Authors: Chin-Cheng Chen, Chia-Ho Hua, Christopher J. Kutyreff, Thomas E. Merchant
Affiliation: St. Jude Children's Research Hospital
Abstract Preview: Purpose: A dosimetric study was conducted to determine the optimal field parameters for a commercially available small-field applicator (SFA) used in spot-scanning proton stereotactic radiosurgery, pa...
Authors: Laura Bennett, Wesley S. Culberson, Albert Du, Kevin J. Erhart, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake
Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care, .decimal
Abstract Preview: Purpose: To develop and experimentally validate a novel Monte Carlo (MC) framework designed to enable calculation-based quality assurance (QA) for collimated intensity modulated proton therapy treatme...
Authors: Louis Archambault, Luc Beaulieu, Alexis Horik, Sajjad Ahmad Khan
Affiliation: Département de Physique, de Génie Physique et D'optique, et Centre de Recherche sur le Cancer, Université Laval, Département de physique, de génie physique et d'optique, Université Laval
Abstract Preview: Purpose: This study presents a novel 2D scintillation dosimeter leveraging long scintillating fibers for quality assurance (QA) in radiotherapy. The primary goal is to optimize critical parameters suc...
Authors: Jaryd Ricardo Christie, Anthony J. Doemer, William T. Hrinivich, Junghoon Lee, Calin Reamy, Kundan S Thind
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Henry Ford Health
Abstract Preview: Purpose: To develop and validate an open-source Python package for fast, widely compatible, and user-friendly photon dose calculation algorithm through comparisons with clinical treatment planning sys...
Authors: Shae Gans, Carri K. Glide-Hurst, Mark Pankuch, Chase Ruff, Niek Schreuder, Nicholas R. Summerfield, Yuhao Yan
Affiliation: Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Northwestern Medicine Proton Center, Northwestern Medicine Chicago Proton Center, Leo Cancer Care
Abstract Preview: Purpose: Novel upright patient positioners coupled with diagnostic-quality vertical CT at treatment isocenter introduce a significant opportunity for improved image-guided particle therapy. Treating p...
Authors: Katja M. Langen, William Andrew LePain, Robert Muiruri, Vivi Nguyen, Mosa Pasha, Roelf L. Slopsema, Alexander Stanforth, Yinan Wang, Mingyao Zhu
Affiliation: Emory Healthcare, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) treatment planning for craniospinal irradiation (CSI) is complex and requires extensive effort from the planner. This study aims to enhance planning ...
Authors: Zahra Ahmadi Ganjeh, Stefan Both, Peter Dendooven, Jeffrey Free, Brian Zapien Campos
Affiliation: Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Particle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen
Abstract Preview: Purpose: Positron emission tomography (PET) has been investigated for range monitoring in intensity-modulated proton therapy (IMPT), but real-time feedback been limited due to the focus on long-lived ...
Authors: Julien Bancheri, Chau Giang Bui, Christopher M Lund, Morgan J Maher, Jamiel Nasser, Amy Parent, Monica Serban, Jan P. Seuntjens, Jason Z Yuan
Affiliation: University of Toronto, Medical Physics Unit, McGill University, Princess Margaret Cancer Centre, Princess Margaret Cancer Centre & University of Toronto
Abstract Preview: Purpose: Proton therapy (PT) has demonstrated greater precision and superior healthy tissue sparing compared to photon radiotherapy for various sites; however, PT systems are expensive, which limits g...
Authors: Sam Beddar, Jason Michael Holmes, Daniel G. Robertson, James J. Sohn, Ethan D. Stolen
Affiliation: Department of Radiation Oncology, Mayo Clinic, MD Anderson Cancer Center, Department of Radiation & Cellular Oncology, University of Chicago, Department of Radiation and Cellular Oncology, University of Chicago
Abstract Preview: Purpose: Camera-based scintillation dosimetry incorporating large volumes have shown promise for fast and comprehensive evaluation of external beam treatment fields. While some efforts have been made ...
Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing
Affiliation: CDT-West - Centrum für Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies
Abstract Preview: Purpose: To characterize the performance of novel shielded and unshielded silicon diode detectors in relative photon and electron beam dosimetry.
Methods: The novel shielded and unshielded sili...
Authors: Jeremy Eric Hallett, Aubrey Parks, Brian W Pogue
Affiliation: University of Wisconsin - Madison, University of Wisconsin-Madison
Abstract Preview: Purpose: Cherenkov imaging visualizes radiotherapy beams, assuming emission is proportional to deposited dose. However, attempts for Cherenkov as a quantitative dose estimation have been unsuccessful ...
Authors: Mark E Artz, Jiyeon Park, Lori Rice, Mohammad Saki, Sanjeev Shukla, Michael Vieceli
Affiliation: University of Florida Health Proton Therapy Institute, Department of Radiation Oncology, University of Florida College of Medicine, UF Health Proton Therapy Institute, Department of Urology, University of Florida College of Medicine
Abstract Preview: Purpose: To investigate how varying levels of DNA repair mutations affect the LET sensitivity of prostate cancer cells.
Methods: The prostate cancer cell lines Du145 (low DNA repair mutations), PC3...
Authors: Xiaoda Cong, Rohan Deraniyagala, Xuanfeng Ding, Xiaoqiang Li, Jian Liang, Peilin Liu, Craig Stevens, Xiangkun Xu, Weili Zheng
Affiliation: Corewell Health William Beaumont University Hospital, Corewellhealth William Beaumont University Hospital, William Beaumont University Hospital, Corewellhealth William Beaumont Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital
Abstract Preview: Purpose:
Commission a step-and-shoot arc therapy(SPArc-step&shoot) for treating head-neck cancer patients as a desired interim milestone toward full dynamic treatment.
Methods:
An in-house de...
Authors: Maria Jose Almada, Carlos Bohorquez, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger
Affiliation: LAP, Instituto Zunino - Fundacion Marie Curie
Abstract Preview: Purpose:
PSQA is crucial in maintaining patient safety, typically depending on dosimetric measurements. However, advancements in computational technology have highlighted the growing significance o...
Authors: Shupeng Chen, Xiaoda Cong, Raymond Dalfsen, Rohan Deraniyagala, Xuanfeng Ding, James E. Dolan, Xiaoqiang Li, Jian Liang, Peilin Liu, An Qin, Martin Soukup, Craig Stevens, Xiangkun Xu, Weili Zheng
Affiliation: Corewell Health William Beaumont University Hospital, Corewellhealth William Beaumont University Hospital, William Beaumont University Hospital, Elekta, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Corewellhealth William Beaumont Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital
Abstract Preview: Purpose: To facilitate clinical use of the proton feature of Monaco treatment planning system(TPS), we commissioned and validated it on a compact proton therapy system.
Methods: Pencil Beam Scannin...
Authors: Tianyuan Dai, Xiaoying Fan, Shuting Wang, Yong Yin
Affiliation: Department of Graduate, Shandong First Medical University, Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences
Abstract Preview: Purpose: The purpose of this study was to investigate the interplay effect during intra-fractional motion and the effect of the robust optimization parameters for inter-fractional motion in the intens...
Authors: Julien Forthomme, Carolina Llina Fuentes, Valentin Hamaide, Lucian Hotoiu, Rudi Labarbe, Rasmus Nilsson, Arnaud Pin, Francois Vander Stappen, Erik Traneus
Affiliation: RaySearch Laboratories AB, Ion Beam Applications SA
Abstract Preview: Purpose: Conformal FLASH achieves ultra-high-dose-rate (UHDR) proton therapy (>40 Gy/sec) by scanning a mono-energetic pencil beam through accessories (range shifter, Conformal Energy Modulator, apert...
Authors: Fumiaki Komatsu, Shunsuke Moriya, Ryosuke Nakamura, Takeji Sakae, Toshiyuki Terunuma, Tetsuya Tomita
Affiliation: Graduate School of Comprehensive Human Sciences, University of Tsukuba, Institute of Medicine, University of Tsukuba, Proton Medical Research Center, University of Tsukuba, Department of Radiology, University of Tsukuba Hospital
Abstract Preview: Purpose: To develop a deep learning (DL) model capable of accurately tracking lung tumors independent of beam angle variations.
Methods: A thoracic dynamic phantom simulating lung motion in the sup...
Authors: Petr Bruza, Megan Clark, David J. Gladstone, Joseph Harms, Anthony E. Mascia, Brian W Pogue, Roman Vasyltsiv, Zhiyan Xiao, Rongxiao Zhang, Yongbin Zhang
Affiliation: Cincinnati Children's Proton Therapy Center, University of Missouri, Dartmouth College, Thayer School of Engineering, Dartmouth College, Washington University in St. Louis, University of Wisconsin - Madison
Abstract Preview: Purpose: With developing FLASH trials requiring diligent delivery monitoring, current proton therapy in-vivo dosimetry (IVD) cannot provide comprehensive verification, including dose and dose-rate vol...
Authors: Indra J. Das, Ahtesham Ullah Khan, Andrew J. White
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine
Abstract Preview: Purpose: Small field dosimetry presents challenges due to lateral disequilibrium and the selection of suitable detectors. Volume averaging and density corrections hamper accurate profile measurements....
Authors: Wesley S. Culberson, Ryan Gardner, Patrick M Hill, Mark Pankuch, Karsten K. Wake
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Wisconsin, Northwestern Medicine Proton Center
Abstract Preview: Purpose: To assess the dosimetric capabilities of Sun Nuclear (Melbourne, FL) EDGE Diode Detectors™ for measurements in the plateau region of pencil beam scanning (PBS) fields. Many clinical dosimeter...
Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West
Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma
Abstract Preview: Purpose: To evaluate quantitatively the dosimetric uncertainties associated with dose calculation and measurement of small photon fields used in stereotactic photon therapy.
Methods: The output fac...
Authors: J Isabelle Choi, Meng Wei Ho, Isabel Lin, Hang Qi, Qi Zeng, Ajay Zheng
Affiliation: New York Proton Center, Scarsdale High School
Abstract Preview: Purpose: Proton therapy is a promising treatment modality for breast cancer due to its unique dosimetric advantage. Accurate dose calculation is critical to ensure effective treatment outcomes. The fo...
Authors: Winter Green, Yao Hao, Nels C. Knutson, Matthew C. Schmidt, Xiandong Zhao
Affiliation: Washington University School of Medicine in St. Louis, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine, WashU Medicine
Abstract Preview: Purpose: Beam profile flatness is crucial for both photon and proton radiotherapy systems. This work investigated the dosimetry impact of beam flatness on a clinical synchrocyclotron proton system.
Authors: Sean P. Boyer, Shae Gans, Mingcheng Gao, Draik B. Hecksel, Mark Pankuch
Affiliation: Northwestern Medicine Proton Center, Northwestern Medicine Chicago Proton Center
Abstract Preview: Purpose: Protons deposit a large portion of their energy at the end of their range in a region known as the Bragg peak, which may increase the relative biological effective (RBE) dose in this region. ...
Authors: Chin-Cheng Chen, Chingyun Cheng, Longfei Diao, Benjamin Durkee, Minglei Kang, Haibo Lin, LeLe Liu, Yangguang Ma, Xuanqin Mou, YunTong Pei, Charles B. Simone, YuFei Wang, Xueqing Yan, Xingyi Zhao, Wang Zhengda
Affiliation: Peking University, St. Jude Children's Research Hospital, New York Proton Center, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology, The First Affiliated Hospital of Zhengzhou University, School of Software Engineering, Xi’an Jiaotong University, School of information and communications engineering, Faculty of electronic and information engineering, Xi’an Jiaotong University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose: This study evaluates the effectiveness of apertures in improving lateral dose falloff in proton pencil beam scanning (PBS) single-energy Bragg peak (SEBP) FLASH radiotherapy (RT). The approac...
Authors: Yang Lei, Haibo Lin, Tian Liu, Charles B. Simone, Shouyi Wei, Ajay Zheng
Affiliation: Icahn School of Medicine at Mount Sinai, New York Proton Center
Abstract Preview: Purpose: Radiation-induced lung injury (RILI), encompassing pneumonitis and fibrosis, represents a critical dose-limiting factor in lung cancer radiation therapy. Variability in treatment outcomes is ...
Authors: Shinichiro Mori, Isabella Pfeiffer, Chester R. Ramsey, Alexander Usynin
Affiliation: Thompson Proton Center, National Institutes for Quantum Science and Technology, Thompson Cancer Survival Center
Abstract Preview: Purpose: Four-dimensional CT imaging (4DCT) has become a standard tool for managing respiratory motion in radiation therapy. However, many treatment delivery systems and most diagnostic CT scanners la...
Authors: Lawrence F. Bronk, Fada Guan, Xun Jia, Youfang Lai, Miao Qi
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: DNA double-strand breaks (DSBs) are widely regarded as critical indicators of cellular response to ionizing radiation. This study aims to establish a direct, unbiased and universal correlatio...
Authors: Wen C. Hsi, Kayla Schneider
Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences
Abstract Preview: Purpose:
Measurement-based patient-specific quality-assurance (PSQA) conducted with a 2D dosimeter to verify delivered dose of each field over 3 measurement-depths is time-consuming with limited se...
Authors: Yoshihiko Hoshino, Kenji Hotta, Taeko Matsuura, Ai Nakaoka, Hidenobu Tachibana
Affiliation: Hokkaido University, Department of Radiology, Gunma University Hospital, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East
Abstract Preview: Purpose: Gel dosimeters enable three-dimensional dose measurements, but no reports have evaluated the fundamental performance of VIPER-type gel dosimeters in proton beam measurements. Therefore, we ev...
Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing
Affiliation: CDT-West - Centrum für Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies
Abstract Preview: Purpose: To characterize field output correction factors of novel shielded and unshielded silicon diode detectors.
Methods: Novel shielded and unshielded Silicon Diode Detectors (SDD) were characte...
Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf
Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital
Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...
Authors: Cheng-En Hsieh, Shen-Hao Li, Hsin-Hon Lin, Shu-Wei Wu, An-Ci Yang
Affiliation: Department of Medical Imaging and Radiological Sciences, Chang Gung University, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital Linkou
Abstract Preview: Purpose:
The aim of this study is to develop a framework of generating patient-specific phantom tailored for head and neck proton therapy. From these phantoms, digital reference objects based on th...
Authors: B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Gawon Han, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip
Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute
Abstract Preview: Purpose: To develop and validate a high-fidelity Monte-Carlo (MC) model of a 0.5T bi-planar Linac-MR in TOPAS, focusing on accurate Multileaf Collimator (MLC) modelling and positioning for open apertu...
Authors: Wei Luo, Cameron Thayer-Freeman, Yifeng Zhao
Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky
Abstract Preview: Purpose: Real-time Kilovoltage (kV) imaging has emerged as a powerful clinical aid, providing high-precision localization of moving targets during treatment. However, the Megavoltage (MV) treatment be...
Authors: Caroline Esposito, Keith T Griffin, Jae Won Jung, Choonik Lee, Choonsik Lee, Matthew Mille, Harald Paganetti, Sergio Morato Rafet, Jan PO Schuemann, Jungwook Shin, Torunn I Yock
Affiliation: East Carolina University, University of Michigan, Massachusetts General Hospital, National Cancer Institute, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Massachusetts General Hospital and Harvard Medical School
Abstract Preview: Purpose: The National Cancer Institute’s Pediatric Proton and Photon Therapy Comparison Cohort aims to collect and analyze data from cancer centers across the United States and Canada to quantify diff...
Authors: Jacqueline M. Andreozzi, Savannah Decker, Diego Hernandez, Iman R. Washington
Affiliation: UC San Diego, Department of Radiation Oncology, Moffitt Cancer Center, University of South Florida, Moffitt Cancer Center
Abstract Preview: Purpose: Recent advances in external beam radiation therapy have begun to explore the utility of Cherenkov radiation imaging as a beam delivery visualization tool. When sheet bolus is used during trea...
Authors: Laura Buchanan, Samantha G. Hedrick, Stephen L. Mahan, Isabella Pfeiffer, Chester R. Ramsey
Affiliation: Thompson Proton Center
Abstract Preview: Purpose: Proton therapy plans can be highly sensitive to both anatomical changes and positional errors, making the acquisition of Quality Assurance CT (QACT) images a routine clinical practice during ...
Authors: Xiaoda Cong, Xuanfeng Ding, Gang Liu, Peilin Liu, Jiajian Shen
Affiliation: Department of Radiation Oncology, Mayo Clinic, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Corewellhealth William Beaumont University Hospital
Abstract Preview: Purpose: This study aims to develop the first SPArc optimization algorithm based on the Dynamic Programming (SPArc-DP), to improve the treatment delivery efficiency for synchrotron-accelerator-based P...
Authors: Sina Mossahebi, Pouya Sabouri, Kayla Schneider, James W Snider
Affiliation: University of Maryland School of Medicine, Proton International, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences
Abstract Preview: Purpose:
Conventional patient-specific QA (PSQA) for intensity-modulated proton therapy (IMPT) requires extensive measurements, straining resources in single-room proton centers. This study evaluat...
Authors: Wesley S. Culberson, Albert Du, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake
Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care
Abstract Preview: Purpose: To develop an accurate predictive temporal model for the movement of Dynamic Collimation System (DCS) trimmers during collimated proton pencil beam scanning (PBS) deliveries using log data. T...
Authors: Wesley S. Culberson, Albert Du, Ryan T. Flynn, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake
Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Iowa, Iowa Health Care
Abstract Preview: Purpose:
To perform end-to-end treatment planning and delivery verification of energy-specific collimated treatments optimized to achieve the maximum obtainable high-dose conformity using the dynam...
Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens
Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto
Abstract Preview: Purpose: Commissioning of a Gamma Knife® (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...
Authors: Michael M Folkerts, Miriam Krieger, Pierre Lansonneur, Gerard Paquet, Petar Penchev, Christoph Schuy, Yuri Simeonov, Uli Weber, Klemens Zink
Affiliation: GSI Helmholtzzentrum fuer Schwerionenforschung, Institute of Medical Physics and Radiation Protection (IMPS), University of Applied Sciences, Varian Medical Systems
Abstract Preview: Purpose:
Ultra-high dose-rate proton irradiation may spare the healthy tissue (FLASH-effect). The 3D-range-modulator (3D-RM) method reduces the treatment time compared to conventional IMPT and can ...
Authors: Ahmet S. Ayan, Estelle Batin, Austin M. Faught, Peter E. Klages, Eunsin Lee, Collin Nappi, Mina Okello, Meghana Ramani, Zachary X. Richards, Parisa Sadeghi
Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University
Abstract Preview: Purpose: Neutron doses are not modelled in proton treatment planning systems, so measurements were taken with two independent dosimeter types to quantify representative neutron fetal doses in pencil b...
Authors: Alyssa Gadsby, William J. Godwin, Daniel G. McDonald, Jean L. Peng, Alek K. Rapchak, Sean A Roles, Austin M. Skinner, Stephanie Tan
Affiliation: Medical University of South Carolina
Abstract Preview: Purpose: The Sun Nuclear MapCheck3 device is used for patient-specific QA. While it is typically employed in perpendicular field-by-field delivery using the Isocentric Mounting Fixture, fields not ful...
Authors: Larry A. DeWerd, Ahtesham Ullah Khan
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison
Abstract Preview: Purpose: Total body irradiation (TBI) technique uses high energy photon beams with extended source-to-surface distances (SSDs) to irradiate the entire patient to prepare them for bone marrow or stem c...
Authors: Salahuddin Ahmad, Imad M. Ali, Zaid Alkalani, Nesreen Alsbou
Affiliation: University of Oklahoma, University of Central Oklahoma, University of Oklahoma Health Sciences Center
Abstract Preview: Purpose: To design and evaluate a 3D-detector for proton CT-imaging and radiography, utilizing volumetric plastic scintillator detector exposed to high-energy therapeutic beams from proton therapy sys...
Authors: Stephen M Corner, Daiki Hara, Jiasen Ma, Robert W Mutter, Mark D. Pepin, Nicholas B. Remmes, Hok Seum Wan Chan Tseung
Affiliation: Mayo Clinic - Rochester
Abstract Preview: Purpose: Proton minibeam radiotherapy (pMBRT) is a form of spatially fractionated radiation therapy leveraging submillimeter beams to improve the therapeutic ratio. We report on collimator design, com...
Authors: Gueorgui Gueorguiev, Kavya Thaniyarasu
Affiliation: University of Bologna, National Centre of Radiobiology and Radiation Protection
Abstract Preview: Purpose: This study investigates the clinical viability of double scattering proton therapy treatment planning for thoracic malignancies using single or multiple treatment fields. The aim of this stud...
Authors: Yao Hao, Yuting Peng, Francisco Javier Reynoso, Tianyu Zhao, Xiandong Zhao
Affiliation: Varian, University of South Florida, Washington University School of Medicine, Washington University School of Medicine, Department of Radiation Oncology
Abstract Preview: Purpose: Ultra-high dose-rate (FLASH) dose rate (> 40 Gy/s) may result in a radio-protective effect in healthy tissue compared with conventional dose rate (CDR). This effect has been observed in vivo ...
Authors: Yankui Chang, Shijun Li, Xi Pei, Ripeng Wang, Xuanhe Wang, X. George Xu, Qing Zhang, Jingfang Zhao
Affiliation: University of Science and Technology of China, Shanghai proton and heavy ion center, School of Nuclear Science and Technology, University of Science and Technology of China, Anhui Wisdom Technology Co., Ltd.
Abstract Preview: Purpose:
This paper describes disruptive methods using both GPU-based MC simulation and deep-learning (DL)-based MC denoising algorithms, as well as clinical tests involving more than 560 patient p...
Authors: Yong Chen, Gilberto Gonzalez, Omprakash Gottam, Liangzhong Xiang
Affiliation: University of California, Irvine, Koneru Lakshmaiah Education Foundation, University of Texas at San Antonio., University of Oklahoma Health Science Center
Abstract Preview: Purpose: Clinics currently lack techniques for real-time, in vivo monitoring of radiation therapy (RT), which is desirable for precise treatment. Radiation-induced acoustic computed tomography (RACT) ...
Authors: Lori Buchholtz, Alison Garda, Chris L. Hallemeier, Kathryn L. Kolsky, Han Liu, Joseph John Lucido, Marisa Schinter, Andrew J. Veres, Sara Walerak
Affiliation: Mayo Clinic
Abstract Preview: Purpose: The C_START initiative aims to streamline and simplify the Direct-to-Unit (DtU) clinical setup and treatment planning process for photon radiation therapy, particularly for emergent cases suc...
Authors: Kevin Peter Risolo
Affiliation: University of Pennsylvania
Abstract Preview: Purpose: To quantify the improved efficiency of checking patient treatment plan MU by utilizing RadFormation’s ClearCalc script-based program.
Methods: A total of 58 patients planned for treatment ...
Authors: Yujie Chi, Yao Hao, Xun Jia, Youfang Lai, Yuting Peng, Francisco Javier Reynoso, Lingshu Yin, Tianyu Zhao, Xiandong Zhao
Affiliation: Johns Hopkins University, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Physics, University of Texas at Arlington, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, University of South Florida
Abstract Preview: Purpose: FLASH radiation therapy has shown remarkable tissue sparing effects compared to radiation therapy at conventional dose rates (CDR). Yet, its mechanism remains unclear. Radical production modu...
Authors: Ozgur Ates, Chin-Cheng Chen, Chia-Ho Hua, Matthew J. Krasin, Thomas E. Merchant
Affiliation: St. Jude Children's Research Hospital
Abstract Preview: Purpose: To validate the use of synthetic CTs generated from CBCT images for online monitoring, ensuring accurate and reliable daily plan quality assessments in adaptive proton therapy (APT).
Metho...