...
Authors: Cambridge L Bui-Nguyen, Alexander S. Nguyen, Liqiang (Lee) Tao
Affiliation: Varian AOS @Epic Care, UC Berkeley
Abstract Preview: Purpose: Dynamic Winston-Lutz (WL) testing provides a comprehensive framework for evaluating the accuracy of isocenter alignment. This study investigates the impact of dynamic beam modulation, such as...
Authors: Jacob S. Buatti, Kristen A. Duke, Malena Fassnacht, Neil A. Kirby, Parker New, Niko Papanikolaou, Arkajyoti Roy, Yuqing Xia, Michelle de Oliveira
Affiliation: The University of Texas San Antonio, UT Southwestern Medical Center, UT Health San Antonio
Abstract Preview: Purpose:
Quantifying and visualizing uncertainty is critical for building clinical trust in AI-generated dose distributions. This study evaluates Monte Carlo Dropout (MCD), Snapshot Ensemble (SE), ...
Authors: Pat Esposito, Ashley Klein, Carmine Verna, Ling Zhuang
Affiliation: Northwestern Medicine
Abstract Preview: Purpose: To evaluate dosimetric parameters and treatment delivery efficiency between volumetric modulated arc therapy (VMAT) and hybrid dynamic conformal arc (HDCA) on SRS and SBRT planning through st...
Authors: Chunhui Han, An Liu, Anthony Magliari, Lesley Rosa
Affiliation: Office of Medical Affairs, Varian, A Siemens Healthineers Company, Department of Radiation Oncology, City of Hope National Medical Center
Abstract Preview: Purpose: To evaluate the performance of a knowledge-based planning (KBP) optimization model for total marrow and lymphoid irradiation (TMLI) on a ring-gantry linac with a dual-layer MLC and to evaluat...
Authors: Christine V. Chung, Laurence Edward Court, Meena S. Khan, Ethan B. Ludmir, Rachael M. Martin Paulpeter, Saurabh Shashikumar Nair, Callistus M. Nguyen, Joshua S. Niedzielski, Luis Augusto Perles
Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Spatially Fractionated Radiation Therapy (SFRT) has re-emerged as an efficacious treatment approach for bulky solid tumors. RapidArc Dynamic (RAD) has unique beam delivery capabilities that m...
Authors: Yang Sheng, Qingrong Jackie Wu, Qiuwen Wu, Xin Wu, Dongrong Yang
Affiliation: Duke University Medical Center
Abstract Preview: Purpose:
Treatment planning for intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) relies on inverse planning, an iterative and non-intuitive process of adjust...
Authors: Qianyi Xu, Inhwan Yeo
Affiliation: INOVA Schar Cancer Institute, Thomas Jefferson University
Abstract Preview: Purpose:
Four-dimensional computed tomography(4DCT) is prone to a geometrical error when respiration changes upon patient shift. 4DCT with a longer-length detector(16cm), uninvolving the shift, has...
Authors: Xiangli Cui, Lingling Liu
Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Cancer Hospital, Chinese Academy of Sciences
Abstract Preview: Purpose:
Respiratory motion introduces substantial dose uncertainties in lung cancer radiotherapy, particularly affecting dose distribution in Simultaneous Integrated Boost-Stereotactic Body Radiot...
Authors: Minbin Chen, Gang Liu, Manju Liu, Weiwei Sang, Pulin Sun, Mingyuan Ye, Fang-Fang Yin, Lihua Zhang, Haiming Zhu
Affiliation: Jiahui International Hospital, Radiation Oncology, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University, Duke Kunshan University, The First People's Hospital of Kunshan
Abstract Preview: Purpose: This study aims to evaluate the effects of varying the number of arcs on treatment plans created using Volumetric Modulated Arc Therapy (VMAT) for Lattice radiotherapy (LRT).
Methods: Thre...
Authors: Nobuki Imano, Daisuke Kawahara, Akito S Koganezawa, Yuji Murakami, Ikuno Nishibuchi, Takuya Wada
Affiliation: Department of Information and Electronic Engineering, Faculty of Science and Engineering, Teikyo University, Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University
Abstract Preview: Purpose: Adaptive radiotherapy (ART) compensates for treatment plans based on anatomical changes while not considering biological effects such as interruptions during treatment. This study aims to dev...
Authors: Ryan Clark, Jon Cornelisse, Kenny Guida, Anthony Magliari, Lesley Rosa, Megan Smith, Shane R Stecklein
Affiliation: Office of Medical Affairs, Varian, A Siemens Healthineers Company, Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Post-mastectomy radiation therapy (PMRT) can pose a challenge for planners of all levels of experience. For cases where 3D conformal therapy yields undesirable results (i.e., dose heterogenei...
Authors: J. Daniel Bourland, Christina K Cramer, Justin M. Napolitano, James D. Ververs
Affiliation: Wake Forest University School of Medicine
Abstract Preview: Purpose:
Brain metastases (BM) can be treated with linear accelerator (LINAC)-based stereotactic radiosurgery (SRS). Treatment planning for this modality has evolved over time; treatment plans typi...
Authors: Nesrin Dogan, Panagiota Galanakou, Robert Kaderka
Affiliation: University of Miami, Sylvester Comprehensive Cancer Center, University of Miami Sylvester Comprehensive Cancer Center
Abstract Preview: Purpose:
To develop knowledge-based treatment planning (KBP) for volumetric modulated arc therapy (VMAT) in chest wall treatments with regional nodal involvement. Given the challenges posed due to ...
Authors: Peng Dong, Lei Xing
Affiliation: Department of Radiation Oncology, Stanford University, Stanford University
Abstract Preview: Purpose: Volumetric Modulated Arc Therapy (VMAT) optimization is a complex, non-convex problem with numerous variables and intricate constraints. Traditional optimization methods often lack efficiency...
Authors: Hao Chen, Kai Ding, Xiaoyu Hu, Xun Jia, Heng Li, Devin Miles
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University
Abstract Preview: Purpose: Accurately delivering radiation dose is critical in intensity-modulated proton therapy (IMPT), where intrafraction motion management plays a pivotal role. Our proton therapy system equipped x...
Authors: Steve B. Jiang, Austen Matthew Maniscalco, Dan Nguyen, Chenyang Shen, Jiacheng Xie, Shunyu Yan, Ying Zhang, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas
Abstract Preview: Purpose: Although treatment planning systems (TPSs) can handle dose calculation and plan optimization automatically, planning for radiotherapy still requires extensive efforts and expertise from a mul...
Authors: William T. Hrinivich, Junghoon Lee, Lina Mekki
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins University, Johns Hopkins University
Abstract Preview: Purpose: Volumetric modulated arc therapy (VMAT) planning is a computationally expensive process. In this work, we propose a reinforcement learning (RL) framework to automatically optimize dose rate a...
Authors: Shixiong Huang, Daming Li
Affiliation: The Affiliated Nanhua Hospital, University of South China, The Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University/Hunan Cancer Hospital
Abstract Preview: Purpose: To assess the feasibility of using target current pulse signals to evaluate the output dose of medical standing wave electronic linear accelerators.
Methods: The Target I signal of the acc...
Authors: Adebayo Abe, Samuel Olaolu Adeneye, Eben Aje, Bidemi I. Akinlade, Inioluwa Damilola Ariyo, Lilian Ekpo, Muhammad Habeebu, Adedayo O. Joseph, Charles S. Mayo, Noah Ndianaobong, Ikechi S Ozoemelam, Margaret Dideolu Taiwo, Godwin Uwagba
Affiliation: University of Michigan, University of Ibadan, University of Lagos, Missouri University of Science and Technology, NSIA-LUTH Cancer Center, University of Lagos, NSIA-LUTH Cancer Centre, NSIA-LUTH Cancer Center
Abstract Preview: Purpose:
Head and neck cancers (HNC) present significant challenges in radiotherapy due to complex anatomy and the proximity to critical organs at risk (OARs). These challenges are compounded in na...
Authors: Yukio Fujita, Satoshi Ishikura, Fumiki Ito, Yujiro Nakajima, Takumi Sakamoto, Naoki Tohyama, Ryohei Yamauchi
Affiliation: Komazawa University Graduate School, St. Luke's International Hospital
Abstract Preview: Purpose: The aperture shape controller (ASC) is an Eclipse feature that increases muti-leaf collimator (MLC) aperture size. This study aimed to evaluate the effects of ASC settings on the robustness o...
Authors: Bulent Aydogan, Xiaochuan Pan, Erik Pearson, Zheng Zhang
Affiliation: The University of Chicago
Abstract Preview: Purpose: Motion management remains one of the significant challenges in external beam radiation therapy (RT). We are developing time-resolved cone-beam computed tomography (trCBCT) for imaging during ...
Authors: Michael Armstrong, Courtney R. Buckey, Quan Chen, Suzanne J. Chungbin, Mirek Fatyga, Yi Rong, Jun Tan, Xiang Sheng Yan
Affiliation: Mayo Clinic Arizona, Mayo Clinic
Abstract Preview: Purpose: To model a commercial rotational table in treatment planning system (TPS) for accurate dose optimization and calculation.
Methods: A commercial rotational table (CDR Equilibriumยฎ) is r...
Authors: Laura I. Cervino, Linda X. Hong, Jessica Pagan, Angelica A. Perez-Andujar, Maria Thor
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center, Memorial Sloan-Kettering Cancer Center
Abstract Preview: Purpose: Three-dimensional conformal radiotherapy (3DCRT) and Volumetric-Modulated Arc Therapy (VMAT) are used to treat locally advanced breast cancer. The 3DCRT treatment plans use the treatment fiel...