Search Submissions πŸ”Ž

Results for "number arcs": 14 found

3D Renal Microdosimetry: Evaluating Radiopharmaceuticals Using Histology-Based 3D Models

Authors: John P. Aris, Wesley E. Bolch, Madison Bushloper, Lauren E Ellis, Adam Grey Haneberg, Elizabeth Martin, Bonnie N. C. President, Andrew Robert Sforza, Alexander Zorrilla

Affiliation: Johns Hopkins University, Biomedical Engineering, University of Florida

Abstract Preview: Purpose: To develop six additional high-fidelity 3D models of kidney renal cortical labyrinth from H&E-stained histology slides to support radiation dosimetry in radiopharmaceutical therapies (RPTs).<...

A Novel Lattice Technique Based Spot Scanning Proton Arc Therapy Via Spot Sparsity Optimization and LET Optimization

Authors: Zhitao Dai, Riao Dao, Xuanfeng Ding, Qingkun Fan, Yajun Jia, Gang Liu, Gang Peng, Yujia Qian, Hong Quan, Kunyu Yang, Sheng Zhang, Lewei Zhao

Affiliation: Department of Radiation Oncology, Stanford University, Corewellhealth William Beaumont University Hospital, School of Mathematics and Statistics, Wuhan University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Chinese Academy of Medical Sciences Cancer Hospital Shenzhen Hospital, School of Physics and Technology,Wuhan University, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: Lattice radiation therapy (LRT) is an innovative three-dimensional(3D) implementation type of spatially fractionated radiation therapy (SFRT). This study aims to develop a novel spot-scanning...

A Quantitative Analysis of Hypersight CBCT Image Quality Using a Phantom-Based Approach Under Different Scatter Conditions

Authors: Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Fang Li, Noor Mail, Joseph Shields, Christopher Tyerech

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, University of Pennsylvania, UPMC

Abstract Preview: Purpose: HyperSight is a new platform for image-guided radiation therapy, offering advanced reconstruction algorithms, a large field-of-view, and rapid acquisition times. To validate the performance o...

Comparative Evaluation of Dosimetric Treatment Plan Quality for Truebeam, and Tomotherapy in Spatially Fractionated Radiation Therapy

Authors: Raghavendiran Boopathy, Mansoor Khan, Srinidhi Rajagopalan

Affiliation: University of Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: This study aims to evaluate and compare the dosimetric outcomes of spatially fractionated radiotherapy (SFRT) grid planning techniques using Varian Eclipse for a Varian Edge C-arm LINAC syste...

Direct-to-Unit Dose Calculations for Stereotactic Radiosurgery on a C-Arm Linac with Modern on-Board Imaging Solutions

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Haley K Perlow, Alex T. Price, Atefeh Rezaei, Prashant Vempati, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: The HyperSight imaging feature on C-arm linacs(HS-CBCT) offers increased CT number accuracy over conventional on-board imaging. The C-arm geometry allows for noncoplanar treatments common to ...

Dosimetric Variations Induced By Inaccurate Collimator Angles in Single-Isocenter SRS Plan for Multi-Lesion Brain Metastases

Authors: Makunda Aryal, Gregory Bartlett, David D. Campos, Ke Colin Huang, Sook Kien Ng, Christopher F. Njeh, Oluwaseyi Oderinde, Edwin Quashie, Ashok Tiwari, Yong Yue

Affiliation: Purdue University, Department of Radiation Oncology, Indiana University, Indiana University, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose:
Linear accelerator-based single-isocenter Stereotactic Radiosurgery (SRS) is widely used for treating brain metastases due to its efficiency, reduced treatment time, and lower imaging dose...

Eclipse AFI Manual Planning Versus Brainlab Auto-Planning: A Comparison of SRS Plan Quality

Authors: Dharmin D. Desai, Ellis Lee Johnson, Philip J. Kallenberg, Kapil M. Mishra

Affiliation: Spectrum Medical Physics, University of Kentucky, Varian Advanced Oncology Solutions

Abstract Preview: Purpose: The β€œAsk For It” (AFI) manual optimization strategy has been shown to generate high quality SRS plans within Eclipse. The purpose of this work is to directly compare manually generated Eclips...

Enhancing Dose Conformity in Halcyon SRS Plans: A Novel Approach Using Optimized Collimator Angles and Sub-Arcs.

Authors: David Chighvinadze, Chieh-Wen Liu, Sugandima Weragoda, Ping Xia

Affiliation: Cleveland Clinic Sandusky, Cleveland Clinic

Abstract Preview: Purpose: To explore the feasibility of using coplanar beams with collimator angle optimization for brain SRS plans with Halcyon system.
Methods: This study used a dataset of 26 patients with 2-3 br...

Evaluating Discrete Proton Arcs Converted to Pencil Beam Scanning Plans for Glioma and Chordoma in Raystation with a Mevion s250i Hyperscan Proton Therapy System

Authors: Mark A. Newpower, Jill Taylor

Affiliation: University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: RayStation 2024A allows planners to optimize intensity modulated proton therapy (IMPT) plans using discrete arcs which can then be converted to traditional pencil beam scanning (PBS) beams fo...

Evaluating a Novel Solution for GYN Planning: Integrated Dynamic Collimator Rotation and Static Angle Modulated Ports with a New Optimizer

Authors: Ben Archibald-Heeren, Grace Gwe-Ya Kim, Kelly Kisling, Xenia Ray

Affiliation: UC San Diego, Icon Cancer Centres, University of California, San Diego, University of California San Diego

Abstract Preview: Purpose: To evaluate improvements in external beam plans for gynecological cancers from a novel planning solution: RapidArc Dynamic (RAD) (Varian Medical Systems, Palo Alto, CA) which optimizes VMAT w...

Flash Radiation Spares Reproductive Capability in Adult C. Elegans

Authors: Barry Andricks, Stratton Black, Scott R. Floyd, Ashutosh Kotwal, Eric L. Martin, Stepan Mikhailov, Mark Oldham, Niccolo Terrando, Andrew Thompson, Ying Wu

Affiliation: Department of Physics, Duke University, Medical Physics Graduate Program, Duke University, Duke University, Department of Radiation Oncology, Duke University Medical Center, Triangle Universities Nuclear Laboratory

Abstract Preview: Purpose: To evaluate and quantify the effects of high energy electron radiation delivered at FLASH and conventional dose rates on the reproductive capability of adult C. elegans nematodes.
Methods:...

Impact of Arc Number Variation on VMAT Lattice Radiotherapy Plans

Authors: Minbin Chen, Gang Liu, Manju Liu, Weiwei Sang, Pulin Sun, Mingyuan Ye, Fang-Fang Yin, Lihua Zhang, Haiming Zhu

Affiliation: Jiahui International Hospital, Radiation Oncology, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University, Duke Kunshan University, The First People's Hospital of Kunshan

Abstract Preview: Purpose: This study aims to evaluate the effects of varying the number of arcs on treatment plans created using Volumetric Modulated Arc Therapy (VMAT) for Lattice radiotherapy (LRT).
Methods: Thre...

Introduce a Novel Spot-Scanning Proton Arc(SPArc) Optimization Algorithm for Single Energy Extraction(SEE) Synchrotron-Accelerator-Based Proton Therapy System (PTS)

Authors: Xiaoda Cong, Xuanfeng Ding, Gang Liu, Peilin Liu, Jiajian Shen

Affiliation: Department of Radiation Oncology, Mayo Clinic, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Corewellhealth William Beaumont University Hospital

Abstract Preview: Purpose: This study aims to develop the first SPArc optimization algorithm based on the Dynamic Programming (SPArc-DP), to improve the treatment delivery efficiency for synchrotron-accelerator-based P...

Isocenter Optimization for Linear Accelerator-Based Radiosurgical Treatment Planning for Multiple Brain Metastases

Authors: J. Daniel Bourland, Christina K Cramer, Justin M. Napolitano, James D. Ververs

Affiliation: Wake Forest University School of Medicine

Abstract Preview: Purpose:
Brain metastases (BM) can be treated with linear accelerator (LINAC)-based stereotactic radiosurgery (SRS). Treatment planning for this modality has evolved over time; treatment plans typi...