Search Submissions 🔎

Results for "dosimetry vmat": 22 found

0.23T/1.5T MRI Imaging for Spine with Instrumentations

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
MRI images with minimal artefacts to scan spine with Titanium instrumentation (screws, stabilizing rods, and spacer) are acquired by optimizing scanning parameters of pulse sequences (main...

A 3D Printed Ion Chamber Insert Solution for Absolute Dosimetry with Varying Ionisation Chambers in Radiosurgery.

Authors: Shashanksharad Kale, Gopishankar Natanasabapathi, Daya Nand Kishore Sharma

Affiliation: All India Institute of Medical Sciences (AIIMS), Department of Radiation Oncology, All India Institute of Medical Sciences

Abstract Preview: Purpose:
The study demonstrates a novel 3D printing method to fabricate an ion chamber insert (ICI) for absolute dosimetry purpose in gamma knife radiosurgery (GKRS).
Methods:
Our institute u...

An Ultra-High Parallel Performance (UHPP) Framework for Highly Complex Radiotherapy Planning

Authors: Lu Jiang, Shusen Jing, Qihui Lyu, Dan Ruan, Ke Sheng, Qifan Xu

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California San Francisco, Department of Radiation Oncology, University of California at San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose: In radiotherapy, the conformity and compactness of dose distribution are vital to patient outcomes. The introduction of highly complex planning, such as 4π radiotherapy, has provided a system...

Checking of Sensitivity of Volumetric Modulated Arc Therapy Quality Assurance System with a Cavity Generation Method

Authors: Kaile Li, Esmail Parsai

Affiliation: Alexander T. Augusta Military Medical Center, Alexander T. Augusta Miliary Medical Center

Abstract Preview: Purpose: To evaluate the sensitivity of the portal dosimetry system with the Arc CHECK system at identical Volumetric Modulated Arc Therapy (VMAT) setup
Methods: An Arc CHECK system from Sun Nuclea...

Commissioning a Comprehensive Workflow for VMAT Total Body Irradiation (TBI) Using Publicly and Commercially Available Resources

Authors: Alan H. Baydush, Sarah Cummings, Jeffrey Michael Fenoli, Christy Hickerson, Lalith Kumaraswamy, Philmo Oh, Sarah B. Wisnoskie

Affiliation: Novant Health Cancer Institute, Novant Health

Abstract Preview: Purpose: To develop, validate, and commission a VMAT Total Body Irradiation (TBI) workflow by integrating publicly available resources, commercial solutions, and in-house testing to enhance treatment ...

Comparison of Portal Dosimetry and Delta4® for Pretreatment QA of Sfrt-VMAT Plans

Authors: Tianyuan Dai, Zejun Jiang, Xiangyue Kong

Affiliation: Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences

Abstract Preview: Purpose:
This study aims to evaluate the reliability of SFRT-VMAT plan verification by comparing two QA methods: Portal Dosimetry (PD) and Delta4®.
Methods:
Preteatment QA was conducted for 1...

Deeptuning: A Deep Learning Dose Prediction Framework for Interactive Plan Tuning

Authors: Mingli Chen, Huan Amanda Liu, Weiguo Lu, Lin Ma

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Mayo Clinic

Abstract Preview: Purpose: To reduce the back-and-forth in planning process between physicians and dosimetrists resulting from trade-off exploration, we proposed a novel deep learning framework called DeepTuning.
Me...

Dosimetric Evaluation of Enhanced Dynamic Leaf Gap Modeling in Small-Field Clinical Plans: A Verification Study

Authors: Ian J. Butterwick, Sumudu Katugampola, ChangSeon Kim, Evan G. Meekins, Zhengdong Zhang

Affiliation: Mount Sinai Beth Israel, Gesinger Medical Center, Geisinger Medical Center

Abstract Preview: Purpose: To evaluate the dosimetric impact of enhanced dynamic leaf gap (EDLG) modeling in Eclipse V18.0 on small-field dosimetry within VMAT plans.
Methods: Plans with small fields (1 cm x 1 cm to...

Four-Dimensional Computed Tomography Based on 16cm-Long Detectors Vs 4cm-Long Detectors: Dose Validation

Authors: Qianyi Xu, Inhwan Yeo

Affiliation: INOVA Schar Cancer Institute, Thomas Jefferson University

Abstract Preview: Purpose:
Four-dimensional computed tomography(4DCT) is prone to a geometrical error when respiration changes upon patient shift. 4DCT with a longer-length detector(16cm), uninvolving the shift, has...

High-Fidelity Treatment Optimization for Online Adaptive Stereotactic Partial Breast Irradiation: Integrating Dose and Treatment Time Considerations

Authors: Drexell Hunter Boggs, Carlos E. Cardenas, Jingwei Duan, Joseph Harms, Joel A. Pogue, Richard A. Popple, Courtney Bosse Stanley, Dennis N. Stanley, Sean Xavier Sullivan, Natalie N. Viscariello

Affiliation: Washington University in St. Louis, The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: CBCT-guided online adaptive radiation therapy (OART) with Ethos for stereotactic accelerated partial breast irradiation (APBI) can mitigate inter-fraction variation, leading to dosimetric adv...

Impact of Mlc and Collimator Errors in Psqa Techniques for VMAT Breast Treatment Plans

Authors: Maria Jose Almada, Oscar Apaza, Carlos Bohorquez, Ezequiel Cabrera, Rogelio Diaz Moreno, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger

Affiliation: LAP, FaMAF, UNC, Instituto Zunino - Fundacion Marie Curie

Abstract Preview: Purpose:
PSQA employs gamma analysis to verify the planned versus delivered dose. Evaluating the effectiveness of PSQA techniques in identifying errors is crucial. This study aims to incorporate ML...

Impact of Source-to-Imager Distance on Patient-Specific Quality Assurance Using Epid

Authors: Hajee Reyaz Ali Sahib, Sangeeta Hazarika, Muthukumaran Manavalan, Jaswin Raj, Daya Nand Sharma, Seema Sharma, Subramani Vellaiyan

Affiliation: AIIMS NCI Jhajjar, PTW North America Corporation, All India Institute of Medical Sciences

Abstract Preview: Purpose:
Purpose is to investigate the effect of extended source-to-imager distances (SID) on the resolution of VMAT patient-specific quality assurance (PSQA) in portal dosimetry (PD).
Methods:<...

Influence of Intrafraction Motion on the Dosimetry of Prostate Treatments

Authors: María Fernández, Inés Flores, Nuria Montero, Manuel Ruiz, Francisco San Miguel

Affiliation: Hospital Central de la Defensa 'Gómez Ulla', Hospital Central de la Defensa "Gomez Ulla", CSVE, Hospital Central de la Defensa 'Gómez Ulla', CSVE

Abstract Preview: Purpose:
During external radiotherapy treatments in the prostate, there can be PTV movements between fractions and during each treatment fraction. In a typical prostate treatment in our institution...

Investigation of Triggered Imaging and Auto Beam Hold Using a Dynamic Thorax Phantom for Intra-Fraction Motion Management

Authors: Liu Hong, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose: During treatment delivery on TrueBeam platform 2.7, Triggered Imaging (TI) enables kV images acquisition at regular intervals and Auto Beam Hold (ABH) provides beam pausing if the target is m...

Knowledge-Based Planning for Chest Wall with Lymph Nodes Irradiation VMAT

Authors: Nesrin Dogan, Panagiota Galanakou, Robert Kaderka

Affiliation: University of Miami, Sylvester Comprehensive Cancer Center, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose:
To develop knowledge-based treatment planning (KBP) for volumetric modulated arc therapy (VMAT) in chest wall treatments with regional nodal involvement. Given the challenges posed due to ...

Planning and Delivering Homogenous Dose to Craniospinal Irradiation on Linear Accelerator

Authors: Issra Rashed, Jennie Wilder, Jingeng Zhu

Affiliation: Rush Riverside Cancer Institute, Advanced Oncology Solutions (AOS) Varian, a Siemens Healthineers company

Abstract Preview: Purpose: Develop a method to plan and deliver homogeneous dose to Craniospinal(CS) irradiation on Linear Accelerator.
Methods: Three treatment planning volumes (PTV) are created in sequence from su...

Relative Optimized Linearization for Film Dosimetry with Non-Uniformity Correction

Authors: Piotr Pater, Nicholas G. Zacharopoulos

Affiliation: McGill University, Medical Physics Unit, Gerald Bronfman Department of Oncology, McGill University

Abstract Preview: Purpose: To develop a method for accurate relative film dosimetry that incorporates non-uniformity
corrections.
Methods: The accuracy of Devic’s [1] linearization approach was evaluated using si...

Stereotactic Body Radiosurgery for Refractory Ventricular Tachycardia: Presenting Efficient Clinic Workflow, Dosimetric Analysis and Patients Reported Clinical Results

Authors: Karam Ayoub, Aaron B Hesselson, Ronald C McGarry, Joshua Misa, Damodar Pokhrel

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Cardiology

Abstract Preview: Purpose: Noninvasive stereotactic body radiosurgery (SBRS) is emerging treatment option for advanced heart failure patients with refractory-ventricular tachycardia (rVT) who experienced recurrent impl...

The Impact of Implant Position and Different Radiotherapy Techniques on Dosimetry in Post-Mastectomy Breast Reconstruction for Breast Cancer

Authors: Xiu tong Lin

Affiliation: Department of Radiation physics and technology, Shandong Second Provincial General Hospital

Abstract Preview: Purpose: To compare the dosimetric differences between the photon and proton plans and between the different target according to the placement of the implants for patients undergoing radiotherapy afte...

Total Body Irradiation Using Field-in-Field Treatment Planning Techniques

Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West

Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma

Abstract Preview: Purpose: To simulate total-body-irradiation (TBI) with field-in-field treatment planning techniques and test portal dosimetry for dose verification and quality assurance.
Methods: CT images of full...

Treatment Machine Matching for ELM in Eclipse v18.0 By Adjusting Physical Leaf Gap

Authors: Quyen Duong, Si Young Jang, Soyoung Lee, Samuel Ming Ho Luk

Affiliation: Boston University, Department of Radiation Oncology, University of Vermont Medical Center, Boston Medical Center

Abstract Preview: Purpose: To investigate the clinical impact of physical MLC gaps changes with Millennium 120 MLC on Enhanced Leaf Modeling (ELM) and patient plans, and to establish a new MLC model in Eclipse v18.0 on...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...