Authors: Dale W. Litzenberg, Ikechi S Ozoemelam, Rowan Paplanus, Michael Pillainayagam, Donald A. Roberts
Affiliation: University of Michigan, Oregon Health & Science University
Abstract Preview: Purpose: Clinical linear accelerators use dual foil scattering systems designed to achieve large uniform fields (up to 25Ă25cmÂČ), which can reduce beam fluence by up to 93% compared to the unmodified ...
Authors: Denis Bergeron, Ryan P Fitzgerald, Ravneet Kaur, Rao Khan
Affiliation: John Hopkins University, NIST Radiation Physics Division, Howard University, National Institute of Standards and Technology
Abstract Preview: Purpose: There is growing interest in short-lived alpha-emitting radionuclides for cancer therapy due to their ability to selectively target and destroy cancer cells while sparing healthy tissue. Howe...
Authors: Anna Becker, Tomislav Bokulic, Mauro Carrara, Krzysztof Chelminski, Larry A. DeWerd, Alexis Dimitriadis, Benjamin Kellogg, Malcolm R. McEwen, Zakithi L.M Msimang, Mark J. Rivard, Thorsten Sander, Thorsten Schneider, Jamema Swamidas, Egor Titovich, Paula Toroi, Carlos E. de Almeida, Jacco de Pooter, Liset de la Fuente Rosales, Deborah G. van der Merwe
Affiliation: Radiation and Nuclear Safety Authority, University of Zagreb, National Physical Laboratory, IAEA, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Rio de Janeiro State University, Dosimetry Laboratory, Dosimetry and Medical Radiation Physics Section, Division of Human Health, International Atomic Energy Agency, Physikalisch-Technische Bundesanstalt, National Metrology Institute, University of the Witwatersrand, Dosimetry and Medical Radiation Physics Section, Division of Human Health, International Atomic Energy Agency, National Research Council, Warren Alpert Medical School of Brown University
Abstract Preview: Purpose: The recently published IAEA-TRS-492 international code of practice (CoP) aims at improving traceability, accuracy, and consistency in Brachytherapy Dosimetry. To assess current approaches to ...
Authors: Zhitao Dai
Affiliation: Chinese Academy of Medical Sciences Cancer Hospital Shenzhen Hospital
Abstract Preview: Purpose: To investigate the accuracy of 3D printed individualized vaginal template assisted pre-planning in the interstitial implantation of cervical cancer, to examine the advantages when compared wi...
Authors: Amy Tien Yee Chang, Chi Wai Cheung, Tin Lok Chiu, Chen-Yu Huang, Chi Wa Kong, Pei-Xiong Li, Pak Hang Nam, Bin Yang, Siu Ki Yu
Affiliation: Comprehensive Oncology Centre, Hong Kong Sanatorium and Hospital, Medical Physics Department, Hong Kong Sanatorium and Hospital
Abstract Preview: Purpose: This study introduces BrachyPlanCheck, an independent Monte Carlo (MC)-based dose calculation tool for 192Ir brachytherapy retrospective study or algorithm commissioning.
Methods: BrachyPl...
Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing
Affiliation: CDT-West - Centrum fĂŒr Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies
Abstract Preview: Purpose: To characterize the performance of novel shielded and unshielded silicon diode detectors in relative photon and electron beam dosimetry.
Methods: The novel shielded and unshielded sili...
Authors: David J. Carlson, Yiu-Hsin Chang, Huixiao Chen, Zhe (Jay) Chen, Blake Gaderlund, Ray Yang
Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose: To address the root cause of dosimetric discrepancy for small central targets (<2cm) especially sensitive to geometric alignment of beamlets, by modeling higher-order oscillations of the coll...
Authors: Colin Adam Doyle, Celeste Winters
Affiliation: Department of Diagnostic Radiology, Oregon Health & Science University, School of Medicine, Oregon Health & Science University
Abstract Preview: Purpose: To audit our radioactive iodine (I-131) dosimetry protocol, review dosimetry methods used at other facilities, investigate the clinical impact of I-131 dosimetry at our facility, and test the...
Authors: Mauro Carrara, Olivera Ciraj Bjelac, John E. Damilakis, Andre L. Dekker, Serafina Di Gioia, Renato Padovani, Egor Titovich, Qingrong Jackie Wu
Affiliation: University of Crete, Duke University Medical Center, Maastro Clinic, Dosimetry and Medical Radiation Physics Section, Division of Human Health, International Atomic Energy Agency, International Centre for Theoretical Physics
Abstract Preview: Purpose: The purpose of this work is to present the International Atomic Energy Agency (IAEA) activity in providing medical physicists (MPs) with knowledge, skills, and competencies to support the saf...
Authors: Clifford Ghee Ann Chua, Calvin Wei Yang Koh, Kah Seng Lew, Zubin Master, Sung Yong Park, Hong Qi Tan, Andrew Wibawa
Affiliation: National Cancer Centre Singapore
Abstract Preview: Purpose: To investigate the impact of spot position deviation on reference dosimetry measurements using different delivery patterns and to determine the optimal delivery pattern for reference dosimetr...
Authors: Gregory T. Armstrong, James E. Bates, Kristy K. Brock, Laurence Edward Court, Matt Ehrhardt, Danielle Friedman, Aashish C. Gupta, Donald Hancock, Rebecca M. Howell, Cindy Im, Tera S Jones, Choonsik Lee, Wendy Leisenring, Taylor Meyers, Lindsay Morton, Chaya Moskowitz, Joe Neglia, Vikki Nolan, Caleb O'Connor, Kevin C. Oeffinger, Constance A. Owens, Arnold C. Paulino, Chelsea C. Pinnix, Sander Roberti, Cecile Ronckers, Susan A. Smith, Kumar Srivastava, Lucie Turcotte
Affiliation: Department of Medicine, Duke University School of Medicine, Department of Epidemiology and Cancer Control, St. Jude Childrenâs Research Hospital, The University of Texas MD Anderson Cancer Center, Department of Oncology, St. Jude Childrenâs Research Hospital, Department of Pediatrics, Memorial Sloan Kettering Cancer Center, Division of Pediatric Epidemiology and Clinical Research, University of Minnesota, Division of Childhood Cancer Epidemiology, University Medicine at Johannes Gutenberg University Mainz, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Pediatrics, University of Minnesota, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Department of Biostatistics, St. Jude Childrenâs Research Hospital, Clinical Research Division, Fred Hutchinson Cancer Center, Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Department of Epidemiology and Biostatistics, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University, The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences
Abstract Preview: Purpose: To (1) develop and validate a novel anatomically realistic pediatric/adolescent population-based breast model, (2) incorporate model into an age-scalable female reference phantom, and (3) dem...
Authors: Sang Hyun Cho, Amrit Kaphle, Sunil Krishnan, Neerajan Nepal
Affiliation: The University of Texas MD Anderson Cancer Center, The University of Texas Health Science Center
Abstract Preview: Purpose: To determine the basic dosimetry parameters and characteristics of a commercial cabinet x-ray unit for small animal irradiation as well as the specific dosimetry parameters for concurrent irr...
Authors: Kenneth W. Gregg, Beatriz Guevara, Lauren E Henke, Rojano Kashani, Kyle O'Carroll, Gisele Castro Pereira, Christian Erik Petersen, Alex T. Price, Meiying Xing, Reine abou Zeidane
Affiliation: university hospital, University Hospitals Seidman Cancer Center
Abstract Preview: Purpose:
Experimental data have shown the inconsistent monitor unit and target coverage in Ethos 1.1. This can lead to inaccurate dose delivery, compromising patient safety and treatment outcomes. ...
Authors: Seohyeon An, Yoonsun Chung, Seonghoon Jeong, Seongmoon Jung, Chae-Eon Kim, In Jung Kim, Sung Hun Kim, Se Byeong Lee, Sang-il Pak, Jong In Park
Affiliation: POHANG ACCELERATOR LABORATORY, Hanyang University, Korea Research Institute of Standards and Science (KRISS), Ilsan Paik Hospital, National Cancer Center, National Cancer Center Korea, Korea Research Institute of Standards and Science
Abstract Preview: Purpose: To evaluate the performance of three ion chambersâAdvanced Markus (AMC), PinPoint, and Roosâunder FLASH proton beam conditions and assess the response of the nozzle monitor chamber for their ...
Authors: Louis Archambault, Nicolas Drouin, Alexis Horik, Simon Thibault
Affiliation: Département de Physique, de Génie Physique et D'optique, et Centre de Recherche sur le Cancer, Université Laval, Département de Physique, de Génie Physique et D'optique, et Centre d'optique, photonique et laser, Université Laval
Abstract Preview: Purpose: To develop a novel type of real-time 3D dosimeter for the quality assurance of linear accelerators used in external beam radiotherapy.
Methods: An experimental setup was constructed using ...
Authors: Claire Keun Sun Park, Atchar Sudhyadhom, Veena Venkatachalam, Noah Warner
Affiliation: HarvardâMIT Program in Health Sciences and Technology, Massachusetts Institute of Technology, Brigham and Womenâs Hospital and Dana Farber Cancer Institute, Harvard Medical School,, Brigham and Womenâs Hospital and Dana Farber Cancer Institute, Harvard Medical School
Abstract Preview: Purpose: Modern radiotherapy achieves sub-millimeter spatial accuracy but fails to account for patient- and spatially-specific variations in biological response. Free radical generation (FRG), particu...
Authors: Anthony J. Doemer, Aharon Feldman, Stephen J. Gardner, Brett M. Miller, Benjamin Movsas, Farzan Siddiqui, Chadd Smith, Kundan S Thind, Kyle Verdecchia
Affiliation: Henry Ford Health
Abstract Preview: Purpose: To evaluate the efficacy of calculation-only approach for CIED risk-level assessment.
Methods: A total of 86 patients were included in this retrospective analysis. For each patient, in viv...
Authors: Wesley A. Belcher, Robert A. Corns, Jae Won Jung, Matthew S Peach, Swarup Sharma
Affiliation: The University of North Carolina at Chapel Hill, East Carolina University Brody School of Medicine
Abstract Preview: Purpose: GammaTiles are a novel intracranial brachytherapy approach designed to directly deliver radiation therapy to residual or recurrent brain tumors following resection. Despite their promising th...
Authors: Nesrin Dogan, Panagiota Galanakou, Robert Kaderka
Affiliation: University of Miami, Sylvester Comprehensive Cancer Center, University of Miami Sylvester Comprehensive Cancer Center
Abstract Preview: Purpose:
To develop knowledge-based treatment planning (KBP) for volumetric modulated arc therapy (VMAT) in chest wall treatments with regional nodal involvement. Given the challenges posed due to ...
Authors: NadÚge Anizan, Jean-Noël Badel, Thomas Baudier, David Broggio, Désirée Deandreis, Ludovic Ferrer, Didier Franck, Camilo Garcia, Jean Gasteuil, Anne-Laure Giraudet, Olivier Humbert, Laetitia Imbert, Malick Koulibaly, Stéphanie Lamart, Sébastien Leygnac, Alexandre Pignard, Caroline Rousseau, Guido Rovera, David Sarrut, Paul Schwartz, Nicolas Varmenot
Affiliation: Institut de CancĂ©rologie de lâOuest, Service de MĂ©decine NuclĂ©aire, Gustave Roussy, Service de Physique MĂ©dicale, Institut BergoniĂ©, Service de Physique MĂ©dicale, CHRU de Nancy Brabois, Service de MĂ©decine NuclĂ©aire, Centre de lutte contre le cancer LĂ©on BĂ©rard, UniversitĂ© de Lyon, Centre Antoine Lacassagne, Service de MĂ©decine NuclĂ©aire, UniversitĂ© Nice CĂŽte dâAzur, Centre Antoine Lacassagne, Service de MĂ©decine NuclĂ©aire, Gustave Roussy, Service de MĂ©decine NuclĂ©aire, Institut de CancĂ©rologie de lâOuest, Service de Physique MĂ©dicale, Service de MĂ©decine NuclĂ©aire, AutoritĂ© de SĂ»retĂ© NuclĂ©aire et de Radioprotection (ASNR), PSE-SANTE/SDOS/LEDI, AutoritĂ© de SĂ»retĂ© NuclĂ©aire et de Radioprotection (ASNR), PSE-SANTE/SDOS, CREATIS CNRS UMR 5220; INSERM U 1044; UniversitĂ© de Lyon; INSAâLyon, CREATIS CNRS UMR 5220; INSERM U 1044; UniversitĂ© de Lyon; INSAâLyon; Centre de lutte contre le cancer LĂ©on BĂ©rard, Institut BergoniĂ©, Service de MĂ©decine NuclĂ©aire
Abstract Preview: Purpose: The main objective of the Lu-PSMA-Dose study, sponsored by ASNR, is to estimate retrospectively the individual absorbed dose delivered to patients treated with 177Lu-PSMA for metastatic castr...
Authors: Qihui Lyu, Dan Ruan, Ke Sheng, Jingjie Yu
Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose: The robotic arm radiotherapy platform enables flexible delivery of non-coplanar and non-isocentric radiotherapy with variable Source-to-Isocenter Distances (SIDs). However, the high degrees o...
Authors: Charles D. Bloch, Stephen R. Bowen, Bing-Hao Chiang, Alex Egan, Eric C. Ford, Sharareh Koufigar, Dominic A. Maes, Juergen Meyer, Sharon Pai, Frank Rafie, Rajesh Regmi, Jatinder Saini, George A. Sandison, Marco Schwarz, Bishwambhar Sengupta, Tony P. Wong
Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Department of Physics, University of Washington
Abstract Preview: Purpose: This study aimed to optimize the strategy and timing of physics consults for proton prostate patients to improve the patient experience and resource utilization in our radiation oncology depa...
Authors: NadÚge Anizan, David Broggio, Désirée Deandreis, Didier Franck, Camilo Garcia, Stéphanie Lamart, Sébastien Leygnac, Alexandre Pignard
Affiliation: Gustave Roussy, Service de Physique Médicale, Institut Bergonié, Service de Physique Médicale, Gustave Roussy, Service de Médecine Nucléaire, Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSE-SANTE/SDOS/LEDI, Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSE-SANTE/SDOS
Abstract Preview: Purpose: This work aimed at developing an innovative workflow for 177Lu-PSMA personalized dosimetry to lesions and organs at risk (OAR) simultaneously, considering the cross-irradiation from bone meta...
Authors: Jeremy S. Bredfeldt, Daniel W. Cail, Maria A. Czerminska, Cindy I. Hancox, David Hu, Benjamin Karasko, Claire Keun Sun Park
Affiliation: Department of Radiation Oncology, Brigham and Women's Hospital, Harvard Medical School, Brigham and Women's Hospital, Brigham and Womenâs Hospital and Dana Farber Cancer Institute, Harvard Medical School
Abstract Preview: Purpose: To develop a robust clinical protocol for in vivo dosimetry in radiotherapy using the myOSLchip Optically Stimulated Luminescent Dosimeter (OSLD) system by performing characterization and eva...
Authors: Chih-Wei Chang, Kristin A Higgins, Xiaojun Jiang, Pretesh Patel, Justin R. Roper, Keyur Shah, Sibo Tian, Zhen Tian, Yinan Wang, Xiaofeng Yang, Jun Zhou
Affiliation: Department of Radiation Oncology, City of Hope Cancer Center Atlanta, Emory University, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: Ventricular tachycardia (VT) is a life-threatening arrhythmia commonly treated with catheter ablation; however, some cases remain refractory to conventional treatment. Stereotactic arrhythmia...
Authors: Guilherme Rosa Ferreira, Dan Giardina, John Karageorgiou, Chris Malone, Allan Thomas
Affiliation: Washington University School of Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine
Abstract Preview: Purpose: Radiation segmentectomy has become a primary strategy in 90Y radioembolization, with localized treated volumes that can include up to two liver segments. The goal is complete pathological nec...
Authors: David P. Adam, Allison Cartee, Eric C. Frey, Michael Ghaly, Bin He, Robert Francois Hobbs, Natalie Rose Kania, Ana Kiess, Ian Marsh, Bonnie N. C. President, Steven Rowe, George Sgouros, Phuoc Tran, Hao Wang
Affiliation: Johns Hopkins University, Radiopharmaceutical Imaging and Dosimetry, LLC (Rapid), 2The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins Medical Institute, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Oncology, Johns Hopkins University, School of Medicine, Department of Radiology, University of North Carolina, Chapel Hill
Abstract Preview: Purpose: Advanced treatment paradigms combining SPECT/CT imageable, alpha emitting, radiopharmaceutical therapy (RPT) and stereotactic body radiotherapy (SBRT) can provide the potential of dose escala...
Authors: Tommaso Frigerio, Joshua Genender, John M. Hoffman, Catherine (Caffi) Meyer
Affiliation: UCLA, David Geffen School of Medicine at UCLA
Abstract Preview: Purpose: Accurate bone marrow segmentation is required for bone marrow dosimetry to monitor for dangers in PSMA-Lu177 radioligand therapy. We introduce a hybrid (AI/semantic knowledge) segmentation pi...
Authors: Angela Gearhardt, Stephen F. Kry, Christopher Ryan Peeler, Julianne M. Pollard-Larkin
Affiliation: The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences; The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: A growing number of radiation therapy (RT) patients have cardiovascular implantable electronic devices (CIEDs). Patients with CIEDs must be carefully managed because the devices are susceptib...
Authors: Stephen Araujo, Jing-Tzyh Alan Chiang, Cynthia E. Davis, Eri Haneda, Andrew Karellas, Thomas C Larsen, William Ross, Hsin Wu Tseng, Srinivasan Vedantham, Pengwei Wu
Affiliation: Department of Biomedical Engineering, The University of Arizona, GE Aerospace Research, Department of Medical Imaging, The University of Arizona, GE HealthCare Technology & Innovation Center
Abstract Preview: Purpose: To determine the system parameters and technique factors for image acquisition needed so that the mean glandular dose (MGD) of approximately 4.5 mGy is not exceeded for a recently developed, ...
Authors: Lei Fu, Eric Gressen, Yingcui Jia, Shari Rudoler, Yevgeniy Vinogradskiy, Qianyi Xu
Affiliation: Thomas Jefferson University
Abstract Preview: Purpose: InTempo imaging in the Accuray CyberKnife System improves the ability to track/correct target motion during treatment. However, no studies have provided information on the impact of InTempo I...
Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed
Affiliation: Bay Pines VA Medical Center
Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...
Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Gunjan Kayal, Adam Leon Kesner, Harry Marquis, Juan Camilo Ocampo Ramos, Stefan Wehmeier
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson
Abstract Preview: Purpose: Accurate organ dose estimation in computed tomography (CT) has gained attention due to the increasing global utilization of CT imaging. MIRDct, a specialized CT dosimetry software, has recent...
Authors: Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, Tae Ho Kim, Sangmin Lee
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine
Abstract Preview: Purpose: The CyberKnife system, designed for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT), considers SRS MapCHECK an effective tool for patient-specific QA (PSQA). This wo...
Authors: Klaus Bacher, Louise D'hondt, Jeff Rutten, Gwenny Verfaillie
Affiliation: Ghent University
Abstract Preview: Purpose: Manual organ segmentation is a very time-consuming but necessary process in personalized dosimetry. Automatic segmentation tools may alleviate this task. In this study the impact of automatic...