Authors: Carlo Greco, Joep Stroom, Sandra Vieira
Affiliation: Champalimaud Center for the Unknown
Abstract Preview: Purpose: RTP safety margins are generally based on geometrical uncertainties alone and not directly on clinical outcome. Here we use clinical dose-constraint data to generate dosimetric margins for OA...
Authors: Maria F. Chan, Seng Boh Gary Lim, Shih-Chi Lin, Dustin W. Lynch, Usman Mahmood, Jeonghoon Park
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: To explore the feasibility of using GafChromic LD-V1 film for annual imaging dose assessment across kV radiography, fluoroscopy, and cone beam computed tomography (CBCT) imaging protocols, as...
Authors: Yan Chu, Madison Emily Grayson, Radhe Mohan, Pablo P. Yepes
Affiliation: UT Health Science Center at Houston, Rice University, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Radiation-induced lymphopenia (RIL) is a common adverse effect of radiation therapy, negatively impacting overall survival and anti-PD1 immunotherapy efficacy. Our lab previously developed a ...
Authors: Md Mainul Abrar, Harsh Arya, Yujie Chi, Yijing Liu, Joshua Rajan, Pan Zui
Affiliation: University of Texas at Arlington, The University of Texas at Arlington, Department of Physics, University of Texas at Arlington
Abstract Preview: Purpose: Understanding the biological effects of alpha radiation at varying dose rates and energies is essential for advancing therapeutic strategies. This study demonstrates the capabilities of an in...
Authors: Humberto Monsivais, Brian A. Taylor, Francesco Versace
Affiliation: Purdue University, Department of Behavioral Science, Division of Cancer Prevention and Population Sciences, The University of Texas MD Anderson Cancer Center, Department of Imaging Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: To identify possible signatures of altered brain morphometry in nicotine-dependency via a structural covariance network approach.
Methods: Fifty-one healthy controls (HC:27M, mean age=...
Authors: E Courtney Henry, Srinivas Cheenu Kappadath, Armeen Mahvash
Affiliation: UT MD Anderson Cancer Center
Abstract Preview: Purpose:
Characterization of hepatocellular carcinoma (HCC) tumor responses for single-arm single-center prospective 90Y-radioembolization clinical trial (n=40) that used patient-specific voxel-dos...
Authors: Dan Giardina, John Karageorgiou, Chris Malone, Naganathan Mani, Allan Thomas
Affiliation: Washington University School of Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine
Abstract Preview: Purpose: Relative to planar imaging, MAA-SPECT/CT offers more reliable lung shunt fraction (LSF) and lung mean dose (LMD) estimates in 90Y radioembolization. But lung truncation in SPECT/CT can limit ...
Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Adam Leon Kesner, Cameron B. Kofler, Juan Camilo Ocampo Ramos, Yitian Wang, Stefan Wehmeier
Affiliation: University of Chicago, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson
Abstract Preview: Purpose: To develop a slice-specific computed tomography (CT) organ dose library using Monte Carlo radiation transport simulations on a newly created set of newborn, infant, and toddler computational ...
Authors: Chen-Ju Feng, Shih-Ming Hsu, Chin-Hsiung Lin, Shih-Yong Luo, Shao-Chun Tseng, Chin-Hui Wu, Ya-Ru Yang
Affiliation: National Yang Ming Chiao Tung University, Koo Foundation Sun Yat-Sen Cancer Center, Tzu-Chi University, NanoRay Biotech Co., Ltd
Abstract Preview: Purpose: The range of auger electrons in water is 2~500 nm, and its linear energy transfer reaches 26 keV/μm. This study investigated the feasibility of the auger electron radiation therapy.
Method...
Authors: Yasaman Anbari, Srinivas Cheenu Kappadath, Benjamin P. Lopez
Affiliation: University of Houston, UT MD Anderson Cancer Center
Abstract Preview: Purpose: To improve lung dosimetry for 90Y-radioembolization planning, CT-based techniques have been proposed for patient-specific lung mass estimation instead of assuming nominal 1 kg lung masses. He...
Authors: Jiayi Chen, Shaolei Li, Fuhua Yan, Yingli Yang, Jie Zhang
Affiliation: Department of Radiology, Ruijin Hospital, Institute for Medical Imaging Technology, Ruijin Hospital, Department of Radiology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Shanghai United imaging Healthcare Advanced Technology Research Institute, Department of Radiation Oncology, Ruijin Hospital
Abstract Preview: Purpose: The aim of this exploratory study is to investigate the feasibility of establishing a model to explore tissue component heterogeneity using multidimensional diffusion magnetic resonance imagi...
Authors: Weiliang Du
Affiliation: The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Winston-Lutz (WL) tests are often used to localize the radiation isocenter of a linac. The selection of gantry and collimator angles can affect the accuracy of the resulting isocenter. The ef...
Authors: Yasaman Anbari, Srinivas Cheenu Kappadath, Benjamin P. Lopez, Armeen Mahvash, Ali Yousefi
Affiliation: University of Houston, UT MD Anderson Cancer Center
Abstract Preview: Purpose: Patient-demographics-model-based liver volumetry is well-established for determining the future liver remnant following hepatectomy. We used gold-standard CT liver segmentation to validate th...
Authors: Frank F. Dong, Megan C. Jacobsen, Ke Li, Xinming Liu, John Rong
Affiliation: UT MD Anderson Cancer Center
Abstract Preview: Purpose: We aimed to understand the physical performance of a CdTe PCD-based detector system within a whole-body PCD-CT scanner, with the goal of optimizing its clinical application. Instead of relyin...
Authors: Carina Gassner, Guyue Hu, Thomas Kröncke, Christopher Kurz, Guillaume Landry, Katharina Niepel, Katia Parodi, Franka Risch, Florian Schwarz
Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)
Abstract Preview: Purpose: To evaluate the performance of a clinical photon-counting CT (PCCT) scanner in terms of proton relative stopping power (RSP) estimation using PCCT data and to compare the impact of different ...
Authors: Jeffrey S. Nelson, Raj Kumar Panta, Megan K. Russ, Ehsan Samei
Affiliation: Clinical Imaging Physics Group, Department of Radiology, Duke University Health System
Abstract Preview: Purpose: Contrast-enhanced mammography (CEM) enhances tumor detection by utilizing energy-dependent information from iodinated contrast agents. However, there is a lack of quantitative techniques to a...
Authors: Alex Lindgren-Ruby, Jeffrey M. Moirano, Joseph Everett Wishart
Affiliation: University of Washington
Abstract Preview: Purpose:
To evaluate polynomial fitting of signal intensity for signal-to-noise ratio (SNR) estimation from weekly QC ACR MRI phantom images and compare against other SNR estimation methods as well...
Authors: Naruomi Akino, Kirsten Lee Boedeker, Ilmar Hein, Akira Nishikori, Daniel W Shin
Affiliation: Canon Medical Systems Corporation, Canon Medical Research USA
Abstract Preview: Purpose: To validate a simulation tool using physics-based image quality metrics in both phantom and patient data, and to assess the low contrast detectability (LCD) of Super Resolution-Deep Learning ...
Authors: Srinivas Cheenu Kappadath, Benjamin P. Lopez, Armeen Mahvash
Affiliation: UT MD Anderson Cancer Center
Abstract Preview: Purpose: 90Y-radioembolization is utilized with curative intent. While single-compartment doses to the perfused volume for the complete pathologic necrosis (CPN) of tumors have been reported, the actu...