Search Submissions 🔎

Results for "number electron": 25 found

3D Renal Microdosimetry: Evaluating Radiopharmaceuticals Using Histology-Based 3D Models

Authors: John P. Aris, Wesley E. Bolch, Madison Bushloper, Lauren E Ellis, Adam Grey Haneberg, Elizabeth Martin, Bonnie N. C. President, Andrew Robert Sforza, Alexander Zorrilla

Affiliation: Johns Hopkins University, Biomedical Engineering, University of Florida

Abstract Preview: Purpose: To develop six additional high-fidelity 3D models of kidney renal cortical labyrinth from H&E-stained histology slides to support radiation dosimetry in radiopharmaceutical therapies (RPTs).<...

A Refined Model of Reference Mesh-Type Female Breast Model Vasculature and Glandular Structures for Internal Circulating Lymphocyte Dosimetry

Authors: Wesley E. Bolch, Carlos G. Colon-Ortiz, Robert Joseph Dawson, Lazaro Fuentes Alfonso, Shreya P. Pathak, Julia D. Withrow

Affiliation: University of Florida

Abstract Preview: Purpose: To develop tetrahedral mesh-based tissue models within the breasts of the International Commission on Radiological Protection (ICRP) adult female mesh-type reference computational phantom (AF...

Absorption and Material Property Characteristics of 3D-Printing Filaments Based on Monte-Carlo Simulations and Spectral Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: 3D printing has the potential for producing materials useful for the imaging field. This work aims to identify absorption (attenuation coefficient) and material properties (effective atomic n...

An End-to-End Test for Adaptive Radiotherapy with Varian Hypersight CBCT Imaging System Using Radiochromic Film in a Rando Pelvis Phantom

Authors: Jameson T. Baker, Yijian Cao, Jenghwa Chang, Sean T Grace, Lyu Huang, Jian Liu, Echezona Simon Obi, Anurag Sharma

Affiliation: Northwell, Hofstra University Medical Physics Program

Abstract Preview: Purpose:
To validate the end-to-end dosimetrical accuracy of Varian HyperSight CBCT for adaptive radiotherapy (ART), from simulation to dose delivery, using radiochromic film dosimetry in a Rando p...

Assessment of the Radiological Features of 3D-Printed Polylactic Acid Composites for Creating Personalized Dosimetric Phantoms

Authors: Ashish Binjola, Raj Kishore Bisht, Natanasabapathi Gopishankar, Pratik Kumar, Daya Nand Kishore Sharma, Sukhvir Kishore Singh, Subramani Vellaiyan

Affiliation: Medical Physics Unit, All India Institute of Medical Sciences, All India Institute of Medical Sciences, Department of Radiological Safety, Institute of Nuclear Medicine and Allied Sciences, Department of Radiation Oncology, All India Institute of Medical Sciences

Abstract Preview: Purpose: Additive manufacturing is increasingly being explored to create dosimetry phantoms. Commercial anthropomorphic phantoms represent an average patient and lack anatomical variations due to obes...

Can Contrast Scans of Dual-Layer Detector Spectral CT be Directly Used for Proton Dose Calculations?

Authors: Wen C. Hsi, Pouya Sabouri, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
Traditional single-energy CT (SECT) contrast scans cannot be used for proton dose calculations due to significantly higher HU caused by iodine. Dual-layer dual-energy CT (DL-DECT) can dire...

Compact Representation of External Beam Photon Phase Space Data Via Implicit Neural Representation Learning

Authors: Serdar Charyyev, Cynthia Fu-Yu Chuang, Veng Jean Heng, Lianli Liu, Lei Xing, Yong Yang

Affiliation: Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose: To replace large finite-size photon phase space files with a compact neural network capable of generating an infinite number of particles.
Methods: Three separate models were developed to ...

Cross-Calibration and Comparison of CT Number to Electron Density Using Two Calibration Phantoms

Authors: Afrouz Ataei, Xinhui Duan, Andrew R. Godley, Mi-Ae Park, Mahbubur Rahman, Liqiang Ren, Chenyang Shen, Gary Xu

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose:
Electron density (ED) phantoms are crucial for calibrating CT number (HU) to relative ED in treatment planning. This study evaluates the differences in HU-to-ED calibrations between two co...

Cross-Calibration of CT Number to Electron and Physical Density: Feasibility of Using Diagnostic Scans for Treatment Planning

Authors: Afrouz Ataei, Andrew R. Godley, Mi-Ae Park, Mahbubur Rahman, Liqiang Ren, Chenyang Shen, Gary Xu

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose: Even though many patients undergo diagnostic CT scans prior to treatment, simulation CT scans are commonly required for treatment planning. This study evaluates whether prior diagnostic CT sc...

Determining the Optimal CT Tube Voltage for Imaging Bone Structures in Radiotherapy.

Authors: Mohamed Bahaaeldin Mohamed Afifi, Nahla Nagy Ahmad Ataalla, Ahmed A. Eldib

Affiliation: Fox Chase Cancer Center, Radiological Sciences and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University.

Abstract Preview: Purpose: Optimizing CT imaging parameters is crucial for balancing radiation dose, contrast resolution, and accurate Hounsfield unit representation, particularly in radiotherapy treatment planning. Th...

Efficient Monte Carlo Simulation of Radiation-Induced Double Strand Break Production and Repair Kinetics

Authors: Zakaria Aboulbanine, Greeshma A. Agasthya, Paul Inman, Anuj J. Kapadia, Anthony Hong Cheol Lim, Jayasai Ram Rajagopal, Chris C. Wang

Affiliation: Oak Ridge National Laboratory, Georgia Institute of Technology

Abstract Preview: Purpose: Radiobiological simulation via TOPAS-nBio requires significant computational resources and time to provide meaningful results. This study aims to decrease simulation time and computational re...

Establishing a Conventional Linac-Based Electron Flash Beam

Authors: Christopher Bartee, Justin Riley DeFrancisco, Marcos Feijoo, Siyong Kim, Tianjun Ma

Affiliation: Blue Physics LLC, Virginia Commonwealth University

Abstract Preview: Purpose: Irradiation with FLASH has been shown to decrease normal tissue toxicity while maintaining similar tumor control. To advance FLASH into the clinic, more preclinical investigations are first n...

FMEA for Direct to Unit Adaptive Radiotherapy

Authors: Haleem Azmy, Robbie Beckert, Farnoush Forghani, Dean Hobbis, Dan Hong, Hyun Kim, Eric Laugeman, Silpa Raju-Salicki, Domenic Sievert

Affiliation: Washington University in St. Louis School of Medicine, WashU Medicine, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine in St. Louis, Washington University School of Medicine, Wash U Medicine, Washington University in St. Louis

Abstract Preview: Purpose: A novel radiation therapy (RT) workflow has recently emerged with the advent of online adaptive RT systems, direct-to-unit (DTU). DTU utilizes online adaptive platforms (MR and CT based) to o...

Flash Radiation Spares Reproductive Capability in Adult C. Elegans

Authors: Barry Andricks, Stratton Black, Scott R. Floyd, Ashutosh Kotwal, Eric L. Martin, Stepan Mikhailov, Mark Oldham, Niccolo Terrando, Andrew Thompson, Ying Wu

Affiliation: Department of Physics, Duke University, Medical Physics Graduate Program, Duke University, Duke University, Department of Radiation Oncology, Duke University Medical Center, Triangle Universities Nuclear Laboratory

Abstract Preview: Purpose: To evaluate and quantify the effects of high energy electron radiation delivered at FLASH and conventional dose rates on the reproductive capability of adult C. elegans nematodes.
Methods:...

Impact of Diacetylene Polymer Chemistry on Real-Time Radiochromic Film Dosimetry

Authors: Rohith Kaiyum, Ozzy Mermut, Alexandra Rink

Affiliation: Department of Medical Biophysics, University of Toronto, Department of Physics and Astronomy, York University

Abstract Preview: Purpose: To investigate the relationship between chemical features and real-time response to ionizing radiation dose of radiochromic diacetylene crystals.
Methods: A number of radiochromic diacetyl...

Investigating the Radiation Chemistry of Flash Radiation Therapy through Electron Paramagnetic (EPR) Spectroscopy

Authors: Ramin Abolfath, Alexander Baikalov, Stefan Bartzsch, Nolan M. Esplen, Alan Eduardo Lopez Hernandez, Emil Schueler

Affiliation: MD Anderson Cancer Center, PI Experimental Medical Physics, Institute of Radiation Medicine (IRM), Helmholtz Munich, Germany, Howard University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: FLASH radiation therapy (FLASH-RT) leverages ultra-high dose rates (UHDR) to spare normal tissue as compared to conventional (CONV)-RT while preserving tumor control; this is termed the FLASH...

Investigation on Quantifying Chemical Species Post Electron and Proton Irradiation Using the Geant4-DNA 'UHDR' Example

Authors: Konstantinos Chatzipapas, George C. Kagadis, Panagiotis Konstas, Dimitris N. Mihailidis, Dimitris Visvikis

Affiliation: LaTIM, INSERM UMR1101, University of Pennsylvania, LaTIM, INSERM, University of Brest, University of Patras

Abstract Preview: Purpose: This study investigates the temporal evolution of radiolytic species (H3O+, OH•, OH-) in water under electron and proton irradiation using the mesoscopic chemistry model that allows longer te...

Photon Counting CT Method for Accurate Effective Atomic Number and Electron Density Measurement

Authors: Mohammed Alzaabi, Abderaouf Behouch, Nabil Maalej, Aamir Raja, Briya Tariq

Affiliation: Khalifa University

Abstract Preview: Purpose: Spectral Photon Counting CT (SPCCT) has emerged as a transformative technology in CT imaging capable of producing images from distinct energy windows, allowing improved material characterizat...

Photon-Counting CT for Estimation of Quantitative Information for Radiation Therapy Treatment Planning: Assessment of Scanning Conditions and Phantom Sizes

Authors: Carina Gassner, Guyue Hu, Thomas Kröncke, Christopher Kurz, Guillaume Landry, Katharina Niepel, Katia Parodi, Franka Risch, Florian Schwarz

Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)

Abstract Preview: Purpose: To evaluate the performance of a clinical photon-counting CT (PCCT) scanner in terms of proton relative stopping power (RSP) estimation using PCCT data and to compare the impact of different ...

Reduction of the Charge Build-up Effect on the Beam Current Transformers for Real-Time Monitoring of Ultra-High Dose per-Pulse Electron Beams

Authors: Wesley S. Culberson, Miguel Angel Flores Mancera, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Beam current transformers (BCTs) are a promising alternative to ion chambers for real-time monitoring of ultra-high dose per-pulse (UHDPP) beams. The signal of the BCT is insensitive to ion r...

Secondary Neutron Dosimetry of Cieds Exposed to Neutron-Producing Photon Radiation Therapy

Authors: Angela Gearhardt, Stephen F. Kry, Christopher Ryan Peeler, Julianne M. Pollard-Larkin

Affiliation: The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences; The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: A growing number of radiation therapy (RT) patients have cardiovascular implantable electronic devices (CIEDs). Patients with CIEDs must be carefully managed because the devices are susceptib...

Spectral CT Assessment of 3D Printing Techniques for Improving the Uniformity and Reproducibility of Models Applied in Medical Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: Filament deposition modeling (FDM) 3D printers may utilize proprietary calibration methods inadequate for medical imaging. Proper techniques are necessary to achieve imaging uniformity standa...

Two's Company, Three's a Crowd? a Bayesian Approach to Optimizing the Number of Measurement Readings in Radiation Therapy QA

Authors: Siyong Kim, Ava Paek, Joseph B. Schulz, James J. Sohn, Eric D. Stolen, Ethan D. Stolen

Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Central Florida, Virginia Commonwealth University, Department of Radiation and Cellular Oncology, University of Chicago, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: The American Association of Physicists in Medicine Task Group 142 (AAPM TG-142) guidelines recommend three measurements during monthly quality assurance to keep results within two standard de...

Validation of Updated CT-to-SPR Calibration Method with Icrp-145 Data for Carbon-Ion Radiotherapy

Authors: Min Cheol Han, Soorim Han, Chan Hyeong Kim, Jin Sung Kim, Seok-Ho Lee, Gahee Son, Yongdo Yun

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Hanyang University, Department of Integrative Medicine, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: The stoichiometric calibration method proposed by Kanematsu et al. (2016) has been widely adopted for CT number to stopping-power ratio (SPR) conversion in carbon-ion radiotherapy. With the r...

Virtual Monoenergetic Imaging for Radiotherapy: A Single CT Acquisition for Both Target Delineation and Dose Calculation

Authors: Harold Y Hu, Yanle Hu, Shuai Leng, Maryam Sadeghian, Joe Swicklik

Affiliation: Mayo Clinic Arizona, Basis Scottsdale, Mayo Clinic

Abstract Preview: Purpose: Radiotherapy CT simulation often requires two scans: a non-contrast scan for dose calculation and a contrast-enhanced scan for target delineation. Photon-counting-detector (PCD) CT allows the...