Authors: Hua-Chieh Shao, Chenyang Shen, Jiacheng Xie, Shunyu Yan, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas
Abstract Preview: Purpose: Motion-resolved CBCT imaging, which reconstructs a dynamic sequence of CBCTs reflecting intra-scan motion (one CBCT per x-ray projection), is highly desired for regular/irregular motion chara...
Authors: Rex Carden, Carlos E. Cardenas, Ho-hsin Rita Chang, John B Fiveash, Heinzman A. Katherine, Yogesh Kumar, Gaurav Nitin Rathi, Richard A. Popple, Kayla Lewis Steed
Affiliation: University of Alabama at Birmingham
Abstract Preview: Purpose: Brain metastases (BMs) often require multiple radiotherapy (RT) courses as new lesions appear. Comparing follow-up imaging with prior RT plans is time-intensive. We developed an AI tool that ...
Authors: Laura A. Doyle, Amy S. Harrison, Allyson P Koecher, Jackson D Reeves, Lindsay B Romak
Affiliation: Christiana Care
Abstract Preview: Purpose: Surface guided radiation therapy (SGRT) is increasingly utilized in radiation oncology, allowing for transition away from permanent skin marks to SGRT-based daily treatment setup. Following i...
Authors: Gregory A Azzam, Danielle Cerbon, Laura Huang, Panayiotis Mavroidis, Diana Molinares, Stuart E Samuels, Sotirios Stathakis
Affiliation: Mary Bird Perkins Cancer Center, University of Miami Sylvester Comprehensive Cancer Center, Mount Vernan Rehabilitation Medicine Associates, Department of Radiation Oncology, University of Miami, University of North Carolina
Abstract Preview: Purpose: This study examines the correlation of different dose volume metrics of the skin, sternocleidomastoid (SCM) muscle and subcutaneous tissue (subcut) structures with the skin systemic sclerosis...
Authors: Jennifer L. Dolan, Chengyin Li, Parag Parikh, Doris N. Rusu, Kundan S Thind
Affiliation: Henry Ford Health, Cedars-Sinai Medical Center
Abstract Preview: Purpose: The time and resource demands of online Adaptive Radiation Therapy (ART) can limit its widespread clinical adoption and potentially impact patient throughput. To address this, we developed a ...
Authors: Rashmi Benda, Qinghao Chen, Shifeng Chen, Giovanni Lasio, Peter Olivieri, Huijun Xu, Junliang Xu, Byong Yong Yi, Baoshe Zhang, Jinghao Zhou
Affiliation: University of Maryland Baltimore Washington Medical Group, Department of Radiation Oncology, University of Maryland School of Medicine, Capital Region Medical Center, University of Maryland Shore Regional Cancer Center
Abstract Preview: Purpose:
We investigated if the patients receiving lung stereotactic body radiation therapy (SBRT) have adequate planning target volume (PTV) margins by evaluating the intrafraction motion using a ...
Authors: Jacob S. Buatti, Mu-Han Lin, Dominic Moon, David D.M. Parsons, David Sher, Justin D. Visak, Hui Ju Wang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX
Abstract Preview: Purpose: Most current adaptive treatment planning systems (TPS) natively utilize static planning goals from the reference plan for online adaptive re-optimization. In complex head-and-neck cancer (HNC...
Authors: Cheng-Chieh Cheng, Jeffrey P Guenette, Yajun Li, Bruno Madore, Lei Qin
Affiliation: Brigham and Women's Hospital, National Sun Yat-sen University, Dana-Farber Cancer Institute
Abstract Preview: Purpose: Pilot tone (PT), a compact RF sensor, has been integrated into clinical practice for motion detection. Prior studies proposed mapping PT signals to head positions using a calibration step tha...
Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Huiqiao Xie, Hao Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: This study introduces a novel spatiotemporal Gaussian neural representation framework to reconstruct high-temporal dynamic CBCT images from 1-minute acquisition, preserving motion dynamics an...
Authors: Renee Farrell, Jinkoo Kim, Xin Qian, Ziyu Shu, Zhaozheng Yin, Tiezhi Zhang
Affiliation: Stony Brook Medicine, Washington University in St. Louis, Stony Brook University, Stony Brook University Hospital
Abstract Preview: Purpose: Ultra-short CT scan allows fast imaging speed, dose reduction, and compact system design. We developed a deep image prior (DIP) based reconstruction method named Hybrid Prior-Enhanced Deep Im...
Authors: Rex A. Cardan, Carlos E. Cardenas, John B Fiveash, Joel A. Pogue, Richard A. Popple, Farnaz Rahim Li, Rodney J. Sullivan, Natalie N. Viscariello, Christopher Willey
Affiliation: The University of Alabama at Birmingham, University of Alabama at Birmingham
Abstract Preview: Purpose: vBrain radiosurgery toxicity-rate is estimated via clinically-relevant isodose volume (IDV) thresholds according to HyTEC (e.g., V12Gy≤10cc). HyperArcTM (HA) automated planning allows accurat...
Authors: Andreea Dimofte, Maksym Sharma, Weibing Yang, Timothy C. Zhu
Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania
Abstract Preview: Purpose:
To assess the effectiveness and dosimetric impact of utilizing a knowledge-based planning model for GI site-specific plans.
Methods:
Six knowledge-based planning models were develope...
Authors: Muhammed AR Anjum, Andrew J. Fagan
Affiliation: Mayo Clinic
Abstract Preview: Purpose:
This study describes a novel post-processing method to boost image SNR for deuterium-MRI acquired using chemical shift imaging (CSI) at 7T. Deuterium MRI via exogenous administration of a ...
Authors: James Irrer, Charles K. Matrosic, Martha M. Matuszak, Charles S. Mayo, Kelly C. Paradis, Joann I. Prisciandaro, Benjamin S. Rosen, John Yao, Claire Zhang
Affiliation: University of Michigan, Department of Radiation Oncology, University of Michigan
Abstract Preview: Purpose: To introduce an in-house developed tool, BioDoseUI, designed to calculate and visualize 3D equieffective dose (EQD2Gy) for treatment planning systems (TPS) without such capabilities, to facil...
Authors: Justus Adamson, John Ginn, Yongbok Kim, Ke Lu, Trey Mullikin, Xiwen Shu, Chunhao Wang, Zhenyu Yang, Jingtong Zhao
Affiliation: Duke University, Duke Kunshan University
Abstract Preview: Purpose:
To develop a knowledge-based deep model for synthetic CT (sCT) generation from a single MR volume in frameless radiosurgery (SRS), eliminating the need for CT simulation prior to the SRS d...
Authors: Todd A Aguilera, Bassel Dawod, Sebastian Diegeler, Eslam Elghonaimy, Purva Gopal, Jiaqi Liu, Hao Peng, Arely Perez Rodriguez, Nina N. Sanford, Robert Timmerman, Megan B Wachsmann, Haozhao Zhang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center
Abstract Preview: Purpose: This study pioneers the integration of CODEX (co-detection by indexing)-based spatial profiling and advanced computational techniques to investigate the tumor immune microenvironment (TIME) i...
Authors: Neal Andruska, Lianna D. DiMaso-Myers
Affiliation: Northwestern Medicine
Abstract Preview: Purpose: To provide details on how our clinic assesses respiratory motion during treatment of a pancreatic adenocarcinoma during dose escalated radiation therapy on a linear accelerator with the aid o...
Authors: Shusen Jing, Qihui Lyu, Dan Ruan, Ke Sheng, Qifan Xu
Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose: Metallic implants can significantly distort sinograms, leading to severe artifacts in computed tomography (CT) reconstructions. Reconstructing CT images containing metal is fundamentally an i...
Authors: Gregory A Azzam, Danielle Cerbon, Laura Huang, Panayiotis Mavroidis, Diana Molinares, Stuart E Samuels, Sotirios Stathakis
Affiliation: Mary Bird Perkins Cancer Center, University of Miami Sylvester Comprehensive Cancer Center, Mount Vernan Rehabilitation Medicine Associates, Department of Radiation Oncology, University of Miami, University of North Carolina
Abstract Preview: Purpose: This study aims at performing a normal tissue complication probability (NTCP) modeling by fitting the doses to the skin, sternocleidomastoid (SCM) muscle and subcutaneous tissue (subcut) stru...
Authors: Curtiland Deville, Rachel B. Ger, Heng Li, Todd R. McNutt
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University
Abstract Preview: Purpose: Proton therapy patients receive quality assurance CT scans (QACTs) during treatment to verify dosimetric accuracy and determine adaptive therapy needs as proton treatments are highly sensitiv...
Authors: Katja M. Langen, Mark McDonald, Bill Stokes, Yinan Wang, Suk Whan (Paul) Yoon
Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: Effective dose management in high-risk re-irradiation (ReRT) patients entails early, detailed special physics consultation (SPC) to mitigate risks from cumulative radiation dose. SPCs have tr...
Authors: Muhammad Ramish Ashraf, Clinton Gibson, Gregory Szalkowski, Lei Wang, Siqi Wang, Lei Xing
Affiliation: Department of Radiation Oncology, Stanford University, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University
Abstract Preview: Purpose: To develop a neural network-based super-resolution framework for enhancing the resolution of sparse dosimetry measurements in patient-specific radiotherapy QA. Sparse detector arrays, such as...
Authors: Hua-Chieh Shao, Guoping Xu, You Zhang, Tingliang Zhuang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose:
Advancements in onboard X-ray hardware allow high-quality CBCT imaging with a short scan time (~6s for Varian HyperSight), enabling CBCT-based dose calculation and treatment planning. Howe...
Authors: Rose Al Helo, Shengwen Deng, Sven L. Gallo, David W. Jordan
Affiliation: Department of Radiology, Radiation Safety, University Hospitals Cleveland Medical Center, University Hospitals Cleveland Medical Center, Department of Radiology, Radiation Safety, University Hospitals Cleveland Medical Center; School of Medicine, Case Western Reserve University; Department of Radiology, Louis Stokes Cleveland VA Medical Center
Abstract Preview: Purpose: From an educator perspective, preparing test questions for trainees is time-consuming and requires a lot of quality verification steps (review of stems, distractors, referencing) that can pot...
Authors: Asma Amjad, Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong
Affiliation: Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Accurate and precise linac-based SRS commissioning can be very challenging. Thus, it is important to increase the confidence in the measurement at each step prior to end-to-end testing. The p...
Authors: Minsong Cao, Amar Kishan, Dylan P. O'Connell, Jonathan Pham, Michael Steinberg, Luca F Valle, Michael Xiang
Affiliation: Department of Radiation Oncology, University of California, Los Angeles
Abstract Preview: Purpose: To evaluate bladder ultrasound as a surrogate for estimating on-table bladder volume in prostate cancer patients undergoing stereotactic body radiation therapy (SBRT). The study aimed to asse...