Search Submissions 🔎

Results for "cas chambers": 105 found

6FFF Beam Output Trend Showing Target Degradation

Authors: Sean L. Berry, Hsiang-Chi Kuo, Seng Boh Gary Lim, Ingrid Valencia Lozano, Laszlo Voros

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
To quantify the impact of target degradation on 6FFF beam output by analyzing the output trends and adjustment frequencies at our clinic on a flattening filter-free (6FFF) and a flattened ...

A 2D Discrete Ionization Chamber Array for Proton Pencil Beam Scanning Flash Dosimetry

Authors: Fu-Xiong Chang, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Nancy Y Lee, Chih-Hsun Lin, Haibo Lin, Hang Qi, Mahbubur Rahman, Charles B. Simone, Pingfang Tsai, Shouyi Wei, Irini Yacoub, Yunjie Yang, Ajay Zheng, Jun Zhou

Affiliation: New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, Liverage Biomedical Inc., Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University, Institute of Physics, Academia Sinica

Abstract Preview: Purpose: FLASH therapy presents an opportunity to alter the radiotherapy paradigm and significantly enhancing normal organ protection while maintaining the effectiveness of tumor control. The temporal...

A 3D Printed Ion Chamber Insert Solution for Absolute Dosimetry with Varying Ionisation Chambers in Radiosurgery.

Authors: Shashanksharad Kale, Gopishankar Natanasabapathi, Daya Nand Kishore Sharma

Affiliation: All India Institute of Medical Sciences (AIIMS), Department of Radiation Oncology, All India Institute of Medical Sciences

Abstract Preview: Purpose:
The study demonstrates a novel 3D printing method to fabricate an ion chamber insert (ICI) for absolute dosimetry purpose in gamma knife radiosurgery (GKRS).
Methods:
Our institute u...

A GPU Accelerated Monte Carlo Dose Engine for Small Animal Proton Radiotherapy

Authors: Haonian Gong, Yue Gu, Meiqi Liu, Zihao Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang, Cheng Zheng

Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose:
Proton radiotherapy in preclinical small animals requires specific dose engine due to its low energy and small irradiation volume. This study is to develop a GPU-based Monte Carlo dose eng...

A Motion Analysis of Cardiac Substructures for Guiding Stereotactic Arrhythmia Radiotherapy Motion Management

Authors: Hongyu An, Phillip Cuculich, H Michael Gach, Yao Hao, Trevor McKeown, Clifford Robinson, Yuhao Wang, Deshan Yang

Affiliation: Washington University School of Medicine in St. Louis, Washington University School of Medicine, Duke University, Department of Radiation Oncology, Duke University, Washington University in St. Louis, Department of Radiation Oncology, Washington University School of Medicine in St. Louis

Abstract Preview: Purpose: This study investigated cardiac motion characteristics of ventricular tachycardia patients to support patient-specific motion management for stereotactic arrhythmia radiotherapy (STAR) treatm...

A Novel Approach to Preclinical Intensity-Modulated Radiotherapy Using an Open-Source Ring-Based Compensator Device and Inverse Treatment Planning System

Authors: Benjamin R. Awad, Bulent Aydogan, Howard J Halpern, Erik Pearson, Gage H. Redler, Jordan M. Slagowski, Rajit Tummala, Autumn E. Walter-Denzin, Jimmy Zydlo

Affiliation: University of Wisconsin-Madison Department of Human Oncology, University of Oxford, The University of Chicago, Moffitt Cancer Center, California State University, Fresno, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Small animal models are crucial in cancer research to develop, validate, and translate basic scientific hypotheses into clinical advancements. This study aims to make small animal intensity-m...

A Perturbative Approach to Determine the Charge Collection Efficiency in High Dose-per-Pulse Beams

Authors: Julien Bancheri, Jan P. Seuntjens

Affiliation: Medical Biophysics, University of Toronto, Princess Margaret Cancer Centre & University of Toronto

Abstract Preview: Purpose: To obtain an analytical expression for the charge collection efficiency of parallel-plate ionization chambers in high dose-per-pulse (DPP) beams that takes into account the square pulse time ...

A Risk Assessment Approach to Photon Reference Dosimetry Using TG-100 Methodology

Authors: Ila Farhang, Ryan D. Foster, Devin Heitz, Jordan B Lunsford, Ashkan Shafiee

Affiliation: Atrium Health Wake Forest Baptist, Atrium Health/LCI Cabarrus

Abstract Preview: Purpose: American Association of Physicists in Medicine (AAPM) Task Group (TG) -51 is a widely utilized protocol for the absolute calibration of linear accelerators. The purpose of this project was fo...

Absolute Measurement of HDR Ir-192 Air-Kerma Strength Using an Exradin A3 Known-Volume Ionization Chamber

Authors: Larry A. DeWerd, Sean Jollota, Karen Rex Pius Vincent

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Absolute measurements, often used to establish primary standards, offer lower measurement uncertainty. For 192Ir high-dose-rate (HDR) brachytherapy, the interim primary standard for air-kerma...

Advancing Cardiac Sparing with Upright Patient Geometry and Deep Learning

Authors: Shae Gans, Carri K. Glide-Hurst, Mark Pankuch, Chase Ruff, Niek Schreuder, Nicholas R. Summerfield, Yuhao Yan

Affiliation: Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Northwestern Medicine Proton Center, Northwestern Medicine Chicago Proton Center, Leo Cancer Care

Abstract Preview: Purpose: Novel upright patient positioners coupled with diagnostic-quality vertical CT at treatment isocenter introduce a significant opportunity for improved image-guided particle therapy. Treating p...

Advancing Flash Radiotherapy: Intercomparison of Parameters between Two Institutions to Optimize Clinical Applications.

Authors: Amir Abdollahi, Celine Karle, Michele M. Kim, Constantinos Koumenis, Andrea Mairani, Erato Stylianou Markidou

Affiliation: Heidelberg Ion-Beam Therapy Center - Department of Radiation Oncology, German Cancer Research Centre(DKFZ), University of Pennsylvania, Physics Dep. University of Cyprus

Abstract Preview: Purpose: The aim is to compare FLASH dose-rate RT generated with protons and carbon (HIT) and compare to protons (UPenn) to provide evidence for equipotency of FLASH vs. standard RT to tumor growth co...

An Evaluation of an SRS Quality Assurance System for Complex Patient Plans.

Authors: John Bennet, Indrin J. Chetty, Tai H. Dou

Affiliation: Department of Radiation Oncology,Cedars Sinai Medical Center, Department of Radiation Oncology, Cedars Sinai Medical Center, Department of Radiation Oncology,Cedars-Sinai Medical Center

Abstract Preview: Purpose:
To investigate the effect of complexity of stereotactic radiosurgery (SRS) volumetric modulated arc therapy plans on gamma pass rates (GPR) using a novel high-resolution ion chamber array ...

An International Multi-Institutional Espresso Study of Developing the Specialized-Equipment-Free Remote Audit for Single-Isocenter Multi-Target Stereotactic Radiosurgery

Authors: Juan-Francisco Calvo-Ortega, Andrew Cousins, Ashley Cullen, Andrew Dipulia, Peter B. Greer, Seng Boh Gary Lim, Shih-Chi Lin, D. Michael Lovelock, Conor McGarry, Victoria Robinson, Cameron Stanton, Baozhou Sun, Ching-Ling Teng, Gemma Warner, Benjamin J. Zwan

Affiliation: Northern Ireland Cancer Centre, Baylor College of Medicine, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Christchurch Hospital, Northwell, Central Coast Cancer Centre, Calvary Mater Hospital, Hospital Quironsalud Barcelona, Icahn School of Medicine at Mount Sinai, Chris O'Brien Lifehouse, University of Newcastle

Abstract Preview: Purpose: This multi-institution Electronic Silicon-based Remote Survey of Small-field Output (ESPRESSO) study aims to develop the remote audit process to evaluate the safety of single-isocenter multi-...

An International Survey of High Dose Rate Brachytherapy Dosimetry Practices

Authors: Anna Becker, Tomislav Bokulic, Mauro Carrara, Krzysztof Chelminski, Larry A. DeWerd, Alexis Dimitriadis, Benjamin Kellogg, Malcolm R. McEwen, Zakithi L.M Msimang, Mark J. Rivard, Thorsten Sander, Thorsten Schneider, Jamema Swamidas, Egor Titovich, Paula Toroi, Carlos E. de Almeida, Jacco de Pooter, Liset de la Fuente Rosales, Deborah G. van der Merwe

Affiliation: Radiation and Nuclear Safety Authority, University of Zagreb, National Physical Laboratory, IAEA, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Rio de Janeiro State University, Dosimetry Laboratory, Dosimetry and Medical Radiation Physics Section, Division of Human Health, International Atomic Energy Agency, Physikalisch-Technische Bundesanstalt, National Metrology Institute, University of the Witwatersrand, Dosimetry and Medical Radiation Physics Section, Division of Human Health, International Atomic Energy Agency, National Research Council, Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: The recently published IAEA-TRS-492 international code of practice (CoP) aims at improving traceability, accuracy, and consistency in Brachytherapy Dosimetry. To assess current approaches to ...

Assessing the Feasibility of LD-V1 Film for Annual Kilovoltage Imaging Dose Measurements

Authors: Maria F. Chan, Seng Boh Gary Lim, Shih-Chi Lin, Dustin W. Lynch, Usman Mahmood, Jeonghoon Park

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To explore the feasibility of using GafChromic LD-V1 film for annual imaging dose assessment across kV radiography, fluoroscopy, and cone beam computed tomography (CBCT) imaging protocols, as...

Assessment of the Dosimetric Characteristics of Brass Mesh Bolus in Electron Radiation Therapy

Authors: Hungcheng Hank Chen, Laura A. Doyle, Helena Frisbie-Firsching, Amy S. Harrison, Jackson D Reeves, Lindsay B Romak, Jon Strasser

Affiliation: Christiana Care

Abstract Preview: Purpose: Brass mesh bolus (BMB) is a high-density woven metal mesh which is an excellent alternative to tissue equivalent bolus in photon beams, offering improved surface conformality. Unlike utilizat...

Auto-Beam Hold Validation for Varian Sgrt Identify 3.0 on Truebeam Linear Accelerators

Authors: Hongyu Jiang, Wangyao Li, Dima Soultan, Fen Wang, Jun Xu

Affiliation: Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: To validate the Auto-Beam Hold functionality via the MMI connection between Varian SGRT system IDENTIFY 3.0 and treatment linacs.
Methods: A treatment plan was created in the Eclipse TPS u...

CBCT Dose Measurement for Common Protocols on Elekta Versahd and Varian Truebeam

Authors: Yingxuan Chen, Jun Li, Alexis N. Webb

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: Cone-beam computed-tomography (CBCT) is widely used for image-guided therapy. Cumulative dose from repeated CBCT might be a concern. This study aims to measure and compare the CBCT dose for c...

Characterization of Commercially-Available Dosimeters and Prototype Diamond Detectors for Absolute Flash Dosimetry of Small-Field Pulsed Proton Beams

Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang

Affiliation: 4Physikalisch-Technische WerkstÀtten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...

Characterizing and Modeling Higher-Order Motions of Collimator Subsystem on a 60RPM Gantry Linac for Improved Small Target Dosimetry

Authors: David J. Carlson, Yiu-Hsin Chang, Huixiao Chen, Zhe (Jay) Chen, Blake Gaderlund, Ray Yang

Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: To address the root cause of dosimetric discrepancy for small central targets (<2cm) especially sensitive to geometric alignment of beamlets, by modeling higher-order oscillations of the coll...

Checking of Sensitivity of Volumetric Modulated Arc Therapy Quality Assurance System with a Cavity Generation Method

Authors: Kaile Li, Esmail Parsai

Affiliation: Alexander T. Augusta Military Medical Center, Alexander T. Augusta Miliary Medical Center

Abstract Preview: Purpose: To evaluate the sensitivity of the portal dosimetry system with the Arc CHECK system at identical Volumetric Modulated Arc Therapy (VMAT) setup
Methods: An Arc CHECK system from Sun Nuclea...

Commissioning Silicone Tissue-Compensating Bolus for Electron Beam Therapy

Authors: Carla D. Bradford, Linda Ding, Yansong Geng, Alan Hartford, I-Lin Kuo, Salvatore LaRosa, Joshua N Wancura

Affiliation: University of Massachusetts Chan Medical School

Abstract Preview: Purpose: When treating nasal skin cancers, electron beam radiotherapy dose distributions can be improved by using custom bolus to compensate for uneven surfaces. Here we describe our experience commis...

Commissioning a Fixed Beamline Ultra-High Dose Rate Proton Therapy System

Authors: Ahmet S. Ayan, Austin M. Faught, Eunsin Lee, Julia Pakela

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University

Abstract Preview: Purpose: To present commissioning of a fixed beamline ultra-high dose rate proton pencil beam scanning system, the world’s first multi-room Varian ProBeam360⁰
Methods: The fixed beamline pencil bea...

Commissioning and Evaluation of Deviceless 4DCT

Authors: Christopher A. Aguilera, Hunter Tillery, Cheyann Windsor

Affiliation: Oregon Health & Science University, Northwest Medical Physics Center

Abstract Preview: Purpose: To demonstrate a method of acquiring 4DCT commissioning datasets for deviceless 4DCT which relies on an image-based algorithm instead of an external breathing signal for 4D image binning. The...

Commissioning of Elekta Leipzig and Valencia Skin Applicators

Authors: Hamid Aghdam, DJ Chen, Heather Chen, Sharad Goyal, Yonas Solomon Mekuria, Martin Ojong-Ntui, Yuan James Rao

Affiliation: The George Washington University, The George Washington University Cancer Center

Abstract Preview: Purpose: Elekta Leipzig and Valencia Skin applicators are designed to treat skin lesions. The applicators limit the irradiation to the required treatment area using a densimet shielding. Valencia uses...

Commissioning, Validation and Pilot Study of New Rpld System for Dosimetry Audits in Bulgaria

Authors: Gueorgui Gueorguiev, Katia Sergieva, Filip Simeonov, Tsvetelina Todorova, Bozhidar Vladimirov

Affiliation: National Centre of Radiobiology and Radiation Protection, Queen Giovanna University Hospital

Abstract Preview: Purpose: Dosimetry audit is an essential tool enhancing confidence in the accuracy of treatment delivery and in prevention of radiation treatment incidents. Current work depicts how novel nationwide r...

Comparative Evaluation of Spekpy for Kilovoltage Beam Quality Characterization

Authors: Chang Heon Choi, Yoonsuk Huh, Jin Jegal, Seonghee Kang, Jung-in Kim, Inbum Lee, Hyojun Park

Affiliation: Department of Radiation Oncology, Seoul National University Hospital

Abstract Preview: Purpose: This study evaluates SpekPy, a Python-based tool for modeling kilovoltage (kV) x-ray spectra, by comparing its calculated energy spectra, half-value layer (HVL), and air kerma with experiment...

Comparison Analysis of Three Kind of Solutions for Head and Neck Cancer VMAT Verification

Authors: Wenwen Bai

Affiliation: The Fourth Hospital of Hebei Medical University

Abstract Preview: Purpose: To compare three kind of solutions (EDR2 Film, MatriXX, COMPASS) for VMA quality assurance at head and Neck in Monaco plannig system.
Methods: Monacao 5.1 planning system optimazed 10 case...

Comprehensive Study of Recombination and Polarity Factors across CC04, CC13, FC65P, FC65G, Razor, and PP05 Chambers

Authors: Ziyad ABUBAKR ALHAREESHi, Ibtihaj Yussef Alhodire, Najla Sobhi Bin Shehima, Aram Mufteh A Genaw

Affiliation: Tripoli university hospital

Abstract Preview: Purpose:
This research investigates the recombination and polarity correcting factors for CC04, CC13, FC65P, FC65G, Razor, and PP05 ionization chambers to improve radiation dosimetry accuracy. Unde...

Decoupling Cardiorespiratory Motion of Cardiac Substructures Via 5D-MRI for Radiotherapy

Authors: Carri K. Glide-Hurst, Thomas M Grist, Kevin M. Johnson, Prashant Nagpal, Tarun Naren, Chase Ruff, Oliver Wieben, Jiwei Zhao

Affiliation: Department of Biostatistics and Medical Informatics, University of Wisconsin - Madison, Department of Radiology, University of Wisconsin-Madison, Department of Medical Physics, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison

Abstract Preview: Purpose: Cardiotoxicity is a devastating side effect for thoracic radiotherapy (RT). Currently, standard RT imaging is insufficient to decouple cardiorespiratory motion, limiting substructure-specific...

Design and Testing of an External Control System for Beam Control and Pre-Delivery Optimization for Conventional- and Ultra-High-Dose-per-Pulse Flash Irradiations

Authors: Alexander Baikalov, Luke Connell, Nicholas Coupey, Nolan M. Esplen, Rebecca Lim, Chinh Nguyen, Emil Schueler

Affiliation: Northwell, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: FLASH radiotherapy delivered using electron linear accelerators (LINAC) requires precise control and minimal variation of dose rate and We developed a robust external beam control system (EBC...

Detection of the Linac Jaw Face Angle Misalignment: Case Studies

Authors: Peter Balter, Andres V Cibrian, Song Gao

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The purpose of this study is to demonstrate a means of detecting misaligned jaw face angles on the Varian TrueBeam based on a beam symmetry metric for electron beam profiles.
Methods: Duri...

Development of a Novel 3D-Printed Heterogeneous Phantom for Liver SBRT Dose Verification in Hepatocellular Carcinoma (HCC) Treatment.

Authors: Dr. Sheaka Alobaidli, Anju K V, Dr. Chiranjib Konar, Sreejesh MS, Dr. Vijayaprabhu N, Dr. Deepti Sharma, Dr. Hanuman Prasad Yadav

Affiliation: Amity Institute of Applied Sciences, Kuwait Cancer Control Center, Institute of Liver and Biliary Sciences, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Amity institute of Applied Sciences, Amity University, Institute of Liver and Biliary Sciences(ILBS)

Abstract Preview: Purpose:
The accuracy of dose delivery in stereotactic body radiotherapy (SBRT) is critical for effectively treating hepatocellular carcinoma (HCC). This study aims to develop patient-specific 3D-p...

Development of the First Benchtop X-Ray Flash System

Authors: Ruirui Dong, Gernot Echner, Peter Haering, Clarence King, Carlos Murillo, Gavin Poludniowski, Nicholas Sammut, Joao Seco, Steffen Seeber, Maria Francesca Spadea, Elpida Theodoridou

Affiliation: KIT, Department of Physics and Astronomy, Heidelberg University, Karolinska Institutet, DKFZ, University of Malta

Abstract Preview: Purpose:
The goal is to develop the first benchtop X-ray FLASH system based on a conventional small animal irradiator. The small animal irradiator will be modeled using a Monte Carlo toolkit for bo...

Dose Rate Measurements of Scanning Carbon Ion Beams Using a Plastic Scintillator Detector

Authors: Motohiro Kawashima, Adrian Kugara, Masao Nakao, Shuichi Ozawa, Mutsumi Tashiro, Maria Varnava

Affiliation: Gunma University Heavy Ion Medical Center, Hiroshima High-Precision Radiotherapy Cancer Center

Abstract Preview: Purpose: This study aimed to evaluate the time-dependent dose rate characteristics of a scanning carbon ion beam using a fast-response plastic scintillator detector (PSD), with a focus on its potentia...

Dosimeteric Parameter Evaluation of Digital Polycrystalline Semiconductor Dosimeters for Quality Assurance of High-Dose-Rate Brachytherapy

Authors: Woong Cho, Jin-Beom Chung, Moo-Jae Han, Sang Won Kang, Boram Lee

Affiliation: Department of Radiation Oncology, Seoul National University Boramae Medical Center, Department of Radiation Oncology, Seoul National University Bundang Hospital, Department of Radiation Oncology, Inha University Hospital

Abstract Preview: Purpose: This study aims to establish a digital quality assurance (QA) system for high-dose-rate (HDR) brachytherapy by evaluating self-developed polycrystalline semiconductor dosimeters (PSDs).
Me...

Dosimetric Accuracy Evaluation of Brainlab Elements 4.0 Treatment Planning System

Authors: Bhuvaneswari Narayanan, Niko Papanikolaou, Daniel L. Saenz

Affiliation: UT Health San Antonio, University of Texas HSC San Antonio

Abstract Preview: Purpose: To evaluate dosimetric accuracy of Brainlab Elements (BLE) 4.0 treatment planning system (TPS) for linac based SRS and Spine SBRT treatment.
Methods: RT Safe cranial and thorax phantoms wi...

Dosimetric Characterization of Spatial Fractionation Collimator for Ultra-High Dose Rate Electron Beam

Authors: Lily Jo Bertemes, Careesa Billante, Ashley Cetnar, Arnab Chakravarti, Nilendu Gupta, Sagarika Jain, Maximilian Stephen Meineke, Allison N. Palmiero, Runhe Tan

Affiliation: The Ohio State University - James Cancer Hospital, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Department of Radiation Oncology, Ohio State University Comprehensive Cancer Center, The Ohio State University, The James Cancer Center

Abstract Preview: Purpose: Ultra-High Dose Rate Radiation Therapy (UHDR-RT) induces normal tissue sparing while maintaining iso-effective tumor control compared to conventional methods, known as the “FLASH effect”. How...

Dosimetric Characterization of Sun Nuclear EDGE Diodes in the Plateau Region of Proton Pencil Beam Scanning (PBS) Fields

Authors: Wesley S. Culberson, Ryan Gardner, Patrick M Hill, Mark Pankuch, Karsten K. Wake

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Wisconsin, Northwestern Medicine Proton Center

Abstract Preview: Purpose: To assess the dosimetric capabilities of Sun Nuclear (Melbourne, FL) EDGE Diode Detectorsℱ for measurements in the plateau region of pencil beam scanning (PBS) fields. Many clinical dosimeter...

Dosimetric Comparison & Error Analysis of Aapm TG51 & WGTG51-e Protocol with Icru-90 Key-Data for High-Energy Clinical Electron Beam

Authors: Amar K. Basavatia, Sandeepan Ganguly, Lee C. Goddard, Wolfgang A. Tomé

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: To investigate the dosimetric impact of WGTG51-e Report 385, recently updated CoP for clinical electron beams. This study uses a chamber specific effective point of measurement (EPOM) shift t...

Dosimetric Evaluation of Comprehensive Motion Management in 1.5T MR-Linac for Real-Time Gated Radiotherapy

Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wah Kong, Ka Ki Lau, Pei-Xiong Li, Pak Hang Nam, Mei Yan Tse, Jierong Wang, Bin Yang, Siu Ki Yu, Jing Yuan, Chi To Yung, Shang Peng Felix Yung

Affiliation: Medical Physics Department, Hong Kong Sanatorium and Hospital, Research Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: Intrafraction motion management remains a major challenge in magnetic resonance-guided radiotherapy (MRgRT). The recent clinical release of an active motion management system aims to enhance ...

Dosimetric Parameter Cross-Check Evaluations for Dedicated Biologically-Guided Radiotherapy Linac Using Two Water Phantom Systems

Authors: Nguyen Phuong Dang, Mason Hazlett, Lijun Ma, Yutaka Natsuaki, William T. Watkins, Zhengzheng Xu, Timothy Pok Chi Yeung

Affiliation: Reflexion Medical Inc,, Radiation Oncology, Keck School of Medicine of USC, RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: This is the first study reporting the beam dosimetric parameter cross-checks of Reflexion linac using different water phantom systems and detectors. The difference in measurements using diffe...

Dosimetry Commissioning of a Commercial Cabinet X-Ray Irradiator for Small Animal Irradiation

Authors: Sang Hyun Cho, Amrit Kaphle, Sunil Krishnan, Neerajan Nepal

Affiliation: The University of Texas MD Anderson Cancer Center, The University of Texas Health Science Center

Abstract Preview: Purpose: To determine the basic dosimetry parameters and characteristics of a commercial cabinet x-ray unit for small animal irradiation as well as the specific dosimetry parameters for concurrent irr...

Effects of Enhanced Leaf Modeling on Single-Isocenter Multi-Target Stereotactic Radiosurgery Dose Accuracy

Authors: Thomas R. Mazur, Kevin Renick, Matthew C. Schmidt, Xiaodong Neo Zhao

Affiliation: Washington University in St. Louis School of Medicine, Washington University School of Medicine

Abstract Preview: Purpose: To compare dose calculation accuracy for single-isocenter multi-target stereotactic radiosurgery plans (SIMT-SRS) in Eclipse V18.0 with enhanced leaf model (ELM) using the anisotropic analyti...

Evaluating Pulse Normalization for Enhanced Ion Chamber Signal Correction in Relative Dosimetry during Beam Scanning

Authors: Alejandro Cuadra, Paulina E. Galavis, Juan Leal, Enrique Lozano, Franklin Reggio, Gabriel Zelada

Affiliation: ClĂ­nica Iram, Clinica Alemana, Hospital ClĂ­nico de Magallanes, E&G Medical Systems Ltda, NYU Langone Health

Abstract Preview: Purpose: To investigate and compare the new method “Pulse Normalization” proposed by Sun Nuclear to correct ion chamber signal for fluctuations in the accelerator output while performing relative dosi...

Evaluating the Impact of Beam Spot Spacing on Dose Rates and Field Uniformity for Small Animal Proton Ultra-High Dose Rate Irradiation

Authors: Jack Biondo, Audrey Magness, Anthony E. Mascia, Zhiyan Xiao, Yongbin Zhang

Affiliation: Cincinnati Children's Proton Therapy Center

Abstract Preview: Purpose: Proton FLASH-RT has shown promise reducing normal tissue toxicity while maintaining tumor control. However, in vivo experiments critically depend on achieving ultra-high dose rate (UHDR) and ...

Evaluation of Charge Collection Performance in the A30 Prototype Parallel Plate Ion Chamber in Ultra-High Dose Rate Beam

Authors: Mervat A. Alharbi, Wesley S. Culberson

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Medical Physics Department, School of medicine and Public Health, University of Wisconsin-Madison

Abstract Preview: Purpose: The charge collection using ionization chambers is challenging at ultra-high dose rates (UHDR) due to the high ion recombination The Exradin A30 prototype parallel-plate ion chamber manufactu...

Evaluation of Concomitant Imaging Dose in 4D-CBCT Guided Thoracic Radiotherapy

Authors: Yuchao Hu, Yajun Jia, Zhangmin Li, Yong Sang, Jianan Wu, Man Zhao

Affiliation: Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Guangzhou Concord Cancer Hospital, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: To evaluate the imaging dose of 4D-CBCT in patients treated with thoracic radiotherapy.
Methods: A model of the Elekta XVI imaging system was created in TOPAS software. Percentage depth do...

Evaluation of Ion Chamber Performance and Suitability for Flash Proton Therapy Dosimetry

Authors: Seohyeon An, Yoonsun Chung, Seonghoon Jeong, Seongmoon Jung, Chae-Eon Kim, In Jung Kim, Sung Hun Kim, Se Byeong Lee, Sang-il Pak, Jong In Park

Affiliation: POHANG ACCELERATOR LABORATORY, Hanyang University, Korea Research Institute of Standards and Science (KRISS), Ilsan Paik Hospital, National Cancer Center, National Cancer Center Korea, Korea Research Institute of Standards and Science

Abstract Preview: Purpose: To evaluate the performance of three ion chambers—Advanced Markus (AMC), PinPoint, and Roos—under FLASH proton beam conditions and assess the response of the nozzle monitor chamber for their ...

Evaluation of the Hyperscint RP-200 Plastic Scintillation Dosimetry System for Reference Dosimetry in Ultra-High Dose Rate Electron Beam Therapy: A Comparative Study

Authors: Julie Colnot, Eric Deutsch, Christelle Huet, Danahé LeBlanc, Pauline Maury, Charlotte Robert, Imane Saïd Mansour, Cathyanne Schott, Francois Therriault-Proulx

Affiliation: INSERM U1030, Gustave Roussy, University Paris-Saclay, LDRI, IRSN, Medscint, THERYQ / INSERM U1030, Gustave Roussy, University Paris-Saclay, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique

Abstract Preview: Purpose: FLASH radiotherapy, using ultra-high dose rates (UHDR, >100 Gy/s), spares healthy tissues while maintaining tumor control compared to conventional radiotherapy (CONV). However, UHDR dosimetry...

Evaluation of the Improvements of a New Leaf Model (Enhanced Leaf Model) for the Halcyon

Authors: Evan Barber, Gloria P. Beyer, Callum Hartley, Jordi Saez, Philip Wheeler

Affiliation: Department of Radiation Oncology, Hospital Clinic de Barcelona, Department of Radiotherapy Physics, Velindre University NHS Trust, Medical Physics Services, LLC

Abstract Preview: Purpose: To evaluate the Enhanced Leaf Model (ELM) in Eclipse v18 to the standard leaf model for the Halcyon multileaf collimator (MLC) using a measurement-based method.
Methods: The Halcyon’s doub...

Feasibility Study of Using HDR1000+ Well-Type Ionization Chambers for Solution Based 90y Measurements

Authors: Denis Bergeron, Larry A. DeWerd, Sean Jollota, Peyton Alexandra Lalain, Likhitha Polepalli

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, National Institute of Standards and Technology

Abstract Preview: Purpose: 90Y is a challenging radionuclide to measure because it is a pure beta-emitter and is typically quantified using a radionuclide calibrator. These devices, such as the Capintec model used in t...

Feasibility Study of the Auger Electron Radiation Therapy

Authors: Chen-Ju Feng, Shih-Ming Hsu, Chin-Hsiung Lin, Shih-Yong Luo, Shao-Chun Tseng, Chin-Hui Wu, Ya-Ru Yang

Affiliation: National Yang Ming Chiao Tung University, Koo Foundation Sun Yat-Sen Cancer Center, Tzu-Chi University, NanoRay Biotech Co., Ltd

Abstract Preview: Purpose: The range of auger electrons in water is 2~500 nm, and its linear energy transfer reaches 26 keV/ÎŒm. This study investigated the feasibility of the auger electron radiation therapy.
Method...

Feasibility of Using 68ga-PSMA for Biology-Guided Radiotherapy (BgRT) Treatment

Authors: Girish Bal, Thomas I. Banks, Bin Cai, Neil Desai, Aurelie Garant, Orhan Oz, Elizeva Phillips, Rameshwar Prasad, Chenyang Shen, Robert Timmerman

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical

Abstract Preview: Purpose: This study reports findings from the first-in-human imaging-only trial evaluating the feasibility of using the novel PET tracer 68Ga-PSMA-11 (Illuccix) to guide external beam radiotherapy on ...

Field Output Correction Factors of Novel Shielded and Unshielded Silicon Diode Detectors

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum fĂŒr Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize field output correction factors of novel shielded and unshielded silicon diode detectors.
Methods: Novel shielded and unshielded Silicon Diode Detectors (SDD) were characte...

First Phantom Testing of Biology-Guided Radiotherapy for Sequential Integrated Boost Radiotherapy

Authors: Girish Bal, David J. Carlson, Huixiao Chen, Zhe (Jay) Chen, Emily A. Draeger, Dae Yup Han, Henry S. Park

Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: This study explores the feasibility, accuracy, and dosimetric performance of hybrid biology-guided radiotherapy (BgRT) combined with image-guided radiotherapy (IGRT) for delivering sequential...

First-Time Live Imaging of Radiopharmaceutical Administration with a Hybrid Compton Camera

Authors: Ramesh Boggula, Jay W. Burmeister

Affiliation: Wayne State University, Karmanos Cancer Center, Gershenson ROC, Wayne State University School of Medicine

Abstract Preview: Purpose: This study evaluated the performance of a hybrid Compton camera for real-time imaging during the administration of Lu-177-based radiopharmaceuticals, including Pluvicto and Lutathera. The aim...

HDR End-to-End Testing of Horizontal Leipzig Skin Applicators with Ir-192 Calibrated Oslds

Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Nadia M. Vassell

Affiliation: Mount Sinai Beth Israel

Abstract Preview: Purpose: Commissioning of Flexitron HDR horizontal Leipzig applicators typically includes indirect or direct output verification, using a well chamber specific Revised Correspondence Factor (CFrev) or...

High Dose Rate Electron Beam Depth Dose Characterization

Authors: Fitria P Krisna, Mardon Limena, Supriyanto Ardjo Pawiro, Jhon H Saragih, Wahyu E. Wibowo, Poonam Yadav, Ummu M Zahro

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Radiation Oncology Dr. Cipto Mangunkusumo National Central Public Hospital, Department of Physics, Mathematics and Natural Sciences, University of Indonesia, Department of Radiotherapy, Mandaya Hospital, Department of Radiation Oncology, Mitra Keluarga Kenjeran Hospital, Department of Radiotherapy, Mandaya Royal Hospital, Radiation Oncology, Santosa Hospital

Abstract Preview: Purpose: To perform depth dose characteristics of High Dose Electron Beam and utility of various commercially available detectors.
Methods: The measurements were performed using an Elekta Versa HD ...

High-Energy Current Detectors for Proton Dose-Rate Beam Monitoring at Flash Dose-Rates.

Authors: Davide Brivio, Lia Carroll, Juliane Daartz, Jan PO Schuemann, Piotr Zygmanski

Affiliation: Massachusetts General Hospital, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: We employ High-Energy Current (HEC) detectors for real-time monitoring of proton beams at conventional to FLASH dose rates. This would help overcome the need for fast and accurate dosimeters ...

High-Fidelity Monte-Carlo Model Development and Validation of a 0.5T Bi-Planar Linac-MR Using Topas: Multileaf Collimator Modeling, Positioning, and Dose Verification in Slab Phantoms

Authors: B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Gawon Han, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip

Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute

Abstract Preview: Purpose: To develop and validate a high-fidelity Monte-Carlo (MC) model of a 0.5T bi-planar Linac-MR in TOPAS, focusing on accurate Multileaf Collimator (MLC) modelling and positioning for open apertu...

Hyperbaric Oxygen Therapy Prior to SRS Does Not Enhance Radiosensitivity in the Murine Glioblastoma Model

Authors: Beverly Allen, Jay C. Buckey, David J. Gladstone, P. Jack Hoopes, David I Hunter, Armin Tavakkoli

Affiliation: Thayer School of Engineering, Dartmouth College, Geisel School of Medicine, Dartmouth College, Geisel School of Medicine, Thayer School of Engineering

Abstract Preview: Purpose: Hyperbaric oxygen (HBO) therapy immediately prior to radiation therapy has been proposed as treatment to enhance radiosensitivity of hypoxic tumors. A murine glioblastoma model was utilized t...

Impact of Ion Chamber Selection on Enhanced Leaf Modeling Predictions of Dosimetric Leaf Gap and Leaf Transmission Factors

Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny

Affiliation: Department of Radiation Oncology, University of Rochester

Abstract Preview: Purpose: A new multileaf collimator (MLC) model has been introduced in Varian Eclipse v18.0, with the treatment planning system (TPS) explicitly modeling the leaf end effects. The vendor recommends a ...

Impact of Photon Beam Energy and Symmetry on the Radial Profile Correction Factor for FFF Beams

Authors: Wesley S. Culberson, Larry A. DeWerd, Ahtesham Ullah Khan, Zachary James Welchel

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, University of Wisconsin-Madison

Abstract Preview: Purpose: Flattening filter free (FFF) linac beams exhibit a centrally peaked beam profile due to the forward-directed bremsstrahlung production from MeV electrons, leading to volume averaging effects ...

Implementing TG-191 for Robust Calibration of Scintillation Imaging As a Clinical dosimetry Tool

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Lesley A Jarvis, Allison Matous

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose: Scintillation imaging has demonstrated unique advantages to existing clinical in vivo dosimetry (IVD) techniques by enabling full-field visualization, direct comparison to the treatment plan,...

Improving Output Stability with Angular Correction Factor on Pencil Beam Scanning Proton System

Authors: Akbar Anvari, Carnell J. Hampton, Melanie R. Piantino, Kai Yang

Affiliation: Levine Cancer Institute, Atrium Health

Abstract Preview: Purpose: To evaluate the effectiveness of angular correction factor for output stability on Mevion S250i Hyper scanning machine, which allows user to apply correction factors for output at selected ga...

Improving Patient Safety with MRI Visible Laterality Markers

Authors: Ndey Badjan, Chris Beasley, Issack Boru, Josh Joyner, Erica Owenby, Scott H. Robertson, Nicholas Said

Affiliation: Duke University Health System

Abstract Preview: Purpose:
To design MRI-visible laterality markers to boost patient safety by minimizing errors in laterality and subsequent procedures.
Methods:
The markers were made using commercially avail...

Initial Comparison of 3D CBCT Performance: New Mobile C-Arm Vs. O-Arm Unit

Authors: Wendy Siman, Wei Zhou

Affiliation: University of Colorado Anschutz Medical Campus, School of Medicine

Abstract Preview: Purpose:
To compare the image quality and radiation dose of 3D cone-beam CT modes of a mobile C-arm and an O-arm unit for intraoperative imaging.
Methods:
A 50-”m tungsten wire was imaged at ...

Inter-Machine Harmonization in Echocardiographic Videos for Predicting Left Ventricular Ejection Fraction

Authors: Akihiro Haga, Ren Iwasaki, Kenya Kusunose, Makoto Miyake, Kenji Moriuchi, Yasuharu Takeda, Hidekazu Tanaka, Hirotsugu Yamada

Affiliation: Department of Cardiovascular Medicine, Nephrology, and Neurology Graduate School of Medicine, University of the Ryukyus, Graduate School of Biomedical Sciences, Tokushima University, Tokushima university, Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Department of Cardiology, Tenri Hospital, Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Division of Heart Failure, Department of Heart Failure and Transplant, National Cerebral and Cardiovascular Center

Abstract Preview: Purpose: Device dependency is a significant challenge in medical AI, potentially limiting generalization performance. This study aimed to develop a robust deep learning model for predicting left ventr...

Inter-System and Inter-Layer Dlg Variations in Halcyon/Ethos Mlcs: Implications for Dosimetric Matching and User-Adjustable TPS Models

Authors: Evan Barber, Gloria P. Beyer, Matthew J. Daniels, Callum Hartley, Jordi Saez, Philip Wheeler

Affiliation: TrueNorth Medical Physics, Department of Radiotherapy Physics, Velindre University NHS Trust, Department of Radiation Oncology, Hospital Clinic de Barcelona, Medical Physics Services, LLC

Abstract Preview: Purpose: To quantify inter-system and inter-layer dosimetric leaf gap (DLG) variations in Halcyon/Ethos multileaf collimators (MLCs) using custom sweeping gap tests, and to evaluate implications for c...

Ir-192 Percentage Depth Ionization of PLA and Ballistic Gelatin Compared to Water

Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Ching-Ling Teng, Nadia M. Vassell

Affiliation: Northwell, Mount Sinai Beth Israel

Abstract Preview: Purpose:
The flexible nature of ballistic gelatin and 3D printed material such as PLA lend themselves to phantom studies in brachytherapy. While these materials can allow for easy simulation of cat...

Longitudinal CMR Strain Analysis of Right Ventricular (RV) Function across Aging in Offspring of Baboons Exposed to Moderate Maternal Undernutrition

Authors: Geoffrey D. Clarke, Laura A. Cox, Alexander J Moody, Peter W Nathanielsz, Bowen Yang

Affiliation: Wake Forest University School of Medicine, University of Texas Health Science Center at San Antonio, Texas Biomedical Research Institute

Abstract Preview: Purpose:
Recent studies show diagnostic value of myocardial strain analysis for left ventricular (LV) function using cardiac magnetic resonance imaging (CMR). RV function analysis is more challengi...

Management of 4D CBCT Dose for Patients with Implanted Cardiac Devices

Authors: Won Chang, Vadim L. Stakhursky, Yevgeniy Vinogradskiy

Affiliation: Jefferson Einstein, Alliance Cancer Specialists, Thomas Jefferson University

Abstract Preview: Purpose: 4DCBCT is a powerful tool for localization of moving targets when treating lung tumors with hypofractionated regimens (SBRT). However, for patients with implanted cardiac devices (ICD) in clo...

Mobetron Quality Assurance Tools

Authors: Robert A. Dahl

Affiliation: Mayo Foundation

Abstract Preview: Purpose: To develop tools to simplify/accelerate the quality assurance testing of the Mobetron mobile linear accelerator and increase safety when moving it to different OR’s.

Methods: The Mobet...

Modality-Agnostic Image Cascade (MAGIC) for Multi-Modality Cardiac Substructure Segmentation

Authors: Ming Dong, Carri K. Glide-Hurst, Qisheng He, Anudeep Kumar, Alex Singleton Kuo, Joshua Pan, Chase Ruff, Nicholas R. Summerfield

Affiliation: Department of Computer Science, Wayne State University, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Recent evidence highlights the importance of incorporating cardiac substructures (CS) into treatment planning for thoracic cancers, however current segmentation methods are limited to a singl...

Modernization of the NIST Air-Kerma Strength Standard for LDR Brachytherapy Seeds

Authors: Michael G. Mitch, Csilla I. Szabo-Foster

Affiliation: National Institute of Standards and Technology

Abstract Preview: Purpose: The U.S. air-kerma strength standard for low-dose-rate (LDR) low-energy photon-emitting brachytherapy sources provides measurement traceability for calibrations at the AAPM Accredited Dosimet...

Monitor Unit (MU) Substructure Analysis for Low MU Deliveries

Authors: Indra J. Das, Ahtesham U. Khan, Andrew J. White, Poonam Yadav

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine

Abstract Preview: Purpose: During intensity modulated radiotherapy (IMRT) planning, low MU segments (< 3 MU) are commonly avoided due to documented dosimetric nonlinearity and poor reproducibility. This work aims to ex...

Monte Carlo Derived Correction Factors for Ion Chambers Used in the Calibration of Gamma Knife Perfexion Model: Impact of Phantom Materials and Chamber Orientation on Dosimetric Accuracy

Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: Commissioning of a Gamma KnifeÂź (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...

One Year Experience of Biology-Guided Radiotherapy (BgRT) on PET-Linac in an Academic Center

Authors: Shahed Badiyan, Girish Bal, Thomas I. Banks, Bin Cai, Tu Dan, Aurelie Garant, Andrew R. Godley, Steve Jiang, Orhan Oz, Arnold Pompos, Rameshwar Prasad, Chenyang Shen, David Sher, Robert Timmerman, Kenneth Westover

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical

Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) is a novel FDA-cleared technology for treating lung and bone tumors based on 18F-FDG PET uptake. This study summarizes the first-year experience treating 29...

Optimized Methodology for Accurate Half-Value Layer Measurement in Preclinical X-Ray Cabinet Systems

Authors: Paolo Pellicioli, Mohammad Rezaee, Ehsan Tajikmansoury, John W. Wong

Affiliation: Institute of Anatomy, University of Bern, Baltzerstrasse, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine

Abstract Preview: Purpose: Half-value layer (HVL) is a critical parameter for commissioning and quality assurance of preclinical x-ray irradiators. However, measuring HVL in cabinet systems presents challenges due to s...

Optimizing Low-Dose Imaging Parameters for Dual-Energy Cone-Beam Computed Tomography in Image-Guided Radiation Therapy

Authors: Sebastien A. Gros, Hyejoo Kang, Andrew Keeler, Luke Layman, Jason Patrick Luce, Ha Nguyen, John C. Roeske

Affiliation: Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago

Abstract Preview: Purpose:
This study aims to optimize virtual monoenergetic (VM) images obtained from dual-energy (DE) cone-beam computer tomography (CBCT) protocols for Image-Guided Radiation Therapy (IGRT). The o...

Preclinical Dosimetric Evaluation for Small Animal Study to Investigate Normal Tissue-Sparing Effects in the Electron Ultra-High Dose-Rate (FLASH) Environment

Authors: Ashok Bhandari, Andrew Joseph Fanning, Kyle J. Gallagher, Brendan Graff, Christopher Jenkins, Kyuhak Oh, Ying Yan, Su-Min Zhou

Affiliation: University of Nebraska Medical Center

Abstract Preview: Purpose: This study aimed to design a robust experimental setup to ensure accurate dose delivery using ultra-high-dose-rate for small animal experiments by conducting dosimetric evaluations prior to a...

Proton CT-Imaging and Radiography Using 3D-Detector with Plastic Scintillators for on-Board Proton Imaging

Authors: Salahuddin Ahmad, Imad M. Ali, Zaid Alkalani, Nesreen Alsbou

Affiliation: University of Oklahoma, University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: To design and evaluate a 3D-detector for proton CT-imaging and radiography, utilizing volumetric plastic scintillator detector exposed to high-energy therapeutic beams from proton therapy sys...

Proton Minibeam Radiotherapy: Commissioning, Treatment Planning, and Delivery

Authors: Stephen M Corner, Daiki Hara, Jiasen Ma, Robert W Mutter, Mark D. Pepin, Nicholas B. Remmes, Hok Seum Wan Chan Tseung

Affiliation: Mayo Clinic - Rochester

Abstract Preview: Purpose: Proton minibeam radiotherapy (pMBRT) is a form of spatially fractionated radiation therapy leveraging submillimeter beams to improve the therapeutic ratio. We report on collimator design, com...

Pulse-Based Method of Electrometer Calibration for High Instantaneous Currents Produced in Ultra-High Dose per-Pulse Electron Beams

Authors: Wesley S. Culberson, Miguel Angel Flores Mancera, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Electrometers are fundamental instruments for absorbed dose determination, and their accuracy is strongly dependent on their calibration. The standard procedure of electrometer calibration is...

QA Your QA:3 Steps to Ensure a Robust QA Review Workflow.

Authors: Shahid B. Awan, Harold Li, Aba Lippuner

Affiliation: Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: QA review is a necessary component of QA management but is often pushed aside owing to time constraints and overreliance on vendor solutions. At our multicenter institution, we designed a 3-s...

Radiation Shielding Considerations for Ultra-High Dose Rate Electron Flash Radiation Therapy

Authors: Alexandru Badalan, Peter Petric, I. Antoniu Popescu, Andrew Kyle Henderson Robertson

Affiliation: Bc Cancer, BC Cancer - Vancouver, BC Cancer

Abstract Preview: Purpose: Ultra-high dose rate (>40 Gy/s) or “FLASH” radiation therapy (RT) has the potential to improve cancer treatment through reduced radiation side effects. While electron FLASH beams can be produ...

Rapid 3D Prototyped Solid-Source Phantoms for Quality Assurance of Biology-Guided Radiotherapy (BgRT)

Authors: Jon Burns, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma

Affiliation: RefleXion Medical

Abstract Preview: Purpose: To simplify BgRT testing we have developed techniques that use 3D resin printed structures that can be filled with Ge-68 epoxy. This approach allows the development of highly complex, clinica...

Reduction of the Charge Build-up Effect on the Beam Current Transformers for Real-Time Monitoring of Ultra-High Dose per-Pulse Electron Beams

Authors: Wesley S. Culberson, Miguel Angel Flores Mancera, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Beam current transformers (BCTs) are a promising alternative to ion chambers for real-time monitoring of ultra-high dose per-pulse (UHDPP) beams. The signal of the BCT is insensitive to ion r...

Relative Optimized Linearization for Film Dosimetry with Non-Uniformity Correction

Authors: Piotr Pater, Nicholas G. Zacharopoulos

Affiliation: McGill University, Medical Physics Unit, Gerald Bronfman Department of Oncology, McGill University

Abstract Preview: Purpose: To develop a method for accurate relative film dosimetry that incorporates non-uniformity
corrections.
Methods: The accuracy of Devic’s [1] linearization approach was evaluated using si...

Scan Efficiency and Imaging Dose Analysis of Next-Generation Nonstop Gated CBCT for Respiratory Gating Lung Radiotherapy

Authors: Sean L. Berry, Weixing Cai, Laura I. Cervino, Yusuf Emre Erdi, Yabo Fu, Yiming Gao, Daphna Gelblum, Wendy B. Harris, Xiuxiu He, Tianfang Li, Xiang Li, Seng Boh Gary Lim, Jean M. Moran, Mitchell Yu, Hao Zhang

Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Gated CBCT (gCBCT) is commonly employed for respiratory gating lung cancer patients to ensure precise patient setup. However, the scan is time-consuming on C-arm linear accelerators (LINAC) d...

Small Fields Output Factor Measurements in 1.5 MR-Linac

Authors: Thomas I. Banks, Tsuicheng D. Chiu, Viktor M. Iakovenko, Christopher Kabat, Chang-Shiun Lin, Mu-Han Lin, Arnold Pompos

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX

Abstract Preview: Purpose: The superior soft-tissue contrast provided by MR imaging offers favorable conditions for the effective application of stereotactic body radiation therapy (SBRT). Accurate small field dosimetr...

Spatial Variation and Dosimetry of X-Ray Contamination in Total Skin Electron Beam Therapy

Authors: William G. Breen, Dalton Griner, Scott C Lester, Joseph John Lucido, Beth A. Schueler, Jack C. Thull

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Designing a total skin electron (TSE) beam therapy protocol requires finding the optimal balance between penetration depth, field uniformity, and x-ray contamination (XC). To better understan...

Spatially Informed Auto-Segmentation of Cardiac Nodes for Radiotherapy Treatment Planning

Authors: Ming Dong, Carri K. Glide-Hurst, Joshua Pan, Nicholas R. Summerfield

Affiliation: Department of Computer Science, Wayne State University, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Radiation dose to the cardiac nodes is more strongly associated with conduction disorders and arrythmias than whole heart (WH) metrics. However, node segmentation is challenging due to comple...

Streamlined Calibration of Mosfet Dosimeters for Radixact Systems: Addressing Angular Dependence and Beam Profile Challenges

Authors: Guang-Pei Chen, Renae Conlin, Juan A. Garcia-Alvarez, Kirk Morris, Haidy G. Nasief, Eenas A. Omari, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Cumulative dose limits make replacing and calibrating Metal Oxide Semiconductor Field Effect dosimeters (MOSFET-d) used for in-vivo dosimetry a common clinical task. Calibration protocols for...

The Use of a Milled NIST Traceable Tld for End-to-End Validation in Mlc and Cone SRS Programs.

Authors: Ross Bland, Zachary A. Christ, Sophy Mangana, Feba Mathew, Stephanie K. Phoenix, Joseph Salloum, Jason D. Stanford, William Zollinger

Affiliation: Forrest General Cancer Center, Northeast Louisiana Cancer Institute, Florida Atlantic University

Abstract Preview: Purpose: The objective of this paper is twofold: 1) to explore the efficacy of using referenced beam models supplied by the vendor (Brainlab) and 2) the efficacy of NIST traceable TLD for end-to-end v...

Towards Arbitrary Phantom Patient Specific IMRT QA on Reflexion X1

Authors: Andrew Groll, Ayan Mitra, PhD, Manoj Narayanan, Sanchit Sharma, Ray Yang, Timothy Pok Chi Yeung

Affiliation: Reflexion Medical Inc,, RefleXion Medical

Abstract Preview: Purpose: To develop a versatile QA tool enabling dose recalculation of a patient’s plan sinogram redeployed onto arbitrary replacement phantom geometry, and extract computed dose along detector planes...

Treatment Dose Reconstruction of Digitized Deliveries on Reflexion X1 System Based on Megavoltage Imager and Dose Monitor Chamber

Authors: Angela J Da Silva, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, David W. Meer, Manoj Narayanan, Mingshan Sun, Don Vernekohl, Ray Yang

Affiliation: RefleXion Medical

Abstract Preview: Purpose: To implement post-treatment review of delivered dose fractions on RefleXion X1 accounting for independent detection of transmitted beamlets and transient dose fluctuations of individual pulse...

Treatment Machine Matching for ELM in Eclipse v18.0 By Adjusting Physical Leaf Gap

Authors: Quyen Duong, Si Young Jang, Soyoung Lee, Samuel Ming Ho Luk

Affiliation: Boston University, Department of Radiation Oncology, University of Vermont Medical Center, Boston Medical Center

Abstract Preview: Purpose: To investigate the clinical impact of physical MLC gaps changes with Millennium 120 MLC on Enhanced Leaf Modeling (ELM) and patient plans, and to establish a new MLC model in Eclipse v18.0 on...

Treatment Planning System Modelling of a New Commercial Rotational Table

Authors: Michael Armstrong, Courtney R. Buckey, Quan Chen, Suzanne J. Chungbin, Mirek Fatyga, Yi Rong, Jun Tan, Xiang Sheng Yan

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: To model a commercial rotational table in treatment planning system (TPS) for accurate dose optimization and calculation.

Methods: A commercial rotational table (CDR EquilibriumÂź) is r...

Ultra-Fast Commissioning and Quality Assurance with Plastic Scintillation Detector

Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din

Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University

Abstract Preview: Purpose: Accurate, efficient, and reliable commissioning of linear accelerator (LINAC) is critical for ensuring high-quality radiation therapy treatments. The study uses advanced detector technology a...

Universal Range Modulators for Flash Proton Therapy: 3D Printing of Stackable Variable Density Units

Authors: Eric S. Diffenderfer, Lei Dong, Alejandro Garcia, Wenbo Gu, Michele M. Kim, Alexander Lin, Kai Mei, Peter B. Noël, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: We present a novel 3D-printed range-modulating devices with spatially modulated density for FLASH particle therapy. By varying density distributions, spread-out Bragg peaks(SOBPs) can be gene...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...

Validation of Radiopharmaceutical Therapy (RPT) Dose Calculation Platforms from Absolute Absorbed Dose Measurement of 225ac

Authors: Bryan Bednarz, Larry A. DeWerd, Sean Jollota, Ahtesham Ullah Khan, Ohyun Kwon, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: The accurate quantification of absorbed dose is essential for alpha-emitting radionuclides used in radiopharmaceutical therapy (RPT). This study presents the first direct comparison of physic...

dosimetric Characterization of Tungsten Eye Shields Using Monte Carlo Simulation

Authors: Omer Abdulaziz Ali, Robin Hill, Nathan Huntelerslag

Affiliation: Waikato Hospital, Hamilton, New Zealand, Central Coast Cancer Centre, Gosford, Australia

Abstract Preview: Purpose: Characterizing transmission through eye shields is essential to understanding dose distribution in underlying tissues. This study aims to utilize Monte Carlo (MC) simulations to model and cha...