Search Submissions 🔎

Results for "electron dosimetry": 41 found

3D Renal Microdosimetry: Evaluating Radiopharmaceuticals Using Histology-Based 3D Models

Authors: John P. Aris, Wesley E. Bolch, Madison Bushloper, Lauren E Ellis, Adam Grey Haneberg, Elizabeth Martin, Bonnie N. C. President, Andrew Robert Sforza, Alexander Zorrilla

Affiliation: Johns Hopkins University, Biomedical Engineering, University of Florida

Abstract Preview: Purpose: To develop six additional high-fidelity 3D models of kidney renal cortical labyrinth from H&E-stained histology slides to support radiation dosimetry in radiopharmaceutical therapies (RPTs).<...

A Beagle Dog Mesh-Type Phantom for Application to Nuclear Medicine and Internal Dosimetry

Authors: Wesley E. Bolch, Natalia Estefania Carrasco-Rojas, Chansoo Choi, Robert Joseph Dawson, Aitor Gallastegui Menoyo, Rowan James Milner, Bangho Shin, Maria M. Von Chamier

Affiliation: University of Florida

Abstract Preview: Purpose: To develop a tetrahedralizable mesh-type phantom of a male beagle dog to later perform Monte Carlo radiation transport simulations and calculate organ doses using monoenergetic photons, elect...

A Comparative Analysis of Hand Calculations and Macro Monte Carlo Simulations for Electron Beam Dosimetry

Authors: Mohamed Eldib, Adam Mahl, Moyed Miften, Rachel Petragallo, Kelly L. Stuhr

Affiliation: University of Colorado - Anschutz Medical Campus, University of Colorado School of Medicine, University of Colorado Denver, Department of Radiation Oncology, University of Colorado

Abstract Preview: Purpose: To compare electron beam dose calculations performed manually with those computed using the Macro Monte Carlo simulation for standard fields on both phantom and patient setups, with the aim o...

A Novel Setup for Flash Radiotherapy Beam Delivery at Isocenter Using Downstream Electron Scattering

Authors: Dale W. Litzenberg, Ikechi S Ozoemelam, Rowan Paplanus, Michael Pillainayagam, Donald A. Roberts

Affiliation: University of Michigan, Oregon Health & Science University

Abstract Preview: Purpose: Clinical linear accelerators use dual foil scattering systems designed to achieve large uniform fields (up to 25×25cm²), which can reduce beam fluence by up to 93% compared to the unmodified ...

A Refined Model of Reference Mesh-Type Female Breast Model Vasculature and Glandular Structures for Internal Circulating Lymphocyte Dosimetry

Authors: Wesley E. Bolch, Carlos G. Colon-Ortiz, Robert Joseph Dawson, Lazaro Fuentes Alfonso, Shreya P. Pathak, Julia D. Withrow

Affiliation: University of Florida

Abstract Preview: Purpose: To develop tetrahedral mesh-based tissue models within the breasts of the International Commission on Radiological Protection (ICRP) adult female mesh-type reference computational phantom (AF...

An End-to-End Test for Adaptive Radiotherapy with Varian Hypersight CBCT Imaging System Using Radiochromic Film in a Rando Pelvis Phantom

Authors: Jameson T. Baker, Yijian Cao, Jenghwa Chang, Sean T Grace, Lyu Huang, Jian Liu, Echezona Simon Obi, Anurag Sharma

Affiliation: Northwell, Hofstra University Medical Physics Program

Abstract Preview: Purpose:
To validate the end-to-end dosimetrical accuracy of Varian HyperSight CBCT for adaptive radiotherapy (ART), from simulation to dose delivery, using radiochromic film dosimetry in a Rando p...

An Experimentally Derived Microscale Blood and Lymphatic Vasculature Model for Applications to Radiopharmaceutical Dosimetry

Authors: Peter Balogh, Wesley E. Bolch, Mir Md Nasim Hossain, Nien-Wen Hu, Walter Murfee, Wyatt Smither, Julia D. Withrow

Affiliation: New Jersey Institute of Technology, University of Florida

Abstract Preview: Purpose: To develop 3D computational, tissue-representative models incorporating physiologically relevant microvascular network patterns for calculating local alpha particle and electron dosimetry eff...

Application of a Flashdiamond Detector Coupled to a Beam Current Transformer to Commission a Monte Carlo Model of a Ultra-High Dose Rate Electron Beam

Authors: Javier Chiasson, Dominique Guillet, Arthur Lalonde, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal

Abstract Preview: Purpose:
To validate a Monte Carlo (MC) model of a Ultra-High dose rate (UHDR) electron beam using a prototype flashdiamond (fD) detector coupled to an electrostatically shielded beam current trans...

Assessment of the Radiological Features of 3D-Printed Polylactic Acid Composites for Creating Personalized Dosimetric Phantoms

Authors: Ashish Binjola, Raj Kishore Bisht, Natanasabapathi Gopishankar, Pratik Kumar, Daya Nand Kishore Sharma, Sukhvir Kishore Singh, Subramani Vellaiyan

Affiliation: Medical Physics Unit, All India Institute of Medical Sciences, All India Institute of Medical Sciences, Department of Radiological Safety, Institute of Nuclear Medicine and Allied Sciences, Department of Radiation Oncology, All India Institute of Medical Sciences

Abstract Preview: Purpose: Additive manufacturing is increasingly being explored to create dosimetry phantoms. Commercial anthropomorphic phantoms represent an average patient and lack anatomical variations due to obes...

Calorimetric Measurement of Absorbed Dose By a Flash Beamline

Authors: Luke Connell, Stephen F. Kry, Malcolm R. McEwen, Bryan R. Muir, James Renaud, Emil Schueler, Hayden Scott, Paige A. Taylor

Affiliation: National Research Council, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: To demonstrate the capability of a robust calorimeter to accurately determine the absorbed dose delivered by an electron FLASH beamline.

Methods: Electron FLASH beams of 6 MeV and 9 Me...

Characterization of Image Intensified Cherenkov Cameras for Development of Direct CMOS-Based Detection Systems

Authors: Petr Bruza, Eric R. Fossum, Alexander Geiersbach, David J. Gladstone, Karthik Raj Venkatesan

Affiliation: Dartmouth College, Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: Current Cherenkov imaging sensors rely on image intensifiers to generate sufficient signal for photon detection. While image intensifiers (IIs) exhibit good Cherenkov photon signal response, ...

Characterization of Novel Shielded and Unshielded Silicon Diode Detectors for Photon and Electron Dosimetry in Radiation Therapy

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum für Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize the performance of novel shielded and unshielded silicon diode detectors in relative photon and electron beam dosimetry.

Methods: The novel shielded and unshielded sili...

Characterization, Commissioning, and Clinical Evaluation of a Commercial Beo Optically Stimulated Luminescence (OSL) System

Authors: Brett G Erickson, Joseph P. Kowalski, Xinyi Li, Qiuwen Wu, Sua Yoo

Affiliation: Duke University, Mayo Clinic - Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: Characterization and commissioning of the BeO-based myOSLchip system was performed (per TG191) to assess its feasibility as a full replacement for the recalled Landauer aluminum oxide OSL in ...

Characterizing an Osld Dosimetry System for Use in a Multi-Clinic Environment

Authors: Amar K. Basavatia, Lee C. Goddard, Rachel Grimm, Wolfgang A. Tomé

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: To characterize the “MyOSL Chip” OSLD system for clinical use and compare the response of multiple readers to allow for utilization in a multi-clinic environment.
Methods: Dose calibration...

Commissioning of a Near Real-Time In Vivo Film Dosimetry System

Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...

Comprehensive Study of Recombination and Polarity Factors across CC04, CC13, FC65P, FC65G, Razor, and PP05 Chambers

Authors: Ziyad ABUBAKR ALHAREESHi, Ibtihaj Yussef Alhodire, Najla Sobhi Bin Shehima, Aram Mufteh A Genaw

Affiliation: Tripoli university hospital

Abstract Preview: Purpose:
This research investigates the recombination and polarity correcting factors for CC04, CC13, FC65P, FC65G, Razor, and PP05 ionization chambers to improve radiation dosimetry accuracy. Unde...

Deployable Twin-Calorimeter System for Absolute Dose Measurements By Clinical Physicists

Authors: Jean Dessureault, Malcolm R. McEwen, Bryan R. Muir, James Renaud

Affiliation: National Research Council

Abstract Preview: Purpose: To develop and commission a mailable calorimeter that enables clinical medical physicists to quickly and efficiently address innovative dosimetry challenges directly at the point of use.
<...

Dosimetry for Low Energy Electrons and Their Potential Use in Radiotherapy

Authors: Christoph Bert, Leon Brückner, Luitpold Distel, Julian Freier, Peter Hommelhoff, Bastian Löhrl

Affiliation: Department of Radiation Oncology, Uniklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Department Physik, Friedrich-Alexander Universität Erlangen-Nürnberg

Abstract Preview: Purpose: Low energy electron (LEE) bunches in the kilo electronvolt (keV) range are thought to have a high relative biological effectiveness (RBE). To investigate this, it is necessary to establish re...

Dosimetry of Gamma Knife Stereotactic Radiosurgery Tissue Heterogeneity Corrections for Pituitary Adenomas

Authors: James M. Brindle, Gene A. Cardarelli, Alexis Leuci, Mark J. Rivard

Affiliation: Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: Leskell GammaPlan (LGP) is equipped with the Collapsed Cone Convolution (CCC) and TMR10 calculation algorithms. Use of the CCC algorithm accounts for tissue heterogeneities not considered in ...

Establishing a Conventional Linac-Based Electron Flash Beam

Authors: Christopher Bartee, Justin Riley DeFrancisco, Marcos Feijoo, Siyong Kim, Tianjun Ma

Affiliation: Blue Physics LLC, Virginia Commonwealth University

Abstract Preview: Purpose: Irradiation with FLASH has been shown to decrease normal tissue toxicity while maintaining similar tumor control. To advance FLASH into the clinic, more preclinical investigations are first n...

Evaluation of the Hyperscint RP-200 Plastic Scintillation Dosimetry System for Reference Dosimetry in Ultra-High Dose Rate Electron Beam Therapy: A Comparative Study

Authors: Julie Colnot, Eric Deutsch, Christelle Huet, Danahé LeBlanc, Pauline Maury, Charlotte Robert, Imane Saïd Mansour, Cathyanne Schott, Francois Therriault-Proulx

Affiliation: INSERM U1030, Gustave Roussy, University Paris-Saclay, LDRI, IRSN, Medscint, THERYQ / INSERM U1030, Gustave Roussy, University Paris-Saclay, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique

Abstract Preview: Purpose: FLASH radiotherapy, using ultra-high dose rates (UHDR, >100 Gy/s), spares healthy tissues while maintaining tumor control compared to conventional radiotherapy (CONV). However, UHDR dosimetry...

Feasibility of Producing GRID Therapy Dosimetry Using a Compact Linac Treatment Head with Pencil Beam Scanning

Authors: Yiran Liu, Zhengzheng Liu, Fang-Fang Yin

Affiliation: Duke Kunshan Univeristy, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: To investigate the feasibility of producing high dose rate GRID therapy using a compact linear accelerator (LINAC) treatment head with scanning beam and stationary grid collimator.
Methods...

Impact of Diacetylene Polymer Chemistry on Real-Time Radiochromic Film Dosimetry

Authors: Rohith Kaiyum, Ozzy Mermut, Alexandra Rink

Affiliation: Department of Medical Biophysics, University of Toronto, Department of Physics and Astronomy, York University

Abstract Preview: Purpose: To investigate the relationship between chemical features and real-time response to ionizing radiation dose of radiochromic diacetylene crystals.
Methods: A number of radiochromic diacetyl...

Investigating the Flash Effect: Uncovering Brain Sparing and Cognitive Preservation across Varying Dose Rates in Whole-Brain Irradiation of in-Vivo Mouse Models

Authors: Denise Dunn, Scott R. Floyd, Tyler V. Kay, Anna Lynnette-Price, Eric L. Martin, Stepan Mikhailov, Taylor Nguyen, Mark Oldham, Victoria J. P. Radosova, Zachary J. Reitman, Ramona Rodriguiz, Andrew Thompson, William Wetsel, Seth Wilcox, Ying Wu

Affiliation: Duke University Mouse Behavior Core, Department of Physics, Duke University, Medical Physics Graduate Program, Duke University, Duke University Medical Physics Program, Duke University, Duke University Mouse Behavioral and Neuroendocrine Analysis Core Facility, Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: FLASH radiation therapy (RT) shows promise for reducing normal tissue damage, though its mechanisms remain unclear. Using an in-vivo model with the High Intensity Gamma-ray Source (HIGS) lina...

Investigating the Radiation Chemistry of Flash Radiation Therapy through Electron Paramagnetic (EPR) Spectroscopy

Authors: Ramin Abolfath, Alexander Baikalov, Stefan Bartzsch, Nolan M. Esplen, Alan Eduardo Lopez Hernandez, Emil Schueler

Affiliation: MD Anderson Cancer Center, PI Experimental Medical Physics, Institute of Radiation Medicine (IRM), Helmholtz Munich, Germany, Howard University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: FLASH radiation therapy (FLASH-RT) leverages ultra-high dose rates (UHDR) to spare normal tissue as compared to conventional (CONV)-RT while preserving tumor control; this is termed the FLASH...

Monte Carlo Derived Correction Factors for Ion Chambers Used in the Calibration of Gamma Knife Perfexion Model: Impact of Phantom Materials and Chamber Orientation on Dosimetric Accuracy

Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: Commissioning of a Gamma Knife® (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...

Monte Carlo Evaluation of Water-Equivalent Materials for Nanowire-Based Oslds in Flash Radiotherapy

Authors: James Chun Lam Chow, Harry E Ruda

Affiliation: University of Toronto, Princess Margaret Cancer Centre

Abstract Preview: Purpose: FLASH radiotherapy (FLASH-RT) with dose rate greater than 40 Gy/s, has demonstrated potential in reducing normal tissue toxicity while maintaining tumor control. However, accurate and reliabl...

Phase One Randomized Two-Arm Dose Escalation of Flash RT in Veterinary Canine Osteosarcoma: Trial Design & Initial Results

Authors: Wesley S. Culberson, Aleksandra Ilina, Brian W Pogue, Matthew Reed, Connor Strainis, William Scott Thomas, Nathaniel Van Asselt, Albert van der Kogel

Affiliation: University of Wisconsin: Madison, University of Wisconsin: Madison School of Veterinary Medicine, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin–Madison, University of Wisconsin-Madison, University of Wisconsin - Madison

Abstract Preview: Purpose: FLASH radiotherapy reduces skin damage in vivo from ultra-high dose rate (UHDR) irradiation relative to conventional dose rates (CDR), while preserving damage to tumor tissue. The FLASH effec...

Preclinical Dosimetric Evaluation for Small Animal Study to Investigate Normal Tissue-Sparing Effects in the Electron Ultra-High Dose-Rate (FLASH) Environment

Authors: Ashok Bhandari, Andrew Joseph Fanning, Kyle J. Gallagher, Brendan Graff, Christopher Jenkins, Kyuhak Oh, Ying Yan, Su-Min Zhou

Affiliation: University of Nebraska Medical Center

Abstract Preview: Purpose: This study aimed to design a robust experimental setup to ensure accurate dose delivery using ultra-high-dose-rate for small animal experiments by conducting dosimetric evaluations prior to a...

Radio-Acoustic Monitoring of Electron Flash Therapy In Vivo

Authors: Kristina Bjegovic, Luke Connell, Emil Schueler, Leshan Sun, Lucy Whitmore, Liangzhong Xiang

Affiliation: University of California, Irvine, MD Anderson, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The use of FLASH-RT in the clinic would greatly reduce off-target radiation toxicity in normal tissues. However, due to the hypo-fractionated delivery of prescribed doses at FLASH dose rates,...

Real-Time Output Gating and Fault Handling for an Uhdr Mobetron

Authors: Petr Bruza, David J. Gladstone, Lesley A Jarvis, Austin Sloop, Kevin J. Willy, Rongxiao Zhang

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose:
Active beam monitoring and output-gated dosimetry are essential systems for safe and accurate radiation delivery. UHDR irradiators such as the Mobetron rely on pre-programmed regimes and t...

Secondary Neutron Dosimetry of Cieds Exposed to Neutron-Producing Photon Radiation Therapy

Authors: Angela Gearhardt, Stephen F. Kry, Christopher Ryan Peeler, Julianne M. Pollard-Larkin

Affiliation: The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences; The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: A growing number of radiation therapy (RT) patients have cardiovascular implantable electronic devices (CIEDs). Patients with CIEDs must be carefully managed because the devices are susceptib...

Spatial Variation and Dosimetry of X-Ray Contamination in Total Skin Electron Beam Therapy

Authors: William G. Breen, Dalton Griner, Scott C Lester, Joseph John Lucido, Beth A. Schueler, Jack C. Thull

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Designing a total skin electron (TSE) beam therapy protocol requires finding the optimal balance between penetration depth, field uniformity, and x-ray contamination (XC). To better understan...

The Development of Large Field MR Guided Radiotherapy for Pelvic Lymph Node SBRT and Its Dosimetry Improvement

Authors: David Byun, Ting Chen, Paulina E. Galavis, Allison McCarthy, Hesheng Wang, Michael J Zelefsky

Affiliation: NYU Langone Health

Abstract Preview: Purpose: To summarize a MR guided adaptive workflow developed for pelvic lymph nodes (PLN) stereotactic radiotherapy using large field size on Elekta Unity© MR Linac system, and to quantitatively anal...

The Topas Monte Carlo Framework – Status and Outlook after 15 Years of Development

Authors: Alejandro Bertolet, Jorge Naoki Dominguez Kondo, Bruce A. Faddegon, Thongchai Masilela, Isaac Meyer, Victor V. Onecha, Harald Paganetti, Jose A. Ramos-Mendez, Jan PO Schuemann, Wook-Geun Shin

Affiliation: University of California San Francisco, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital

Abstract Preview: Purpose: To present the results of 15 years of developments of the TOPAS TOol for PArticle Simulation framework, and to highlight recent and new developments.

Methods: Fundamental understanding...

Towards Clinical Translation: Optical Methods Deliver in-Vivo per-Pulse Dosimetry in Electron Flash-RT

Authors: Petr Bruza, Rafael Carballeira, Megan Clark, David J. Gladstone, Austin Sloop, Roman Vasyltsiv, Kevin Jacob Willy

Affiliation: Dartmouth College, Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: Develop an optical dosimetry system to accomplish standard of care on-patient dosimetry and pretreatment quality assurance for ultra-high dose rate (UHDR) electron therapy ahead of human tria...

Ultra-Fast Commissioning and Quality Assurance with Plastic Scintillation Detector

Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din

Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University

Abstract Preview: Purpose: Accurate, efficient, and reliable commissioning of linear accelerator (LINAC) is critical for ensuring high-quality radiation therapy treatments. The study uses advanced detector technology a...

Ultrasonic Detection of Flash-Level Dose Pulses from a Medical Linac

Authors: Fred B. Bateman, Ilaria M. Luna, Ronald E. Tosh

Affiliation: Sidwell Friends School, NIST, Dosimetry Group, Radiation Physics Division, National Institute of Standards and Technology

Abstract Preview: Purpose: To exploit the rapid response time and dose sensitivity of ultrasonic detection methods for resolving pulse structure in FLASH-level beams.

Methods: Two ultrasonic transducers position...

Validation of 3D Pseudo-Dose Map Reconstructed from Multi-View Cherenkov Images in Total Skin Electron Therapy

Authors: Brook Byrd, Lisha Chen, Michael LaRiviere, Baozhu Lu, John Plastaras, Brian W Pogue, Emily Xiong, Timothy C. Zhu, Yifeng Zhu

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, University of Wisconsin - Madison

Abstract Preview: Purpose: For total skin electron therapy (TSET), achieving optimal dose distribution depends on precise patient positioning, which is often influenced by daily variability. Cherenkov imaging offers a ...

WGTG51 AAPM Report #385 Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy electron beams

Authors: Bryan R. Muir

Affiliation: National Research Council

Abstract Preview: N/A...

dosimetric Characterization of Tungsten Eye Shields Using Monte Carlo Simulation

Authors: Omer Abdulaziz Ali, Robin Hill, Nathan Huntelerslag

Affiliation: Waikato Hospital, Hamilton, New Zealand, Central Coast Cancer Centre, Gosford, Australia

Abstract Preview: Purpose: Characterizing transmission through eye shields is essential to understanding dose distribution in underlying tissues. This study aims to utilize Monte Carlo (MC) simulations to model and cha...