Search Submissions 🔎

Results for "maintaining coverage": 33 found

A Dosimetric Investigation into the Potential of Aperture-Based Techniques to Improve the Clinical Outcomes of Single-Energy Proton Bragg Peak Flash Therapy for Ocular Cancers

Authors: Arpit M. Chhabra, J Isabelle Choi, Minglei Kang, Haibo Lin, Hang Qi, Charles B. Simone, Shouyi Wei, Irini Yacoub, Francis Yu, Xingyi Zhao, Ajay Zheng

Affiliation: New York Proton Center, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose:
Pencil beam scanning (PBS) proton therapy effectively treats ocular cancer by minimizing exit doses to normal tissues. However, challenges remain in sparing nearby organs-at-risk(OARs). Ul...

A Method to Reduce Workload in Adaptive Radiotherapy

Authors: Ramesh Boggula, Lincoln Houghton

Affiliation: Karmanos Cancer Institute, Wayne State University

Abstract Preview: Purpose: To evaluate an approach that selectively applies adaptive re-planning only when needed to reduce clinical workload while maintaining treatment quality. Daily adaptive radiotherapy (ART) has t...

A Robust Quantitative Metric for Optimal Beam Selection in Radiotherapy of the Peripheral Lung Lesions: A Crucial Step in Standardization of Lung SBRT

Authors: Leslie Bell, Kai Ding, Reza Farjam, Russell K Hales, Sarah Han-Oh, Hamed Hooshangnejad, Jina Lee, K. Ranh Voong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Optimal beam arrangement is crucial in automation and standardization of thorax radiotherapy where substantial tissue heterogeneity and several critical organs at risks (OARs) exist. Here, we...

Adapting Newer Treatment Planning Strategy for Uveal Melanoma Cases Using Gamma Knife Radiosurgery

Authors: Deepak Agrawal, Subhash Gupta, Shashanksharad Kale, Gopishankar Natanasabapathi, Manoj Phalak, Dhanabalan Rajasekaran, Surendra Kumar Saini, Subramani Vellaiyan

Affiliation: All India Institute of Medical Sciences (AIIMS), All India Institute of Medical Sciences

Abstract Preview: Purpose:
To evaluate planning strategy for uveal melanoma tumor (UM) in gamma knife stereotactic radiosurgery (GKSRS) using Lightning inverse planning software for treatment planning.
Methods:

An Ultra-High Parallel Performance (UHPP) Framework for Highly Complex Radiotherapy Planning

Authors: Lu Jiang, Shusen Jing, Qihui Lyu, Dan Ruan, Ke Sheng, Qifan Xu

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California San Francisco, Department of Radiation Oncology, University of California at San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose: In radiotherapy, the conformity and compactness of dose distribution are vital to patient outcomes. The introduction of highly complex planning, such as 4π radiotherapy, has provided a system...

Automated Plan Optimization Using an Adaptive Objective Function Template in Prostate Cancer

Authors: Michael Joseph Dance, Shiva K. Das, John Dooley, David V. Fried, Spencer Lynch, Michael Repka, Shivani Sud, Neil Ari Wijetunga

Affiliation: University of North Carolina

Abstract Preview: Purpose: The growing complexity of radiation therapy treatment planning presents challenges in maintaining efficient clinical workflows while ensuring plan quality. This study evaluates the use of an ...

CBCT-Based Synthetic CT Imaging for Proton and Photon Dose Monitoring and Adaption in Supine Breast Radiotherapy

Authors: Mark E Artz, Julie Bradley, Hardev Singh Grewal, Perry B. Johnson, Christina Klassen, Raymond Mailhot Vega, Nancy Mendenhall, Jiyeon Park, Emma V. Viviers, Yawei Zhang

Affiliation: UF Health Proton Therapy Institute, University of Florida

Abstract Preview: Purpose: Verification CTs (VFCT) are used in radiotherapy to assess patient dose during treatment. However, they are time-consuming and contribute additional radiation exposure to the patient. This st...

Characterizing a VMAT Optimization Algorithm with Integrated Static-Angle Modulated Ports for Esophageal Cancer Treatment

Authors: Lei Dong, Yin Gao, Taoran Li, Michael Salerno, Boon-Keng Kevin Teo, Melissa Vila

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: A novel solution, RapidArc Dynamic-RAD (Varian Medical Systems, Palo Alto, USA) has been implemented to integrate VMAT with modulation of IMRT-like static-angle ports, including use of a dyna...

Deep Learning-Based Eye Monitoring and Tracking System for Ocular Proton Therapy in a Regular Gantry Room

Authors: David H. Abramson, Christopher Barker, Jasmine H. Francis, Meng Wei Ho, Yen-Po Lee, Haibo Lin, Hang Qi, Andy Shim, Charles B. Simone, Weihong Sun, Xiaoxuan Xu, Siyu Yang, Francis Yu, Anna Zhai

Affiliation: College of Machine Intelligence, Nankai University, New York Proton Center, Department of Biomedical Engineering, Johns Hopkins University, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Proton therapy is an effective modality for treating ocular tumors such as uveal melanoma. We developed a novel camera‐based eye‐tracking system to provide real-time noninvasive eye positioni...

Deep Learning-Based Plan Quality Prediction for Gamma Knife Radiosurgery of Brain Metastases

Authors: Chih-Wei Chang, Runyu Jiang, Mark Korpics, Yuan Shao, Aranee Sivananthan, Zhen Tian, Ralph Weichselbaum, Xiaofeng Yang, Aubrey Zhang, Xiaoman Zhang

Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Chicago, Department of Physics, University of Chicago, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University, School of Public Health, University of Illinois Chicago

Abstract Preview: Purpose: Gamma Knife (GK) plan quality can vary significantly among planners, even for cases handled by the same planner. Although plan quality metrics such as coverage, selectivity, and gradient inde...

Development of an Inverse Treatment Planning System for Precision Small Animal Radiotherapy

Authors: Zihao Liu, Qiwei Wu, Yanfei Xiong, Yidong Yang, Ning Zhao

Affiliation: Department of Engineering and Applied Physics, School of Physical Sciences, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: To develop an inverse planning framework that optimizes beam angles and intensities for small animal radiotherapy and to validate its accuracy and effectiveness.
Methods: The inverse plann...

Dosemorph: A Study on Few-Shot Learning and Dose-Anatomy Registration for Radiotherapy Optimal Dose Prediction in Cervical Cancer

Authors: Xiance Jin

Affiliation: 1st Affiliated Hospital of Wenzhou Medical University

Abstract Preview: Purpose:
Deep learning deformable registration models was proposed to predict optimal dose distributions a with a few of optimal planned doses using a few-shot learning for cervical cancer.
Meth...

Dosimetric Assessment of Simultaneous Multi-Energy and Fluence Optimization for IMRT and VMAT

Authors: Aliasghar Rohani, Rui Zhang

Affiliation: Louisiana State University, Baton Rouge, Louisiana, Department of Radiation Oncology, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: This study aimed to evaluate the impact of simultaneous optimization of multi-photon beam energy and fluence on IMRT and VMAT treatment planning.
Methods: An Elekta linear accelerator (lin...

Dosimetric Feasibility of Dominant Intraprostatic Lesion Dose Escalation in HDR Prostate Brachytherapy

Authors: Abby E. Besemer, Carolyn Eckrich, John M. Floberg, Michael J. Lawless, Jessica R. Miller, Joseph B. Schulz, Jordan M. Slagowski, Autumn E. Walter-Denzin

Affiliation: University of Wisconsin-Madison Department of Medical Physics, University of Wisconsin-Madison Department of Human Oncology, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology, Stanford University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: The aim of this treatment planning study was to evaluate the feasibility of escalating dose with HDR prostate brachytherapy to imaging-identified intraprostatic macroscopic lesions while mode...

Dosimetry Impact of Overlapping Reconstruction of CT Simulation in Stereotactic Radiosurgery Planning

Authors: Matthew Stephen Andriotty, Chi Ma, Xiao Wang, Keying (Karen) Xu, Suhong Yu, Ning J. Yue, Yin Zhang

Affiliation: Brigham and Women's Hospital, Rutgers Cancer Institute of New Jersey

Abstract Preview: Purpose: To evaluate the effects of overlapping CT reconstruction on dosimetry calculation for LINAC-based SRS patients simulated on CT simulators from three different vendors.
Methods: CT simulati...

Eclipse AFI Manual Planning Versus Brainlab Auto-Planning: A Comparison of SRS Plan Quality

Authors: Dharmin D. Desai, Ellis Lee Johnson, Philip J. Kallenberg, Kapil M. Mishra

Affiliation: Spectrum Medical Physics, University of Kentucky, Varian Advanced Oncology Solutions

Abstract Preview: Purpose: The “Ask For It” (AFI) manual optimization strategy has been shown to generate high quality SRS plans within Eclipse. The purpose of this work is to directly compare manually generated Eclips...

Evaluating Discrete Proton Arcs Converted to Pencil Beam Scanning Plans for Glioma and Chordoma in Raystation with a Mevion s250i Hyperscan Proton Therapy System

Authors: Mark A. Newpower, Jill Taylor

Affiliation: University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: RayStation 2024A allows planners to optimize intensity modulated proton therapy (IMPT) plans using discrete arcs which can then be converted to traditional pencil beam scanning (PBS) beams fo...

Feasibility and Dosimetric Impact of Intensity-Modulated Radiotherapy for Cervical Cancer Patients in Nepal: A Retrospective Analysis

Authors: Daniela Branco, John M Bryant, Surendra Bahadur Chand, Pratiksha Shahi, Joseph Weygand

Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, B.P. Koirala Memorial Cancer Hospital, , B.P Koirala Memorial Cancer Hospital, University of California San Diego / California Protons, Department of Radiation Oncology, Moffitt Cancer Center

Abstract Preview: Purpose:
Cervical cancer remains a significant health burden in Nepal, with 2169 new cases and 1313 deaths recorded in 2022. This study evaluates the feasibility of implementing step-and-shoot IMRT...

Feasibility of X-Ray Based Online Adaptive Dynamic Optimization with Integrated Knowledge-Based Planning for Head and Neck Cancer

Authors: Jacob S. Buatti, Mu-Han Lin, Dominic Moon, David D.M. Parsons, David Sher, Justin D. Visak, Hui Ju Wang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX

Abstract Preview: Purpose: Most current adaptive treatment planning systems (TPS) natively utilize static planning goals from the reference plan for online adaptive re-optimization. In complex head-and-neck cancer (HNC...

Functional Liver Image Guided Radiation Planning Using MRI with a Contrast Agent

Authors: Kenneth L. Homann, Natalie A Lockney, Hong Zhang

Affiliation: Department of Radiation Oncology, Vanderbilt University Medical Center, Vanderbilt University Medical Center

Abstract Preview: Purpose: The aim of this study is to develop a treatment planning methodology utilizing liver functional imaging via contrast-enhanced Magnetic Resonance Imaging (MRI) in patients undergoing stereotac...

Image-Guided Adaptive Proton Therapy for Head and Neck Cancer Using a Novel Gantry-Less System

Authors: Philip Blumenfeld, Jon Feldman, Yair Hillman, Michael Marash, Aron Popovtzer, Alexander Pryanichnikov, Shimshon Winograd, Marc Wygoda, Vered Zivan

Affiliation: Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), P-Cure Ltd./Inc., Sharett Institute of Oncology, Hadassah Medical Center, Hebrew University of Jerusalem

Abstract Preview: Purpose:
Image-guided adaptive proton therapy (IGAPT) allows tailored dose adjustments to account for anatomical and physiological changes during treatment. Recent efforts have developed a cost-eff...

Implementing a Knowledge-Based Planning Model for Gastrointestinal (GI) Site-Specific Plans for Photon Radiation Therapy

Authors: Andreea Dimofte, Maksym Sharma, Weibing Yang, Timothy C. Zhu

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose:
To assess the effectiveness and dosimetric impact of utilizing a knowledge-based planning model for GI site-specific plans.
Methods:
Six knowledge-based planning models were develope...

Improvements of Lateral Penumbra at Various Depth Regions in Scanned Proton Treatment System with a Multi-Leaf Collimator: Dose Verifications and Plan Comparisons

Authors: Takahiro Kato, Teiji Nishio, Masataka Oita, Robabeh Rahimi, Yuki Tominaga, Yushi Wakisaka

Affiliation: University of Maryland, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Medical Physics Laboratory, Division of Health Science, Osaka University Graduate School of Medicine, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University

Abstract Preview: Purpose: This study evaluated dose verifications and lateral penumbra improvements for scanned proton therapy plans with and without a multi-leaf collimator (MLC) under various air gaps.
Methods: E...

Investigating Pitch Factor on Plan Quality in Patients Treated with Hippocampal Avoidance Whole Brain Radiotherapy Using Volo Ultra-Optimized Helical Tomotherapy Plans

Authors: Awens Alphonse, Nebi Demez, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Gagandeep Saini, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: This study examined the impact of varying the pitch factor in hippocampal-avoidance whole-brain (HP-WB) radiotherapy treatments, utilizing the newly introduced VOLO Ultra optimization for Hel...

Multi-Center Evaluation of an AI Beam Angle Prediction Model for Liver Treatments Using Pencil Beam Scanning Proton Therapy

Authors: Christopher Ackerman, Chang Chang, Yan-Cheng Huang, Robert Kaderka, Che Lin, Hsin-Chih Lo, Iain MacEwan, Yi-Chin Tu, James Urbanic

Affiliation: University of California San DIego, Taiwan AI Labs, National Taiwan University, California Protons Cancer Therapy Center, University of Miami, Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: To investigate the performance of an existing AI beam angle prediction model on external patient datasets for liver proton treatments. The AI model was trained on datasets exclusively from on...

Optimizing Minimum Monitor Unit Thresholds for Proton Breast Therapy on the Iba Proteusone

Authors: Chia-Lung Chien, Wen C. Hsi, Faraz Kalantari, Pouya Sabouri, Man Yam

Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
Reducing treatment delivery time is critical to improving patient throughput and minimizing the risk of intrafraction motion, which can compromise treatment accuracy. This study identifies...

Optimizing Quality Assurance CT Frequency and Setup Uncertainty in Brain Proton Therapy Patients for Reduced Normal Tissue Dose

Authors: Rachel B. Ger, Heng Li, Anh Tran

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Proton therapy patients undergo quality assurance CT scans (QACTs) during treatment to verify dosimetric accuracy and utilize robustness scenarios for setup and range uncertainties. For intra...

Personalized Anisotropic Margin Strategy for Cervical Cancer Online Adaptive Radiation Therapy

Authors: Jian Chen, Qiufen Guo, Aihua Li, Jing Liu, Junjie MA, Qian WU, Haonan Xiao, Peng Xie, Xiaohui Yan, Yong Yin, Zhe Zhang

Affiliation: Department of Radiation Oncology, Peking University Shenzhen Hospital, Department of Radiation Oncology and Physics, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Obstetrics and Gynaecology, Liao Cheng People’s Hospital

Abstract Preview: Purpose: Online Adaptive radiation therapy (ART) has been an effective technique to manage patient’s inter-fractional anatomical changes and therefore reduces planning target volume (PTV). However, on...

Personalized Radiotherapy: A Novel Approach to Multi-Criteria Optimization with Patient-Specific Risk Integration

Authors: Ali Ajdari, Thomas R. Bortfeld, Zhongxing Liao, Mara Schubert, Katrin Teichert

Affiliation: The University of Texas MD Anderson Cancer Center, Department Of Radiation Oncology, Massachusetts General Hospital (MGH), Massachusetts General Hospital & Harvard Medical School, Fraunhofer ITWM

Abstract Preview: Purpose: Radiotherapy (RT) treatment planning often involves solving a multi-criteria optimization (MCO) problem. Conventionally, MCO considers a set of generic (population-wide) dosimetric criteria, ...

Proton Vs Photon Therapy for Stereotactic Arrhythmia Radioablation of Ventricular Tachycardia

Authors: Chih-Wei Chang, Kristin A Higgins, Xiaojun Jiang, Pretesh Patel, Justin R. Roper, Keyur Shah, Sibo Tian, Zhen Tian, Yinan Wang, Xiaofeng Yang, Jun Zhou

Affiliation: Department of Radiation Oncology, City of Hope Cancer Center Atlanta, Emory University, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Ventricular tachycardia (VT) is a life-threatening arrhythmia commonly treated with catheter ablation; however, some cases remain refractory to conventional treatment. Stereotactic arrhythmia...

Rectangular Aperture-Based Beam Orientation Optimization for 4π Non-Coplanar Small Animal IMRT Delivery

Authors: Dante PI Capaldi, Lu Jiang, Qihui Lyu, Ke Sheng

Affiliation: Department of Radiation Oncology, University of California at San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
Preclinical small animal studies help understand radiation-induced biological responses, toxicities, and mechanisms, facilitating the translation of new therapies to patient treatment. Int...

Scissor-Beam Based Carbon Ion Minibeam Treatment Planning Method

Authors: Hao Gao, Qiang Li, Yuting Lin, Wei Wang, Wei Wu, Weijie Zhang

Affiliation: Institute of Modern Physics, Chinese Academy of Sciences, China, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Carbon minibeam radiation therapy (cMBRT) offers high peak-to-valley dose ratio (PVDR) and relative biological effectiveness. A key challenge is balancing uniform target coverage with PVDR pr...

Utilization of Log File Analysis to Determine Deliverability of VMAT Plans As a Function of Plan Complexity

Authors: Jameson T. Baker, Sean T Grace, Cindy Pham, Michael A. Trager

Affiliation: Northwell

Abstract Preview: Purpose:
In VMAT planning, increasing complexity in MLC motion and modulation may improve dose distributions and OAR sparing while maintaining PTV coverage. However, increasing complexity can creat...