Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens
Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI
Abstract Preview: Purpose:
MRI images with minimal artefacts to scan spine with Titanium instrumentation (screws, stabilizing rods, and spacer) are acquired by optimizing scanning parameters of pulse sequences (main...
Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens
Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI
Abstract Preview: Purpose:
Low-Tesla MRI (0.23T Panorama MR Scanner, Philips) has been used for tumor progression during proton therapy treatments, and for initial contouring in addition to diagnostic MRI. The pulse...
Authors: Wesley E. Bolch, Chansoo Choi, Robert Joseph Dawson, Bangho Shin, Yitian Wang
Affiliation: University of Florida
Abstract Preview: Purpose: The skeleton plays a critical role in dosimetry, containing red bone marrow (RBM) and bone endosteum (BE), which are closely linked to radiation-induced leukemia and bone cancer. While severa...
Authors: Matthew R. Hoerner, Maryam Naseri, Mena Shenouda
Affiliation: Yale University School of Medicine, Yale University
Abstract Preview: Purpose: To evaluate acquisition parameters of computed tomography (CT) scanner protocols across different machines to provide patients and clinicians consistent care and image quality, respectively.<...
Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens
Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI
Abstract Preview: Purpose:
Cone-beam computed tomography (CBCT) doses shall be limited for pediatric patients in clinical settings. Device called Filtimator (filter+collimator) was custom designed to reduce setup CB...
Authors: Tanxia Qu, Hesheng Wang
Affiliation: NYU Langone Health
Abstract Preview: Purpose:
This study, the second in a two-part series, evaluates the isocenter position (the point in 3D space minimizing the sum of Euclidean distances to the MLC's central axis) and isocenter size...
Authors: Lotem Buchbinder Shadur, Shaheen Dewji, Martin Graffigna, Alejandro Rafael Martinez, Emmanuel Mate-Kole, Antonio McClain, Samuel Taylor, Jeffrey Wang
Affiliation: Student, Nuclear and Radiological Engineering and Medical Physics Programs, Georgia Institute of Technology
Abstract Preview: Purpose: DosInMe is an internal dosimetry visualization tool developed by the Radiological Engineering, Detection, and Dosimetry Laboratory at Georgia Tech to assist researchers and professionals in v...
Authors: Amy Berrington de Gonzalez, Keith T Griffin, Jae Won Jung, Cari M Kitahara, Choonik Lee, Choonsik Lee, Aimee L McNamara, Matthew Mille, Harald Paganetti, Sergio Morato Rafet, Jan PO Schuemann, Jungwook Shin, Torunn I Yock
Affiliation: University of Michigan, East Carolina University, Massachusetts General Hospital, National Cancer Institute, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Massachusetts General Hospital and Harvard Medical School, Institute of Cancer Research
Abstract Preview: Purpose: Radiotherapy dose reconstruction enables retrospective epidemiological studies that connect late health effects to the organ-absorbed radiation doses received during treatment. Though clinica...
Authors: Daylin Barroso, Chris Beekman, Wesley E. Bolch, Natalia Estefania Carrasco-Rojas, Robert Joseph Dawson, Walter Murfee, Harald Paganetti, Andrew Robert Sforza, Julia D. Withrow
Affiliation: Massachusetts General Hospital - Harvard Medical School, Massachusetts General Hospital, University of Florida
Abstract Preview: Purpose: To develop methods for quantifying the interaction of radiation with blood in the mouse whole body (MOBY) phantom for dosimetric applications. The most important of these are modeling the dis...
Authors: Victor B. Kassey, Maciej M. Kmiec, Periannan Kuppusamy, Ryan C. O'Connell, Sergey V. Petryakov, Conner Ubert
Affiliation: Dartmouth College
Abstract Preview: Purpose: High-resolution magnetic field uniformity is essential for quantitative and pre-clinical MRI research. Imaging uniformity is affected by the B0 field, which can be corrected using manual or a...
Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Nadia M. Vassell
Affiliation: Mount Sinai Beth Israel
Abstract Preview: Purpose: Ocular HDR brachytherapy is used as an alternative treatment for eye cancer, especially with extrascleral extension in the orbit. This complex procedure inserts catheters into the orbit affix...
Authors: Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong
Affiliation: Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Gafchromic film is commonly used for quality assurance in SRS/SBRT. However, its application in low-dose measurements, such as monitoring doses on cardiac implantable electronic devices—where...
Authors: Wesley E. Bolch, Chansoo Choi, Robert Joseph Dawson, Michael Lassmann, Maikol Salas-Ramirez, Bangho Shin, Johannes Tran-Gia, Yitian Wang
Affiliation: Department of Nuclear Medicine, University Hospital Würzburg, University of Florida
Abstract Preview: Purpose: Conduct a parameterized library of mesh-type skeletal models across the lumbar vertebrae. In radiopharmaceutical dosimetry, the hematopoietic active bone marrow is typically a dose-limiting n...
Authors: Shifeng Chen, Erica Fisler, Arun Gopal, Mariana Guerrero, Jason Hendershot, Kai Huang, Eric Kusmaul, Adam Schrum, Megan Steinberg, Kai Wang
Affiliation: University of Maryland School of Medicine, Department Radiation Oncology, Kaufman Cancer Center, Upper Chesapeake Medical Center, University of Maryland Medical System Central Maryland Radiation Oncology, Department of Radiation Oncology, University of Maryland Medical Center, Baltimore Washington Medical Center Radiation Oncology, Department of Radiation Oncology, University of Maryland School of Medicine
Abstract Preview: Purpose:
Our goal is to develop and clinically deploy an automated planning tool using multicriteria optimization (MCO) for VMAT in prostate only, whole pelvis radiotherapy treatments.
Methods:<...
Authors: David Alcorta, Joseph Farina, Timothy Haystead, Philip Hughes, Keshav Jha, Mark Oldham, Victoria J. P. Radosova
Affiliation: Duke University Department of Pharmacology and Cancer Biology, Medical Physics Graduate Program, Duke University, Duke University Department of Medicine, Duke University, Duke University Pharmacology and Cancer Biology, Department of Radiation Oncology, Duke University Medical Center
Abstract Preview: Purpose: This study attempts to simulate the activation of targeted photodynamic molecules using visible laser light and characterize the direct Reactive Oxygen Species (ROS) generated by Cherenkov an...
Authors: Hyejoo Kang, Andrew Keeler, Mathias Lehmann, Jason Patrick Luce, Ha Nguyen, John C. Roeske
Affiliation: Varian Imaging Laboratory, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago
Abstract Preview: Purpose: Markerless tumor tracking (MTT) using dual-energy (DE) subtraction imaging is being considered as a non-invasive method to track tumors during lung cancer treatment. Prior to clinical impleme...
Authors: Amanda J. Deisher, Susannah V. Hickling, Shima Ito, Jon J. Kruse
Affiliation: CancerCare Manitoba, Mayo Clinic
Abstract Preview: Purpose:
To date, 11 ocular patients were treated with spot scanning gantry-based gaze-gated ocular proton program at Mayo Clinic, Rochester MN since 2023. Treatments are done in the half-arc gantr...
Authors: Jiayun Chen, Shengqi Chen, Junchao Li, Fei Liu, Jianan Wu
Affiliation: Cancer Hospital Chinese Academy of Medical Sciences, Shenzhen Center, Tongji Medical College, Huazhong University of Science & Technology, School of Electronic Engineering, Beijing University of Posts and Telecommunications, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College
Abstract Preview: Purpose: To assess if 3D Vane MRI can accurately depict the motion of the target volume and OARs.
Methods: This retrospective study included 54 liver cancer patients who underwent both 3D Vane MRI ...
Authors: Chingyun Cheng, Ben Durkee, Carri K. Glide-Hurst, Minglei Kang, Haibo Lin, Bhudatt R. Paliwal, Charles B. Simone, Zhizhen Wei, Tengda Zhang, Xingyi Zhao
Affiliation: University of Wisconsin, Department of Mechanical Engineering, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, New York Proton Center, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose: Transmission Beam (TB), Single-Energy Bragg Peak (SEBP), and Single-Energy Spread-Out Bragg Peak (SESOBP) are primary proton conformal FLASH techniques. However, each comes with significant l...