Search Submissions 🔎

Results for "voxel averaged": 31 found

A Monte Carlo Framework for Automated Quality Assurance of Dynamically Collimated Pencil Beam Scanning Clinical Treatment Deliveries

Authors: Laura Bennett, Wesley S. Culberson, Albert Du, Kevin J. Erhart, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake

Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care, .decimal

Abstract Preview: Purpose: To develop and experimentally validate a novel Monte Carlo (MC) framework designed to enable calculation-based quality assurance (QA) for collimated intensity modulated proton therapy treatme...

Adversarial Diffusion-Based Self-Supervised Learning for High-Resolution MR Imaging

Authors: Zachary Buchwald, Chih-Wei Chang, Zach Eidex, Richard L.J. Qiu, Mojtaba Safari, Shansong Wang, Xiaofeng Yang, David Yu

Affiliation: Emory University and Winship Cancer Institute, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: MRI offers excellent soft tissue contrast for diagnosis and treatment but suffers from long acquisition times, causing patient discomfort and motion artifacts. To accelerate MRI, supervised d...

An Optimal-Mass-Transport-Based Mathematical Model Applied to Brain DCE-MRI to Differentiate Brain Metastases Recurrence from Radiation Necrosis

Authors: Aditya P. Apte, Xinan Chen, Joseph O. Deasy, Ramesh Paudyal, Kyung Peck, Amita Shukla-Dave, Nathaniel Swinburne, Robert J. Young

Affiliation: Department of Radiology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: We apply our novel formulation of unbalanced-regularized-optimal-mass-transport (urOMT) theory to brain DCE-MRI data to quantify and visualize the behaviors of fluid flows in post-treatment f...

Assessment of Off-Target Dose for Curative Treatment of Pregnant Head and Neck Cancer Case: A Monte-Carlo Study

Authors: Brianna Baek, David J. Carlson, Zhe (Jay) Chen, Dae Yup Han, Bon Tack Koo, Hyojun Park

Affiliation: Columbia University, Canyon Crest Academy, Department of Therapeutic Radiology, Yale University School of Medicine, Department of Radiation Oncology, Chung-Ang University Gwang Myeong Hospital

Abstract Preview: Purpose: To find an optimized treatment technique and shielding design for minimizing the dose to a fetus, a Monte-Carlo simulation was performed to evaluate the dosimetric contribution.
Methods: G...

Automated MR Segmentation for Online Adaptive MR-Linac Therapy Using an in-House Model

Authors: David L. Barbee, David Byun, Matt Long, Jose R. Teruel Antolin, Michael J Zelefsky

Affiliation: NYU Langone Health

Abstract Preview: Purpose:
Online adaptive MR-Linac therapy requires contour adaptation, often adding 20 minutes to treatment time and reducing machine throughput. This study introduces a fully automated MR contour ...

BEST IN PHYSICS IMAGING: Dosimetric Impact of Iodinated Contrast Agent on Fibroglandular Tissue in Contrast-Enhanced Digital Mammography

Authors: Hannah Grover, Andrew J. Sampson

Affiliation: Oregon Health & Science University, UT Health San Antonio

Abstract Preview: Purpose: The goal of this work was to quantify the dosimetric impact of iodinated contrast on fibroglandular breast tissue to better inform clinical risk and benefit assessments when determining the m...

BEST IN PHYSICS THERAPY: Population-Based Automated Organs-at-Risk Contouring Outlier Detection and Visualization without Requiring Patient-Specific Reference Contour

Authors: Rex A. Cardan, Carlos E. Cardenas, Quan Chen, Jingwei Duan, Joseph Harms, Joel A. Pogue, Richard A. Popple, Yi Rong, Dennis N. Stanley, Natalie N. Viscariello, Libing Zhu

Affiliation: Washington University in St. Louis, The University of Alabama at Birmingham, Mayo Clinic Arizona, University of Alabama at Birmingham

Abstract Preview: Purpose: Manual verification of organs-at-risk(OARs) delineations is a critical yet time-intensive process, often susceptible to unintentional oversights. To assist the reviewing process, a population...

Correcting for Lung Ventilation in Model-Based CT

Authors: Ryan Andosca, Igor Barjaktarevic, Peter Boyle, Jie Deng, Minji Victoria Kim, Michael Vincent Lauria, Daniel A. Low, Claudia R. Miller, Drew Moghanaki, Louise Naumann, Jack Neylon, Dylan P. O'Connell, Ricky R Savjani

Affiliation: Department of Pulmonology, University of California Los Angeles, University of California, Los Angeles, Department of Radiation Oncology, University of California, Los Angeles, UCLA, UCLA Radiation Oncology

Abstract Preview: Purpose: To develop a Hounsfield Unit ventilation-based correction method for use with model-based CT when used as a replacement for 4DCT.
Methods: The model-based CT we employ is termed 5DCT, whic...

Cumulative Doses in Radiotherapy Treatment of Lymphoma Patients

Authors: Klaus Bacher, Tom Boterberg, Jeff Rutten, Barbara Vanderstraeten, Gwenny Verfaillie, Sarah Waelkens

Affiliation: Ghent University, Ghent University Hospital

Abstract Preview: Purpose: Lymphoma cancer patients frequently receive ionizing radiation during their treatment trajectory, including diagnostic CT, planning CT (pCT), recurrent CBCTs, radiotherapy (out-of-field) dose...

Development of an Innovative and Efficient KBP-Based Automated Method for IMRT Optimization

Authors: Somayeh Gholami, Saeedeh Ketabi, Jeremy Kunz, Ali Yousefi

Affiliation: Department of Radiation Oncology, University of Utah, University of Utah, Department of Management- Operations Research, University of Isfahan

Abstract Preview: Purpose: This paper aims to present a novel approach for automatic knowledge-based planning optimization for Intensity Modulated Radiotherapy, along with the two downsizing techniques for improving th...

Electronic Brachytherapy Dosimetric Reference Datasets Using Model-Based Dose Calculation Algorithms

Authors: David Ayala Alvarez, Facundo Ballester, Luc Beaulieu, Francisco Berumen-Murillo, Jean-Simon Cote, Ernesto Mainegra-Hing, Iymad Mansour, Gaël Ndoutoume-Paquet, Rowan M. Thomson, Christian Valdes, Javier Vijande, Peter G. Watson

Affiliation: Département de physique, de génie physique et d'optique, Université Laval, Laval University, Princess Margaret Cancer Centre, McGill University, Department of Physics and Medical Physics Unit, McGill University, IFIC-UV, University of Valencia, National Research Council Canada, Carleton University, 5Service de Physique Médicale et de Radioprotection, Centre Intégré de Cancérologie, CHU de Québec- Université Laval et Centre de recherche du CHU de Québec, Nuclear Medicine Department, Hospital Regional de Antofagasta

Abstract Preview: Purpose: Modelling electronic brachytherapy (eBT) sources is difficult because of the high-dose gradients and challenges associated with low-energy modelling. This study examines the accuracy of avail...

Enhancing Adaptive Radiotherapy Segmentation with a 3D Unet Framework and Prior Fraction Information

Authors: Jennifer L. Dolan, Chengyin Li, Parag Parikh, Doris N. Rusu, Kundan S Thind

Affiliation: Henry Ford Health, Cedars-Sinai Medical Center

Abstract Preview: Purpose: The time and resource demands of online Adaptive Radiation Therapy (ART) can limit its widespread clinical adoption and potentially impact patient throughput. To address this, we developed a ...

Evaluation of Dose-Rate Metrics in Intensity Modulated Proton Therapy for Prostate Cancer Treatments

Authors: Stella Flampouri, Edgar Gelover, William Andrew LePain, Roelf L. Slopsema, Alexander Stanforth, Mingyao Zhu

Affiliation: Emory Healthcare, Emory University

Abstract Preview: Purpose: Little consideration was given to the change in dose rate (DR) observed when moving to pencil beam scanning (PBS). This study reports on DR in clinical prostate PBS plans. While dose distribu...

Exploiting the Glycerol CH2 Resonances for Estimating Relative Free Fatty Acid to Triglyceride Concentration Ratios

Authors: José Antonio Klautau Toffoli, Anthony G. Tessier, Atiyah Yahya

Affiliation: Department of Oncology, University of Alberta

Abstract Preview: Purpose: To demonstrate that magnetic resonance spectroscopy (MRS) methyl (≈0.9 ppm) to glycerol (≈4.1-4.3 ppm) resonance area ratios correlate with relative concentrations of free fatty acids to trig...

Glandular Dose Map in Voxelized Phantoms across Advanced Breast Imaging Modalities Obtained from Monte Carlo Simulations

Authors: Rodrigo T Massera, Sofia Giaccone Thomaz, Alessandra Tomal, Giovanna Tramontin

Affiliation: Universidade Estadual de Campinas. Instituto de FĂ­sica Gleb Wataghin, Department of Imaging & Pathology, unit of Medical Physics & Quality Assessment, KU Leuven

Abstract Preview: Purpose: Monte Carlo simulations are increasingly used in breast dosimetry for their precision in estimating difficult-to-measure quantities, such as glandular dose. With ionizing radiation in breast ...

Imaging of Mn Washout in the Individual Welder Brain after Wearing Powered Air-Purifying Respirators (PAPRs)

Authors: Ulrike Dydak, Chia-Tien Hsu, Chang Geun Lee, Cora Mizimakoski, Humberto Monsivais, Jae Hong Park

Affiliation: Purdue University

Abstract Preview: Purpose: Overexposure to manganese (Mn) from inhaling welding fumes can lead to cognitive and motor deficits. We developed a whole-brain Mn-mapping approach to detect subtle but significant increases ...

Improved SNR and Estimation Accuracy for Deuterium-MRI Acquired with Chemical Shift Imaging at 7 Tesla

Authors: Muhammed AR Anjum, Andrew J. Fagan

Affiliation: Mayo Clinic

Abstract Preview: Purpose:
This study describes a novel post-processing method to boost image SNR for deuterium-MRI acquired using chemical shift imaging (CSI) at 7T. Deuterium MRI via exogenous administration of a ...

In-Vivo Dosimetry in Positron-Guided Radiation Therapy

Authors: Davide Brivio, Erno Sajo, Ryan Williams, Piotr Zygmanski

Affiliation: University of Massachusetts Lowell, Brigham and Women's Hospital, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School

Abstract Preview: Purpose: To develop a non-invasive 3D in-vivo dosimetry tool exploring the relationship between positron annihilations and dose per voxel using Monte Carlo simulation. The Positron Guided Radiation Th...

Investigating CT-Based Lung Ventilation Heterogeneity As a Biomarker for COPD Severity

Authors: Shiho Amster, Ryan Andosca, Igor Barjaktarevic, Michael Vincent Lauria, Daniel A. Low, Dylan P. O'Connell, Ann Raldow, Brad Stiehl

Affiliation: Department of Pulmonology, University of California Los Angeles, Department of Radiation Oncology, University of California, Los Angeles, Cedars-Sinai Medical Center

Abstract Preview: Purpose: Image-based biomarkers could be useful for disease diagnosis and prognosis, especially in heterogeneous lung diseases like COPD. The purpose of this study is to assess the feasibility of usin...

Investigating Interstitial Fluid Pressure and Hydraulic Conductivity By Examining the Biophysical Properties of Drug Transport Using Cross Voxel Exchange Model and Dynamic Contrast Enhanced MRI

Authors: Catherine Coolens, Janny Yeyoung Kim, Michael Milosevic, Noha Sinno

Affiliation: Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: In solid tumors, Interstitial fluid pressure (IFP) acts as a barrier to molecular transport to the tumor center and serves as a predictor of cancer patients’ treatment responsiveness. The nov...

Lung Mass Variability in Clinical Chest CT Imaging with Automatic Contouring Tool

Authors: Yasaman Anbari, Srinivas Cheenu Kappadath, Benjamin P. Lopez

Affiliation: University of Houston, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To improve lung dosimetry for 90Y-radioembolization planning, CT-based techniques have been proposed for patient-specific lung mass estimation instead of assuming nominal 1 kg lung masses. He...

Monte Carlo Verification of Field-Size Dependent Backscatter Effect in Superficial HDR Brachytherapy

Authors: Mandar S. Bhagwat, Casey Y. Lee

Affiliation: Duke University, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: TG43-based dose calculation leads to inaccurate field-size dependent dose calculation in superficial HDR brachytherapy, due to full-scatter condition accounted in TG43, but not during treatme...

Multi-Path Deep Learning Model for Predicting Post-Radiotherapy Functional Liver Imaging in Patients with Hepatocellular Carcinoma

Authors: Smith Apisarnthanarax, Stephen R. Bowen, Sunan Cui, Jie Fu, Clemens Grassberger, Yulun He, Yejin Kim, Matthew J. Nyflot, Sharon Pai

Affiliation: Department of Radiation Oncology, University of Washington and Fred Hutchinson Cancer Center, Department of Radiation Oncology, University of Washington, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Department of Physics, University of Washington, University of Washington and Fred Hutchinson Cancer Center

Abstract Preview: Purpose: 99mTc-sulfur colloid SPECT imaging enables quantitative assessment of voxel-wise liver function in patients with hepatocellular carcinoma (HCC). Accurately predicting post-radiotherapy (RT) l...

Novel Automatic Detection of Surface Brachytherapy Applicators and Catheters on Vibe MR Images

Authors: Ivan M. Buzurovic, Evangelia Kaza

Affiliation: Department of Radiation Oncology, Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology

Abstract Preview: Purpose: Recent advances allow for depiction of surface brachytherapy flap applicators using MRI, with empty catheters detected by signal intensity reduction. As manual catheter detection is subjectiv...

Patterns of Nanoparticle Uptake for Patients with Multiple Brain Metastases: Similarities and Differences to Standard Gbca

Authors: Stephanie Bennett, Ross I. Berbeco, Ning Jin, Sonal Josan, Justin Michael Sheetz, Atchar Sudhyadhom

Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Massachusetts - Lowell, Siemens Healthineers, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School,, Brigham and Women's Hospital

Abstract Preview: Purpose: AGuIX, a Gadolinium-based theranostic radiosensitizing nanoparticle, is currently under clinical evaluation in Europe and the US. Using patients from the double-blinded NanoBrainMets trial, u...

Performance Evaluation of an Upright, Short-Scan, Cone-Beam, Dedicated Breast CT System.

Authors: Stephen Araujo, Jing-Tzyh Alan Chiang, Cynthia E. Davis, Eri Haneda, Andrew Karellas, Thomas C Larsen, William Ross, Hsin Wu Tseng, Srinivasan Vedantham, Pengwei Wu

Affiliation: Department of Biomedical Engineering, The University of Arizona, GE Aerospace Research, Department of Medical Imaging, The University of Arizona, GE HealthCare Technology & Innovation Center

Abstract Preview: Purpose: The purpose of this work is to describe the design and development of a newly developed upright-geometry dedicated breast CT system and to quantitatively and qualitatively evaluate its imagin...

Quantifying Respiratory Motion Effects in Lung Cancer Radiotherapy Using 4DCT Voxel Analysis

Authors: Chih-Chiang Chang, Chingyun Cheng, Ben Durkee, Minglei Kang, Elissa Khoudary, Yangguang Ma, Xuanqin Mou, YuFei Wang, Tengda Zhang, Wang Zhengda

Affiliation: Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology, The First Affiliated Hospital of Zhengzhou University, School of Software Engineering, Xi’an Jiaotong University, School of information and communications engineering, Faculty of electronic and information engineering, Xi’an Jiaotong University, Department of Medical Physics, Columbia University, University of Pennsylvania, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: This study presents a voxel-based analysis method based on deformable image registration to accurately quantify respiratory-induced motion and deformation of both targets and organs at risk (...

Robust and Radiobiologically Accurate Dose Summation Strategy for Multiple Courses of Stereotactic Re-Irradiation of Metastatic Brain Cancer Patients with Previous WBRT

Authors: Garrett Russell Hamilton, Joshua Misa, Damodar Pokhrel, William St. Clair

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Recurrent brain metastasis is very common, and patients who previously received whole-brain radiotherapy (WBRT) may receive an additional course(s) of stereotactic radiosurgery (SRS) to selec...

Simultaneous Synthesis of Lung Perfusion and Ventilation Images from CT Using a Dual-Decoder Residual Attention Network for Lung Disease Diagnosis

Authors: Li-Sheng Geng, David Huang, Haoze Li, Xi Liu, Meng Wang, Tianyu Xiong, Ruijie Yang, Weifang Zhang, Meixin Zhao

Affiliation: School of Physics, Beihang University, Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Department of Radiation Oncology, Peking University Third Hospital, Department of Nuclear Medicine, Peking University Third Hospital, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: This study aimed to develop a deep learning-based framework for simultaneously generating lung perfusion and ventilation images from three-dimensional computed tomography (3D CT) images.
M...

Technique Factors Optimization and Radiation Dosimetry of an Upright, Short-Scan, Cone-Beam, Dedicated Breast CT System

Authors: Stephen Araujo, Jing-Tzyh Alan Chiang, Cynthia E. Davis, Eri Haneda, Andrew Karellas, Thomas C Larsen, William Ross, Hsin Wu Tseng, Srinivasan Vedantham, Pengwei Wu

Affiliation: Department of Biomedical Engineering, The University of Arizona, GE Aerospace Research, Department of Medical Imaging, The University of Arizona, GE HealthCare Technology & Innovation Center

Abstract Preview: Purpose: To determine the system parameters and technique factors for image acquisition needed so that the mean glandular dose (MGD) of approximately 4.5 mGy is not exceeded for a recently developed, ...

Validation of an Open Source Automatic Segmentation Tool for Personalized Dosimetry

Authors: Klaus Bacher, Louise D'hondt, Jeff Rutten, Gwenny Verfaillie

Affiliation: Ghent University

Abstract Preview: Purpose: Manual organ segmentation is a very time-consuming but necessary process in personalized dosimetry. Automatic segmentation tools may alleviate this task. In this study the impact of automatic...