0.23T/1.5T MRI Imaging for Spine with Instrumentations

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
MRI images with minimal artefacts to scan spine with Titanium instrumentation (screws, stabilizing rods, and spacer) are acquired by optimizing scanning parameters of pulse sequences (main...

12 Year Clinical Experience with Low-Tesla MRI for Tumor Progression

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
Low-Tesla MRI (0.23T Panorama MR Scanner, Philips) has been used for tumor progression during proton therapy treatments, and for initial contouring in addition to diagnostic MRI. The pulse...

3D Wideband Late Gadolinium-Enhanced MRI for Radiotherapy of Ventricular Tachycardia: A Preliminary Study in Healthy Participants and Patient

Authors: Arash Bedayat, Jason Bradfield, Minsong Cao, Robert K Chin, Huiming Dong, J Paul Finn, Fei Han, Justin Hayase, Shu-Fu Shih, Xiaodong Zhong

Affiliation: Cardiac Electrophysiology, University of California, Los Angeles, Department of Radiation Oncology, University of California, Los Angeles, Department of Radiology, University of California, Los Angeles, Siemens Healthineers

Abstract Preview: Purpose: Cardiac SBRT is a promising treatment for ventricular tachycardia (VT). Success depends on accurate target delineation, for which 2D narrowband late gadolinium-enhanced (LGE) MRI offers valua...

A Clarification on the Bandwidth Difference Method for MRI B0 Homogeneity Assessment

Authors: Christina Brunnquell, Daniel Vergara, Joseph Everett Wishart

Affiliation: University of Minnesota, University of Washington

Abstract Preview: Purpose: To propose and validate a correction to the bandwidth difference method presented in Task Group Report No. 325 for quantifying static magnetic field homogeneity (ΔB0).
Methods: A clarifica...

A Foundational Model for Medical Imaging Modality Translation in Head and Neck Radiotherapy

Authors: Jie Deng, Yunxiang Li, Xiao Liang, Weiguo Lu, Jiacheng Xie, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Recently, foundational models trained on large datasets have shown remarkable performance across various tasks. Developing a foundational model for medical image modality translation in head-...

A Tool to Quantitatively Assess Dose after Patient Motion

Authors: Asma Amjad, Renae Conlin, Beth A. Erickson, William Hall, Eric S. Paulson, Christina M. Sarosiek

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: The adapt-to-shape (ATS) workflow on the MR-Linac involves manual contour edits followed by treatment plan reoptimization on daily pre-beam MRIs. A verification image is acquired after plan o...

AI-Based Registration-Free 3T T2-Weighted MRI Synthesis Using Truefisp MRI Acquired on a 0.35T MR-Linac System

Authors: Hilary P Bagshaw, Mark K Buyyounouski, Cynthia Fu-Yu Chuang, Yu Gao, Dimitre Hristov, Lianli Liu, Lawrie Skinner, Lei Xing

Affiliation: Department of Radiation Oncology, Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose:
MR-guided radiation therapy has introduced a significant leap in cancer treatment by allowing adaptive treatment. The low-field MR-guided system predominantly uses the TrueFISP sequence, w...

AI-Driven Drug Discovery through an Interactive Analysis of Radiomics and Biological Insights in Glioblastoma

Authors: Nobuki Imano, Yuzuha Kadooka, Daisuke Kawahara, Misato Kishi, Yuji Murakami, Shumpei Onishi

Affiliation: Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Graduate School of Biomedical and Health Sciences, Hiroshima University, Department of Neurosurgery, Hiroshima University Hospital

Abstract Preview: Purpose: Radiomics has proven useful in predicting overall survival in glioblastoma (GBM) patients, but consistent molecular correlations remain unidentified, leaving its biological basis unclear. Thi...

Adapting Newer Treatment Planning Strategy for Uveal Melanoma Cases Using Gamma Knife Radiosurgery

Authors: Deepak Agrawal, Subhash Gupta, Shashanksharad Kale, Gopishankar Natanasabapathi, Manoj Phalak, Dhanabalan Rajasekaran, Surendra Kumar Saini, Subramani Vellaiyan

Affiliation: All India Institute of Medical Sciences (AIIMS), All India Institute of Medical Sciences

Abstract Preview: Purpose:
To evaluate planning strategy for uveal melanoma tumor (UM) in gamma knife stereotactic radiosurgery (GKSRS) using Lightning inverse planning software for treatment planning.
Methods:

Addressing Missing MRI Sequences: A DL-Based Region-Focused Multi-Sequence Framework for Synthetic Image Generation

Authors: Amir Abdollahi, Oliver JĂ€kel, Maxmillian Knoll, Rakshana Murugan, Adithya Raman, Patrick Salome

Affiliation: UKHD & DKFZ, Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), German Cancer Research Centre(DKFZ), DKFZ, MGH

Abstract Preview: Purpose:
Missing MRI sequences, due to technical issues in data handling or clinical constraints like contrast agent intolerance, limit the use of medical imaging datasets in computational analysis...

An Open-Access Toolkit to Generate Realistic CT and Low-Field MR Images Based on an Xcat Phantom

Authors: Debora de Souza Antonio, Romy Guthier, Konrad Pawel Nesteruk, Erno Sajo, William Paul Segars, Gregory C. Sharp, Atchar Sudhyadhom, Hengyong Yu

Affiliation: Massachusetts General Hospital, Carl E. Ravin Advanced Imaging Laboratories and Center for Virtual Imaging Trials, Duke University Medical Center, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School,, Massachusetts General Hospital and Harvard Medical School, University of Massachusetts Lowell

Abstract Preview: Purpose: To develop an open-access toolkit for rapidly generating simultaneously realistic CT scans and low-field MR images of the abdominal region, based on patient data, while employing an XCAT phan...

Analysis of Noise Power Spectra in MR Parallel Imaging

Authors: Sulaiman D. Aldoohan, Gerardo Garcia

Affiliation: University of Toledo Medical Center

Abstract Preview: Purpose: To evaluate the noise power spectra (NPS) of images acquired using parallel imaging with varying acceleration factors in 1-D and 3-D spaces and to compare the level of the power of the noise ...

Black Bone MRI As a Surrogate for CT to Detect Intensity Differences in Mandible Sub-Volumes

Authors: Cem Dede, Clifton David Fuller, Renjie He, Laia Humbert Vidan, Stephen Y. Lai, Amy Moreno, Mohamed Naser, Kareem Abdul Wahid, Natalie A West

Affiliation: Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, Department of Head and Neck Surgery, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Head and neck cancers (HNC) treated with radiation therapy can result in radiation-induced bone injury. In CT, changes in radiodensity correlate to changes in bone integrity. Most studies use...

Brain Structural Covariance Networks in Nicotine-Dependent Users: A Graph Analysis

Authors: Humberto Monsivais, Brian A. Taylor, Francesco Versace

Affiliation: Purdue University, Department of Behavioral Science, Division of Cancer Prevention and Population Sciences, The University of Texas MD Anderson Cancer Center, Department of Imaging Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: To identify possible signatures of altered brain morphometry in nicotine-dependency via a structural covariance network approach.

Methods: Fifty-one healthy controls (HC:27M, mean age=...

Comparison of Optimized Magnetic Resonance Sequences in the Treatment Planning of Surface Brachytherapy

Authors: Ivan M. Buzurovic, Phillip M. Devlin, Evangelia Kaza, Michael John Lavelle

Affiliation: Department of Radiation Oncology, Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology

Abstract Preview: Purpose: Recent work in surface brachytherapy (SBT) has demonstrated the feasibility of using magnetic resonance (MR)-guidance in place of Computer Tomography (CT) in SBT planning. The purpose of this...

Decoupling Cardiorespiratory Motion of Cardiac Substructures Via 5D-MRI for Radiotherapy

Authors: Carri K. Glide-Hurst, Thomas M Grist, Kevin M. Johnson, Prashant Nagpal, Tarun Naren, Chase Ruff, Oliver Wieben, Jiwei Zhao

Affiliation: Department of Biostatistics and Medical Informatics, University of Wisconsin - Madison, Department of Radiology, University of Wisconsin-Madison, Department of Medical Physics, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison

Abstract Preview: Purpose: Cardiotoxicity is a devastating side effect for thoracic radiotherapy (RT). Currently, standard RT imaging is insufficient to decouple cardiorespiratory motion, limiting substructure-specific...

Deep Learning-Driven Comparative Analysis of CNN-Based Architectures and High-Order Vision Mamba U-Net (H-vMUNet) for MRI-Based Brain Tumor Segmentation

Authors: Sang Hee Ahn, Nalee Kim, Do Hoon Lim

Affiliation: Samsung Medical Center, Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine

Abstract Preview: Purpose: MRI offers superior soft-tissue contrast, aiding tumor localization and segmentation in radiation therapy, which traditionally relies on oncologists' expertise. This study compares CNN-based ...

Demystifying Magnetic Resonance Imaging: Targeted Educational Initiatives for Medical Physicists in TĂŒrkiye and Preclinical Medical Students in the United States

Authors: Samuel A. Einstein, Jesutofunmi Fajemisin, Evren O. Göksel, Görkem O. GĂŒngör, Marthony Robins, Travis C. Salzillo, Charles R. Thomas, Turgay Toksay, Joseph Weygand, Yue Yan

Affiliation: Acibadem MAA University, Department of Radiation Oncology and Applied Science, Dartmouth Health, Dartmouth College, Moffitt Cancer Center, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Penn State College of Medicine, Bursa Ali Osman Sönmez Oncology Hospital

Abstract Preview: Purpose: Magnetic resonance imaging (MRI) is an indispensable clinical tool, offering unparalleled soft tissue contrast critical for diagnosing and managing a wide range of conditions. However, its co...

Development and Validation of an MR-Compatible Anthropomorphic Motion Phantom for Liver Motion Assessment and MR-Linac Gating System Optimization

Authors: Tsuicheng D. Chiu, Weiguo Lu, Aaron Thomlinson, You Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose: To develop and validate an MR-compatible anthropomorphic motion phantom to assess liver motion, real-time dosimetry, and gating system performance under controlled and reproducible respirator...

Development of Foundation Model for Analysis of Prostate Cancer with Mpmri

Authors: Ahmad Algohary, Adrian Breto, Quadre Emery, Radka Stoyanova

Affiliation: University of Miami, Department of Radiation Oncology, University of Miami

Abstract Preview: Purpose:
To develop a foundation model (U-Found) for multiparametric MRI (mpMRI) of the prostate by using self-supervised learning to prove the feasibility of a prostate-oriented foundation model u...

Development of an Ultrafast MR Technique to Detect Linac Radiation Pulses for Biological Imaging on a Clinical 0.35T MR-Linac

Authors: Pierre Gardair, Johnathan E Leeman, Claire Keun Sun Park, Atchar Sudhyadhom

Affiliation: Brigham and Women’s Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School,, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School, Harvard Medical School

Abstract Preview: Purpose: Dose is a poor surrogate for radiobiological damage but no in vivo technology exists to directly measure damage such as DNA strand breaks and free radical generation (FRG). Recent advances in...

Dose Dependent White Matter Injuries Quantified By Axial and Radial Diffusivity of Diffusion Tensor Imaging Significantly Correlate with Radiation-Induced Neurocognitive Decline in Diffuse Glioma Patients Underwent Chemoradiation Therapy

Authors: Robert Fucetola, Jiayi Huang, Zhihua Liu, Chongliang Luo, Tong Zhu

Affiliation: Washington University School of Medicine, Washington University in St. Louis, School of Medicine

Abstract Preview: Purpose:
This prospective observational study investigates radiation-induced white matter (WM) injuries using longitudinal diffusion tensor imaging (DTI) in patients with diffuse glioma following r...

Enhancing Urethral Visualization for Prostate SBRT Using Post-Void T2-Weighted Imaging on a Low-Field 0.35T MR-Linac System

Authors: Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: Accurate delineation of the urethra is critical for optimizing tumor control and minimizing urethral toxicity in prostate stereotactic body radiation therapy (SBRT). The purpose of this study...

Evaluation of Deformable Image Registration Accuracy Used in MR-Only Ventilation Mapping

Authors: Fei Han, James M. Lamb, Michael Vincent Lauria, Daniel A. Low, Tessa Elizabeth Maurer, Danilo Maziero, Claudia R. Miller, Drew Moghanaki, Louise Naumann, Nicolas Viot

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, Siemens Healthineers, UCLA, University of California Los Angeles

Abstract Preview: Purpose: Patients with lung disease outside radiotherapy are barred from high dose protocols used for motion modeling, but MRI could offer no-dose alternatives. Image-based ventilation is a promising ...

Evaluation of MR Proton Density Fat Fraction (PDFF) for Bone Marrow Protection in RT

Authors: Li Tong, Chuyan Wang, Zhengkui Wang, Yingli Yang, Jie Zhang

Affiliation: Shanghai United imaging Healthcare Advanced Technology Research Institute, Shanghai United Imaging Healthcare Co., LTD, Department of Radiology, Ruijin Hospital, Institute for Medical Imaging Technology, Ruijin Hospital

Abstract Preview: Purpose:
Pelvic radiotherapy (RT)-induced bone marrow (BM) damage affects patient prognosis by causing hematologic toxicity. However, consensus on BM-sparing (BMS) RT is still lacking, owing to the...

Evaluation of Synaptive MRI Geometric Distortion with Sun Nuclear MR Distortion and Image Fusion Head Phantom

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Jing Feng, Wenzheng Feng, Joseph Hanley, Jeff Stainsby, Tingyu Wang

Affiliation: Synaptive Medical, Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose:
The Synaptive MRI is a 0.5T superconducting head only system (first US install 2023). This is the first study that evaluates the geometric accuracy using a Sun Nuclear MR Distortion and Im...

Exploiting the Glycerol CH2 Resonances for Estimating Relative Free Fatty Acid to Triglyceride Concentration Ratios

Authors: José Antonio Klautau Toffoli, Anthony G. Tessier, Atiyah Yahya

Affiliation: Department of Oncology, University of Alberta

Abstract Preview: Purpose: To demonstrate that magnetic resonance spectroscopy (MRS) methyl (≈0.9 ppm) to glycerol (≈4.1-4.3 ppm) resonance area ratios correlate with relative concentrations of free fatty acids to trig...

From Noisy Signals to Accurate Maps: Transforming Look-Locker MRI with an Intelligent T₁ Estimation

Authors: Prabhu C. Acharya, Hassan Bagher-Ebadian, Stephen L. Brown, James R. Ewing, Mohammad M. Ghassemi, Benjamin Movsas, Farzan Siddiqui, Kundan S Thind

Affiliation: Michigan State University, Oakland University, Henry Ford Health

Abstract Preview: Purpose: Accurate T1 quantification using T One by Multiple Read Out Pulse (TOMROP) sequences is essential for physiological assessments in dynamic-contrast-enhanced (DCE) MRI and T1 mapping studies. ...

Generalized 2D Cine Multi-Modal MRI-Based Dynamic Volumetric Reconstruction Using Motion-Aligned Implicit Neural Network with Spatial Prior Embedding

Authors: Ming Chao, Karyn A Goodman, Yang Lei, Tian Liu, Jing Wang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose: Real-time volumetric MRI is essential for motion management in MRI-guided radiotherapy (MRIgRT), yet acquiring high-quality 3D images remains challenging due to time constraints and motion ar...

Generating 3D Brain in Volume (BRAVO) Images Using Attention-Gated Conditional Gan (AGC-GAN)

Authors: Nan Li, Shouping Xu, Gaolong Zhang, Xuerong Zhang

Affiliation: Department of Radiation Oncology, HeBei YiZhou proton center, School of Physics, Beihang University, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose:
The 3D BRAVO sequence is an advanced magnetic resonance (MR) technique that allows for image reconstruction at any angle. It offers 1 mm gapless scanning and has a high signal-to-noise rat...

Immobilization and Optimization of Pulse Sequences for 0.23T MRI

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
It has been challenging to acquire clinically useful MR images of pediatric cancer patients without anesthesia, and MR contrast agents. Custom-made immobilization devices and optimization ...

Impact of Respiratory Motion and MRI Sequences on Tumour Volume Determination in MR-Guided Radiotherapy

Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wa Kong, Pei-Xiong Li, Pak Hang Nam, Bin Yang, Siu Ki Yu, Chi To Yung

Affiliation: Medical Physics Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose:
The Elekta Unity system facilitates daily adaptive radiotherapy using MRI-based treatment planning. However, MR images are prone to motion artefacts caused by respiratory motion, potential...

Improvement of Spine Phantom for MR Imaging of the Spine

Authors: Richard Dortch, Thammathida Ketsiri, Zhiqiang Li, Shiv P. Srivastava

Affiliation: Barrow Neurological Institute, Dignity Health Cancer Institute, St. Joseph's Hospital & Medical Center

Abstract Preview: Purpose: Imaging the spinal cord post-surgery is challenging due to metal surgical implants, which induce signal loss and geometric distortions. Together, this hinders the visualization of the spinal ...

Improving 4D-MRI Parameters for Abdominal Tumor Motion Management: A Phantom Study

Authors: Morgan Aire, Krystal M. Kirby, Olivia Magneson, David E. Solis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: For soft-tissue abdominal tumors, a 4D-MR may provide improved tumor tracking over the clinical standard 4D-CT. This project aims to optimize a clinically available 4D-MR pulse sequence to ac...

Investigating the Use of a DWI Phantom for Routine QA of an MR-Linac at Room Temperature

Authors: Nicholas Carlson, Joel J. St-Aubin

Affiliation: University of Iowa Hospitals and Clinics, University of Iowa

Abstract Preview: Purpose: To establish baselines metrics and determine longitudinal accuracy and reproducibility of Diffusion-Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) values for a 1.5T Elekta Un...

Multi-Vendor Validation of a Deep Learning-Based Synthetic CT Generation Model for MR-Only Radiotherapy Planning in the Pelvis

Authors: Gregory Bolard, Rabten Datsang, Sarah Ghandour, Timo Kiljunen, Pauliina Paavilainen, Sami Suilamo, Katlin Tiigi

Affiliation: Turku University Hospital, Virginia Commonwealth University, MVision AI, North Estonia Medical Centre, Docrates Cancer Center, Hopital Riviera-Chablais

Abstract Preview: Purpose: To verify the performance of a vendor-neutral deep learning model for synthetic CT generation from T2-weighted and balanced steady-state MR sequences to support both MR-only simulation and MR...

Multidimensional Diffusion MRI Based Microstructural Heterogeneity Model on a 5T MR System

Authors: Jiayi Chen, Shaolei Li, Fuhua Yan, Yingli Yang, Jie Zhang

Affiliation: Department of Radiology, Ruijin Hospital, Institute for Medical Imaging Technology, Ruijin Hospital, Department of Radiology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Shanghai United imaging Healthcare Advanced Technology Research Institute, Department of Radiation Oncology, Ruijin Hospital

Abstract Preview: Purpose: The aim of this exploratory study is to investigate the feasibility of establishing a model to explore tissue component heterogeneity using multidimensional diffusion magnetic resonance imagi...

Next Generation Nanoparticles for Fractionated MRI-Guided Radiation Therapy

Authors: Stephanie Bennett, Ross I. Berbeco, Guillaume Bort, Needa Brown, Lena Carmes, Sandrine Dufort, Michael John Lavelle, Geraldine Le Duc, Francois Lux, Toby Morris, Zeinaf Muradova, Andrea Protti, Olivier Tillement

Affiliation: University de Lyon, NH TherAGuIX, University of Massachsetts Lowell and Dana-Farber Cancer Institute Boston, Department of Radiation & Cellular Oncology, University of Chicago, University of Central Florida, Department of Radiation Oncology, Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, NH TherAguix, Universite de Lyon, Brigham and Women's Hospital, Dana-Farber Cancer Institute

Abstract Preview: Purpose: AGuIX is a theranostic Gd-based nanoparticle currently under phase-2 clinical testing where patients receive 2-3 doses at 1-week intervals prior to imaging and irradiation. AGuIX-Bi is a new ...

Novel Automatic Detection of Surface Brachytherapy Applicators and Catheters on Vibe MR Images

Authors: Ivan M. Buzurovic, Evangelia Kaza

Affiliation: Department of Radiation Oncology, Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology

Abstract Preview: Purpose: Recent advances allow for depiction of surface brachytherapy flap applicators using MRI, with empty catheters detected by signal intensity reduction. As manual catheter detection is subjectiv...

Optimized Dosimetric Planning for Trigeminal Neuralgia Using Cyberknife S7 Precision TPS with Volo Optimizer

Authors: Amy Fitzpatrick, Kim Howard, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: This study evaluates the dosimetric advantages and workflow improvements of the CyberKnife S7 Precision Treatment Planning System (TPS) with the VOLO optimizer for stereotactic radiosurgery (...

Patient-Specific Imaging Modality Agnostic Virtual Digital Twins Modeling Temporally Varying Digestive Motion

Authors: James M. Balter, Lando S. Bosma, Jorge Tapias Gomez, Nishant Nadkarni, Mert R Sanbuncu, William Paul Segars, Ergys D. Subashi, Neelam Tyagi, Harini Veeraraghavan

Affiliation: University of Michigan, The University of Texas MD Anderson Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Carl E. Ravin Advanced Imaging Laboratories and Center for Virtual Imaging Trials, Duke University Medical Center, Cornell University, University Medical Center Utrecht, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Develop patient-specific virtual digital twin (VDT) cohorts modeling physically realistic spatio-temporal gastrointestinal (GI) organs (stomach and duodenum) digestive motion.
Methods: Pat...

Radiomics Changes in MR Images of Prostate and Dominant Intra-Prostate Lesions during SBRT on MR-Linac

Authors: David L. Barbee, David Byun, Ting Chen, Paulina E. Galavis, Siming Lu, Sarah Rosemary Morris, Hesheng Wang, Michael J Zelefsky

Affiliation: NYU Langone Health

Abstract Preview: Purpose: MR-Linac enables dose escalation in prostate SBRT on accurately defined dominant intra-prostate lesion (DIL) on daily MR images. This study aims to evaluate inter-fraction changes in the radi...

Repeatability of Quantitative 3D T1ρ Imaging in Head and Neck Cancer

Authors: Sandeep Panwar Jogi, Nancy Lee, Ricardo Otazo, Ramesh Paudyal, Qi Peng, Akash Shah, Amita Shukla-Dave, Can Wu

Affiliation: Department of Radiology, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiology, Albert Einstein College of Medicine and Montefiore Medical Center

Abstract Preview: Purpose: Quantitative T1ρ imaging provides enhanced tissue characterization beyond standard T1 and T2 parameters, potentially supporting early-stage longitudinal monitoring of head and neck cancer. Th...

Robust Estimation of Cell Microstructure Parameters Via Diffusion MRI Cytometry

Authors: Yan Dai, Jie Deng, Xun Jia, Wen Li

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Cell microstructure information is critical for radiotherapy response assessment. Diffusion MRI (dMRI) offers great potential in deriving cell parameters. Yet parameters estimated in existing...

Sources of Magnetic Susceptibility Artifacts in MR Imaging of the Jaw and Facial Nerves

Authors: Avneesh Chhabra, Zhiyue J. Wang, Qing Yuan

Affiliation: University of Texas Southwestern Medical Center

Abstract Preview: Purpose: Magnetic susceptibility artifacts from dental arches and hardware often compromise MRI neurography of jaw and facial nerves. This study aims to characterize these artifacts and provide insigh...

Standardized MRI-CT Hybrid Workflow for High-Dose-Rate Image-Guided Adaptive Brachytherapy in Cervical Cancer: Aapm TG-303 Implementation

Authors: Kim Creach, Kim Howard, Julius G. Ojwang, Richard A. Shaw, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: To present a standardized MRI-CT hybrid workflow for High-Dose-Rate (HDR) Image-Guided Adaptive Brachytherapy (IGBT) in cervical cancer, aligned with AAPM TG-303, as a model to assist with im...

Study of PSMA-PET/MR Biomarkers for Prostate Stereotactic Radiotherapy Planning

Authors: Guillermo Daniel Alvarez, Daniel Fino, Rocio Luz Gilli, Dorian Alexander Romero

Affiliation: School Foundation of Nuclear Medicine, INTECNUS Foundation, Nuclear Medicine and Radiotherapy Center of Southern Patagonia

Abstract Preview: Purpose: To evaluate the anatomical, functional, and molecular information from PET/MR images with F18-PSMA to identify intraprostatic lesions and delineate a boost in stereotactic body radiotherapy (...

Teaching an Old Dog New Tricks: Unlocking Hidden Potential in Existing Frameworks for Versatile Radiotherapy Applications

Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Kangning Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose:
This work demonstrates how existing software, when creatively adapted, can address a wide range of clinical challenges. By focusing on data exploration and application-specific modificatio...

Towards Penile Small Vessel Imaging with Ferumoxytol-Enhanced MRI

Authors: Darren Fang, Amar Kishan, Justin McWilliams, Dan Ruan, Xiaodong Zhong

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, Department of Radiology, University of California, Los Angeles, Department of Radiological Sciences, University of California, Los Angeles

Abstract Preview: Purpose: Prostate radiotherapy can malform penile vasculature, contributing to erectile dysfunction and compromising quality of life. To detect, quantify, and preferably avoid such occurrences, this p...

Use of Edge-Driven Modified Fuzzy C-Means Algorithm in DCE-MRI Image Sequences for Prostate Cancer Lesion Segmentation

Authors: Ilias Gatos, Stavros Grigoriadis, George C. Kagadis, Maria Karamesini, Paraskevi Katsakiori, Dimitris N. Mihailidis, Stavros Spiliopoulos, Efstratios Syrmas, Ioannis Theotokas, Stavros Tsantis, Pavlos Zoumpoulis

Affiliation: Diagnostic Echotomography, University of Pennsylvania, University of Athens, University of Patras

Abstract Preview: Purpose: To detect prostate lesions on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) images which is a particularly difficult task due to the heterogeneous and inconsistent representa...

Using Multiple Sequences MRI for Synthesizing CT Based on a Deep Learning Approach

Authors: Jie Hu, Nan Li, Chuanbin Xie, Shouping Xu, Xinlei Xu, Gaolong Zhang, Zhilei Zhang

Affiliation: School of Physics, Beihang University, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, the First Medical Center of the People's Liberation Army General Hospital, National Cancer Center/ National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, PeopleÊŒs Republic of China, Department of Radiation Oncology, School of Physics, Beihang University, Beijing, 102206, PeopleÊŒs Republic of China

Abstract Preview: Purpose: This study aims to synthesize CT images for MRI-only radiation therapy using a deep learning approach that integrates information from the T1- and T2-weighted MRI sequence.
Methods: 97 hea...

Validation of an Ivim Tool for Liver Hypoxia Assessment for an Online Adaptive MR-Linac System

Authors: Jean-Pierre Bissonnette, Catherine Coolens, Laura Dawson, Ryan A Kuhn, Michael Maddalena, Teo Stanescu

Affiliation: Princess Margaret Hospital, The Princess Margaret Cancer Centre - UHN, University of Toronto, Princess Margaret Cancer Centre

Abstract Preview: Purpose: To investigate the generation and reproducibility of 3D hypoxia maps in liver hepatocellular carcinoma (HCC) patients using data derived from an Intravoxel Incoherent Motion (IVIM) MR sequenc...