Search Submissions 🔎

Results for "pulsed proton": 14 found

0.23T/1.5T MRI Imaging for Spine with Instrumentations

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
MRI images with minimal artefacts to scan spine with Titanium instrumentation (screws, stabilizing rods, and spacer) are acquired by optimizing scanning parameters of pulse sequences (main...

12 Year Clinical Experience with Low-Tesla MRI for Tumor Progression

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
Low-Tesla MRI (0.23T Panorama MR Scanner, Philips) has been used for tumor progression during proton therapy treatments, and for initial contouring in addition to diagnostic MRI. The pulse...

A Quantitative Analysis of Interplay Effects in IMPT for Lung Cancer SBRT: Comparing Two Machine Delivery Sequence Models

Authors: Xiaoda Cong, Xuanfeng Ding, Gang Liu, Peilin Liu, Lewei Zhao

Affiliation: Department of Radiation Oncology, Stanford University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Corewellhealth William Beaumont University Hospital

Abstract Preview: Purpose: This study quantitatively evaluates the interplay effect in intensity-modulated proton therapy (IMPT) for lung cancer stereotactic body radiotherapy (SBRT) using two different machine deliver...

Accuracy Assessment of Bragg Peak Imaging Using Protoacoustics at a Clinical Dose

Authors: Michael Caulfield, Ye Chen, Yoshihiro Ishi, Yasutoshi Kuriyama, Taeko Matsuura, Naoki Miyamoto, Taichi Murakami, Tomonori Uesugi, Kohei Yokokawa

Affiliation: Hokkaido University, Kyoto University, University of Alberta

Abstract Preview: Purpose: Protoacoustics has the potential for real-time and direct imaging of the Bragg peak. This study investigated the accuracy of the Bragg peak imaging based on the water phantom experiment at a ...

Characterization of Commercially-Available Dosimeters and Prototype Diamond Detectors for Absolute Flash Dosimetry of Small-Field Pulsed Proton Beams

Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang

Affiliation: 4Physikalisch-Technische Werkstätten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...

Establishing a Conventional Linac-Based Electron Flash Beam

Authors: Christopher Bartee, Justin Riley DeFrancisco, Marcos Feijoo, Siyong Kim, Tianjun Ma

Affiliation: Blue Physics LLC, Virginia Commonwealth University

Abstract Preview: Purpose: Irradiation with FLASH has been shown to decrease normal tissue toxicity while maintaining similar tumor control. To advance FLASH into the clinic, more preclinical investigations are first n...

Evaluating Pulse Normalization for Enhanced Ion Chamber Signal Correction in Relative Dosimetry during Beam Scanning

Authors: Alejandro Cuadra, Paulina E. Galavis, Juan Leal, Enrique Lozano, Franklin Reggio, Gabriel Zelada

Affiliation: Clínica Iram, Clinica Alemana, Hospital Clínico de Magallanes, E&G Medical Systems Ltda, NYU Langone Health

Abstract Preview: Purpose: To investigate and compare the new method “Pulse Normalization” proposed by Sun Nuclear to correct ion chamber signal for fluctuations in the accelerator output while performing relative dosi...

Immobilization and Optimization of Pulse Sequences for 0.23T MRI

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
It has been challenging to acquire clinically useful MR images of pediatric cancer patients without anesthesia, and MR contrast agents. Custom-made immobilization devices and optimization ...

Physics-Informed Neural Network for In Vivo Dosimetry during Proton Therapy Using Protoacoustic Tomography

Authors: Kristina Bjegovic, Yong Chen, Gilberto Gonzalez, Yankun Lang, Lei Ren, Leshan Sun, Liangzhong Xiang, Yifei Xu

Affiliation: University of Maryland School of Medicine, University of California, Irvine, University of Oklahoma Health Sciences Center, University of Oklahoma Health Science Center

Abstract Preview: Purpose: Proton therapy is becoming an increasingly popular choice for cancer treatment due to its precision, reduced side effects, and effectiveness. While dosimetry is fundamental to the success of ...

Radial Waveguide Structures for Enhanced Power Transmission Efficiency in Dielectric Wall Accelerators

Authors: Julien Bancheri, Chau Giang Bui, David G Cooke, Christopher M Lund, Morgan J Maher, Jan P. Seuntjens, Jason Z Yuan

Affiliation: Princess Margaret Cancer Centre & University of Toronto, Medical Biophysics, University of Toronto, University of Toronto, Medical Physics Unit, McGill University, Department of Physics, McGill University

Abstract Preview: Purpose: The dielectric wall accelerator (DWA) offers a low-cost solution for proton therapy, using non-resonant waveguides to accelerate particles. Radial waveguides (RWGs), consisting of a dielectri...

Radiochemical Monte Carlo Model to Investigate the Oxygen Impacts on Radical Yields Under Proton Flash Irradiation

Authors: Yao Hao, Yuting Peng, Francisco Javier Reynoso, Tianyu Zhao, Xiandong Zhao

Affiliation: Varian, University of South Florida, Washington University School of Medicine, Washington University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Ultra-high dose-rate (FLASH) dose rate (> 40 Gy/s) may result in a radio-protective effect in healthy tissue compared with conventional dose rate (CDR). This effect has been observed in vivo ...

Remote Evaluation of Flash Beamlines for Electron, Proton, and MV Photons

Authors: Alexander Baikalov, Luke Connell, Nolan M. Esplen, Michele M. Kim, Stephen F. Kry, Emil Schueler, Hayden Scott, Ryan Sun, Paige A. Taylor, Uwe Titt

Affiliation: The University of Texas MD Anderson Cancer Center, University of Pennsylvania, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: to develop an affordable, portable device for accurately measuring FLASH dose rates from protons, electrons, and photons. 4 detectors were utilized to measure the temporal structure of proton...

Slit Scanning Delivery Simulation for Flash Radiotherapy

Authors: Muhammad Ramish Ashraf, Dixin Chen, Aaron Garza, Lloyd Emmanuel Kamole Ghomsi, Edward Elliot Graves, Billy W Loo, Stavros Melemenidis, Joseph B. Schulz, Lawrie Skinner, Murat Surucu

Affiliation: Department of Radiation Oncology, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: FLASH radiotherapy, supported by robust preclinical evidence showing an improved therapeutic index, is advancing toward clinical trials. Clinical FLASH treatments will likely require scanning...

Two Radiochemical Monte Carlo Models to Investigate the Radical Yields Under Proton Flash Irradiations

Authors: Yujie Chi, Yao Hao, Xun Jia, Youfang Lai, Yuting Peng, Francisco Javier Reynoso, Lingshu Yin, Tianyu Zhao, Xiandong Zhao

Affiliation: Johns Hopkins University, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Physics, University of Texas at Arlington, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, University of South Florida

Abstract Preview: Purpose: FLASH radiation therapy has shown remarkable tissue sparing effects compared to radiation therapy at conventional dose rates (CDR). Yet, its mechanism remains unclear. Radical production modu...