Search Submissions 🔎

Results for "whole body": 92 found

4π Non-Coplanar Stereotactic Body Radiation Therapy: Dosimetric Evaluation of VMAT Configurations in for Recurrent Head and Neck Tumors

Authors: Sixue Dong, Weigang Hu, Jiazhou Wang, Zhen Zhang

Affiliation: Fudan University Shanghai Cancer Center

Abstract Preview: Purpose: This study aimed to evaluate the dosimetric benefits and treatment efficiency of different beam configurations in 4π non-coplanar VMAT for SBRT in recurrent head and neck tumors

Method...

A Beagle Dog Mesh-Type Phantom for Application to Nuclear Medicine and Internal Dosimetry

Authors: Wesley E. Bolch, Natalia Estefania Carrasco-Rojas, Chansoo Choi, Robert Joseph Dawson, Aitor Gallastegui Menoyo, Rowan James Milner, Bangho Shin, Maria M. Von Chamier

Affiliation: University of Florida

Abstract Preview: Purpose: To develop a tetrahedralizable mesh-type phantom of a male beagle dog to later perform Monte Carlo radiation transport simulations and calculate organ doses using monoenergetic photons, elect...

A Dosimetric Investigation into the Potential of Aperture-Based Techniques to Improve the Clinical Outcomes of Single-Energy Proton Bragg Peak Flash Therapy for Ocular Cancers

Authors: Arpit M. Chhabra, J Isabelle Choi, Minglei Kang, Haibo Lin, Hang Qi, Charles B. Simone, Shouyi Wei, Irini Yacoub, Francis Yu, Xingyi Zhao, Ajay Zheng

Affiliation: New York Proton Center, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose:
Pencil beam scanning (PBS) proton therapy effectively treats ocular cancer by minimizing exit doses to normal tissues. However, challenges remain in sparing nearby organs-at-risk(OARs). Ul...

A Ground Truth Label-Mediated Method for Improved Bone and Gas Cavity Definition for MRI-Guided Online Adaptive Radiotherapy Workflows Using Synthetic CT Images.

Authors: Benito De Celis Alonso, Braian Adair Maldonado Luna, Gerardo Uriel Perez Rojas, René Eduardo Rodríguez-Pérez, Kamal Singhrao

Affiliation: Department of Radiation Oncology, Brigham and Women's Hospital, Dana Farber Cancer Institute, Harvard Medical School, Faculty of Physics and Mathematics, Benemérita Universidad Autónoma de Puebla

Abstract Preview: Purpose: Artificial Intelligence (AI)-generated synthetic CT (sCT) images can be used to provide electron densities for dose calculation for online adaptive MRI-guided stereotactic body radiotherapy (...

A Knowledge-Based Approach for High-Quality Accelerated Partial Breast Irradiation Using Stereotactic Body Radiotherapy

Authors: Drexell Hunter Boggs, Carlos E. Cardenas, Allison Dalton, John B Fiveash, Joel A. Pogue, Richard A. Popple, Farnaz Rahim Li

Affiliation: The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: External-beam Accelerated Partial Breast Irradiation (APBI) using stereotactic-body radiotherapy (SBRT) is increasingly adopted as an alternative to whole-breast radiation, offering targeted ...

A Mechatronic Biopsy Guidance System for an Integrated 3D TRUS with Prostate-Specific PET System

Authors: Jeffrey Bax, Ian A. Cunningham, Aaron Fenster, Lori Gardi, Sule Karagulleoglu Kunduraci, Alla Reznik, David Tessier

Affiliation: Robarts Research Institute, Imaging Research Laboratories, Robarts Research Institute, Lakehead University

Abstract Preview: Purpose: Image-guided biopsy is critical for early diagnosis of prostate cancer (PCa), the most common cancer in men worldwide. While the prostate-specific PET (P-PET) system offers enhanced sensitivi...

A Quantitative Analysis of Interplay Effects in IMPT for Lung Cancer SBRT: Comparing Two Machine Delivery Sequence Models

Authors: Xiaoda Cong, Xuanfeng Ding, Gang Liu, Peilin Liu, Lewei Zhao

Affiliation: Department of Radiation Oncology, Stanford University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Corewellhealth William Beaumont University Hospital

Abstract Preview: Purpose: This study quantitatively evaluates the interplay effect in intensity-modulated proton therapy (IMPT) for lung cancer stereotactic body radiotherapy (SBRT) using two different machine deliver...

An Adaptive Radiotherapy Approach Sparing Preirradiated Critical Structures

Authors: Mohamed Bahaaeldin Mohamed Afifi, Lili Chen, Xiaoming Chen, Ahmed A. Eldib, Chang Ming Charlie Ma, Robert A. Price

Affiliation: Fox Chase Cancer Center, Radiological Sciences and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University.

Abstract Preview: Purpose: Reirradiation of recurrent cancer or a newly developed lesion in a proximal location poses a challenge for radiation treatments. This is occasionally encountered in many modern clinics and ef...

An Analytical Framework to Quantify the Effect Obstructing Anatomical Features in Intrafractional Spectral Imaging Using a Dual-Layer Kv Imager

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Marios Myronakis

Affiliation: Medical Physics Department, Medical School, University of Thessaly, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory

Abstract Preview: Purpose:
Dual-layer kV imager (DLI) architecture enables the capability for single-shot dual-energy (DE) intrafraction imaging. As noise from individual DLI layers are primarily uncorrelated, simpl...

Assessing the Impact of Intrafraction Shifts on Critical OAR Doses in a Standardized Spine SBRT Program

Authors: Daniel A. Alexander, Anish Butala, Anthony Austin Kassaee, Neil Malhotra, Ian Messing, Gabrielle W Peters, Ryan M. Scheuermann

Affiliation: Department of Radiation Oncology and Applied Sciences, University of Pennsylvania

Abstract Preview: Purpose: Stereotactic Body Radiation Therapy (SBRT) for spinal metastases uses CBCT-based localization and highly conformal treatment delivery to increase the biologically equivalent dose to the targe...

Assessing the Need for Online Adaptive Prostate SBRT Using the MR-Linac

Authors: Awens Alphonse, Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Samuel Richter, Lauren A. Rigsby, Tino Romaguera, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: This study evaluates the necessity and potential benefits of online adaptive stereotactic body radiotherapy (SBRT) for prostate cancer using the ViewRay MR-Linac system. By leveraging real-ti...

Assessing the Potential of Remote Navigation Systems to Mitigate GI Toxicity in Abdominal SBRT

Authors: Justus Adamson, Wesley Andrew Cunningham, Caleb Logan Smith

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: Radiation induced bowel toxicity is a persistent issue for abdominal Stereotactic Body Radiation Therapy (SBRT). Remote magnetic navigation systems (RMNS) have been developed for use in magne...

Bayesian Mixture Modelling of Apparent Diffusion Coefficients from Whole-Body MRI Reveals Significant Changes in Metastatic Lesions Treated with Stereotactic Body Radiotherapy Compared to Untreated Controls

Authors: Giacomo Avesani, Matthew D Blackledge, Silvia Bottazzi, Alison Tree, Nina Tunariu

Affiliation: Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Institute of Cancer Research, The Royal Marsden NHS Foundation Trust

Abstract Preview: Purpose: To evaluate changes in median apparent diffusion coefficient (ADC) within metastatic oligoprogressing lesions from prostate cancer treated with stereotactic body radiotherapy (SBRT) and compa...

Biomechanically Informed Diagnostic-to-Synthetic CT Transformation for Expedited Radiation Therapy Planning

Authors: Liyuan Chen, Steve Jiang, Chenyang Shen

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center

Abstract Preview: Purpose: Delays in radiation therapy (RT) initiation caused by conventional CT simulation processes can hinder timely treatment delivery and patient outcomes. This study proposes a Virtual Treatment S...

Brain Structural Covariance Networks in Nicotine-Dependent Users: A Graph Analysis

Authors: Humberto Monsivais, Brian A. Taylor, Francesco Versace

Affiliation: Purdue University, Department of Behavioral Science, Division of Cancer Prevention and Population Sciences, The University of Texas MD Anderson Cancer Center, Department of Imaging Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: To identify possible signatures of altered brain morphometry in nicotine-dependency via a structural covariance network approach.

Methods: Fifty-one healthy controls (HC:27M, mean age=...

Breastplan-Helper: Publicly Shared Source Scripting Toolset to Assist in 3D Breast Planning

Authors: Ryan Clark, Anthony Magliari, Luis Felipe Oliveira E Silva, Yang Sheng, Jason R Vickress, Qingrong Jackie Wu, Giulianne Rivelli Rodrigues Zaratim

Affiliation: Verspeeten Family Cancer Center, Office of Medical Affairs, Varian, A Siemens Healthineers Company, Confiar Radioterapia, Duke University Medical Center

Abstract Preview: Purpose: Develop a toolset to replace several of the tedious steps required to manually generate 3D breast treatment plans using static gantry forward planned tangent beams.

Methods: Eclipse Sc...

Clinical Factors Associated with Urinary Morbidity in Men Undergoing Combination Prostate Radiation Therapy

Authors: James Benton, Andrew Dewar, Benjamin C Lee, Ryan Y Lee

Affiliation: Radiotherapy Clinics of Georgia, Urology of Greater Atlanta

Abstract Preview: Purpose:
The purpose of our investigation was to determine if pre-treatment factors could predict urinary morbidity after combination radiation treatment for localized prostate cancer.
Methods:<...

Commissioning a Comprehensive Workflow for VMAT Total Body Irradiation (TBI) Using Publicly and Commercially Available Resources

Authors: Alan H. Baydush, Sarah Cummings, Jeffrey Michael Fenoli, Christy Hickerson, Lalith Kumaraswamy, Philmo Oh, Sarah B. Wisnoskie

Affiliation: Novant Health Cancer Institute, Novant Health

Abstract Preview: Purpose: To develop, validate, and commission a VMAT Total Body Irradiation (TBI) workflow by integrating publicly available resources, commercial solutions, and in-house testing to enhance treatment ...

Comparison of Dose Metrics to Critical Heart Substructures for Different Planning Techniques, and Scan Techniques for Right Sided Breast Irradiation

Authors: Wesley A. Belcher, Aidan Burke, Matthew Green, Taylor Stamey

Affiliation: ECU Health, East Carolina University Brody School of Medicine

Abstract Preview: Purpose: The purpose of this study was to determine the effect of using deep inhalation breath hold (DIBH) vs. free breathing (FB) and intensity-modulated radiation therapy (IMRT) vs. 3D for right-sid...

Comprehensive Analysis of Plan Modulation in SRS/SBRT Plans: A Single Institution Study of 461 Cases

Authors: Yunfeng Cui, Will Giles, Xinyi Li, Ke Lu, Jennifer C. O'Daniel, Anna E. Rodrigues, Chunhao Wang, Lana Wang, Yibo Xie, Sua Yoo, Jingtong Zhao

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose:
To establish quantitative measurement of plan modulation for SRS/SBRT treated with Volumetric Modulated Arc Therapy (VMAT) on C-arm LINACs.
Methods:
A total of 461 plans were analyze...

Consecutive Daily Fractions with Itv Boost Are Safe for Treating Central Non-Small Cell Lung Cancer Using Stereotactic Body Radiation.

Authors: Baher Elgohari, M. Saiful Huq, Ronald John Lalonde, Fang Li, Noor Mail, Jeonghoon Park, Tyler Wilhite

Affiliation: UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, UPMC Hillman Cancer Center, UPMC, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
To compare toxicity between consecutive-daily (QD) with every-other-day (QoD) delivery of lung stereotactic-body-radiation (SBRT) for central non-small-cell lung cancer (NSCLC).
Methods...

Cumulative Doses in Radiotherapy Treatment of Lymphoma Patients

Authors: Klaus Bacher, Tom Boterberg, Jeff Rutten, Barbara Vanderstraeten, Gwenny Verfaillie, Sarah Waelkens

Affiliation: Ghent University, Ghent University Hospital

Abstract Preview: Purpose: Lymphoma cancer patients frequently receive ionizing radiation during their treatment trajectory, including diagnostic CT, planning CT (pCT), recurrent CBCTs, radiotherapy (out-of-field) dose...

Dependency of CT Number on Position in the Field-of-View for Single- and Multi-Energy Images Acquired with Energy-Integrating-Detector and Photon-Counting-Detector CT Scanners

Authors: Yanle Hu, Shuai Leng, Cynthia H. McCollough, Maryam Sadeghian, Joe Swicklik

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: To assess the dependency of CT numbers on position in the field-of-view (FOV) using single-energy (SE) and dual-energy (DE) images and energy-integrating detector (EID) and photon-counting de...

Development of Patient-Specific Lead Ball Compensator for Total Body Irradiation

Authors: Chang Heon Choi, Minjae Choi, Yoonsuk Huh, Jin Jegal, Jung-in Kim, So-Yeon Park

Affiliation: Department of Radiation Oncology, Veterans Health Service Medical Center, Department of Radiation Oncology, Seoul National University Hospital

Abstract Preview: Purpose: Total Body Irradiation (TBI) aims to achieve a uniform dose distribution across the entire body. However, in conventional TBI setups that use extended source-to-surface distance (SSD) and lea...

Development of a Novel 3D-Printed Heterogeneous Phantom for Liver SBRT Dose Verification in Hepatocellular Carcinoma (HCC) Treatment.

Authors: Dr. Sheaka Alobaidli, Anju K V, Dr. Chiranjib Konar, Sreejesh MS, Dr. Vijayaprabhu N, Dr. Deepti Sharma, Dr. Hanuman Prasad Yadav

Affiliation: Amity Institute of Applied Sciences, Kuwait Cancer Control Center, Institute of Liver and Biliary Sciences, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Amity institute of Applied Sciences, Amity University, Institute of Liver and Biliary Sciences(ILBS)

Abstract Preview: Purpose:
The accuracy of dose delivery in stereotactic body radiotherapy (SBRT) is critical for effectively treating hepatocellular carcinoma (HCC). This study aims to develop patient-specific 3D-p...

Development of a Whole-Body Blood Flow Framework Based on the Icrp Blood Phantom

Authors: Jung Han Nam, Wonmo Sung

Affiliation: Department of Biomedical Engineering and Biomedicine & Health Sciences, College of Medicine, The Catholic University of Korea, Department of Biomedical Engineering and Biomedicine & Health Sciences, College of Medicine, The Catholic University of Korea, Seoul, Korea

Abstract Preview: Purpose: This study aims to develop a whole-body blood flow framework based on the ICRP 145 standard vascular phantom to simulate the spatiotemporal trajectories of blood cells in the human vasculatur...

Dosimetric Comparison of MR-Linac Vs. Cyberknife for Prostate Stereotactic Body Radiation Therapy

Authors: Awens Alphonse, Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: Prostate stereotactic body radiation therapy (SBRT) requires precise dose delivery to the target volume and organ-at-risk (OAR) sparing. This study compares MR-Linac (MRL) and CyberKnife (CK)...

Dosimetry Commissioning of a Commercial Cabinet X-Ray Irradiator for Small Animal Irradiation

Authors: Sang Hyun Cho, Amrit Kaphle, Sunil Krishnan, Neerajan Nepal

Affiliation: The University of Texas MD Anderson Cancer Center, The University of Texas Health Science Center

Abstract Preview: Purpose: To determine the basic dosimetry parameters and characteristics of a commercial cabinet x-ray unit for small animal irradiation as well as the specific dosimetry parameters for concurrent irr...

Dosinme: A 3D Visualization Platform for Internal Dosimetry and Radionuclide Behavior in Computational Human Phantoms

Authors: Lotem Buchbinder Shadur, Shaheen Dewji, Martin Graffigna, Alejandro Rafael Martinez, Emmanuel Mate-Kole, Antonio McClain, Samuel Taylor, Jeffrey Wang

Affiliation: Student, Nuclear and Radiological Engineering and Medical Physics Programs, Georgia Institute of Technology

Abstract Preview: Purpose: DosInMe is an internal dosimetry visualization tool developed by the Radiological Engineering, Detection, and Dosimetry Laboratory at Georgia Tech to assist researchers and professionals in v...

EPR Oximetry for Hypoxia Assessment in Deep Tissues Using Oxytrack

Authors: Maciej M. Kmiec, Periannan Kuppusamy, Ryan C. O'Connell, Sergey V. Petryakov, Conner Ubert

Affiliation: Dartmouth College

Abstract Preview: Purpose: The rigid needle-like EPR sensor, OxyTrack, was developed to provide minimally invasive, reliable, and quantitative measurements of oxygen distribution (pO2) in deep tissues. EPR oximetry's c...

Early Imaging Identification of Osteoradionecrosis and Classification Using the Novel Clinrad System

Authors: Serageldin Attia, Zayne Belal, Cem Dede, Clifton David Fuller, Andrew Hope, Laia Humbert Vidan, Kate Hutcheson, Zaphanlene Kaffey, Stephen Y. Lai, Abdallah Mohamed, Amy Moreno, Jillian Rigert, Erin Watson

Affiliation: Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Department of Head and Neck Surgery, The University of Texas MD Anderson Cancer Center, Princess Margaret Cancer Centre, University Health Network, 610 University Ave., The University of Texas MD Anderson Cancer Center, UT MD Anderson, Princess Margaret Cancer Centre, UT MD Anderson Cancer Center, Hospital of the University of Pennsylvania, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Head and Neck Surgery, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology

Abstract Preview: Purpose: Osteoradionecrosis (ORN) of the jaw is a debilitating radiation-induced toxicity lacking standardized classification criteria or treatment guidelines. Early identification of tissue injury co...

Effects of Enhanced Leaf Modeling on Single-Isocenter Multi-Target Stereotactic Radiosurgery Dose Accuracy

Authors: Thomas R. Mazur, Kevin Renick, Matthew C. Schmidt, Xiaodong Neo Zhao

Affiliation: Washington University in St. Louis School of Medicine, Washington University School of Medicine

Abstract Preview: Purpose: To compare dose calculation accuracy for single-isocenter multi-target stereotactic radiosurgery plans (SIMT-SRS) in Eclipse V18.0 with enhanced leaf model (ELM) using the anisotropic analyti...

Enhancing Proton Treatment and Mitigating Radiation-Induced Lung Injury Using a Novel Cycle Diffusion Approach for Lung Ventilation Estimation

Authors: Yang Lei, Haibo Lin, Tian Liu, Charles B. Simone, Shouyi Wei, Ajay Zheng

Affiliation: Icahn School of Medicine at Mount Sinai, New York Proton Center

Abstract Preview: Purpose: Radiation-induced lung injury (RILI), encompassing pneumonitis and fibrosis, represents a critical dose-limiting factor in lung cancer radiation therapy. Variability in treatment outcomes is ...

Enhancing Synthetic Pelvic CT Images from CBCT Using Vision Transformer with Adaptive Fourier Neural Operators

Authors: Rashmi Bhaskara, Oluwaseyi Oderinde

Affiliation: Purdue University

Abstract Preview: Purpose: This study proposes a novel approach to overcoming CBCT image quality limitations by developing an improved synthetic CT (sCT) generation method based on a CycleGAN architecture using Vision ...

Enhancing Urethral Visualization for Prostate SBRT Using Post-Void T2-Weighted Imaging on a Low-Field 0.35T MR-Linac System

Authors: Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: Accurate delineation of the urethra is critical for optimizing tumor control and minimizing urethral toxicity in prostate stereotactic body radiation therapy (SBRT). The purpose of this study...

Estimating Organ Dose of Standard Pediatric CT Protocols to Computational Phantoms through the Dukesim CT Simulator

Authors: Dean Darnell, Iyanna M Lewis, Francesco Ria, William Paul Segars

Affiliation: Duke University, Duke University Medical Physics Graduate Program, Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories and Center for Virtual Imaging Trials, Duke University Medical Center, Duke University Medical Center

Abstract Preview: Purpose: To estimate radiation dose to pediatric patients during standard CT imaging of the chest and abdomen and determine how dose varies with patient age, height and weight and how measurements com...

Evaluating Normal Tissue Toxicity Following Pulsed Low Dose Rate Radiotherapy

Authors: Shahabeddin mostafanazhad Aslmarand, Lili Chen, Dusica Cvetkovic, Troy A. Dos Santos, Chang Ming Charlie Ma, Dae-Myoung Yang

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose:
Pulsed low-dose-rate radiotherapy (PLDR) has been proposed to reduce normal tissue toxicity while maintaining tumor control comparable to conventional radiotherapy (CRT). This study assess...

Evaluating PET-Based Metrics to Identify Patients with Liver Metastases for Biology-Guided Radiotherapy

Authors: Girish Bal, Ke Colin Huang, Christopher F. Njeh, Oluwaseyi Oderinde, Yong Yue

Affiliation: Purdue University, RefleXion Medical, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) uses real-time positron emission tomography (PET) signals to precisely direct radiotherapy beamlets. The success of BgRT planning and delivery relies on PET...

Evaluating the Radiological Safety of 64Cu-Macrin in PET/MRI Studies through Radiopharmaceutical Dosimetry

Authors: Alejandro Bertolet, Mislav Bobić, Carlos Huesa-Berral, Aileen O'Shea, Ralph Weissleder

Affiliation: Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: To develop a pipeline for estimating the absorbed dose to various organs from positron emission tomography (PET) combined with magnetic resonance imaging (MRI). We use this pipeline to evalua...

Evaluation of Treatment Delivery Efficiency and Workflow Optimization in Prostate Stereotactic Body Radiation Therapy: A Comparative Study of C-Arm and O-Ring Linear Accelerators

Authors: Yijian Cao, Jenghwa Chang, Lyu Huang

Affiliation: Northwell, Hofstra University Medical Physics Program

Abstract Preview: Purpose: This study evaluates the treatment delivery efficiency and workflow of two advanced linear accelerator systems—Varian’s TrueBeam (C-arm) and Halcyon (O-ring)—for prostate Stereotactic Body Ra...

Evaluation of Treatment Planning Feasibility and Dosimetric Quality of the Reflexionℱ X1 System for Complex Spinal Targets

Authors: Thomas I. Banks, Bin Cai, Andrew R. Godley, Yang Kyun Park, Hao Peng, Rameshwar Prasad, Chenyang Shen, Shunyu Yan, Haozhao Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose:
The RefleXionÂź X1 (RefleXion Medical, Inc., Hayward, CA) uniquely integrates KVCT and PET as on-board image guidance for radiotherapy. It has been installed and commissioned for clinical u...

Eye-Tracking Analysis of Radiologist Preferences in PET Imaging: Comparing 5-Ring and 6-Ring Detector Configurations

Authors: Samuel L. Brady, Joseph G. Meier, Elanchezhian Somasundaram, Andrew T Trout

Affiliation: Cincinnati Children's Hospital Medical Ctr, Cincinnati Childrens Hospital Med Ctr

Abstract Preview: Purpose:
To analyze eye-tracker gaze data for insights into radiologists’ areas of focus in an observer study of whole-body PET images.
Methods:
For a comparative study of dose matched PET im...

Functional Liver Image Guided Radiation Planning Using MRI with a Contrast Agent

Authors: Kenneth L. Homann, Natalie A Lockney, Hong Zhang

Affiliation: Department of Radiation Oncology, Vanderbilt University Medical Center, Vanderbilt University Medical Center

Abstract Preview: Purpose: The aim of this study is to develop a treatment planning methodology utilizing liver functional imaging via contrast-enhanced Magnetic Resonance Imaging (MRI) in patients undergoing stereotac...

Head and Neck Treatment Evaluation with Cone Beam Computed Tomotherapy

Authors: Varsha Jain, Jun Kang, Paul Sulivan, Kate E. Verma, Yevgeniy Vinogradskiy

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose:
Patients undergoing treatment for head and neck(H&N) cancers experience significant body contour changes throughout treatment. Body contour changes are due to tumor shrinkage, weight loss,...

High Resolution Head Motion Correction Based on Pilot Tone Signals – a Calibration-Free Method

Authors: Cheng-Chieh Cheng, Jeffrey P Guenette, Yajun Li, Bruno Madore, Lei Qin

Affiliation: Brigham and Women's Hospital, National Sun Yat-sen University, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Pilot tone (PT), a compact RF sensor, has been integrated into clinical practice for motion detection. Prior studies proposed mapping PT signals to head positions using a calibration step tha...

High-Fidelity Treatment Optimization for Online Adaptive Stereotactic Partial Breast Irradiation: Integrating Dose and Treatment Time Considerations

Authors: Drexell Hunter Boggs, Carlos E. Cardenas, Jingwei Duan, Joseph Harms, Joel A. Pogue, Richard A. Popple, Courtney Bosse Stanley, Dennis N. Stanley, Sean Xavier Sullivan, Natalie N. Viscariello

Affiliation: Washington University in St. Louis, The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: CBCT-guided online adaptive radiation therapy (OART) with Ethos for stereotactic accelerated partial breast irradiation (APBI) can mitigate inter-fraction variation, leading to dosimetric adv...

Hybrid Prior-Enhanced Deep Image Prior (HPEDIP) Image Reconstruction for Ultra-Short Scans

Authors: Renee Farrell, Jinkoo Kim, Xin Qian, Ziyu Shu, Zhaozheng Yin, Tiezhi Zhang

Affiliation: Stony Brook Medicine, Washington University in St. Louis, Stony Brook University, Stony Brook University Hospital

Abstract Preview: Purpose: Ultra-short CT scan allows fast imaging speed, dose reduction, and compact system design. We developed a deep image prior (DIP) based reconstruction method named Hybrid Prior-Enhanced Deep Im...

HypersightÂź Offline Adaptive Workflow

Authors: Doris Dimitriadis/Dimitriadou, Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Noor Mail, Adam Olson, Tyler Wilhite

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, UPMC

Abstract Preview: Purpose: The goal of the HyperSightÂź offline adaptive-workflow is to create a methodical approach to adaptive-radiotherapy (ART) that considers modifications in patient setup and anatomy. Through effi...

Impac of Respiratory Motion on Dosimetric and Biological Outcomes in Lung Cancer SIB-SBRT: A 4D Dose Calculation Approach

Authors: Xiangli Cui, Lingling Liu

Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Cancer Hospital, Chinese Academy of Sciences

Abstract Preview: Purpose:
Respiratory motion introduces substantial dose uncertainties in lung cancer radiotherapy, particularly affecting dose distribution in Simultaneous Integrated Boost-Stereotactic Body Radiot...

Impact of Patient Setup Errors on the MR Linac-Based SBRT Treatment for Prostate Cancer

Authors: Awens Alphonse, Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: In radiation therapy, patient setup errors have been a primary concern impacting dose delivery accuracy. A robust treatment plan is essential to mitigate these errors. This study aimed to eva...

Impact of Physics Modeling on Monte Carlo Normal Tissue Dose Reconstructions for Passive Scattering Proton Therapy Patients

Authors: Caroline Esposito, Keith T Griffin, Jae Won Jung, Choonik Lee, Choonsik Lee, Matthew Mille, Harald Paganetti, Sergio Morato Rafet, Jan PO Schuemann, Jungwook Shin, Torunn I Yock

Affiliation: East Carolina University, University of Michigan, Massachusetts General Hospital, National Cancer Institute, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: The National Cancer Institute’s Pediatric Proton and Photon Therapy Comparison Cohort aims to collect and analyze data from cancer centers across the United States and Canada to quantify diff...

Improving Adversarial Approaches to Synthetic CT Image Generation with Skin Surface Masks

Authors: Mahya Ahmadzadeh, Nagarajan Kandasamy, Keyur Shah, Gregory C. Sharp, Santhosh Vadivel, John MacLaren Walsh

Affiliation: Electrical and Computer Engineering Department, Massachusetts General Hospital, Emory University, Drexel University

Abstract Preview: Purpose: In image-guided radiotherapy (IGRT), cone beam CTs (CBCTs) suffer from distortions that degrade registration with planning CTs. While CycleGANs can generate synthetic CTs (sCTs) from CBCTs, e...

Innovative Design and Simulation of a Pediatric-Dedicated SPECT: Enhancing Imaging Performance for a Healthier Scans in Children

Authors: Mohammadreza Ay, Nahal Daneshgar, Nima Kasraie, Abbas Monsef, Zeinab Peymani, Hadi Rezaei, Peyman Sheikhzadeh

Affiliation: University of Minnesota Medical School, Radiation Oncology, Department of Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences, Shiraz University of Medical Sciences, Department of Medical Physics, Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, UT Southwestern Medical Center, Imam Khomeini Hospital Complex,Tehran University of Medical Sciences

Abstract Preview: Purpose:
This study aims to design and simulate an innovative pediatric-dedicated SPECT scanner optimized for children’s unique anatomical and safety needs by enhancing sensitivity in data acquisit...

Integrating Clinical Knowledge Via Llms for Precise Organ-at-Risk Segmentation in Pancreatic Cancer SBRT

Authors: Karyn A Goodman, Yang Lei, Tian Liu, Pretesh Patel, Jing Wang, Kaida Yang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: This study aims to improve organ-at-risk (OAR) segmentation in pancreatic cancer stereotactic body radiotherapy (SBRT) by integrating clinical guidelines into deep learning workflows. We use ...

Intra-Organ Blood Vessel Mapping in Mice for Improved Pre-Clinical Radiation Dosimetry

Authors: Daylin Barroso, Chris Beekman, Wesley E. Bolch, Natalia Estefania Carrasco-Rojas, Robert Joseph Dawson, Walter Murfee, Harald Paganetti, Andrew Robert Sforza, Julia D. Withrow

Affiliation: Massachusetts General Hospital - Harvard Medical School, Massachusetts General Hospital, University of Florida

Abstract Preview: Purpose: To develop methods for quantifying the interaction of radiation with blood in the mouse whole body (MOBY) phantom for dosimetric applications. The most important of these are modeling the dis...

Investigating the Flash Effect: Uncovering Brain Sparing and Cognitive Preservation across Varying Dose Rates in Whole-Brain Irradiation of in-Vivo Mouse Models

Authors: Denise Dunn, Scott R. Floyd, Tyler V. Kay, Anna Lynnette-Price, Eric L. Martin, Stepan Mikhailov, Taylor Nguyen, Mark Oldham, Victoria J. P. Radosova, Zachary J. Reitman, Ramona Rodriguiz, Andrew Thompson, William Wetsel, Seth Wilcox, Ying Wu

Affiliation: Duke University Mouse Behavior Core, Department of Physics, Duke University, Medical Physics Graduate Program, Duke University, Duke University Medical Physics Program, Duke University, Duke University Mouse Behavioral and Neuroendocrine Analysis Core Facility, Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: FLASH radiation therapy (RT) shows promise for reducing normal tissue damage, though its mechanisms remain unclear. Using an in-vivo model with the High Intensity Gamma-ray Source (HIGS) lina...

Investigation of High Cumulative Doses and Dose Outliers in a Pediatric Hospital

Authors: Niki Fitousi, Stanley Thomas Fricke, Anna Romanyukha

Affiliation: Qaelum NV, Children's National Hospital

Abstract Preview: Purpose:
To identify opportunities for improvement through investigation of outliers in exam dose length product (DLP) and patients receiving high cumulative doses (CED), in the context of our “ped...

Investigation of Treatment Planning System (TPS) Algorithms for Helical Tomotherapy Total Body Irradiation (TBI)

Authors: John T Barrett, Chulhaeng Huh, Farshad Mostafaei, Michelle Rocque, Austin Sanders

Affiliation: Department of Radiation Oncology, Medical College of Georgia, Augusta University, Department of Radiation Oncology, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health

Abstract Preview: Purpose: This study involved the use of Accuray’s TPS (Precision) and RayStation TPS for planning TBI treatments. TBI was delivered using Accuray’s Radixact machine, and dose calculation algorithm, do...

Key Tumor Volume Zones for Advancing the Radiomics-Based Distant Recurrence Prediction

Authors: Ryan Alden, Tithi Biswas, Kaushik Halder, Felix Maria-Joseph, Michael Mix, Rihan Podder, Tarun Kanti Podder

Affiliation: SUNY Upstate Medical University, IIT-Roorkee, University of Florida

Abstract Preview: Purpose: Radiomics feature-based model for predicting distant recurrence can potentially provide critical insight for clinical decision-making and assistance in treatment strategies. This study focuse...

Longitudinal CMR Strain Analysis of Right Ventricular (RV) Function across Aging in Offspring of Baboons Exposed to Moderate Maternal Undernutrition

Authors: Geoffrey D. Clarke, Laura A. Cox, Alexander J Moody, Peter W Nathanielsz, Bowen Yang

Affiliation: Wake Forest University School of Medicine, University of Texas Health Science Center at San Antonio, Texas Biomedical Research Institute

Abstract Preview: Purpose:
Recent studies show diagnostic value of myocardial strain analysis for left ventricular (LV) function using cardiac magnetic resonance imaging (CMR). RV function analysis is more challengi...

Multicentric Characterization of Organ-Based Tube Current Modulation in Thoracic and Abdominopelvic Computed Tomography: A Dosimetric and Image Quality Study

Authors: Corentin Desport, Dominique Iacchetti, Nicolas Kien, Ramiro Moreno, Melodie Munier, Séléna Pondard

Affiliation: Fibermetrix, Alara Expertise, Alara Group

Abstract Preview: Purpose: To evaluate the efficiency of organ-based tube current modulation (OBTCM) in thoracic and abdominopelvic Computed Tomography (CT) for different radiology departments and manufacturers. This s...

Noise Sensitivity of Benchmark Whole-Body CT Segmentation Models: Totalsegmentator and Vista3D Performance on an Independent Dataset

Authors: Samuel L. Brady, Shruti Hegde, Alexander Knapp, Usman Mahmood, Joseph G. Meier, Elanchezhian Somasundaram, Zachary Taylor

Affiliation: Cincinnati Children's Hospital Medical Ctr, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Cincinnati Children's Hospital Medical Center, Cincinnati Childrens Hospital Med Ctr

Abstract Preview: Purpose:
To assess how two benchmark multi-organ CT segmentation models respond to varying image noise levels.
Methods:
This study utilized the pediatric CT dataset from The Cancer Imaging Ar...

Optimizing Calibration Radioisotope and Activity for Dose Calibrator Linearity Testing in Radiopharmaceutical Therapy and Theranostic Facilities

Authors: Kimyli Lemieux, Xingyu Nie

Affiliation: University of Kentucky/UK HealthCare

Abstract Preview: Purpose: To optimize the selection of calibration radioisotope and its activity for dose calibrator (DC) linearity testing, adhering to ALARA (As Low As Reasonably Achievable) principles while conside...

Optimizing Lung SBRT Delivery: Role of Multiple Cbcts in Managing Intra-Fraction Motion

Authors: Anthony J. Doemer, Ian Gallagher, Yimei Huang, Jeff A. Riess, Kundan S Thind, Bo Zhao

Affiliation: Henry Ford Health

Abstract Preview: Purpose: Stereotactic body radiation therapy (SBRT) is commonly used for early-stage lung cancer. While pre-treatment CT captures some tumor motion, it may not fully represent intra-fraction motion du...

Parameterized 4D Deformable Registration (p4Dreg) in Abdominal 4DCT Scans

Authors: Edward Robert Criscuolo, Deshan Yang

Affiliation: Duke University, Department of Radiation Oncology, Duke University

Abstract Preview: Purpose:
Deformable registration of 4DCT images has many clinical applications, but current methods are unreliable and can produce dangerous errors. Iterative, parametrized image registration does ...

Performance of Photon Counting Detector in a Clinical PCD-CT: A Novel Image-Based Evaluation

Authors: Frank F. Dong, Megan C. Jacobsen, Ke Li, Xinming Liu, John Rong

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose: We aimed to understand the physical performance of a CdTe PCD-based detector system within a whole-body PCD-CT scanner, with the goal of optimizing its clinical application. Instead of relyin...

Preclinical Dosimetric Evaluation for Small Animal Study to Investigate Normal Tissue-Sparing Effects in the Electron Ultra-High Dose-Rate (FLASH) Environment

Authors: Ashok Bhandari, Andrew Joseph Fanning, Kyle J. Gallagher, Brendan Graff, Christopher Jenkins, Kyuhak Oh, Ying Yan, Su-Min Zhou

Affiliation: University of Nebraska Medical Center

Abstract Preview: Purpose: This study aimed to design a robust experimental setup to ensure accurate dose delivery using ultra-high-dose-rate for small animal experiments by conducting dosimetric evaluations prior to a...

Preliminary Evaluation of Ultrasound-Derived Fat Fraction Reliability in a Pediatric Cohort

Authors: Lizbeth Ayala-Dominguez, Aaron L Carrel, Diego Hernando, Gabrielle L Hoffmann, Amber Possell, Ivan M. Rosado-Mendez, Jiayi Tang, Andrew Wentland

Affiliation: Department of Pediatrics, University of Wisconsin-Madison, Department of Radiology, University of Wisconsin-Madison, Department of Medical Physics, University of Wisconsin-Madison, Departments of Medical Physics and Radiology, University of Wisconsin-Madison

Abstract Preview: Purpose: Metabolic dysfunction-associated steatotic liver disease (MAFLD) is the leading cause of chronic liver disease in children. While biopsy remains the diagnostic standard, non-invasive imaging ...

Prior-Model-Free Dynamic CBCT Reconstruction Via Combined Optical Surface and X-Ray Imaging

Authors: Hua-Chieh Shao, Guoping Xu, You Zhang, Tingliang Zhuang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
Advancements in onboard X-ray hardware allow high-quality CBCT imaging with a short scan time (~6s for Varian HyperSight), enabling CBCT-based dose calculation and treatment planning. Howe...

Protocol for In Vivo Dosimetry Using Myoslchip System: Characterization and Clinical Application

Authors: Jeremy S. Bredfeldt, Daniel W. Cail, Maria A. Czerminska, Cindy I. Hancox, David Hu, Benjamin Karasko, Claire Keun Sun Park

Affiliation: Department of Radiation Oncology, Brigham and Women's Hospital, Harvard Medical School, Brigham and Women's Hospital, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School

Abstract Preview: Purpose: To develop a robust clinical protocol for in vivo dosimetry in radiotherapy using the myOSLchip Optically Stimulated Luminescent Dosimeter (OSLD) system by performing characterization and eva...

Quantitative Image Review Metric for Vertebral Body Misalignment

Authors: Luis E. Fong de los Santos, Douglas John Moseley, Satomi Shiraishi, Cenji Yu

Affiliation: Mayo Clinic

Abstract Preview: Purpose: To quantitatively detect errors in vertebral body localization using normalized cross correlation (NCC)

Methods: Volumetric images of a thoracic end-to-end SBRT phantom with a removabl...

Radiodynamic Therapy: Inhibiting Metastases of Small Cell Lung Cancer In Vivo

Authors: Lili Chen, Andy T. Clark, Dusica Cvetkovic, Chang Ming Charlie Ma, Dae-Myoung Yang

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Radiodynamic therapy (RDT) shows promise as a strategy to inhibit the metastasis of premetastatic small cell lung cancer (SCLC). This study evaluates the therapeutic effect of RDT in inhibiti...

Real-Time 3D Dose Verification for MR-Guided Online Adaptive Radiotherapy (ART) Via Geometry-Encoded Deep Learning Framework

Authors: Steve B. Jiang, Dan Nguyen, Chenyang Shen, Fan-Chi F. Su, Jiacheng Xie, Shunyu Yan, Daniel Yang, Ying Zhang, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Fast dose verification is essential for the safety and efficiency of MR-guided adaptive radiotherapy (ART) as patients anxiously waiting on the treatment couch. Conventional tools often requi...

Regulatory Approval of Mobile Mammography Screening Programs Focused on Underprivileged Communities in Bulgaria.

Authors: Dimitrana Angelova, Gueorgui Gueorguiev, Kremena Ivanova, Filip Simeonov

Affiliation: National Centre of Radiobiology and Radiation Protection

Abstract Preview: Purpose: Mobile mammography screening programs focused on underprivileged populous in Bulgaria, such as the Romani people, are of great importance as such populations often don’t have access or are re...

Reinforcement Learning Based Machine Parameter Optimization for Two-Arc Prostate VMAT Planning

Authors: William T. Hrinivich, Junghoon Lee, Lina Mekki

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins University, Johns Hopkins University

Abstract Preview: Purpose: Volumetric modulated arc therapy (VMAT) planning is a computationally expensive process. In this work, we propose a reinforcement learning (RL) framework to automatically optimize dose rate a...

Retrospective Analysis of Shape and Dosage Changes in Structures during Radiotherapy for Head and Neck Cancer Patients Based on Velocity

Authors: Daming LI, Jinsen Xie, Zhe Zhang

Affiliation: Peking University Shenzhen Hospital Radiotherapy Department, School of Nuclear Science and Technology, University of South China

Abstract Preview: Purpose: To analyze the actual doses received during radiotherapy for head and neck cancers (HNC) using Velocity, providing insights for adaptive radiotherapy decision-making.
Methods: Thirty-three...

S Values for a Monkey Computational Model for Internally Distributed Radiation Sources

Authors: Jae Won Jung, Daniel Lee

Affiliation: Thomas S. Wootton High School, East Carolina University Brody School of Medicine

Abstract Preview: Purpose: Monkeys have played a key role in enhancing our understanding of the behavior of radioactive materials within living organisms in the field of nuclear medicine. However, detailed dosimetric d...

SPECT/CT Multimodal Segmentation of Bone Marrow for Theranostic Dosimetry

Authors: Tommaso Frigerio, Joshua Genender, John M. Hoffman, Catherine (Caffi) Meyer

Affiliation: UCLA, David Geffen School of Medicine at UCLA

Abstract Preview: Purpose: Accurate bone marrow segmentation is required for bone marrow dosimetry to monitor for dangers in PSMA-Lu177 radioligand therapy. We introduce a hybrid (AI/semantic knowledge) segmentation pi...

Scan Efficiency and Imaging Dose Analysis of Next-Generation Nonstop Gated CBCT for Respiratory Gating Lung Radiotherapy

Authors: Sean L. Berry, Weixing Cai, Laura I. Cervino, Yusuf Emre Erdi, Yabo Fu, Yiming Gao, Daphna Gelblum, Wendy B. Harris, Xiuxiu He, Tianfang Li, Xiang Li, Seng Boh Gary Lim, Jean M. Moran, Mitchell Yu, Hao Zhang

Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Gated CBCT (gCBCT) is commonly employed for respiratory gating lung cancer patients to ensure precise patient setup. However, the scan is time-consuming on C-arm linear accelerators (LINAC) d...

Spatial Variation and Dosimetry of X-Ray Contamination in Total Skin Electron Beam Therapy

Authors: William G. Breen, Dalton Griner, Scott C Lester, Joseph John Lucido, Beth A. Schueler, Jack C. Thull

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Designing a total skin electron (TSE) beam therapy protocol requires finding the optimal balance between penetration depth, field uniformity, and x-ray contamination (XC). To better understan...

Stereotactic Body Radiosurgery for Refractory Ventricular Tachycardia: Presenting Efficient Clinic Workflow, Dosimetric Analysis and Patients Reported Clinical Results

Authors: Karam Ayoub, Aaron B Hesselson, Ronald C McGarry, Joshua Misa, Damodar Pokhrel

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Cardiology

Abstract Preview: Purpose: Noninvasive stereotactic body radiosurgery (SBRS) is emerging treatment option for advanced heart failure patients with refractory-ventricular tachycardia (rVT) who experienced recurrent impl...

Streamlining Direct-to-Unit Clinical Set-Ups for Radiation Therapy

Authors: Lori Buchholtz, Alison Garda, Chris L. Hallemeier, Kathryn L. Kolsky, Han Liu, Joseph John Lucido, Marisa Schinter, Andrew J. Veres, Sara Walerak

Affiliation: Mayo Clinic

Abstract Preview: Purpose: The C_START initiative aims to streamline and simplify the Direct-to-Unit (DtU) clinical setup and treatment planning process for photon radiation therapy, particularly for emergent cases suc...

Testing Experience in Dose Monitoring Solutions: Automation Aberrations in Automated Organ Dose Estimation

Authors: Lawrence T. Dauer, Yusuf Emre Erdi, Yiming Gao, Dustin W. Lynch, Usman Mahmood

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Radiation dose to patients in CT examinations (CTDIvol, DLP) is tracked in dose monitoring solutions. Some solutions push for automatically estimating patient organ doses based on exam images...

The Root Cause of Large Differences in Calculated Beam Monitor Units between a Treatment Planning System and a QA Software

Authors: George X. Ding, Kenneth L. Homann

Affiliation: Vanderbilt University Medical Center

Abstract Preview: Purpose: It is standard practice that the beam monitor units (MUs) calculated by a commercial treatment planning system (TPS) is verified by a secondary dose calculation (SDC) software that independen...

Three-Dimensional Reconstruction of Triggered Images with Dehazing Algorithm for Precise Intrafraction Motion Detection in Spine SBRT

Authors: Hyosung Cho, Dae Yup Han, Duhee Jeon, Jiwon Park, Hyesun Yang

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose: To precisely detect intrafraction patient motion during spine stereotactic body radiotherapy (SBRT) treatment delivery, we propose an optimized technique for three-dimensional reconstruction ...

Towards Optimal Target Dose Conformity and Dose Drop-Off: Evaluation of a New Optimization Approach for Biology-Guided Radiotherapy Treatment Planning

Authors: Grant Gibbard, Chunhui Han, An Liu

Affiliation: RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: To evaluate the efficacy of a new approach to streamline treatment planning for biology-guided radiotherapy (BgRT) of fluorodeoxyglucose (FDG)-avid bony lesions on a BgRT machine with real-ti...

Using the Liver Dome for Real-Time Respiratory Motion Adaptive Tracking in Cyberknife Stereotactic Body Radiotherapy (SBRT) for Lung Tumors

Authors: Hulya Ozdemir Buss, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: The CyberKnife (CK) Synchrony system provides sub-millimeter motion-tracking accuracy during stereotactic body radiotherapy (SBRT). For lung tumors near the diaphragm, we evaluated the feasib...

Validation and Benchmarking of Mirdct Software for Organ Dose Estimation in Routine CT Protocols

Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Gunjan Kayal, Adam Leon Kesner, Harry Marquis, Juan Camilo Ocampo Ramos, Stefan Wehmeier

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson

Abstract Preview: Purpose: Accurate organ dose estimation in computed tomography (CT) has gained attention due to the increasing global utilization of CT imaging. MIRDct, a specialized CT dosimetry software, has recent...

Validation of Synthetic CT-Based Online Monitoring for Adaptive Proton Therapy

Authors: Ozgur Ates, Chin-Cheng Chen, Chia-Ho Hua, Matthew J. Krasin, Thomas E. Merchant

Affiliation: St. Jude Children's Research Hospital

Abstract Preview: Purpose: To validate the use of synthetic CTs generated from CBCT images for online monitoring, ensuring accurate and reliable daily plan quality assessments in adaptive proton therapy (APT).
Metho...

Validation of an Open Source Automatic Segmentation Tool for Personalized Dosimetry

Authors: Klaus Bacher, Louise D'hondt, Jeff Rutten, Gwenny Verfaillie

Affiliation: Ghent University

Abstract Preview: Purpose: Manual organ segmentation is a very time-consuming but necessary process in personalized dosimetry. Automatic segmentation tools may alleviate this task. In this study the impact of automatic...

Volumetric-Modulated Arc Therapy (VMAT) Is Associated with Improved Dose Homogeneity, but More Normal Tissue Irradiation Compared to Three-Dimensional Conformal Radiation Therapy (3DCRT) for Breast Cancer

Authors: Laura I. Cervino, Linda X. Hong, Jessica Pagan, Angelica A. Perez-Andujar, Maria Thor

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center, Memorial Sloan-Kettering Cancer Center

Abstract Preview: Purpose: Three-dimensional conformal radiotherapy (3DCRT) and Volumetric-Modulated Arc Therapy (VMAT) are used to treat locally advanced breast cancer. The 3DCRT treatment plans use the treatment fiel...

Whole Heart Sparing Ethos Adaptive Radiotherapy for Lung Cancer

Authors: Ibrahim Aref, David Bergman, Justine M. Cunningham, Payton Dolan, Aharon Feldman, Yimei Huang, Joshua P. Kim, Brett M. Miller, Emily Moats, Benjamin Movsas, Kundan S Thind

Affiliation: Henry Ford Health

Abstract Preview: Purpose: Cardiac radiation dose is directly associated with adverse cardiac events which are predictive of mortality in lung cancer patients. In fractionated lung radiotherapy, studies have shown a hi...