Search Submissions 🔎

Results for "energy measurement": 87 found

3D Printing Assisted Collimator Design for Fan Beam-Based X-Ray Fluorescence Tomographic Imaging

Authors: Brett Bocian, Nesrin Dogan, John C. Ford, Alan Pollack, Ryder Marshall Schmidt, Junwei Shi, Jorge D Vega

Affiliation: University of Miami, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: X-ray fluorescence computed tomography (XFCT) is an emerging molecular imaging modality gaining attention in cancer theranostics with high-Z metal nanoparticles (MNPs). While XFCT has been de...

6FFF Beam Output Trend Showing Target Degradation

Authors: Sean L. Berry, Hsiang-Chi Kuo, Seng Boh Gary Lim, Ingrid Valencia Lozano, Laszlo Voros

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
To quantify the impact of target degradation on 6FFF beam output by analyzing the output trends and adjustment frequencies at our clinic on a flattening filter-free (6FFF) and a flattened ...

A Dosimeter Independent Method for Measuring Dose from Contrast Enhanced Mammography Exposure.

Authors: Mitya M. Barreto, Nichole A. Harris

Affiliation: Department of Radiology, University Hospitals Cleveland Medical Center

Abstract Preview: Purpose: To evaluate dosimeter dependence of measured AGD, and to develop a dosimeter independent method for evaluating the AGD, for CEDM exposures.
Methods: Three solid-state dosimeters (Raysafe-X...

A GPU Accelerated Monte Carlo Dose Engine for Small Animal Proton Radiotherapy

Authors: Haonian Gong, Yue Gu, Meiqi Liu, Zihao Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang, Cheng Zheng

Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose:
Proton radiotherapy in preclinical small animals requires specific dose engine due to its low energy and small irradiation volume. This study is to develop a GPU-based Monte Carlo dose eng...

A Monte Carlo Framework for Automated Quality Assurance of Dynamically Collimated Pencil Beam Scanning Clinical Treatment Deliveries

Authors: Laura Bennett, Wesley S. Culberson, Albert Du, Kevin J. Erhart, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake

Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care, .decimal

Abstract Preview: Purpose: To develop and experimentally validate a novel Monte Carlo (MC) framework designed to enable calculation-based quality assurance (QA) for collimated intensity modulated proton therapy treatme...

A New Algorithm for Charged Particle Therapy Beam Energy Measurement By Time-of-Flight

Authors: Sung Woon Choi, Dong Wook Kim, Jin Sung Kim, Na Hye Kwon, Paulo Jorge Ribeiro Da Fonte

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Coimbra Institute of Engineering, Polytechnic University of Coimbra

Abstract Preview: Purpose: In hadrontherapy, such as proton and carbon ion therapy, it is desirable, for quality assurance reasons, to have an online beam energy measurement independent from the machine parameters. Sin...

A Novel Process for Electron Beam Matching on Varian True Beams

Authors: Andrew Clarke Grice, Evan A. Silverstein

Affiliation: Sutter Medical Foundation, Sutter Health

Abstract Preview: Purpose: To implement an efficient and effective process for Electron beam matching between 5 Varian True Beams (TB).
Methods: We adapted the Varian installation/acceptance process for TBs, whereby...

Absolute Measurement of HDR Ir-192 Air-Kerma Strength Using an Exradin A3 Known-Volume Ionization Chamber

Authors: Larry A. DeWerd, Sean Jollota, Karen Rex Pius Vincent

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Absolute measurements, often used to establish primary standards, offer lower measurement uncertainty. For 192Ir high-dose-rate (HDR) brachytherapy, the interim primary standard for air-kerma...

Advancing Flash Radiotherapy: Intercomparison of Parameters between Two Institutions to Optimize Clinical Applications.

Authors: Amir Abdollahi, Celine Karle, Michele M. Kim, Constantinos Koumenis, Andrea Mairani, Erato Stylianou Markidou

Affiliation: Heidelberg Ion-Beam Therapy Center - Department of Radiation Oncology, German Cancer Research Centre(DKFZ), University of Pennsylvania, Physics Dep. University of Cyprus

Abstract Preview: Purpose: The aim is to compare FLASH dose-rate RT generated with protons and carbon (HIT) and compare to protons (UPenn) to provide evidence for equipotency of FLASH vs. standard RT to tumor growth co...

An Alpha Irradiation System for Radiobiological Studies with Versatile Dose Rate Control

Authors: Harsh Arya, Yan Chang, Yujie Chi, Varghese Anto Chirayath, Joshua Rajan, Pan Zui

Affiliation: University of Texas at Arlington, Department of Physics, University of Texas at Arlington

Abstract Preview: Purpose: In targeted alpha therapy (TAT), absorbed dose rates can vary significantly spatially and temporally, impacting therapeutic efficacy as well as carcinogenic potential. This study reports the ...

An Analytical Framework to Quantify the Effect Obstructing Anatomical Features in Intrafractional Spectral Imaging Using a Dual-Layer Kv Imager

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Marios Myronakis

Affiliation: Medical Physics Department, Medical School, University of Thessaly, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory

Abstract Preview: Purpose:
Dual-layer kV imager (DLI) architecture enables the capability for single-shot dual-energy (DE) intrafraction imaging. As noise from individual DLI layers are primarily uncorrelated, simpl...

An International Survey of High Dose Rate Brachytherapy Dosimetry Practices

Authors: Anna Becker, Tomislav Bokulic, Mauro Carrara, Krzysztof Chelminski, Larry A. DeWerd, Alexis Dimitriadis, Benjamin Kellogg, Malcolm R. McEwen, Zakithi L.M Msimang, Mark J. Rivard, Thorsten Sander, Thorsten Schneider, Jamema Swamidas, Egor Titovich, Paula Toroi, Carlos E. de Almeida, Jacco de Pooter, Liset de la Fuente Rosales, Deborah G. van der Merwe

Affiliation: Radiation and Nuclear Safety Authority, University of Zagreb, National Physical Laboratory, IAEA, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Rio de Janeiro State University, Dosimetry Laboratory, Dosimetry and Medical Radiation Physics Section, Division of Human Health, International Atomic Energy Agency, Physikalisch-Technische Bundesanstalt, National Metrology Institute, University of the Witwatersrand, Dosimetry and Medical Radiation Physics Section, Division of Human Health, International Atomic Energy Agency, National Research Council, Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: The recently published IAEA-TRS-492 international code of practice (CoP) aims at improving traceability, accuracy, and consistency in Brachytherapy Dosimetry. To assess current approaches to ...

Application of a Flashdiamond Detector Coupled to a Beam Current Transformer to Commission a Monte Carlo Model of a Ultra-High Dose Rate Electron Beam

Authors: Javier Chiasson, Dominique Guillet, Arthur Lalonde, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal

Abstract Preview: Purpose:
To validate a Monte Carlo (MC) model of a Ultra-High dose rate (UHDR) electron beam using a prototype flashdiamond (fD) detector coupled to an electrostatically shielded beam current trans...

Artificial Intelligence-Powered Conventional Energy Integrating Detector-Based Coronary CT Angiography: Learning High-Resolution and Multi-Energy Imaging from Photon-Counting Detector CT

Authors: Shaojie Chang, Thomas A. Foley, Hao Gong, Emily Koons, Shuai Leng, Cynthia H. McCollough, Eric E. Williamson

Affiliation: Mayo Clinic

Abstract Preview: Purpose: To enhance coronary CT angiography (cCTA) capabilities on conventional energy integrating detector CT (EID-CT) using artificial intelligence (AI). The AI framework incorporates high-resolutio...

Assessing Long-Term Stability of Parylene-Coated, 3D-Printed Plastic Vessels for Water Calorimetry-Based Radiation Dosimetry

Authors: Philip Cutter, Mark D'Souza, Arman Sarfehnia

Affiliation: Toronto Metropolitan University, Sunnybrook Health Sciences Centre, Sunnybrook Health Science Center

Abstract Preview: Purpose: Water calorimetry (WC) serves as an important standard for measuring absorbed dose to water, an essential metric in radiation therapy. WC directly and absolutely quantifies energy deposition ...

Assessing the Feasibility of LD-V1 Film for Annual Kilovoltage Imaging Dose Measurements

Authors: Maria F. Chan, Seng Boh Gary Lim, Shih-Chi Lin, Dustin W. Lynch, Usman Mahmood, Jeonghoon Park

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To explore the feasibility of using GafChromic LD-V1 film for annual imaging dose assessment across kV radiography, fluoroscopy, and cone beam computed tomography (CBCT) imaging protocols, as...

BEST IN PHYSICS THERAPY: Fast and Convenient Proton Pencil Beam Energy QA with Multi-Layer Faraday Cup (MLFC)

Authors: Paul Boisseau, Eric S. Diffenderfer, Andrew Friberg, Wenbo Gu, Matthew Nichols, Kan Ota, Xiaokun Teng, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology, University of Pennsylvania, Pyramid Technical Consultants, Inc., University of Pennsylvania

Abstract Preview: Purpose: Traditional quality assurance procedures for proton pencil beam energies involve water tank setups or multiple solid water phantoms and are time-consuming. This study demonstrates that an inn...

Calorimetric Measurement of Absorbed Dose By a Flash Beamline

Authors: Luke Connell, Stephen F. Kry, Malcolm R. McEwen, Bryan R. Muir, James Renaud, Emil Schueler, Hayden Scott, Paige A. Taylor

Affiliation: National Research Council, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: To demonstrate the capability of a robust calorimeter to accurately determine the absorbed dose delivered by an electron FLASH beamline.

Methods: Electron FLASH beams of 6 MeV and 9 Me...

Characterization of Commercially-Available Dosimeters and Prototype Diamond Detectors for Absolute Flash Dosimetry of Small-Field Pulsed Proton Beams

Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang

Affiliation: 4Physikalisch-Technische WerkstÀtten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...

Characterization of Linear Energy Transfer Spectra in Mini Beam Spatially Fractionated Proton Therapy

Authors: Serdar Charyyev, Kaan Dere, Edgar Gelover, Mohammad Khurram Khan, Liyong Lin, Mark McDonald, Cristina Oancea, Alexander Stanforth, Sibo Tian, Suk Whan (Paul) Yoon, Mingyao Zhu

Affiliation: Department of Radiation Oncology, Stanford University, Stanford University, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University, Advacam

Abstract Preview: Purpose: The conventional implementation of proton spatially fractionated radiotherapy (SFRT) utilizes physical collimators with apertures to generate minibeams, creating alternating regions of high-d...

Characterization of Novel Shielded and Unshielded Silicon Diode Detectors for Photon and Electron Dosimetry in Radiation Therapy

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum fĂŒr Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize the performance of novel shielded and unshielded silicon diode detectors in relative photon and electron beam dosimetry.

Methods: The novel shielded and unshielded sili...

Characterization of a Prototype Flashdiamond Detector for Conventional and Uhdr Beams

Authors: Dominique Guillet, Arthur Lalonde, Bryan R. Muir, James Renaud, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal, National Research Council

Abstract Preview: Purpose:
To evaluate the dose rate dependence, beam quality dependence, and short-term stability of a novel flashDiamond (fD) prototype detector for conventional and ultra-high dose rate (UHDR) bea...

Characterizing an Osld Dosimetry System for Use in a Multi-Clinic Environment

Authors: Amar K. Basavatia, Lee C. Goddard, Rachel Grimm, Wolfgang A. Tomé

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: To characterize the “MyOSL Chip” OSLD system for clinical use and compare the response of multiple readers to allow for utilization in a multi-clinic environment.
Methods: Dose calibration...

Combining Proton Flash and Spatially Fractionated Radiotherapy – Experimental and Simulation Based Dosimetric Characterization

Authors: Gulakhshan M Hamad, Sina Mossahebi, Yannick P. Poirier, Amit Sawant

Affiliation: University of Maryland School of Medicine, Maryland University Baltimore

Abstract Preview: Purpose:
The combination of ultra-high dose rate (UHDR) proton therapy, known for normal tissue sparing, with spatially-fractionated radiotherapy (SFRT), promising enhanced tumor control and tissue...

Commissioning Radcalc v7.3 with a Collapsed Cone Calculation Algorithm for 6X FFF and 10X FFF Energies

Authors: Maria Jose Almada, Carlos Bohorquez, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger

Affiliation: LAP, Instituto Zunino - Fundacion Marie Curie

Abstract Preview: Purpose:
PSQA is crucial in maintaining patient safety, typically depending on dosimetric measurements. However, advancements in computational technology have highlighted the growing significance o...

Commissioning a Fixed Beamline Ultra-High Dose Rate Proton Therapy System

Authors: Ahmet S. Ayan, Austin M. Faught, Eunsin Lee, Julia Pakela

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University

Abstract Preview: Purpose: To present commissioning of a fixed beamline ultra-high dose rate proton pencil beam scanning system, the world’s first multi-room Varian ProBeam360⁰
Methods: The fixed beamline pencil bea...

Commissioning of a 3D-CRT Planning Software for a Machine with Only Flattening-Filter Free Energy

Authors: Michalis Aristophanous, Steven Blum, Laura I. Cervino, Antonio L. Damato, Karen Episcopia, Chi Huang, Shih-Chi Lin, Michelle K. Savacool

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Varian Ethos (Varian Medical Systems, Palo Alto, CA) is a 6 MV flattening-filter-free (FFF) only machine, posing a challenge in creating homogeneous dose distributions when using manual 3D-CR...

Commissioning of a Near Real-Time In Vivo Film Dosimetry System

Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...

Commissioning, Validation and Pilot Study of New Rpld System for Dosimetry Audits in Bulgaria

Authors: Gueorgui Gueorguiev, Katia Sergieva, Filip Simeonov, Tsvetelina Todorova, Bozhidar Vladimirov

Affiliation: National Centre of Radiobiology and Radiation Protection, Queen Giovanna University Hospital

Abstract Preview: Purpose: Dosimetry audit is an essential tool enhancing confidence in the accuracy of treatment delivery and in prevention of radiation treatment incidents. Current work depicts how novel nationwide r...

Comparative Evaluation of Spekpy for Kilovoltage Beam Quality Characterization

Authors: Chang Heon Choi, Yoonsuk Huh, Jin Jegal, Seonghee Kang, Jung-in Kim, Inbum Lee, Hyojun Park

Affiliation: Department of Radiation Oncology, Seoul National University Hospital

Abstract Preview: Purpose: This study evaluates SpekPy, a Python-based tool for modeling kilovoltage (kV) x-ray spectra, by comparing its calculated energy spectra, half-value layer (HVL), and air kerma with experiment...

Comparing the Rsp Accuracy of a Fast Switching Dual-Energy CT to Single-Energy CT Using Proton CT in Animal Tissue.

Authors: Paul Deak, Yang Li, Mark Pankuch, Yanling Qu, Maggie Stauffer, Hazel Wang

Affiliation: Northwestern Medicine Proton Center, GE, Northwestern Medicine

Abstract Preview: Purpose: The objective is to evaluate Relative Stopping Power(RSP) accuracy of ultra-fast switching KV Dual-Energy CT(DECT) in animal tissue and compare it to the RSP converted from Single Energy CT(S...

Deep Learning-Based Prompt Gamma Imaging for Proton Range Verification Using Patient Data Simulation

Authors: Mostafa Cham, Matthias K Gobbert, Zhuoran Jiang, Sina Mossahebi, Ruth Obe, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma

Affiliation: University of Maryland School of Medicine, UMBC, University of Maryland Baltimore County, University of Maryland, Baltimore County, Stanford University, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc, Department of Infomation Systems, UMBC

Abstract Preview: Purpose: Compton camera (CC)-based prompt gamma imaging (PGI) offers real-time proton range verification. However, its limited-angle measurements cause severe distortions in PGI, affecting its clinica...

Detection of the Linac Jaw Face Angle Misalignment: Case Studies

Authors: Peter Balter, Andres V Cibrian, Song Gao

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The purpose of this study is to demonstrate a means of detecting misaligned jaw face angles on the Varian TrueBeam based on a beam symmetry metric for electron beam profiles.
Methods: Duri...

Determining Optimal Delivery Pattern for Reference Dosimetry in Pencil Beam Scanning Proton Therapy

Authors: Clifford Ghee Ann Chua, Calvin Wei Yang Koh, Kah Seng Lew, Zubin Master, Sung Yong Park, Hong Qi Tan, Andrew Wibawa

Affiliation: National Cancer Centre Singapore

Abstract Preview: Purpose: To investigate the impact of spot position deviation on reference dosimetry measurements using different delivery patterns and to determine the optimal delivery pattern for reference dosimetr...

Development and Validation of Patient-Specific 3D-Printed Electron Applicators for Precision Radiotherapy

Authors: Md. Jobairul Islam

Affiliation: Department of Radiation Oncology, Labaid Cancer Hospital and Super Speciality Centre

Abstract Preview: Purpose: Electron radiotherapy is an effective treatment for superficial tumors but requires field-shaping devices like electron applicators, which are labor-intensive to produce. This study aimed to ...

Dosimetric Characterization of Sun Nuclear EDGE Diodes in the Plateau Region of Proton Pencil Beam Scanning (PBS) Fields

Authors: Wesley S. Culberson, Ryan Gardner, Patrick M Hill, Mark Pankuch, Karsten K. Wake

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Wisconsin, Northwestern Medicine Proton Center

Abstract Preview: Purpose: To assess the dosimetric capabilities of Sun Nuclear (Melbourne, FL) EDGE Diode Detectorsℱ for measurements in the plateau region of pencil beam scanning (PBS) fields. Many clinical dosimeter...

Dosimetric Comparison & Error Analysis of Aapm TG51 & WGTG51-e Protocol with Icru-90 Key-Data for High-Energy Clinical Electron Beam

Authors: Amar K. Basavatia, Sandeepan Ganguly, Lee C. Goddard, Wolfgang A. Tomé

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: To investigate the dosimetric impact of WGTG51-e Report 385, recently updated CoP for clinical electron beams. This study uses a chamber specific effective point of measurement (EPOM) shift t...

Dosimetry Calibration for Low-Energy Protons (2-4 MeV) Using Gafchromic Film Dosimeters

Authors: Michael Dingfelder, Homeira Faridnejad

Affiliation: East Carolina University, Department of Physics, East Carolina University

Abstract Preview: Purpose: To use Gafchromic film for measurement of the dose delivered by low-energy (2-4 MeV) protons to living cells.
Methods: Five different types of Gafchromic films were tested for dosimetry un...

Dosimetry Impact of Beam Flatness on a Clinical Synchrocyclotron Proton System

Authors: Winter Green, Yao Hao, Nels C. Knutson, Matthew C. Schmidt, Xiandong Zhao

Affiliation: Washington University School of Medicine in St. Louis, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine, WashU Medicine

Abstract Preview: Purpose: Beam profile flatness is crucial for both photon and proton radiotherapy systems. This work investigated the dosimetry impact of beam flatness on a clinical synchrocyclotron proton system.

Dosimetry for Low Energy Electrons and Their Potential Use in Radiotherapy

Authors: Christoph Bert, Leon BrĂŒckner, Luitpold Distel, Julian Freier, Peter Hommelhoff, Bastian Löhrl

Affiliation: Department of Radiation Oncology, Uniklinikum Erlangen, Friedrich-Alexander-UniversitĂ€t Erlangen-NĂŒrnberg, Department Physik, Friedrich-Alexander UniversitĂ€t Erlangen-NĂŒrnberg

Abstract Preview: Purpose: Low energy electron (LEE) bunches in the kilo electronvolt (keV) range are thought to have a high relative biological effectiveness (RBE). To investigate this, it is necessary to establish re...

Dual-Energy CT Derived Perfusion Blood Volume and 4D-CT Derived Ventilation Changes in Lung Cancer Patients 6-Months Post Radiation Therapy

Authors: Daniel A. Alexander, Jeffrey D. Bradley, Steven J. Feigenberg, Cole Friedes, Casey Hollawell, William Levin, Maksym Sharma, Boon-Keng Kevin Teo, Ying Xiao, Nikhil Yegya-Raman, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology and Applied Sciences, Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: To investigate lung function changes following definitive chemoradiation dose using CT-derived measurements in patients with locally advanced NSCLC at 6-months post-treatment compared to pre-...

Evaluation of Nodule Volume Accuracy with Deep Learning-Based Reconstructions on Cdznte Photon-Counting and Energy-Integrating CT

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal

Affiliation: Radboud University Medical Center, University of SĂŁo Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de FĂ­sica Gleb Wataghin

Abstract Preview: Purpose: This study aimed to evaluate the precision and accuracy of volume measurements for solid nodules (SNs) and ground-glass opacities (GGOs) in lung images acquired using energy-integrating CT (E...

Evaluation of an Analytical Simulation Technique By Comparing Transmitted Spectra Against GEANT4 through a Hafnium-Loaded Heterogeneous Phantom

Authors: Sabrina Campelo, Sandun Y. Jayarathna, Adam D. Melancon, Paige L. Nitsch, Christopher Ryan Peeler, Julianne M. Pollard-Larkin, Ramaswamy Sadagopan, Xiaochun Wang, George Zhao

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Development of an in-house analytical simulation for streamlining photon counting detector (PCD) system protocols through measuring transmitted photon energy spectra through a Hafnium (Hf)-lo...

Evaluation of the Dosimetric Characteristics of Multi-Layers of Brass Mesh Bolus for Electron Treatment

Authors: Yunzhi Ma, Ling Zhuang

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: Multiple layers of brass mesh bolus (RPD, Inc., Albertville, MN) may be needed to provide better body conformity and sufficient dose build up on patient surface during electron treatment. Thi...

Extremity Imaging with Cone-Beam CT (CBCT) Scanner Dedicated for Hip Imaging – What Are the Effective Doses?

Authors: Jeff Boob, Jaydev K. Dave, Tim Minch, Bhavyata Tanna

Affiliation: Dr. Ronald E. McNair Academic High School, Mayo Clinic, CurveBeam AI

Abstract Preview: Purpose: To compute effective doses associated with imaging of the extremities with a HiRise (CurveBeam AI, Hatfield, PA) cone-beam CBCT scanner specifically designed for weight-bearing imaging of the...

Feasibility Study of the Auger Electron Radiation Therapy

Authors: Chen-Ju Feng, Shih-Ming Hsu, Chin-Hsiung Lin, Shih-Yong Luo, Shao-Chun Tseng, Chin-Hui Wu, Ya-Ru Yang

Affiliation: National Yang Ming Chiao Tung University, Koo Foundation Sun Yat-Sen Cancer Center, Tzu-Chi University, NanoRay Biotech Co., Ltd

Abstract Preview: Purpose: The range of auger electrons in water is 2~500 nm, and its linear energy transfer reaches 26 keV/ÎŒm. This study investigated the feasibility of the auger electron radiation therapy.
Method...

Feasibility and Consistency of a Quad Wedge with a 2D Detector Array for Routine Quality Assurance on a MR-Linac

Authors: Grace Hutchinson, Daniel E. Hyer, Samuel D. Rusu, Blake R. Smith, Joel J. St-Aubin

Affiliation: Iowa Health Care, University of Iowa

Abstract Preview: Purpose: To assess the feasibility and consistency of the Sun Nuclear Corporation (SNC) MR conditional Quad Wedge, as an accessory to the IC Profiler-MR, and to evaluate beam output and energy in the ...

Feasibility of a Bench-Top Pcct Model for Electronic Density Measurements: A Monte Carlo Simulation Study

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Renan Felix dos Santos, Gustavo Freire Pereira da Silva, Alessandra Tomal

Affiliation: University of SĂŁo Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de FĂ­sica Gleb Wataghin

Abstract Preview: Purpose: Evaluate the feasibility of a bench-top PCCT using Geant4 Monte Carlo simulations. The study applied the Geant4 framework on determining the electronic density of materials as a function of C...

Feasibility of a Normoxic N-Vinylpyrrolidone-Based Polymer Gel (VIPET) Dosimeter for Three-Dimensional Proton Beam Measurements

Authors: Yoshihiko Hoshino, Kenji Hotta, Taeko Matsuura, Ai Nakaoka, Hidenobu Tachibana

Affiliation: Hokkaido University, Department of Radiology, Gunma University Hospital, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East

Abstract Preview: Purpose: Gel dosimeters enable three-dimensional dose measurements, but no reports have evaluated the fundamental performance of VIPER-type gel dosimeters in proton beam measurements. Therefore, we ev...

First Beam Characterization of the Radiabeam FLEX-9 Electron Flash Linac

Authors: Robert Berry, John Buatti, Nathan Burger, Ryan T. Flynn, Greg Johns, Maksim Kravchenko, Sergey Kutsaev, Yen-Po Lee, Marcos Ruelas, Joel J. St-Aubin, Timothy J. Waldron

Affiliation: RadiaBeam Technologies, University of Iowa

Abstract Preview: Purpose: To report the factory acceptance tests of a preclinical linear accelerator, the FLEX-9 electron FLASH linac from RadiaBeam Technologies.
Methods: The FLEX-9 FLASH electron linac is designe...

First-Time Live Imaging of Radiopharmaceutical Administration with a Hybrid Compton Camera

Authors: Ramesh Boggula, Jay W. Burmeister

Affiliation: Wayne State University, Karmanos Cancer Center, Gershenson ROC, Wayne State University School of Medicine

Abstract Preview: Purpose: This study evaluated the performance of a hybrid Compton camera for real-time imaging during the administration of Lu-177-based radiopharmaceuticals, including Pluvicto and Lutathera. The aim...

High Dose Rate Electron Beam Depth Dose Characterization

Authors: Fitria P Krisna, Mardon Limena, Supriyanto Ardjo Pawiro, Jhon H Saragih, Wahyu E. Wibowo, Poonam Yadav, Ummu M Zahro

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Radiation Oncology Dr. Cipto Mangunkusumo National Central Public Hospital, Department of Physics, Mathematics and Natural Sciences, University of Indonesia, Department of Radiotherapy, Mandaya Hospital, Department of Radiation Oncology, Mitra Keluarga Kenjeran Hospital, Department of Radiotherapy, Mandaya Royal Hospital, Radiation Oncology, Santosa Hospital

Abstract Preview: Purpose: To perform depth dose characteristics of High Dose Electron Beam and utility of various commercially available detectors.
Methods: The measurements were performed using an Elekta Versa HD ...

High-Energy Current Detectors for Proton Dose-Rate Beam Monitoring at Flash Dose-Rates.

Authors: Davide Brivio, Lia Carroll, Juliane Daartz, Jan PO Schuemann, Piotr Zygmanski

Affiliation: Massachusetts General Hospital, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: We employ High-Energy Current (HEC) detectors for real-time monitoring of proton beams at conventional to FLASH dose rates. This would help overcome the need for fast and accurate dosimeters ...

High-Fidelity Monte-Carlo Model Development and Validation of a 0.5T Bi-Planar Linac-MR Using Topas: Multileaf Collimator Modeling, Positioning, and Dose Verification in Slab Phantoms

Authors: B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Gawon Han, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip

Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute

Abstract Preview: Purpose: To develop and validate a high-fidelity Monte-Carlo (MC) model of a 0.5T bi-planar Linac-MR in TOPAS, focusing on accurate Multileaf Collimator (MLC) modelling and positioning for open apertu...

Imaging Performance of Direct-Indirect Dual-Layer Flat-Panel-Detector Prototypes for Contrast-Enhanced Digital Mammography

Authors: Salman M. Arnab, Yves Chevalier, Samuel Gagné, Adrian F. Howansky, Luc LaperriÚre, Xiangyi Wu, Wei Zhao

Affiliation: Stony Brook Medicine, Analogic Canada

Abstract Preview: Purpose: A direct-indirect dual-layer flat-panel-detector (DI-DLFPD) is under development for patient motion artifact-free contrast-enhanced digital mammography (CEDM). DI-DLFPD comprises a direct fro...

Impact of Ion Chamber Selection on Enhanced Leaf Modeling Predictions of Dosimetric Leaf Gap and Leaf Transmission Factors

Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny

Affiliation: Department of Radiation Oncology, University of Rochester

Abstract Preview: Purpose: A new multileaf collimator (MLC) model has been introduced in Varian Eclipse v18.0, with the treatment planning system (TPS) explicitly modeling the leaf end effects. The vendor recommends a ...

Impact of Photon Beam Energy and Symmetry on the Radial Profile Correction Factor for FFF Beams

Authors: Wesley S. Culberson, Larry A. DeWerd, Ahtesham Ullah Khan, Zachary James Welchel

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, University of Wisconsin-Madison

Abstract Preview: Purpose: Flattening filter free (FFF) linac beams exhibit a centrally peaked beam profile due to the forward-directed bremsstrahlung production from MeV electrons, leading to volume averaging effects ...

Impact of Translucent Sheet Bolus and Melanin Concentration on Recorded Optical Signal during Cherenkov Imaging in External Beam Radiation Therapy

Authors: Jacqueline M. Andreozzi, Savannah Decker, Diego Hernandez, Iman R. Washington

Affiliation: UC San Diego, Department of Radiation Oncology, Moffitt Cancer Center, University of South Florida, Moffitt Cancer Center

Abstract Preview: Purpose: Recent advances in external beam radiation therapy have begun to explore the utility of Cherenkov radiation imaging as a beam delivery visualization tool. When sheet bolus is used during trea...

Innovative Design and Simulation of a Pediatric-Dedicated SPECT: Enhancing Imaging Performance for a Healthier Scans in Children

Authors: Mohammadreza Ay, Nahal Daneshgar, Nima Kasraie, Abbas Monsef, Zeinab Peymani, Hadi Rezaei, Peyman Sheikhzadeh

Affiliation: University of Minnesota Medical School, Radiation Oncology, Department of Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences, Shiraz University of Medical Sciences, Department of Medical Physics, Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, UT Southwestern Medical Center, Imam Khomeini Hospital Complex,Tehran University of Medical Sciences

Abstract Preview: Purpose:
This study aims to design and simulate an innovative pediatric-dedicated SPECT scanner optimized for children’s unique anatomical and safety needs by enhancing sensitivity in data acquisit...

Interplay of Relative Biological Effectiveness and Dose Rate in Eye Plaque Brachytherapy with Low Energy Photons

Authors: Alexei V. Chvetsov, Sunan Cui, Sunyoung Jang, Robert D. Stewart

Affiliation: University of Washington and Fred Hutchinson Cancer Center, Penn State College of Medicine, University of Washington

Abstract Preview: Purpose: To evaluate spatial variation of relative biological effectiveness (RBE) in COMS (Collaborative Ocular Melanoma Study) eye plaques with low energy 125I and 103Pd photon sources as a function ...

Investigating the Effect of Beam Flattening Filter on Dose Estimated with Varian’s Original and Enhanced Mlc Models

Authors: Kenny Guida, Hongyu Jiang, Harold Li, Hem Bahadur Moktan Tamang

Affiliation: University of Nebraska Medical Center, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Varian Eclipse v18.0 introduced Enhanced Leaf Model (ELM) of MLC, which provides better dose calculation accuracy than original DLG-based MLC model. The leaf-gap (LG) parameter for ELM repres...

LD-V1 Film Characterization for MV Beam Quality

Authors: Ruiming Chen Edmondson, Darwin Abraham Garcia, James A. Kavanaugh, Joseph John Lucido

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Characterize the dose response and reproducibility of a low-dose film for 6 MV photon beam and assess the film’s energy dependence between kV and MV energies.
Methods: A single 8’x10’ LD-V...

Lung Nodule Volume Estimation: Performance of Conventional Energy-Integrating and Cdznte-Photon-Counting CT Using Hybrid Reconstruction Method

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal

Affiliation: Radboud University Medical Center, University of SĂŁo Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de FĂ­sica Gleb Wataghin

Abstract Preview: Purpose: The study evaluated the accuracy and precision of lung nodule volume measurements, specifically solid nodules (SNs) and ground-glass opacities (GGOs) in different imaging settings.
Methods...

Material Decomposition with Propagation-Based X-Ray Phase Contrast: A Comparison of Multi-Energy and Multi-Distance Imaging

Authors: Giavanna Luisa Jadick, Patrick J La Riviere

Affiliation: University of Chicago

Abstract Preview: Purpose: We assess two multi-measurement acquisition schemes for material decomposition with x-ray phase-contrast imaging (XPCI); demonstrating for the first time that multi-distance imaging can match...

Modernization of the NIST Air-Kerma Strength Standard for LDR Brachytherapy Seeds

Authors: Michael G. Mitch, Csilla I. Szabo-Foster

Affiliation: National Institute of Standards and Technology

Abstract Preview: Purpose: The U.S. air-kerma strength standard for low-dose-rate (LDR) low-energy photon-emitting brachytherapy sources provides measurement traceability for calibrations at the AAPM Accredited Dosimet...

Monitor Unit (MU) Substructure Analysis for Low MU Deliveries

Authors: Indra J. Das, Ahtesham U. Khan, Andrew J. White, Poonam Yadav

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine

Abstract Preview: Purpose: During intensity modulated radiotherapy (IMRT) planning, low MU segments (< 3 MU) are commonly avoided due to documented dosimetric nonlinearity and poor reproducibility. This work aims to ex...

Monte Carlo Simulation and Dosimetric Verification of 3D Range Modulators for a Multi-Field-Optimization Flash-IMPT Plan

Authors: Michael M Folkerts, Miriam Krieger, Pierre Lansonneur, Gerard Paquet, Petar Penchev, Christoph Schuy, Yuri Simeonov, Uli Weber, Klemens Zink

Affiliation: GSI Helmholtzzentrum fuer Schwerionenforschung, Institute of Medical Physics and Radiation Protection (IMPS), University of Applied Sciences, Varian Medical Systems

Abstract Preview: Purpose:
Ultra-high dose-rate proton irradiation may spare the healthy tissue (FLASH-effect). The 3D-range-modulator (3D-RM) method reduces the treatment time compared to conventional IMPT and can ...

Moving Towards Independent Assays of 90y Glass Microsphere Activity: Monte Carlo Simulation with Experimental Data

Authors: Mercy Iyabode Akerele, Yuni K. Dewaraja, Richard Laforest, Justin K. Mikell, Wendy Siman, Allan Thomas, Daniel Thorek

Affiliation: University of Michigan, Washington University School of Medicine in St. Louis, Washington University School of Medicine, University of Colorado Anschutz Medical Campus, School of Medicine, Washington University in St. Louis, Mallinckrodt Institute of Radiology, Washington University School of Medicine

Abstract Preview: Purpose: Post-therapy quantitative 90Y SPECT and PET measurements show ~25% lower activity than vendor-reported values for glass microspheres. We hypothesize this discrepancy is due to bremsstrahlung ...

Novel 915 MHz Annular Phased Array Applicator for Hyperthermia Treatment of Brain Lesions

Authors: Jason Ellsworth, Mark Mishra, Jason K Molitoris, Lei Ren, Dario B. Rodrigues, Paul Turner, Graeme Woodworth

Affiliation: University of Maryland School of Medicine, Department of Neurosurgery, University of Maryland School of Medicine, University of Maryland, Department of Radiation Oncology, University of Maryland School of Medicine, Pyrexar Medical

Abstract Preview: Purpose: Hyperthermia therapy (HT) involves increasing tumor temperatures to 40-44°C and is a potent radio- and chemosensitizer for treating solid tumors. Current clinical strategies to heat deep-seat...

Optimization-Based Image Reconstruction Regularized with Inter-Spectral Structural Similarity for Limited-Angle Dual-Energy Cone-Beam CT

Authors: Chih-Wei Chang, Junbo Peng, Richard L.J. Qiu, Justin Roper, Xiangyang Tang, Tonghe Wang, Huiqiao Xie, Xiaofeng Yang, David Yu

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Emory Univ, Emory University, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Limited-angle dual-energy (DE) cone-beam CT (CBCT) is considered a promising solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, ...

Optimizing Low-Dose Imaging Parameters for Dual-Energy Cone-Beam Computed Tomography in Image-Guided Radiation Therapy

Authors: Sebastien A. Gros, Hyejoo Kang, Andrew Keeler, Luke Layman, Jason Patrick Luce, Ha Nguyen, John C. Roeske

Affiliation: Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago

Abstract Preview: Purpose:
This study aims to optimize virtual monoenergetic (VM) images obtained from dual-energy (DE) cone-beam computer tomography (CBCT) protocols for Image-Guided Radiation Therapy (IGRT). The o...

Performance of Photon Counting Detector in a Clinical PCD-CT: A Novel Image-Based Evaluation

Authors: Frank F. Dong, Megan C. Jacobsen, Ke Li, Xinming Liu, John Rong

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose: We aimed to understand the physical performance of a CdTe PCD-based detector system within a whole-body PCD-CT scanner, with the goal of optimizing its clinical application. Instead of relyin...

Photon Counting CT Method for Accurate Effective Atomic Number and Electron Density Measurement

Authors: Mohammed Alzaabi, Abderaouf Behouch, Nabil Maalej, Aamir Raja, Briya Tariq

Affiliation: Khalifa University

Abstract Preview: Purpose: Spectral Photon Counting CT (SPCCT) has emerged as a transformative technology in CT imaging capable of producing images from distinct energy windows, allowing improved material characterizat...

Photon-Counting CT for Estimation of Quantitative Information for Radiation Therapy Treatment Planning: Assessment of Scanning Conditions and Phantom Sizes

Authors: Carina Gassner, Guyue Hu, Thomas Kröncke, Christopher Kurz, Guillaume Landry, Katharina Niepel, Katia Parodi, Franka Risch, Florian Schwarz

Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t (LMU) MĂŒnchen, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t MĂŒnchen (LMU Munich)

Abstract Preview: Purpose: To evaluate the performance of a clinical photon-counting CT (PCCT) scanner in terms of proton relative stopping power (RSP) estimation using PCCT data and to compare the impact of different ...

Plastic Scintillating Detector Assisted Spot Mapping for Patient Specific Quality Assurance in Proton Beam Therapy

Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din

Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University

Abstract Preview: Purpose: This study introduces a novel approach for patient-specific quality assurance in proton beam therapy, utilizing new plastic scintillator detectors with high temporal resolutions to create det...

Predicting Reactive Oxygen Species Generated through Photoactivation of Targeted Laser Therapy in-Silico

Authors: David Alcorta, Joseph Farina, Timothy Haystead, Philip Hughes, Keshav Jha, Mark Oldham, Victoria J. P. Radosova

Affiliation: Duke University Department of Pharmacology and Cancer Biology, Medical Physics Graduate Program, Duke University, Duke University Department of Medicine, Duke University, Duke University Pharmacology and Cancer Biology, Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: This study attempts to simulate the activation of targeted photodynamic molecules using visible laser light and characterize the direct Reactive Oxygen Species (ROS) generated by Cherenkov an...

Speckle Image-Based Point Spread Function Reconstruction in Clinical Diagnostic X-Ray Systems

Authors: Jonthomas Michael Box, Isaac B. Rutel

Affiliation: University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: This study assesses the feasibility of using speckle images and a modified phase retrieval algorithm to reconstruct the point spread function (PSF) of a diagnostic x-ray system. While speckle...

Spectral CT Assessment of 3D Printing Techniques for Improving the Uniformity and Reproducibility of Models Applied in Medical Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: Filament deposition modeling (FDM) 3D printers may utilize proprietary calibration methods inadequate for medical imaging. Proper techniques are necessary to achieve imaging uniformity standa...

Spectrometry-Based Determination of X-Ray Tube Endpoint Potentials

Authors: Wesley S. Culberson, Ryan Gardner, John Thomas Stasko

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, University of Wisconsin

Abstract Preview: Purpose: X-ray tube voltage is a critical parameter in influencing an X-ray tube’s beam quality. The endpoint tube potential, the potential difference between the X-ray tube’s cathode and anode, is pa...

Streamlined Calibration of Mosfet Dosimeters for Radixact Systems: Addressing Angular Dependence and Beam Profile Challenges

Authors: Guang-Pei Chen, Renae Conlin, Juan A. Garcia-Alvarez, Kirk Morris, Haidy G. Nasief, Eenas A. Omari, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Cumulative dose limits make replacing and calibrating Metal Oxide Semiconductor Field Effect dosimeters (MOSFET-d) used for in-vivo dosimetry a common clinical task. Calibration protocols for...

Streamlining Orthovoltage QA: Feasibility of IC Profiler Dosimetry and Workflow Optimization

Authors: Huixiao Chen, Zhe (Jay) Chen, MinYoung Lee, Sameer Taneja

Affiliation: Yale School of Medicine, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: Superficial radiation therapy uses low-energy x-rays to treat various types of cancers, including non-melanoma skin cancers, and dermatological conditions such as keloid scars, mycosis fungoi...

The Z Dimension Matters: 3D Noise Power Spectrum of a Clinical Photon Counting Detector CT System

Authors: Frank F. Dong, Megan C. Jacobsen, Ke Li, Xinming Liu, Humberto Monsivais, John Rong

Affiliation: Purdue University, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To investigate the noise characteristics of a clinical photon counting detector CT (PCD-CT) system along axial and through-plane (Z) dimensions using 3D NPS measurements.
Methods: This stu...

Treatment Planning System for Uhdr Mobetron: Refinement and Validation of Phase Space Data Input

Authors: Rafael Carballeira, Tianyuan Dai, David J. Gladstone, Philip Von Voigts-Rhetz, Rongxiao Zhang

Affiliation: Shandong Cancer Hospital, Dartmouth College, IntraOp, Thayer School of Engineering, Dartmouth College, University of Missouri

Abstract Preview: Purpose: To analyze phase space (PHSP) data generated for Mobetron in FLASH radiotherapy and assess key dosimetric characteristics, including the energy spectrum, scattering angle distribution, and pe...

Two's Company, Three's a Crowd? a Bayesian Approach to Optimizing the Number of Measurement Readings in Radiation Therapy QA

Authors: Siyong Kim, Ava Paek, Joseph B. Schulz, James J. Sohn, Eric D. Stolen, Ethan D. Stolen

Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Central Florida, Virginia Commonwealth University, Department of Radiation and Cellular Oncology, University of Chicago, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: The American Association of Physicists in Medicine Task Group 142 (AAPM TG-142) guidelines recommend three measurements during monthly quality assurance to keep results within two standard de...

Universal Range Modulators for Flash Proton Therapy: 3D Printing of Stackable Variable Density Units

Authors: Eric S. Diffenderfer, Lei Dong, Alejandro Garcia, Wenbo Gu, Michele M. Kim, Alexander Lin, Kai Mei, Peter B. Noël, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: We present a novel 3D-printed range-modulating devices with spatially modulated density for FLASH particle therapy. By varying density distributions, spread-out Bragg peaks(SOBPs) can be gene...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...

Validation of a Novel Dielectric Layer-Based Detector for Linear Accelerator Quality Assurance

Authors: Dong Wook Kim, Jin Sung Kim, Dongho Lee, Sangmin Lee

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Korea, Republic of (South)

Abstract Preview: Purpose:
This study aims to analyze the characteristics of a novel detector based on a dielectric layer (Vieworks Co., Korea), which demonstrates high tolerance to high radiation doses and light tr...