Search Submissions 🔎

Results for "dosimetry performed": 76 found

A 3D Printed Ion Chamber Insert Solution for Absolute Dosimetry with Varying Ionisation Chambers in Radiosurgery.

Authors: Shashanksharad Kale, Gopishankar Natanasabapathi, Daya Nand Kishore Sharma

Affiliation: All India Institute of Medical Sciences (AIIMS), Department of Radiation Oncology, All India Institute of Medical Sciences

Abstract Preview: Purpose:
The study demonstrates a novel 3D printing method to fabricate an ion chamber insert (ICI) for absolute dosimetry purpose in gamma knife radiosurgery (GKRS).
Methods:
Our institute u...

A Beagle Dog Mesh-Type Phantom for Application to Nuclear Medicine and Internal Dosimetry

Authors: Wesley E. Bolch, Natalia Estefania Carrasco-Rojas, Chansoo Choi, Robert Joseph Dawson, Aitor Gallastegui Menoyo, Rowan James Milner, Bangho Shin, Maria M. Von Chamier

Affiliation: University of Florida

Abstract Preview: Purpose: To develop a tetrahedralizable mesh-type phantom of a male beagle dog to later perform Monte Carlo radiation transport simulations and calculate organ doses using monoenergetic photons, elect...

A Comparative Analysis of Hand Calculations and Macro Monte Carlo Simulations for Electron Beam Dosimetry

Authors: Mohamed Eldib, Adam Mahl, Moyed Miften, Rachel Petragallo, Kelly L. Stuhr

Affiliation: University of Colorado - Anschutz Medical Campus, University of Colorado School of Medicine, University of Colorado Denver, Department of Radiation Oncology, University of Colorado

Abstract Preview: Purpose: To compare electron beam dose calculations performed manually with those computed using the Macro Monte Carlo simulation for standard fields on both phantom and patient setups, with the aim o...

A Practical Experimental Software Validation Method for Voxel-Based Personalised Dosimetry in Radiopharmaceutical Therapy

Authors: Thomas Gee, Sofia Michopoulou, Amit Nautiyal

Affiliation: University Hospital Southampton

Abstract Preview: Purpose: Dosimetry software that is accessible to departments offers new opportunities to improve patient-specific dosimetry. Prior to clinical decision-making, it is essential to validate dosimetry s...

A Refined Model of Reference Mesh-Type Female Breast Model Vasculature and Glandular Structures for Internal Circulating Lymphocyte Dosimetry

Authors: Wesley E. Bolch, Carlos G. Colon-Ortiz, Robert Joseph Dawson, Lazaro Fuentes Alfonso, Shreya P. Pathak, Julia D. Withrow

Affiliation: University of Florida

Abstract Preview: Purpose: To develop tetrahedral mesh-based tissue models within the breasts of the International Commission on Radiological Protection (ICRP) adult female mesh-type reference computational phantom (AF...

Advancing Flash Radiotherapy: Intercomparison of Parameters between Two Institutions to Optimize Clinical Applications.

Authors: Amir Abdollahi, Celine Karle, Michele M. Kim, Constantinos Koumenis, Andrea Mairani, Erato Stylianou Markidou

Affiliation: Heidelberg Ion-Beam Therapy Center - Department of Radiation Oncology, German Cancer Research Centre(DKFZ), University of Pennsylvania, Physics Dep. University of Cyprus

Abstract Preview: Purpose: The aim is to compare FLASH dose-rate RT generated with protons and carbon (HIT) and compare to protons (UPenn) to provide evidence for equipotency of FLASH vs. standard RT to tumor growth co...

An Efficient Workflow for X-Ray Imaging-Based IGRT/ART

Authors: Lili Chen, Ahmed A. Eldib, Chang Ming Charlie Ma

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Specialized adaptive radiotherapy (ART) systems have been developed and clinically implemented, which are either cost-ineffective such as MR-linacs or inflexible in workflow such as the Ethos...

An Experimentally Derived Microscale Blood and Lymphatic Vasculature Model for Applications to Radiopharmaceutical Dosimetry

Authors: Peter Balogh, Wesley E. Bolch, Mir Md Nasim Hossain, Nien-Wen Hu, Walter Murfee, Wyatt Smither, Julia D. Withrow

Affiliation: New Jersey Institute of Technology, University of Florida

Abstract Preview: Purpose: To develop 3D computational, tissue-representative models incorporating physiologically relevant microvascular network patterns for calculating local alpha particle and electron dosimetry eff...

An International Survey of High Dose Rate Brachytherapy Dosimetry Practices

Authors: Anna Becker, Tomislav Bokulic, Mauro Carrara, Krzysztof Chelminski, Larry A. DeWerd, Alexis Dimitriadis, Benjamin Kellogg, Malcolm R. McEwen, Zakithi L.M Msimang, Mark J. Rivard, Thorsten Sander, Thorsten Schneider, Jamema Swamidas, Egor Titovich, Paula Toroi, Carlos E. de Almeida, Jacco de Pooter, Liset de la Fuente Rosales, Deborah G. van der Merwe

Affiliation: Radiation and Nuclear Safety Authority, University of Zagreb, National Physical Laboratory, IAEA, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Rio de Janeiro State University, Dosimetry Laboratory, Dosimetry and Medical Radiation Physics Section, Division of Human Health, International Atomic Energy Agency, Physikalisch-Technische Bundesanstalt, National Metrology Institute, University of the Witwatersrand, Dosimetry and Medical Radiation Physics Section, Division of Human Health, International Atomic Energy Agency, National Research Council, Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: The recently published IAEA-TRS-492 international code of practice (CoP) aims at improving traceability, accuracy, and consistency in Brachytherapy Dosimetry. To assess current approaches to ...

Backscattering of Compton Cameras: A Monte Carlo Simulation Approach

Authors: Jorge Naoki Dominguez Kondo, Qihui Lyu

Affiliation: University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
Targeted alpha therapy (TAT) has emerged as a highly potent therapeutic method in oncology, but its development is limited by the lack of imaging methods to quantify its dosimetry. Convent...

Backward Photon Monte Carlo Propagator (BPMCP): Proof of Concept of a Fully Physics-Driven SPECT Reconstruction

Authors: Alejandro Bertolet, Carlos Huesa-Berral, Victor V. Onecha

Affiliation: Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: Radioembolization for liver tumors using 90Y microspheres uses SPECT as confirmatory dosimetry, although 90Y is a pure ÎČ-emitter, and SPECT-imaging is only available through subsequent bremss...

Characterization of Commercially-Available Dosimeters and Prototype Diamond Detectors for Absolute Flash Dosimetry of Small-Field Pulsed Proton Beams

Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang

Affiliation: 4Physikalisch-Technische WerkstÀtten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...

Characterization of HCC Tumor Response in 90Y-Radioembolization Clinical Trial RAPY90D Using Prospective Voxel Dosimetry

Authors: E Courtney Henry, Srinivas Cheenu Kappadath, Armeen Mahvash

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Characterization of hepatocellular carcinoma (HCC) tumor responses for single-arm single-center prospective 90Y-radioembolization clinical trial (n=40) that used patient-specific voxel-dos...

Characterization of Image Intensified Cherenkov Cameras for Development of Direct CMOS-Based Detection Systems

Authors: Petr Bruza, Eric R. Fossum, Alexander Geiersbach, David J. Gladstone, Karthik Raj Venkatesan

Affiliation: Dartmouth College, Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: Current Cherenkov imaging sensors rely on image intensifiers to generate sufficient signal for photon detection. While image intensifiers (IIs) exhibit good Cherenkov photon signal response, ...

Characterization of Novel Shielded and Unshielded Silicon Diode Detectors for Photon and Electron Dosimetry in Radiation Therapy

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum fĂŒr Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize the performance of novel shielded and unshielded silicon diode detectors in relative photon and electron beam dosimetry.

Methods: The novel shielded and unshielded sili...

Characterization, Commissioning, and Clinical Evaluation of a Commercial Beo Optically Stimulated Luminescence (OSL) System

Authors: Brett G Erickson, Joseph P. Kowalski, Xinyi Li, Qiuwen Wu, Sua Yoo

Affiliation: Duke University, Mayo Clinic - Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: Characterization and commissioning of the BeO-based myOSLchip system was performed (per TG191) to assess its feasibility as a full replacement for the recalled Landauer aluminum oxide OSL in ...

Characterizing Image Quality and Radiation Dose in Fluoroscopy Systems

Authors: Kainoa Calistro-Allen, Brendon J. Villegas

Affiliation: University of Alabama Birmingham

Abstract Preview: Purpose:
To compare differences in radiation output and image quality in clinical esophagrams across fluoroscope vendors in use at University of Alabama Birmingham, prompted by reports that a newly...

Characterizing an Osld Dosimetry System for Use in a Multi-Clinic Environment

Authors: Amar K. Basavatia, Lee C. Goddard, Rachel Grimm, Wolfgang A. Tomé

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: To characterize the “MyOSL Chip” OSLD system for clinical use and compare the response of multiple readers to allow for utilization in a multi-clinic environment.
Methods: Dose calibration...

Commissioning Radcalc v7.3 with a Collapsed Cone Calculation Algorithm for 6X FFF and 10X FFF Energies

Authors: Maria Jose Almada, Carlos Bohorquez, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger

Affiliation: LAP, Instituto Zunino - Fundacion Marie Curie

Abstract Preview: Purpose:
PSQA is crucial in maintaining patient safety, typically depending on dosimetric measurements. However, advancements in computational technology have highlighted the growing significance o...

Comparison of Multispectral Singlet Oxygen Luminescent Dosimetry (MSOLD) and Singlet Oxygen Explicit Dosimetry (SOED) in BPD-Mediated PDT for Mice

Authors: Robert H Hadfield, Madelyn Johnson, Baozhu Lu, Hongjing Sun, Vikas Vikas, Brian C. Wilson, Weibing Yang, Timothy C. Zhu

Affiliation: University of Glasgow, University of Toronto, University of Pennsylvania

Abstract Preview: Purpose:
Multispectral Singlet Oxygen Luminescent Dosimetry (MSOLD) has been developed as a real-time in vivo dosimetry technique for Photodynamic Therapy (PDT). This study investigates the feasibi...

Comparison of Portal Dosimetry and Delta4Âź for Pretreatment QA of Sfrt-VMAT Plans

Authors: Tianyuan Dai, Zejun Jiang, Xiangyue Kong

Affiliation: Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences

Abstract Preview: Purpose:
This study aims to evaluate the reliability of SFRT-VMAT plan verification by comparing two QA methods: Portal Dosimetry (PD) and Delta4Âź.
Methods:
Preteatment QA was conducted for 1...

Comprehensive Study of Recombination and Polarity Factors across CC04, CC13, FC65P, FC65G, Razor, and PP05 Chambers

Authors: Ziyad ABUBAKR ALHAREESHi, Ibtihaj Yussef Alhodire, Najla Sobhi Bin Shehima, Aram Mufteh A Genaw

Affiliation: Tripoli university hospital

Abstract Preview: Purpose:
This research investigates the recombination and polarity correcting factors for CC04, CC13, FC65P, FC65G, Razor, and PP05 ionization chambers to improve radiation dosimetry accuracy. Unde...

Computed Tomography Organ Dose Library Derived from Newly Developed Newborn-Infant-Toddler Computational Phantoms

Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Adam Leon Kesner, Cameron B. Kofler, Juan Camilo Ocampo Ramos, Yitian Wang, Stefan Wehmeier

Affiliation: University of Chicago, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson

Abstract Preview: Purpose: To develop a slice-specific computed tomography (CT) organ dose library using Monte Carlo radiation transport simulations on a newly created set of newborn, infant, and toddler computational ...

Correction Factors for Estimating Skin Dose from Overresponse of Two Commercial Optically Stimulated Luminescence Dosimeters

Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, HO Lee, Kwangwoo Park, Ye-In Park, Junyoung Son

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yongin Severance Hospital, Yonsei University College of Medicine

Abstract Preview: Purpose: Overresponse in surface in-vivo dosimetry using optically stimulated luminescence dosimeter (OSLD) depends on the beam incidence angle. This study aimed to investigate correction factors to d...

Development and Validation of a Principal Component Analysis Statistical Shape Pediatric/Adolescent Breast Model for Pre-CT Era Breast Dose Reconstruction in Late Effect Studies of Female Childhood Cancer Survivors

Authors: Gregory T. Armstrong, James E. Bates, Kristy K. Brock, Laurence Edward Court, Matt Ehrhardt, Danielle Friedman, Aashish C. Gupta, Donald Hancock, Rebecca M. Howell, Cindy Im, Tera S Jones, Choonsik Lee, Wendy Leisenring, Taylor Meyers, Lindsay Morton, Chaya Moskowitz, Joe Neglia, Vikki Nolan, Caleb O'Connor, Kevin C. Oeffinger, Constance A. Owens, Arnold C. Paulino, Chelsea C. Pinnix, Sander Roberti, Cecile Ronckers, Susan A. Smith, Kumar Srivastava, Lucie Turcotte

Affiliation: Department of Medicine, Duke University School of Medicine, Department of Epidemiology and Cancer Control, St. Jude Children’s Research Hospital, The University of Texas MD Anderson Cancer Center, Department of Oncology, St. Jude Children’s Research Hospital, Department of Pediatrics, Memorial Sloan Kettering Cancer Center, Division of Pediatric Epidemiology and Clinical Research, University of Minnesota, Division of Childhood Cancer Epidemiology, University Medicine at Johannes Gutenberg University Mainz, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Pediatrics, University of Minnesota, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Department of Biostatistics, St. Jude Children’s Research Hospital, Clinical Research Division, Fred Hutchinson Cancer Center, Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Department of Epidemiology and Biostatistics, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University, The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences

Abstract Preview: Purpose: To (1) develop and validate a novel anatomically realistic pediatric/adolescent population-based breast model, (2) incorporate model into an age-scalable female reference phantom, and (3) dem...

Development of Preclinical Multiscale Dosimetry for Beta-Particle Emitting Radionuclide in Radiopharmaceutical Therapy

Authors: Adedamola Adeniyi, Bryan Bednarz, Malick Bio Idrissou, Reinier Hernandez, Ohyun Kwon, Brian W. Miller, Zachary S Morris, Maya Takashima, Jamey Weichert

Affiliation: Departments of Radiation Oncology and Medical Imaging, University of Arizona, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin–Madison, Department of Radiology, School of Medicine and Public Health, University of Wisconsin–Madison, Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin–Madison

Abstract Preview: Purpose: As radiopharmaceutical therapy (RPT) becomes more prevalent in clinical applications, understanding dose-response relationships in the tumor microenvironment (TME) and normal tissues is essen...

Direct in-Vivo Real-Time Singlet Oxygen Detection in Photofrin-Mediated Photodynamic Therapy (PDT) Using Multispectral Singlet Oxygen Dosimetry (MSOLD)

Authors: Theresa Busch, Robert H Hadfield, Madelyn Johnson, Baozhu Lu, Hongjing Sun, Brian C. Wilson, Weibing Yang, Timothy C. Zhu

Affiliation: University of Glasgow, University of Toronto, University of Pennsylvania

Abstract Preview: Purpose: Direct detection of singlet-state oxygen (ÂčO₂) is crucial for advancing type II photodynamic therapy (PDT), but its short lifetime makes in vivo measurement highly challenging. Although Photo...

Dosimetric Evaluation of Comprehensive Motion Management in 1.5T MR-Linac for Real-Time Gated Radiotherapy

Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wah Kong, Ka Ki Lau, Pei-Xiong Li, Pak Hang Nam, Mei Yan Tse, Jierong Wang, Bin Yang, Siu Ki Yu, Jing Yuan, Chi To Yung, Shang Peng Felix Yung

Affiliation: Medical Physics Department, Hong Kong Sanatorium and Hospital, Research Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: Intrafraction motion management remains a major challenge in magnetic resonance-guided radiotherapy (MRgRT). The recent clinical release of an active motion management system aims to enhance ...

Dosimetry Commissioning of a Commercial Cabinet X-Ray Irradiator for Small Animal Irradiation

Authors: Sang Hyun Cho, Amrit Kaphle, Sunil Krishnan, Neerajan Nepal

Affiliation: The University of Texas MD Anderson Cancer Center, The University of Texas Health Science Center

Abstract Preview: Purpose: To determine the basic dosimetry parameters and characteristics of a commercial cabinet x-ray unit for small animal irradiation as well as the specific dosimetry parameters for concurrent irr...

Dosimetry Impact of Beam Flatness on a Clinical Synchrocyclotron Proton System

Authors: Winter Green, Yao Hao, Nels C. Knutson, Matthew C. Schmidt, Xiandong Zhao

Affiliation: Washington University School of Medicine in St. Louis, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine, WashU Medicine

Abstract Preview: Purpose: Beam profile flatness is crucial for both photon and proton radiotherapy systems. This work investigated the dosimetry impact of beam flatness on a clinical synchrocyclotron proton system.

Dosimetry Impact of Overlapping Reconstruction of CT Simulation in Stereotactic Radiosurgery Planning

Authors: Matthew Stephen Andriotty, Chi Ma, Xiao Wang, Keying (Karen) Xu, Suhong Yu, Ning J. Yue, Yin Zhang

Affiliation: Brigham and Women's Hospital, Rutgers Cancer Institute of New Jersey

Abstract Preview: Purpose: To evaluate the effects of overlapping CT reconstruction on dosimetry calculation for LINAC-based SRS patients simulated on CT simulators from three different vendors.
Methods: CT simulati...

End-to-End Pre-Planning Needle Trajectory and Dwell Time Optimization for 3D Printable Cervical and Vaginal Templates

Authors: Deidre Batchelar, Michael Kudla, Stephanie Merkl, Tony Teke

Affiliation: BC Cancer - Kelowna

Abstract Preview: Purpose: Preplanning 3D-printed templates for cervical and vaginal brachytherapy is an iterative process, often taking hours to for an individual patient.
This study demonstrates an end-to-end auto...

Evaluating 177Lu-PSMA-I&t Reconstruction Parameter Influences on Image Quality and Quantification

Authors: Martin Auerbach, Jeremie Calais, Johannes Czernin, Magnus Dahlbom, Zachary Ells, Adrien Holzgreve, Koichiro Kimura, Karam Masri, Catherine (Caffi) Meyer, David Sennung

Affiliation: Department of Nuclear Medicine, UCLA, UCLA, University of California, Los Angeles

Abstract Preview: Purpose: Lutetium-177 PSMA SPECT/CT imaging offers the possibility of qualitative image analysis for tumor response assessment and quantitative image analysis for individualized dosimetry. However, th...

Evaluation of Film and 3D Printed Patient-Specific Phantom for Minibeam Radiation Therapy (MBRT) Dosimetry

Authors: Darwin Abraham Garcia, Michael P. Grams, Scott C Lester, Maryam Mashayekhi, Douglas John Moseley, Robert W Mutter, Sean S Park, Chrystian Quintero Mateus

Affiliation: Mayo Clinic - Rochester, Mayo Clinic

Abstract Preview: Purpose: MBRT delivers sub-millimeter wide regions of high “peak” (~10s Gy) and low “valley” (~1 Gy) doses to treat cancer. MBRT commissioning is performed in flat, uniform plastic water. Thus, differ...

Evaluation of the Hyperscint RP-200 Plastic Scintillation Dosimetry System for Reference Dosimetry in Ultra-High Dose Rate Electron Beam Therapy: A Comparative Study

Authors: Julie Colnot, Eric Deutsch, Christelle Huet, Danahé LeBlanc, Pauline Maury, Charlotte Robert, Imane Saïd Mansour, Cathyanne Schott, Francois Therriault-Proulx

Affiliation: INSERM U1030, Gustave Roussy, University Paris-Saclay, LDRI, IRSN, Medscint, THERYQ / INSERM U1030, Gustave Roussy, University Paris-Saclay, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique

Abstract Preview: Purpose: FLASH radiotherapy, using ultra-high dose rates (UHDR, >100 Gy/s), spares healthy tissues while maintaining tumor control compared to conventional radiotherapy (CONV). However, UHDR dosimetry...

Evaluation of the Improvements of a New Leaf Model (Enhanced Leaf Model) for the Halcyon

Authors: Evan Barber, Gloria P. Beyer, Callum Hartley, Jordi Saez, Philip Wheeler

Affiliation: Department of Radiation Oncology, Hospital Clinic de Barcelona, Department of Radiotherapy Physics, Velindre University NHS Trust, Medical Physics Services, LLC

Abstract Preview: Purpose: To evaluate the Enhanced Leaf Model (ELM) in Eclipse v18 to the standard leaf model for the Halcyon multileaf collimator (MLC) using a measurement-based method.
Methods: The Halcyon’s doub...

Feasibility of Producing GRID Therapy Dosimetry Using a Compact Linac Treatment Head with Pencil Beam Scanning

Authors: Yiran Liu, Zhengzheng Liu, Fang-Fang Yin

Affiliation: Duke Kunshan Univeristy, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: To investigate the feasibility of producing high dose rate GRID therapy using a compact linear accelerator (LINAC) treatment head with scanning beam and stationary grid collimator.
Methods...

Impact of Source-to-Imager Distance on Patient-Specific Quality Assurance Using Epid

Authors: Hajee Reyaz Ali Sahib, Sangeeta Hazarika, Muthukumaran Manavalan, Jaswin Raj, Daya Nand Sharma, Seema Sharma, Subramani Vellaiyan

Affiliation: AIIMS NCI Jhajjar, PTW North America Corporation, All India Institute of Medical Sciences

Abstract Preview: Purpose:
Purpose is to investigate the effect of extended source-to-imager distances (SID) on the resolution of VMAT patient-specific quality assurance (PSQA) in portal dosimetry (PD).
Methods:<...

Impact of Time-of-Flight Reconstruction and Motion Correction on PET-Based Dosimetry in 90y Radioembolization for Hepatocellular Carcinoma

Authors: Spencer Behr, Joseph Grudzinski, Youngho Seo, Jaehoon Shin, Yiran Wang, Frederick J. Wilson

Affiliation: University of California San Francisco, University of California, San Francisco, Voximetry, Inc., Voximetry, Inc

Abstract Preview: Purpose: Voxel-level imaging-based dosimetry enables a significant improvement in accurate and personalized treatment planning in radiopharmaceutical therapy, potentially leading to optimized disease ...

Investigating the Flash Effect: Uncovering Brain Sparing and Cognitive Preservation across Varying Dose Rates in Whole-Brain Irradiation of in-Vivo Mouse Models

Authors: Denise Dunn, Scott R. Floyd, Tyler V. Kay, Anna Lynnette-Price, Eric L. Martin, Stepan Mikhailov, Taylor Nguyen, Mark Oldham, Victoria J. P. Radosova, Zachary J. Reitman, Ramona Rodriguiz, Andrew Thompson, William Wetsel, Seth Wilcox, Ying Wu

Affiliation: Duke University Mouse Behavior Core, Department of Physics, Duke University, Medical Physics Graduate Program, Duke University, Duke University Medical Physics Program, Duke University, Duke University Mouse Behavioral and Neuroendocrine Analysis Core Facility, Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: FLASH radiation therapy (RT) shows promise for reducing normal tissue damage, though its mechanisms remain unclear. Using an in-vivo model with the High Intensity Gamma-ray Source (HIGS) lina...

Investigating the Radiation Chemistry of Flash Radiation Therapy through Electron Paramagnetic (EPR) Spectroscopy

Authors: Ramin Abolfath, Alexander Baikalov, Stefan Bartzsch, Nolan M. Esplen, Alan Eduardo Lopez Hernandez, Emil Schueler

Affiliation: MD Anderson Cancer Center, PI Experimental Medical Physics, Institute of Radiation Medicine (IRM), Helmholtz Munich, Germany, Howard University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: FLASH radiation therapy (FLASH-RT) leverages ultra-high dose rates (UHDR) to spare normal tissue as compared to conventional (CONV)-RT while preserving tumor control; this is termed the FLASH...

Investigation of Triggered Imaging and Auto Beam Hold Using a Dynamic Thorax Phantom for Intra-Fraction Motion Management

Authors: Liu Hong, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose: During treatment delivery on TrueBeam platform 2.7, Triggered Imaging (TI) enables kV images acquisition at regular intervals and Auto Beam Hold (ABH) provides beam pausing if the target is m...

Knowledge-Based Planning for Chest Wall with Lymph Nodes Irradiation VMAT

Authors: Nesrin Dogan, Panagiota Galanakou, Robert Kaderka

Affiliation: University of Miami, Sylvester Comprehensive Cancer Center, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose:
To develop knowledge-based treatment planning (KBP) for volumetric modulated arc therapy (VMAT) in chest wall treatments with regional nodal involvement. Given the challenges posed due to ...

Log File-Based Patient-Specific QA As a Viable Alternative to Measurement-Based QA in IMPT

Authors: Sina Mossahebi, Pouya Sabouri, Kayla Schneider, James W Snider

Affiliation: University of Maryland School of Medicine, Proton International, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences

Abstract Preview: Purpose:
Conventional patient-specific QA (PSQA) for intensity-modulated proton therapy (IMPT) requires extensive measurements, straining resources in single-room proton centers. This study evaluat...

Lung Mass Variability in Clinical Chest CT Imaging with Automatic Contouring Tool

Authors: Yasaman Anbari, Srinivas Cheenu Kappadath, Benjamin P. Lopez

Affiliation: University of Houston, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To improve lung dosimetry for 90Y-radioembolization planning, CT-based techniques have been proposed for patient-specific lung mass estimation instead of assuming nominal 1 kg lung masses. He...

Mapping Dosimetry, Excision Probability, and Mpmri Pixel Data to Core-Needle Biopsy Tissue from HDR Prostate Brachytherapy

Authors: Jeffrey Andrews, Nathan E. Becker, Juanita Crook, Andrew Jirasek, Matthew Jonathan Muscat

Affiliation: UBC, BC Cancer Agency, BC Cancer

Abstract Preview: Purpose: To map dosimetry and imaging information to ultrasound and multi-parametric magnetic resonance (mpMR) guided trans-perineal core-needle biopsies, performed during two-fraction prostate high-d...

Modeling Alpha-Particle Dose from Diffusing Alpha-Emitters Radiation Therapy in Tissue with Inhomogeneous Diffusion

Authors: Lior Arazi, Gil'ad N. Cohen, Antonio L. Damato, Irene P. Zhang

Affiliation: Unit of Nuclear Engineering, Faculty of Engineering Sciences, Ben-Gurion University of the Negev, NYU Grossman School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Diffusing alpha-emitters Radiation Therapy (“Alpha DaRT”) is a promising new radiation therapy modality for treating bulky tumors. The dose delivered by Alpha-DaRT sources is dependent on the...

Modernization of the NIST Air-Kerma Strength Standard for LDR Brachytherapy Seeds

Authors: Michael G. Mitch, Csilla I. Szabo-Foster

Affiliation: National Institute of Standards and Technology

Abstract Preview: Purpose: The U.S. air-kerma strength standard for low-dose-rate (LDR) low-energy photon-emitting brachytherapy sources provides measurement traceability for calibrations at the AAPM Accredited Dosimet...

Monte Carlo Derived Correction Factors for Ion Chambers Used in the Calibration of Gamma Knife Perfexion Model: Impact of Phantom Materials and Chamber Orientation on Dosimetric Accuracy

Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: Commissioning of a Gamma KnifeÂź (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...

Monte Carlo Evaluation of Water-Equivalent Materials for Nanowire-Based Oslds in Flash Radiotherapy

Authors: James Chun Lam Chow, Harry E Ruda

Affiliation: University of Toronto, Princess Margaret Cancer Centre

Abstract Preview: Purpose: FLASH radiotherapy (FLASH-RT) with dose rate greater than 40 Gy/s, has demonstrated potential in reducing normal tissue toxicity while maintaining tumor control. However, accurate and reliabl...

On Estimating Effective Doses Associated with Different Imaging Protocols for Weight-Bearing Imaging of the Hip with a Dedicated Cone Beam CT (CBCT) Scanner

Authors: Jeff Boob, Jaydev K. Dave, Tim Minch, Bhavyata Tanna

Affiliation: Dr. Ronald E. McNair Academic High School, Mayo Clinic, CurveBeam AI

Abstract Preview: Purpose: To estimate effective doses associated with different imaging protocols for hip imaging with a cone beam CT (CBCT) scanner specifically designed for weight-bearing acquisitions.
Methods: A...

Optimal Choice of Companion Radiotracer for TAT 225Ac-Mti-201.

Authors: Vinay K Banka, Mikalai Budzevich, William R. Gibbons, Mark L. McLaughlin, Jacob Moriarty, Eduardo G. Moros, David L. Morse, Christopher J. Tichacek, Thad J. Wadas

Affiliation: Modulation Therapeutics Inc, Moffitt Cancer Center, University of Iowa

Abstract Preview: Purpose: A targeted alpha therapy drug, 225Ac-MTI-201, has been developed targeting the Melanocortin 1 Receptor for metastatic uveal melanoma and is currently in FIH clinical trials. Since alpha emiss...

Optimizing Dosimetry in Rpt Clinics: Tackling Initial Hurdles and Ensuring Image Accuracy.

Authors: Siju C. George, Alonso N. Gutierrez, Vivek Mishra, Ranjini P. Tolakanahalli

Affiliation: Miami Cancer Institute, Baptist Health South Florida, Miami Cancer Institute

Abstract Preview: Purpose: This presentation focuses on optimizing dosimetry in RPT clinics by tackling initial setup challenges and ensuring the accuracy of SPECT/CT imaging for dosimetry. It will address the qualific...

Parameterized Dosimetric Models of the Lumbar Vertebrae for Patient-Informed Active Marrow Dosimetry in Radiopharmaceutical Therapy

Authors: Wesley E. Bolch, Chansoo Choi, Robert Joseph Dawson, Michael Lassmann, Maikol Salas-Ramirez, Bangho Shin, Johannes Tran-Gia, Yitian Wang

Affiliation: Department of Nuclear Medicine, University Hospital WĂŒrzburg, University of Florida

Abstract Preview: Purpose: Conduct a parameterized library of mesh-type skeletal models across the lumbar vertebrae. In radiopharmaceutical dosimetry, the hematopoietic active bone marrow is typically a dose-limiting n...

Patient Dosimetry in Medical Imaging and Radiotherapy: A New Course for Medical Physics Students

Authors: Wesley E. Bolch, Robert Joseph Dawson, Wyatt Smither

Affiliation: University of Florida

Abstract Preview: Purpose: To design a novel course that reinforces key medical physics concepts through a series of practicum sessions, where students learn and apply the Monte Carlo radiation transport code, PHITS, c...

Patient-Specific Quality Assurance in SBRT Treatments Using 3D Polymer Gel Dosimetry

Authors: Esteban Arzaga-Barajas, Paola Jazmin Guadarrama Huerta, Jose Alejandro Jimenez, Guerda Massillon-JL, Maria Adela Poitevin-ChacĂłn, Alejandro Rodriguez-Laguna

Affiliation: UNAM, Medica Sur

Abstract Preview: Purpose: To perform patient-specific quality assurance (PSQA) tests for four SBRT treatments of patients diagnosed with vertebral, ilium, pelvic lymph node and lung tumors.
Methods: MAGIC gel consi...

Performance Evaluation of End-of-Life Epid Panel Utilizing Automated Quality Assurance Test Suite

Authors: Michael Paul Barnes, Lana C. Critchfield, John J. DeMarco, Ellie Durussel, Nilendu Gupta, James Irrer, Peyton Jensen, Grace Gwe-Ya Kim, Cory S. Knill, Seng Boh Gary Lim, Justin K. Mikell, Jean M. Moran, Seyyedeh Azar Oliaei Motlagh, Mario Perez, Michael Pillainayagam, Claire Zhang

Affiliation: University of Michigan, Department of Radiation Oncology, University of Michigan, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Washington University School of Medicine in St. Louis, University of California San Diego, Royal North Shore Hospital, Calvary Mater Hospital Newcastle, Cedars-Sinai Medical Center

Abstract Preview: Purpose: EPIDs are widely used in linac QA due to their efficiency and accuracy. As EPIDs age, performance degradation may occur, potentially compromising reliability of EPID-based automated QA result...

Personalized Dosimetric Workflow for 177Lu-PSMA Treatments Considering the Cross-Irradiation from Bone Metastases to Red Bone Marrow

Authors: NadÚge Anizan, David Broggio, Désirée Deandreis, Didier Franck, Camilo Garcia, Stéphanie Lamart, Sébastien Leygnac, Alexandre Pignard

Affiliation: Gustave Roussy, Service de Physique Médicale, Institut Bergonié, Service de Physique Médicale, Gustave Roussy, Service de Médecine Nucléaire, Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSE-SANTE/SDOS/LEDI, Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSE-SANTE/SDOS

Abstract Preview: Purpose: This work aimed at developing an innovative workflow for 177Lu-PSMA personalized dosimetry to lesions and organs at risk (OAR) simultaneously, considering the cross-irradiation from bone meta...

Physics-Informed Neural Network for In Vivo Dosimetry during Proton Therapy Using Protoacoustic Tomography

Authors: Kristina Bjegovic, Yong Chen, Gilberto Gonzalez, Yankun Lang, Lei Ren, Leshan Sun, Liangzhong Xiang, Yifei Xu

Affiliation: University of Maryland School of Medicine, University of California, Irvine, University of Oklahoma Health Sciences Center, University of Oklahoma Health Science Center

Abstract Preview: Purpose: Proton therapy is becoming an increasingly popular choice for cancer treatment due to its precision, reduced side effects, and effectiveness. While dosimetry is fundamental to the success of ...

Proton Vs Photon Therapy for Stereotactic Arrhythmia Radioablation of Ventricular Tachycardia

Authors: Chih-Wei Chang, Kristin A Higgins, Xiaojun Jiang, Pretesh Patel, Justin R. Roper, Keyur Shah, Sibo Tian, Zhen Tian, Yinan Wang, Xiaofeng Yang, Jun Zhou

Affiliation: Department of Radiation Oncology, City of Hope Cancer Center Atlanta, Emory University, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Ventricular tachycardia (VT) is a life-threatening arrhythmia commonly treated with catheter ablation; however, some cases remain refractory to conventional treatment. Stereotactic arrhythmia...

Quantifying the Impact of Tissue Inhomogeneities on Calculated Dosimetry within LDR Brachytherapy

Authors: Fatemeh Akbari, Deidre Batchelar, Luc Beaulieu, Nathan E. Becker, Juanita Crook, Dakota Mckeown, Matthew Jonathan Muscat, Rowan M. Thomson

Affiliation: Département de physique, de génie physique et d'optique, Université Laval, BC Cancer Agency, UBC, Carleton University, BC Cancer - Kelowna, BC Cancer

Abstract Preview: Purpose:
To study the effects of inter-seed attenuation and tissue inhomogeneities on dose-volume metrics of critical structures in prostate low-dose-rate (LDR) permanent seed implant brachytherapy...

Radiation Sub-Segmentectomy in 90y Radioembolization: Post-Therapy Dosimetry, Treatment Response, and Pathological Necrosis

Authors: Guilherme Rosa Ferreira, Dan Giardina, John Karageorgiou, Chris Malone, Allan Thomas

Affiliation: Washington University School of Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine

Abstract Preview: Purpose: Radiation segmentectomy has become a primary strategy in 90Y radioembolization, with localized treated volumes that can include up to two liver segments. The goal is complete pathological nec...

Rapid 3D Prototyped Solid-Source Phantoms for Quality Assurance of Biology-Guided Radiotherapy (BgRT)

Authors: Jon Burns, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma

Affiliation: RefleXion Medical

Abstract Preview: Purpose: To simplify BgRT testing we have developed techniques that use 3D resin printed structures that can be filled with Ge-68 epoxy. This approach allows the development of highly complex, clinica...

Real-Time Observation of Radiation-Induced DNA Damage for Radiopharmaceuticals

Authors: Denis Bergeron, Brittany Broder, Sean Jollota, Ahtesham Ullah Khan, Michael Lamontagne, Joseph W. Robertson

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Biophysics and Biomedical Research Group, Microsystems and Nanotechnology Division, National Institute of Standards and Technology, National Institute of Standards and Technology

Abstract Preview: Purpose: We present new methodology for real-time measurement of radiation-induced DNA damage caused by radiopharmaceuticals. Building on previous efforts to measure DNA fragmentation with nanopore se...

Retrospective Evaluation of Combined Photon SBRT and Radium-223 SPECT Based Radiopharmaceutical Therapy Tumor Dosimetry in Clinical Trial Patient Cases

Authors: David P. Adam, Allison Cartee, Eric C. Frey, Michael Ghaly, Bin He, Robert Francois Hobbs, Natalie Rose Kania, Ana Kiess, Ian Marsh, Bonnie N. C. President, Steven Rowe, George Sgouros, Phuoc Tran, Hao Wang

Affiliation: Johns Hopkins University, Radiopharmaceutical Imaging and Dosimetry, LLC (Rapid), 2The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins Medical Institute, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Oncology, Johns Hopkins University, School of Medicine, Department of Radiology, University of North Carolina, Chapel Hill

Abstract Preview: Purpose: Advanced treatment paradigms combining SPECT/CT imageable, alpha emitting, radiopharmaceutical therapy (RPT) and stereotactic body radiotherapy (SBRT) can provide the potential of dose escala...

SPECT/CT Multimodal Segmentation of Bone Marrow for Theranostic Dosimetry

Authors: Tommaso Frigerio, Joshua Genender, John M. Hoffman, Catherine (Caffi) Meyer

Affiliation: UCLA, David Geffen School of Medicine at UCLA

Abstract Preview: Purpose: Accurate bone marrow segmentation is required for bone marrow dosimetry to monitor for dangers in PSMA-Lu177 radioligand therapy. We introduce a hybrid (AI/semantic knowledge) segmentation pi...

Small Fields Output Factor Measurements in 1.5 MR-Linac

Authors: Thomas I. Banks, Tsuicheng D. Chiu, Viktor M. Iakovenko, Christopher Kabat, Chang-Shiun Lin, Mu-Han Lin, Arnold Pompos

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX

Abstract Preview: Purpose: The superior soft-tissue contrast provided by MR imaging offers favorable conditions for the effective application of stereotactic body radiation therapy (SBRT). Accurate small field dosimetr...

Spot Map Modification for Planning Optimization on a Spot Scanning Proton System with Adaptive Aperture

Authors: Austen N. Curcuru, Winter Green, Yao Hao, Jiayi Liu, Yuting Peng, Tiezhi Zhang, Xiandong Zhao

Affiliation: Washington University School of Medicine, Department of Radiation Oncology, WashU Medicine, Virginia Commonwealth University, Washington University School of Medicine, Washington University in St. Louis

Abstract Preview: Purpose: We proposed a treatment planning optimization method that utilizes customized spot map modification to achieve less dosimetry uncertainty, monitor unit ratio (MUR) and neutron dose in a spot ...

Standardized Immobilization and Setup Procedure Improves Accuracy of Multi-Time Point SPECT/CT Image Registration for Radiopharmaceutical Therapy (RPT) Dosimetry

Authors: Bryan Bednarz, Laura Bennett, Abby E. Besemer, Tyler J Bradshaw, Steve Y Cho, John M. Floberg, Joseph Grudzinski, Elissa Khoudary, Michael J. Lawless

Affiliation: Department of Radiology, University of Wisconsin, University of Wisconsin-Madison Department of Medical Physics, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Voximetry, Inc, University of Pennsylvania, Department of Radiology, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: To assess the impact of using a standardized immobilization setup for multi-time-point SPECT/CT imaging on radiopharmaceutical therapy (RPT) dosimetry image registration.

Methods: Ten ...

Streamlined Stereotactic Radiosurgery (SRS) Commissioning Experience with a 6FFF Beam for an Elekta Versa: A Clinical Overview for Increased Precision.

Authors: Asma Amjad, Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Accurate and precise linac-based SRS commissioning can be very challenging. Thus, it is important to increase the confidence in the measurement at each step prior to end-to-end testing. The p...

The Development of Large Field MR Guided Radiotherapy for Pelvic Lymph Node SBRT and Its Dosimetry Improvement

Authors: David Byun, Ting Chen, Paulina E. Galavis, Allison McCarthy, Hesheng Wang, Michael J Zelefsky

Affiliation: NYU Langone Health

Abstract Preview: Purpose: To summarize a MR guided adaptive workflow developed for pelvic lymph nodes (PLN) stereotactic radiotherapy using large field size on Elekta Unity© MR Linac system, and to quantitatively anal...

The Impact of Intempo Imaging on Cyberknife Prostate Plans

Authors: Lei Fu, Eric Gressen, Yingcui Jia, Shari Rudoler, Yevgeniy Vinogradskiy, Qianyi Xu

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: InTempo imaging in the Accuray CyberKnife System improves the ability to track/correct target motion during treatment. However, no studies have provided information on the impact of InTempo I...

Total Body Irradiation Using Field-in-Field Treatment Planning Techniques

Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West

Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma

Abstract Preview: Purpose: To simulate total-body-irradiation (TBI) with field-in-field treatment planning techniques and test portal dosimetry for dose verification and quality assurance.
Methods: CT images of full...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...

Validation of SRS Mapcheck for Patient-Specific Quality Assurance of Cyberknife

Authors: Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, Tae Ho Kim, Sangmin Lee

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: The CyberKnife system, designed for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT), considers SRS MapCHECK an effective tool for patient-specific QA (PSQA). This wo...

Variance and Estimation of Patient Specific S-Values for I-131 Administration.

Authors: Jae Won Jung, Choonsik Lee, Jason C. Mace, Sergio Morato Rafet

Affiliation: East Carolina University, Carilion Clinic, National Cancer Institute

Abstract Preview: Purpose: Dosimetry for radionuclides used in nuclear medicine can be accurately calculated if sufficient data is available. However, in most cases crucial information cannot or will not be known a pri...