Search Submissions 🔎

Results for "water equivalent": 52 found

A 3D Printed Ion Chamber Insert Solution for Absolute Dosimetry with Varying Ionisation Chambers in Radiosurgery.

Authors: Shashanksharad Kale, Gopishankar Natanasabapathi, Daya Nand Kishore Sharma

Affiliation: All India Institute of Medical Sciences (AIIMS), Department of Radiation Oncology, All India Institute of Medical Sciences

Abstract Preview: Purpose:
The study demonstrates a novel 3D printing method to fabricate an ion chamber insert (ICI) for absolute dosimetry purpose in gamma knife radiosurgery (GKRS).
Methods:
Our institute u...

A Preliminary Study of Light-Weighted and Flexible Bismuth Nanoparticle-Based Polymer Matrix for Efficient Radiation Shielding

Authors: Ming Su, Yuenan Nancy Wang

Affiliation: Northeastern University, Hartford Healthcare

Abstract Preview: Purpose: High Z elements such as lead are often used to protect critical structures in clinical radiotherapy. Nanoparticles have different properties than bulk materials. We proposed a polymer matrix ...

Absorption and Material Property Characteristics of 3D-Printing Filaments Based on Monte-Carlo Simulations and Spectral Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: 3D printing has the potential for producing materials useful for the imaging field. This work aims to identify absorption (attenuation coefficient) and material properties (effective atomic n...

Analysis of Inter-Organ Noise Variability for Clinical CT Images across 3133 Image Series

Authors: Lavsen Dahal, Francesco Ria, Ehsan Samei, Justin B. Solomon, Liesbeth Vancoillie, Yakun Zhang

Affiliation: Duke University, Carilion Clinic, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Clinical diagnostic task-based optimization of CT procedures require precise and organ-specific assessments. This study investigates inter-organ noise variability to highlight the limitations...

Assessing Dose Enhancement and Shadowing Effects in Head and Neck Cases with Titanium Mandibular Implants

Authors: Sarah A. Ashmeg, Travis James McCaw, Joseph Shields, Matthew Spector, Christopher Tyerech, Christopher T Wilke

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, UPMC Hillman Cancer Center, Department of Radiation Oncology, University of Pennsylvania, UPMC

Abstract Preview: Purpose: Patients with oral cavity cancer often undergo surgical extirpation prior to radiation, and surgical implants are utilized to reconstruct the resulting defect. This study dosimetrically evalu...

Assessing Long-Term Stability of Parylene-Coated, 3D-Printed Plastic Vessels for Water Calorimetry-Based Radiation Dosimetry

Authors: Philip Cutter, Mark D'Souza, Arman Sarfehnia

Affiliation: Toronto Metropolitan University, Sunnybrook Health Sciences Centre, Sunnybrook Health Science Center

Abstract Preview: Purpose: Water calorimetry (WC) serves as an important standard for measuring absorbed dose to water, an essential metric in radiation therapy. WC directly and absolutely quantifies energy deposition ...

Assessment of the Dosimetric Characteristics of Brass Mesh Bolus in Electron Radiation Therapy

Authors: Hungcheng Hank Chen, Laura A. Doyle, Helena Frisbie-Firsching, Amy S. Harrison, Jackson D Reeves, Lindsay B Romak, Jon Strasser

Affiliation: Christiana Care

Abstract Preview: Purpose: Brass mesh bolus (BMB) is a high-density woven metal mesh which is an excellent alternative to tissue equivalent bolus in photon beams, offering improved surface conformality. Unlike utilizat...

Automated Determination of Deteriorations in Proton Therapy Plan Quality Using Daily Cone Beam CT As a Predictor of Need for Adaptive Replans for Head and Neck Cases

Authors: Matthew J Ferris, Jason K Molitoris

Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine, University of Maryland

Abstract Preview: Purpose: Anatomy changes often happen in head-and-neck (HN) patients treated with proton radiation therapy. These changes can result in deteriorations of target dose coverage and increased dose to org...

Calorimetric Measurement of Absorbed Dose By a Flash Beamline

Authors: Luke Connell, Stephen F. Kry, Malcolm R. McEwen, Bryan R. Muir, James Renaud, Emil Schueler, Hayden Scott, Paige A. Taylor

Affiliation: National Research Council, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: To demonstrate the capability of a robust calorimeter to accurately determine the absorbed dose delivered by an electron FLASH beamline.

Methods: Electron FLASH beams of 6 MeV and 9 Me...

Characterization, Commissioning, and Clinical Evaluation of a Commercial Beo Optically Stimulated Luminescence (OSL) System

Authors: Brett G Erickson, Joseph P. Kowalski, Xinyi Li, Qiuwen Wu, Sua Yoo

Affiliation: Duke University, Mayo Clinic - Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: Characterization and commissioning of the BeO-based myOSLchip system was performed (per TG191) to assess its feasibility as a full replacement for the recalled Landauer aluminum oxide OSL in ...

Checking of Sensitivity of Volumetric Modulated Arc Therapy Quality Assurance System with a Cavity Generation Method

Authors: Kaile Li, Esmail Parsai

Affiliation: Alexander T. Augusta Military Medical Center, Alexander T. Augusta Miliary Medical Center

Abstract Preview: Purpose: To evaluate the sensitivity of the portal dosimetry system with the Arc CHECK system at identical Volumetric Modulated Arc Therapy (VMAT) setup
Methods: An Arc CHECK system from Sun Nuclea...

Comparison of Biological Effectiveness of COMS Eye Plaques with I-125 and Pd-103 Sources Using Equivalent Uniform RBE-Weighted Dose

Authors: Jonathan J. Chen, Alexei V. Chvetsov, Yulun He, Ramesh Rengan, Andrew Stacey, Kent Wallner

Affiliation: University of Washington and Fred Hutchinson Cancer Center, University of Washington

Abstract Preview: Purpose: To show that the RBE of low-energy photon sources used in COMS (Collaborative Ocular Melanoma Study) eye plaques compensates for protracted irradiation and attenuation of low-energy photons i...

Data-Driven Forward Projector for Optimization of the Proton Stopping Power Calibration in Treatment Planning Based on Sparse Proton Radiographies

Authors: Hector Andrade-Loarca, Ines Butz, Chiara Gianoli, Prof. Gitta Kutyniok, Jianfei Li, Katia Parodi, Prof. Vincenzo Patera, Angelo Schiavi, Prof. Ozan Öktem

Affiliation: Sapienza University of Rome, Department of Mathematics, Royal Institute of Technology, School of Computation, Information and Technology, Technische Universitaet Muenchen, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Department of Mathematics, Ludwig-Maximilians-Universität (LMU) München, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München

Abstract Preview: Purpose: To explore and demonstrate the feasibility of accurate and fast prediction of the water equivalent thickness (WET) distribution of tissue traversed by a proton imaging pencil beam, aiming at ...

Design and Testing of a Portable Microwave Scanner for Imaging Soft Tissue and Tumors in Cancer Patients

Authors: Imad M. Ali, Nesreen Alsbou, Sakeeneh Majeed

Affiliation: University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: to design and assess a microwave imaging system equipped with multiple antennas for generating high-resolution 3D images of phantom models that simulate abdominal, thoracic, and brain tissues...

Design and Use of a Modified Commercial Phantom for Gamma Knife End-to-End Testing

Authors: Edward A. Opalko, Matthew B. Podgorsak, Dheerendra Prasad

Affiliation: Roswell Park Comprehensive Cancer Center

Abstract Preview: Purpose: To design a 3D printed insert for Varian’s SRS Head Phantom that allows for multi-planar film dosimetry and to evaluate its ability in end-to-end testing for Gamma Knife treatments.
Method...

Development of a Physical Phantom for Assessing Tube Current Modulation in CT Imaging

Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Laura Dinwiddie, Benjamin Taylor Heggie, Adam Leon Kesner, Juan Camilo Ocampo Ramos, Graham Joseph Stoddard

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson

Abstract Preview: Purpose: The objective of this study is to develop a physical phantom to quantify tube current modulation (TCM) and assess the limitations of a TCM model used in Monte Carlo patient CT organ dose esti...

Development of a Proton CT System Based on 2D Scintillation Detection

Authors: Haonian Gong, Yue Gu, Meiqi Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang

Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China

Abstract Preview: Purpose: To develop a proton CT system using scintillator-based 2D dose distribution detection for accurate proton imaging.
Methods: The proposed proton CT system consists of a brass collimator wit...

Development of a Visualization Tool for LET and Proton Spot Mapping for PB Treatment Planning

Authors: Chang Chang, Mohammad Kanber, Stephen Kenneth Northway

Affiliation: East Carolina University, California Protons Cancer Therapy Center, California Proton Cancer Therapy Center

Abstract Preview: Purpose:
Proton therapy treatment planning involves the consideration of unique physical quantities such as Linear Energy Transfer (LET) and spot location maps that do not exist in photon treatment...

Dosimetric Characteristics of a Commercially Available Platinum Cured Silicone Rubber Material As a Custom Bolus Option

Authors: Jordan B Lunsford, Sagar Pokhrel, Ashkan Shafiee, Curtis S. Whiddon

Affiliation: Atrium Health Wake Forest Baptist, University of North Carolina, Atrium Health Wake Forest Baptist High Point Medical Center

Abstract Preview: Purpose: To investigate the dosimetric characteristics of a platinum cured silicone rubber material (Platsil) for use as custom bolus in radiotherapy
Methods: Sheets of 2, 4, 6, and 8 mm Platsil we...

Dosimetric Validation and Algorithmic Limitations of Pencil Beam Scanning Proton Therapy for Thin Chest-Wall Treatments

Authors: J Isabelle Choi, Meng Wei Ho, Isabel Lin, Hang Qi, Qi Zeng, Ajay Zheng

Affiliation: New York Proton Center, Scarsdale High School

Abstract Preview: Purpose: Proton therapy is a promising treatment modality for breast cancer due to its unique dosimetric advantage. Accurate dose calculation is critical to ensure effective treatment outcomes. The fo...

Evaluation of Charge Collection Performance in the A30 Prototype Parallel Plate Ion Chamber in Ultra-High Dose Rate Beam

Authors: Mervat A. Alharbi, Wesley S. Culberson

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Medical Physics Department, School of medicine and Public Health, University of Wisconsin-Madison

Abstract Preview: Purpose: The charge collection using ionization chambers is challenging at ultra-high dose rates (UHDR) due to the high ion recombination The Exradin A30 prototype parallel-plate ion chamber manufactu...

Evaluation of Ion Chamber Performance and Suitability for Flash Proton Therapy Dosimetry

Authors: Seohyeon An, Yoonsun Chung, Seonghoon Jeong, Seongmoon Jung, Chae-Eon Kim, In Jung Kim, Sung Hun Kim, Se Byeong Lee, Sang-il Pak, Jong In Park

Affiliation: POHANG ACCELERATOR LABORATORY, Hanyang University, Korea Research Institute of Standards and Science (KRISS), Ilsan Paik Hospital, National Cancer Center, National Cancer Center Korea, Korea Research Institute of Standards and Science

Abstract Preview: Purpose: To evaluate the performance of three ion chambers—Advanced Markus (AMC), PinPoint, and Roos—under FLASH proton beam conditions and assess the response of the nozzle monitor chamber for their ...

Evaluation of the Dosimetric Characteristics of Multi-Layers of Brass Mesh Bolus for Electron Treatment

Authors: Yunzhi Ma, Ling Zhuang

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: Multiple layers of brass mesh bolus (RPD, Inc., Albertville, MN) may be needed to provide better body conformity and sufficient dose build up on patient surface during electron treatment. Thi...

Feasibility of a Normoxic N-Vinylpyrrolidone-Based Polymer Gel (VIPET) Dosimeter for Three-Dimensional Proton Beam Measurements

Authors: Yoshihiko Hoshino, Kenji Hotta, Taeko Matsuura, Ai Nakaoka, Hidenobu Tachibana

Affiliation: Hokkaido University, Department of Radiology, Gunma University Hospital, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East

Abstract Preview: Purpose: Gel dosimeters enable three-dimensional dose measurements, but no reports have evaluated the fundamental performance of VIPER-type gel dosimeters in proton beam measurements. Therefore, we ev...

First in-Vivo Application of a Novel Precision Small Animal Irradiation Platform with Proton IMPT Delivery and Advanced on-Board Image-Guidance

Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf

Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital

Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...

First in-Vivo Proton Radiography Experiments for an Image-Guided Small Animal Irradiation Platform with a TimePix3-Based Detector Setup

Authors: Niels Bassler, Jonathan Bortfeldt, Carlos Granja, Guyue Hu, Margarita Kozak, Julie Lascaud, Kirsten Lauber, Grigory Liubchenko, Jasper Nijkamp, Cristina Oancea, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Brita Singers Sørensen, Matthias Würl

Affiliation: Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital, Advacam

Abstract Preview: Purpose: To apply in-vivo proton radiography (pRad) to aid image registration and treatment plan refinement for a novel precision image-guided small animal proton irradiation platform.

Methods:...

Impact of Computed Tomography Noise Reference Levels in a Pediatric Hospital

Authors: Samuel L. Brady, Joseph G. Meier

Affiliation: Cincinnati Childrens Hospital Med Ctr

Abstract Preview: Purpose:
To establish noise reference levels for our pediatric hospital.
Methods:
Water equivalent diameter (Dw) and image noise was automatically measured by using a global noise algorithm i...

Inconsistencies in Methods for CMS Size-Adjusted Dose Measure

Authors: Alexander Alsalihi, Gary Y. Ge, Charles Mike Weaver, Jie Zhang

Affiliation: University of Kentucky

Abstract Preview: Purpose: The upcoming CMS regulation, titled “Excessive Radiation Dose or Inadequate Image Quality for Diagnostic Computed Tomography (CT) in Adults”, employs two measures, size-adjusted DLP (SAD) and...

Investigation of Metallic Artefact Reduction Capabilities of Hypersight Enabled Platforms

Authors: Harald Keller, Iymad Mansour, Jeff D. Winter

Affiliation: Princess Margaret Cancer Centre

Abstract Preview: Purpose: The growing number of adaptive therapy applications is motivating image segmentation and direct dose calculation on CBCT. The purpose of this investigation is to evaluate the recently release...

Matching CT Numbers between a Photon-Counting CT and an Energy-Integrating Detector CT: A Phantom Study

Authors: Afrouz Ataei, Xinhui Duan, Mi-Ae Park, Liqiang Ren

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University

Abstract Preview: Purpose:
Photon-counting CT (PCCT) has become commercially available recently, offering significant potential to enhance patient care. However, it also introduces unique challenges. One such challe...

Minimizing Abscopal Effects in Normal Tissues with Flash-RT: Mechanisms of Action and Potential Clinical Applications

Authors: Liang Cui, Xingyu Lu, Hang Shang, LingHong Zhou

Affiliation: Southern Medical University

Abstract Preview: Purpose: This study examines how varying dose rates of radiotherapy impact normal tissues outside the target area and analyzes the protective effects and regulatory mechanisms of ultra-high dose rate ...

Monte Carlo Evaluation of Water-Equivalent Materials for Nanowire-Based Oslds in Flash Radiotherapy

Authors: James Chun Lam Chow, Harry E Ruda

Affiliation: University of Toronto, Princess Margaret Cancer Centre

Abstract Preview: Purpose: FLASH radiotherapy (FLASH-RT) with dose rate greater than 40 Gy/s, has demonstrated potential in reducing normal tissue toxicity while maintaining tumor control. However, accurate and reliabl...

Monte Carlo Verification of Field-Size Dependent Backscatter Effect in Superficial HDR Brachytherapy

Authors: Mandar S. Bhagwat, Casey Y. Lee

Affiliation: Duke University, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: TG43-based dose calculation leads to inaccurate field-size dependent dose calculation in superficial HDR brachytherapy, due to full-scatter condition accounted in TG43, but not during treatme...

Photon-Counting CT for Estimation of Quantitative Information for Radiation Therapy Treatment Planning: Assessment of Scanning Conditions and Phantom Sizes

Authors: Carina Gassner, Guyue Hu, Thomas Kröncke, Christopher Kurz, Guillaume Landry, Katharina Niepel, Katia Parodi, Franka Risch, Florian Schwarz

Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)

Abstract Preview: Purpose: To evaluate the performance of a clinical photon-counting CT (PCCT) scanner in terms of proton relative stopping power (RSP) estimation using PCCT data and to compare the impact of different ...

Precise Measurement of Leaf Open Time in Tomotherapy Using Advanced Plastic Scintillators

Authors: Marcos Feijoo, Mamoru Ichiki, Tatsuya Maeda, Tatsuhiro Makino, Tomonori Megumi, Tadashi Nakabayashi, Yukino Nakata, Shuichi Ozawa, Daishi Takayama

Affiliation: Hiroshima High-Precision Radiotherapy Cancer Center, Blue Physics LLC, Imamura General Hospital, Accuray Inc.

Abstract Preview: Purpose: This study aims to accurately measure the leaf open time (LOT) of the multi-leaf collimator (MLC) in tomotherapy using an advanced plastic scintillator detector (PSD) with high time resolutio...

Predictive Quality of Differing Body Size Measurands for Radiation Risk Estimation in CT Imaging: A Virtual Trial Study

Authors: Njood Alsaihati, Francesco Ria, Ehsan Samei, Justin B. Solomon, Martina Talarico, Jered Wells

Affiliation: Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Radiation dose and associated risk in X-ray imaging is principally informed by patient size, further used in Computed Tomography (CT) to achieve prescribed image quality levels through tube c...

Proton CT-Imaging and Radiography Using 3D-Detector with Plastic Scintillators for on-Board Proton Imaging

Authors: Salahuddin Ahmad, Imad M. Ali, Zaid Alkalani, Nesreen Alsbou

Affiliation: University of Oklahoma, University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: To design and evaluate a 3D-detector for proton CT-imaging and radiography, utilizing volumetric plastic scintillator detector exposed to high-energy therapeutic beams from proton therapy sys...

QA Your Way: A Customizable 3D Printed CT Simulator Monthly QA Phantom

Authors: Paul J. Black, Jordan B Lunsford, James D. Ververs, India Wood

Affiliation: Atrium Health Wake Forest Baptist, Wake Forest University School of Medicine, Wake Forest School of Medicine

Abstract Preview: Purpose:
To develop a 3D-printed modular CT simulator phantom that allows the assessment of all AAPM TG-66 recommended monthly quality assurance (QA) tests.
Methods:
A modular CT simulator mo...

Quantification of Wet Towel As Bolus on Skin Dose for VMAT Partial Breast Irradiation

Authors: Haiqa Arain, Ping Xia, Zhexuan Zhang

Affiliation: Cleveland Clinic

Abstract Preview: Purpose: To quantify water contents and thickness of wet towel (as a flexible bolus) on curved surface dose for partial breast irradiation.

Methods: Two VMAT partial breast plans (3000 cGy in 5...

Quantifying Respiratory Motion Effects in Lung Cancer Radiotherapy Using 4DCT Voxel Analysis

Authors: Chih-Chiang Chang, Chingyun Cheng, Ben Durkee, Minglei Kang, Elissa Khoudary, Yangguang Ma, Xuanqin Mou, YuFei Wang, Tengda Zhang, Wang Zhengda

Affiliation: Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology, The First Affiliated Hospital of Zhengzhou University, School of Software Engineering, Xi’an Jiaotong University, School of information and communications engineering, Faculty of electronic and information engineering, Xi’an Jiaotong University, Department of Medical Physics, Columbia University, University of Pennsylvania, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: This study presents a voxel-based analysis method based on deformable image registration to accurately quantify respiratory-induced motion and deformation of both targets and organs at risk (...

Reduction of the Charge Build-up Effect on the Beam Current Transformers for Real-Time Monitoring of Ultra-High Dose per-Pulse Electron Beams

Authors: Wesley S. Culberson, Miguel Angel Flores Mancera, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Beam current transformers (BCTs) are a promising alternative to ion chambers for real-time monitoring of ultra-high dose per-pulse (UHDPP) beams. The signal of the BCT is insensitive to ion r...

Routine Quality Monitoring in Abdominal CT Using Global Noise Reference Levels in a 4-Parameter Protocol Summary Plot

Authors: Joke Binst, Hilde TC Bosmans, Niki Fitousi, Bram Miseur, Dimitar Petrov, Kwinten Torfs, Janne Vignero

Affiliation: Qaelum NV, Department of radiology, UZLeuven, Department of imaging and pathology, KULeuven

Abstract Preview: Purpose: Routine quality monitoring in CT abdomen is crucial for ensuring optimal image quality and patient safety, but the simultaneous evaluation of all aspects of importance is challenging. The pur...

Single Plane Positioning Tracking Proton and Helium Pencil Beam Radiographs: Phantom Study

Authors: Anahita Bakhtiari Moghaddam, Don F. DeJongh, Ethan DeJongh, Jennifer Hardt, Oliver Jäkel, Lukas Martin, Alexander Pryanichnikov, Joao Seco, Christina Stengl, Niklas Wahl

Affiliation: Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Division of Biomedical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), ProtonVDA LLC, Department of Physics and Astronomy, Heidelberg University, Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT)

Abstract Preview: Purpose:
To evaluate the feasibility and performance of single-plane position tracking for proton and helium pencil beam radiography using a prototype imaging system, with the goal of providing a c...

Small Fields Output Factor Measurements in 1.5 MR-Linac

Authors: Thomas I. Banks, Tsuicheng D. Chiu, Viktor M. Iakovenko, Christopher Kabat, Chang-Shiun Lin, Mu-Han Lin, Arnold Pompos

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX

Abstract Preview: Purpose: The superior soft-tissue contrast provided by MR imaging offers favorable conditions for the effective application of stereotactic body radiation therapy (SBRT). Accurate small field dosimetr...

Spectral CT Assessment of 3D Printing Techniques for Improving the Uniformity and Reproducibility of Models Applied in Medical Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: Filament deposition modeling (FDM) 3D printers may utilize proprietary calibration methods inadequate for medical imaging. Proper techniques are necessary to achieve imaging uniformity standa...

Streamlined Calibration of Mosfet Dosimeters for Radixact Systems: Addressing Angular Dependence and Beam Profile Challenges

Authors: Guang-Pei Chen, Renae Conlin, Juan A. Garcia-Alvarez, Kirk Morris, Haidy G. Nasief, Eenas A. Omari, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Cumulative dose limits make replacing and calibrating Metal Oxide Semiconductor Field Effect dosimeters (MOSFET-d) used for in-vivo dosimetry a common clinical task. Calibration protocols for...

To Establish Local Diagnostic Reference Levels (DRLs) for Head and Neck Computed Tomography (CT) Exams in Abuja, Nigeria, and to Investigate the Performance of Brain Metastasis (BM) and Brain Lesion (BL) Segmentation Techniques Using U-Net Models.

Authors: Nuraddeen Nasiru Garba, Kalpana M Kanal, Abdullahi Mohammed, Rabiu Nasiru, Muhammad SHAFIU Shehu, Daniel Vergara, Joseph Everett Wishart

Affiliation: AHMADU BELLO UNIVERSITY, ZARIA, University of Washington

Abstract Preview: Purpose: To establish local Diagnostic Reference Levels (DRLs) for head and neck computed tomography (CT) exams in Abuja, Nigeria, and to investigate the performance of brain metastasis (BM) and brain...

Towards Higher Quality Breast Radiotherapy Treatments: A First Evaluation of the Newly Introduced Inframammary Fold Breast Wedge™ Device from Qlrad

Authors: Thomas Furno, Arjen Winkel, Ramtin Zakikhani

Affiliation: Genesis Care USA, QLRAD, SMH

Abstract Preview: Purpose: To quantify the dosimetric impact of the newly introduced “Inframammary Fold (IMF) Breast WedgeTM ” device by QLRAD inc. in the region of the inframammary fold during breast radiotherapy.
...

Validation of Synthetic CT-Based Online Monitoring for Adaptive Proton Therapy

Authors: Ozgur Ates, Chin-Cheng Chen, Chia-Ho Hua, Matthew J. Krasin, Thomas E. Merchant

Affiliation: St. Jude Children's Research Hospital

Abstract Preview: Purpose: To validate the use of synthetic CTs generated from CBCT images for online monitoring, ensuring accurate and reliable daily plan quality assessments in adaptive proton therapy (APT).
Metho...

Validation of a Simulation Tool and in-Silico Assessment of Low Contrast Detectability for Super-Resolution Deep Learning Reconstruction

Authors: Naruomi Akino, Kirsten Lee Boedeker, Ilmar Hein, Akira Nishikori, Daniel W Shin

Affiliation: Canon Medical Systems Corporation, Canon Medical Research USA

Abstract Preview: Purpose: To validate a simulation tool using physics-based image quality metrics in both phantom and patient data, and to assess the low contrast detectability (LCD) of Super Resolution-Deep Learning ...

Variations in Automatic Dose Response Curves across Fluoroscope Types and Manufacturers for Abdominal Imaging

Authors: Hadley Anna DeBrosse, Edward J. Stafford, Kevin A. Wunderle

Affiliation: Ohio State University, The Ohio State University

Abstract Preview: Purpose: To investigate automatic dose response curves from fluoroscopes across multiple manufacturers for an abdominal imaging protocol.
Methods: ADRC response for multiple fluoroscopes were evalu...

Water-Equivalent Thickness Mapping (WET-MAP) – a Potential Alternative to 4D Robust Optimization for Motion Management in Proton Treatment Planning

Authors: Duncan Henry Bohannon, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, Ahmal Jawad Zafar, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose:
4D robust optimization, incorporating additional images (e.g., maximum inhale/exhale phases), is commonly used to account for target motion in proton treatment planning. However, the incre...