Search Submissions πŸ”Ž

Results for "yaw error": 29 found

A Conditional Point Cloud Diffusion Model for Deformable Liver Motion Tracking Via a Single Arbitrarily-Angled X-Ray Projection (PCD-Liver)

Authors: Yunxiang Li, Hua-Chieh Shao, Chenyang Shen, Jing Wang, Jiacheng Xie, Shunyu Yan, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Accurate liver deformable motion tracking is essential in image-guided radiotherapy to enable precise tumor targeting during treatment. We developed a conditional point cloud diffusion model ...

A Dynamic Reconstruction and Motion Estimation Framework for Cardiorespiratory Motion-Resolved Real-Time Volumetric MR Imaging (DREME-MR)

Authors: Jie Deng, Xiaoxue Qian, Hua-Chieh Shao, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Based on a 3D pre-treatment MRI scan, we developed DREME-MR to jointly reconstruct the reference patient anatomy and a data-driven, patient-specific cardiorespiratory motion model. Via a moti...

A Novel Group-Wise Non-Rigid Iterative Closest Point Shape Registration Algorithm with Temporal Smoothness Regularizations for Computing the Respiratory Motion of the Heart in Respiratory 4DCTs and Avoiding Random Cardiac Motion Artifacts

Authors: Hongyu An, Phillip Cuculich, H Michael Gach, Yao Hao, Trevor McKeown, Clifford Robinson, Yuhao Wang, Deshan Yang

Affiliation: Washington University School of Medicine in St. Louis, Washington University School of Medicine, Duke University, Department of Radiation Oncology, Duke University, Washington University in St. Louis, Department of Radiation Oncology, Washington University School of Medicine in St. Louis

Abstract Preview: Purpose: Cardiorespiratory motion management is crucial in stereotactic arrhythmia radiotherapy to define target margins and minimize cardiac toxicity. While respiratory 4DCT (r4DCT) images can infer ...

Abdomen CT Multi-Organ Segmentation Using Multi-Granularity Feature Extraction

Authors: Zilei Fu, Yi Guo, Wanli Huo, Hongdong Liu, Laishui Lyu, Zhao Peng, Yaping Qi, Senting Wang

Affiliation: Department of Radiotherapy, cancer center, The First Affiliated Hospital of Fujian Medical University, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University, Division of lonizing Radiation Metrology, National Institute of Metrology, State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, China Jiliang University, Department of Oncology, Xiangya Hospital, Central South University

Abstract Preview: Purpose: Medical image boundaries are commonly characterized by smooth gray-level transitions, resulting in pixel-level segmentation errors near these blurred boundaries. To address this, we developed...

An Automated Solution to Staged Treatments for Arteriovenous Malformations in Gammaknife

Authors: Strahinja Stojadinovic, Robert Timmerman, Yulong Yan

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose: Radiosurgery for large (>10cc) arteriovenous malformations (AVMs) poses significant challenges due to increased risks of complications and lower obliteration rates. To mitigate toxicity, larg...

Analysis of Structure Errors in Region of Interest Contouring for Radiotherapy Planning: A Study Using the RT-Contour QA Platform

Authors: Sijuan Huang, Zi LIU, Jing MA, Xin Yang

Affiliation: Sun Yat-sen University Cancer Center; State Key Laboratory of Oncology in South China; Collaborative Innovation Center for Cancer Medicine; Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangzhou, Guangdong, 510060, China

Abstract Preview: Purpose: To reduce the pressure of manual review of abnormal situations in manually/automatically delineated regions of interest (ROI), improve its accuracy and basis.
Methods: 220 radiotherapy pat...

BEST IN PHYSICS MULTI-DISCIPLINARY: Motion-Resolved Dynamic CBCT Reconstruction Using Prior-Model-Free Spatiotemporal Gaussian Representation (PMF-STGR)

Authors: Hua-Chieh Shao, Chenyang Shen, Jiacheng Xie, Shunyu Yan, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Motion-resolved CBCT imaging, which reconstructs a dynamic sequence of CBCTs reflecting intra-scan motion (one CBCT per x-ray projection), is highly desired for regular/irregular motion chara...

Characterization of a Novel Large-Sized Epid System from the Newly Released Ring Shape Radiation Therapy Halos Tx

Authors: Sen Bai, Guyu Dai, Dong Gao, Lecheng Jia, Guangjun Li, Yanfang Liu, Ying Song, Qing Xiao, Wei Zhang

Affiliation: United Imaging Healthcare, West China Hospital of Sichuan University, Shenzhen United Imaging Research Institute of Innovative Medical Equipment

Abstract Preview: Purpose:
Electronic portal imaging device (EPID) is currently the most widely used in-vivo dosimetry (IVD) device. However, the effective detector area shortage hinders further applications. This s...

Comparison of Clinical Virtual Unenhanced and True Unenhanced Images on a Prototype Deep Silicon Photon-Counting Detector CT

Authors: Meghan Lubner, Krista McClure, Aria M. Salyapongse, Timothy P. Szczykutowicz, Giuseppe Toia, Ming Yan, Zhye Yin, Meghan Yue

Affiliation: GE HealthCare, Departments of Radiology and Medical Physics, University Wisconsin-Madison, GE Healthcare, University of Wisconsin-Madison, UW-Madison, University of Wisconsin Madison, Department of Radiology

Abstract Preview: Purpose: To evaluate virtual unenhanced (VUE) and true unenhanced (TUE) human subject images on a prototype deep silicon photon-counting detector (PCD) CT with prototype algorithms.
Methods: 5 subj...

Comparison of Frame-Based and Frameless Gamma Knife Coordinate Spaces for Treatment of Trigeminal Neuralgia

Authors: Tatiana Bejarano, Omer Gal, Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Yongsook C. Lee, Michael W. McDermott, Minesh P. Mehta, Robert H. Press, Carlos M. Rivera, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose:
Gamma Knife (GK) cone beam computed tomography-based stereotactic reference (CBCTRef) combined with pre-planning MRI, provides a flexible alternative to the historical frame-based localiza...

Cross-Slice Attention for Unsupervised 3D Pelvic CBCT to CT Translation

Authors: Xu Chen, Jun Lian, Yunkui Pang, Pew-Thian Yap

Affiliation: University of North Carolina at Chapel Hill, Huaqiao University

Abstract Preview: Purpose: Unsupervised CBCT-to-CT translation in the pelvic region is essential for accurate radiotherapy delivery and adaptive image-guided interventions. However, current models for cross-modality tr...

Cycle-Consistent Multi-Task Automated Segmentation and Synthetic CT Generation Model for Adaptive Proton Therapy

Authors: Derek Tang, Susu Yan

Affiliation: Massachusetts General Hospital

Abstract Preview: Purpose: To evaluate the performance of a multi-task automated-segmentation and synthetic CT generation model (sCT) and investigate its application in an adaptive proton therapy workflow.
Methods: ...

Development of a Fast Quality Assurance Software Tool for Helical Online Adaptive Radiation Therapy

Authors: Guang-Pei Chen, Mi Huang, Haidy G. Nasief, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Recently, kV imaging has been integrated into the Accuray Radixact platform, facilitating online adaptive and scan-plan-treat workflows with helical delivery in the near future. In order to s...

Dosimetric Effect of Patient Positioning Errors in Dual-Isocenter VMAT for Bilateral Breast Cancer Treatment: A Quantitative Assessment

Authors: Awens Alphonse, Nebi Demez, Noufal Manthala Padannayil, Haley Park, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Nishan Shrestha, Somol Sunny

Affiliation: Florida Atlantic University, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: This study evaluates the dosimetric effects of patient positioning errors, including setup inaccuracies and yaw deviations, on dual-isocenter volumetric modulated arc therapy (VMAT) plans for...

Dosimetric Impact of Target Coverage with Inter-Fraction Patient Yaw Setup Error in IMRT/VMAT Prostate Cancer Radiotherapy

Authors: Min Su

Affiliation: Mount Sinai School of Medicine

Abstract Preview: Purpose: To evaluate dosimetric impact of patient setup yaw error to target coverage for pelvis/prostate radiation external beam IMRT-VMAT treatment.
Methods: 9 Pelvis/prostate IMRT-VMAT treatment ...

Dosimetric Impact on Patient Roll/Yaw Change for Whole Breast 3D Radiotherapy

Authors: Min Su

Affiliation: Mount Sinai School of Medicine

Abstract Preview: Purpose: To evaluate dosimetric impact of target coverage and organ at risk (OARs) sparing for whole breast patient setup roll/yaw change in 3D-conformal radiotherapy.
Methods: 8 whole breast cases...

Dual-Domain Neural Network Cone-Beam CT Correction for Online Adaptive Proton Therapy

Authors: Daniel H. Bushe, Arthur Lalonde, Hoyeon Lee, Harald Paganetti, Brian Winey

Affiliation: Universite de Montreal, Massachusetts General Hospital, Massachusetts General Hospital and Harvard Medical School, University of Hong Kong

Abstract Preview: Purpose: Improving the precision and fidelity of daily volumetric imaging is essential for enabling adaptive proton therapy (APT). While cone-beam CT (CBCT) provides daily volumetric imaging, their ut...

Efficient Monte Carlo Proton Dose Calculation Using Denoising Diffusion Probabilistic Models

Authors: Chieh-Ya Chiu, Shen-Hao Li, Hsin-Hon Lin, Shu-Wei Wu

Affiliation: Department of Medical Imaging and Radiological Sciences, Chang Gung University, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital Linkou

Abstract Preview: Purpose: Monte Carlo simulation enables precise calculation of dose distribution in proton therapy through tracing the radiation particles with patient tissues. However, achieving clinical-level preci...

Evaluation of Daily Respiratory Pattern from a Single Free-Breathing Cone Beam CT Scan

Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Xiuxiu He, Tianfang Li, Xiang Li, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
This work aims to develop an innovative technique to evaluate patients’ daily respiratory pattern using three-dimensional (3D) deformation vector fields (DVF) derived from a free-breathing...

Investigate Deep-Learned MRI Reconstruction with Data Consistency Mechanism and Task-Informed Loss

Authors: Mark Anastasio, Hua Li, Zhuchen Shao

Affiliation: Washington University School of Medicine, University of Illinois Urbana-Champaign

Abstract Preview: Purpose: Ill-conditioned reconstruction problems in medical imaging, such as those arising from undersampled k-space data in MRI, can result in degraded image quality and clinical task-orientated perf...

Investigation into the Robustness of Spine Stereotactic Body Radiotherapy Plans to Patient Setup Errors

Authors: Yukio Fujita, Syoma Ide, Fumiki Ito, Kei Ito, Satoshi Kito, Keiko Murofushi, Yujiro Nakajima, Yuhi Suda, Kentaro Taguchi, Naoki Tohyama, Fumiya Tsurumaki, Riku Watanabe

Affiliation: Komazawa University Graduate School, Komazawa University, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital

Abstract Preview: Purpose: Spine stereotactic body radiotherapy (SBRT) demands high precision due to the target's proximity to the spinal cord and steep dose gradients, which complicate treatment planning. Consequently...

Is Your Resident Ready to Become a Brachytherapy Physicist? a Training Exercise and Evaluation Tool in HDR Brachytherapy Planning Errors

Authors: Amar K. Basavatia, Lee C. Goddard, Wolfgang A. TomΓ©, Christian Velten, Ping Yan, Ravindra Yaparpalvi, Maria Stefania diMayorca

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: High dose rate (HDR) brachytherapy planning is a high-risk procedure performed under significant time pressure, with human failure being the leading cause of error. To elevate training for me...

Mask Guided Diffusion Model for Metal Artifacts Reduction

Authors: Shusen Jing, Qihui Lyu, Dan Ruan, Ke Sheng, Qifan Xu

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose: Metallic implants can significantly distort sinograms, leading to severe artifacts in computed tomography (CT) reconstructions. Reconstructing CT images containing metal is fundamentally an i...

Minimizing Positioning Errors in Intracranial SRS: The Role of Verification Imaging after 6-Dof Corrections

Authors: Anthony J. Doemer, Yimei Huang, Benjamin Movsas, Ellen Park, Mira Shah, Salim Siddiqui, Karen C. Snyder, Kundan S Thind, Bo Zhao

Affiliation: Henry Ford Health

Abstract Preview: Purpose: The 6 degrees-of-freedom (6-DoF) robotic couch is considered essential for linac-based stereotactic radiosurgery (SRS), particularly for irregularly shaped targets adjacent to critical organs...

Optimization of Impulsed Acquisition Protocols on 1.5T MRI Using Simulation-Based Bayesian Experimental Design for Cell Size Imaging

Authors: Yan Dai, Jie Deng, Xun Jia, Wen Li, Junzhong Xu

Affiliation: Johns Hopkins University, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiology, Vanderbilt University Medical Center, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Cell size is a vital parameter in evaluating the tumor microenvironment, including cell apoptosis and radiotherapy(RT)-induced immune cell infiltration. The IMPULSED(Imaging Microstructural P...

Real-Time 3D Dose Verification for MR-Guided Online Adaptive Radiotherapy (ART) Via Geometry-Encoded Deep Learning Framework

Authors: Steve B. Jiang, Dan Nguyen, Chenyang Shen, Fan-Chi F. Su, Jiacheng Xie, Shunyu Yan, Daniel Yang, Ying Zhang, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Fast dose verification is essential for the safety and efficiency of MR-guided adaptive radiotherapy (ART) as patients anxiously waiting on the treatment couch. Conventional tools often requi...

Real-Time Automatic Treatment Planning System (RT-AutoTPS) for Volumetric Modulated Arc Radiotherapy (VMAT)

Authors: Steve B. Jiang, Austen Matthew Maniscalco, Dan Nguyen, Chenyang Shen, Jiacheng Xie, Shunyu Yan, Ying Zhang, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Although treatment planning systems (TPSs) can handle dose calculation and plan optimization automatically, planning for radiotherapy still requires extensive efforts and expertise from a mul...

Robustness Enhancement for VMAT-TBI Planning and Treatment Delivery

Authors: Courtney R. Buckey, Quan Chen, Suzanne J. Chungbin, Edward L. Clouser, Yi Rong, Jun Tan, Jennifer Yan, Xiang Sheng Yan

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose:
To identify planning techniques that consistently result in robust VMAT-TBI plans that allow for larger patient setup errors.
Methods:
Conventional planning method often results in p...

Uncertainty Analysis of Hyperarc VMAT Plans for Stereotactic Radiosurgery Patients with Multiple Brain Metastases

Authors: Shifeng Chen, Yannick P. Poirier, Huijun Xu, Byong Yong Yi, Baoshe Zhang, Hong Zhang, Jinghao Zhou

Affiliation: University of Maryland School of Medicine, University of Maryland Shore Regional Cancer Center, Vanderbilt University Medical Center, Department of Radiation Oncology, University of Maryland School of Medicine, Capital Region Medical Center

Abstract Preview: Purpose: To thoroughly assess the resilience of HyperArc VMAT plans for multiple brain metastases (MBT) in relation to (i) high-definition MLC leaf positional inaccuracies and (ii) patient rotational ...